The ILMI protocol is also used for ATM address registration across an ATM UNI, and for the following:
ILMI reduces the need for manual configuration of attached end-systems, and is important in the plug-and-play operation of Lightstream 1010 based networks. ILMI is also used to inform LANE clients of the location of the LANE Configuration Server (LECS). ILMI on the LightStream 1010 also allows the switch to provide Cisco ATM adapters with the address of an Internet protocol (IP) over ATM (RFC 1577) Address Resolution Protocol (ARP) server. This allows plug-and-play operation of ATM desktops.
Two tasks will be described in the following sections:
This section describes configuring the ATM address and the LAN emulation configuration server (LECS) address, and displaying the ILMI configuration for the entire switch.
The LightStream 1010 ATM Switch is autoconfigured with an ATM address using a hierarchical addressing model similar to the Open System Interconnect (OSI) network service access point (NSAP) addresses. PNNI uses this hierarchy to construct ATM peer groups. ILMI uses the first 13 bytes of this address as the switch prefix that it registers with end systems.
During the initial startup, the LightStream 1010 generates an ATM address using the defaults described in the section "ATM Address Configuration" in the chapter "Initially Configuring the LightStream 1010 ATM Switch."
For configuration of a new ATM address that replaces the previous ATM address and is used to generate a new PNNI node ID and peer group ID, see the section "Configure PNNI Node" in the chapter "Configuring ATM Routing and PNNI."
Multiple addresses can be configured for a single switch and this configuration can be used during ATM address migration. ILMI registers end systems with multiple prefixes during this period until an old address is removed. PNNI automatically summarizes all of the switch's prefixes in its reachable address advertisement.
To configure a new ATM address that replaces the previous ATM address when running IISP only, perform the following task in global configuration mode:
| Task | Command |
|---|---|
At the privileged EXEC prompt, enter configuration mode from the terminal. | |
At the configuration mode prompt, configure the new ATM address for the switch. | |
At the configuration mode prompt, remove the old ATM address from the switch. |
| 1This command is documented in the LightStream 1010 ATM Switch Command Reference publication. |
The following example adds the ATM address prefix 47.0091.8100.5670.000.0ca7.ce01 and the ellipses (...) add the default MAC address as the last six bytes.
Switch(config)#atm address 47.0091.8100.5670.0000.0ca7.ce01...
Switch(config)#
The Lightstream 1010 ATM switch allows configuration of per interface ILMI address prefixes. This allows for different address prefixes to be registered with end systems attached to different interfaces. When any per interface ILMI address prefixes are configured, they override the prefix(es) derived from the first 13-bytes of the switch ATM address(es), for that specific interface.
Multiple ILMI address prefixes can be configured on each interface, for example, during ATM address migration.
To configure a per interface ILMI address prefix, use the following command using the no form of this command to remove the prefix:
| Task | Command |
|---|---|
At the privileged EXEC prompt, enter configuration mode from the terminal. | configure1 |
Specify an ATM interface and enter interface configuration mode. | interface atm card/sub_card/port |
Configure the ILMI address prefix. | atm prefix 13-byte prefix |
| 1These commands are documented in the LightStream 1010 ATM Switch Command Reference publication. |
The following example changes the ATM address of the switch from the auto-configured address 47.0091.8100.0000.0041.0b0a.1081.0041.0b0a.1081.00 to the new address prefix 47.0091.8100.5670.0000.0000.1122.0041.0b0a.1081.00:
Switch(config)#atm address 47.0091.8100.5670.0000.0000.1122...
Switch(config)#no atm address 47.0091.8100.0000.0041.0b0a.1081...
The following example configure an additional ATM address manually, address prefix 47.0091.8100.0000.0003.c386.b301 on ATM interface 0/0/1:
Switch(config)#interface atm 0/0/1
Switch(config-if)#atm prefix 47.0091.8100.0000.0003.c386.b301
Switch(config-if)#
Use the show atm address command to display the ILMI address prefix configuration for all interfaces or a specific interface.
To display the ILMI address prefix configuration, perform the following task in user EXEC mode:
| Task | Command |
|---|---|
Display the interface ILMI address prefix configuration. | show atm address |
The following example displays the ILMI address prefix configuration for all ATM interfaces:
Switch#show atm address
Switch Address(es): 47.00918100000000410B0A1081.00410B0A1081.00 active 47.00918100000000603E5ADB01.00603E5ADB01.00 47.009181005670000000001122.00400B0A1081.00 Soft VC Address(es): 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.0000.00 ATM0/0/0 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.0000.63 ATM0/0/0.99 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.0010.00 ATM0/0/1 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.0020.00 ATM0/0/2 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.0030.00 ATM0/0/3 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.1000.00 ATM0/1/0 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.1010.00 ATM0/1/1 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.1020.00 ATM0/1/2 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.1030.00 ATM0/1/3 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.8000.00 ATM1/0/0 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.8010.00 ATM1/0/1 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.8020.00 ATM1/0/2 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.8030.00 ATM1/0/3 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.9000.00 ATM1/1/0 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.9010.00 ATM1/1/1 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.9020.00 ATM1/1/2 47.0091.8100.0000.0041.0b0a.1081.4000.0c80.9030.00 ATM1/1/3 ILMI Switch Prefix(es): 47.0091.8100.0000.0041.0b0a.1081 47.0091.8100.0000.0060.3e5a.db01 47.0091.8100.5670.0000.0000.1122 ILMI Configured Interface Prefix(es): LECS Address(es): Switch#
Use the following command to configure the LAN Emulation Configuration Server (LECS) address advertised to the directly connected end nodes. Use the no form of this command to return to the default configuration.
| Task | Command |
|---|---|
At the privileged EXEC prompt, enter configuration mode from the terminal. | |
Configure the switch LECS address. | atm lecs-address lecs-address [sequence_number] |
| 1This command is documented in the LightStream 1010 ATM Switch Command Reference publication. |
The sequence_number provides the position of this address in the ordered LECS address table.
The following example configures the LECS ATM address:
Switch(config)#atm lecs-address 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9030.01
Switch(config)#
Proceed to the following section to confirm the switch ILMI configuration.
To display the switch ILMI configuration, use the following EXEC mode commands:
| Task | Command |
|---|---|
Display the ATM addresses. | |
Display the ILMI configuration. | |
Display the ILMI status. |
The following example displays the LightStream 1010 ATM address and the LECS address:
Switch#show atm address
Switch Address(es): 47.00918100000000000CA79E01.00000CA79E01.00 active 88.888888880000000000000000.000000005151.00 Soft VC Address(es): 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.0000.00 ATM2/0/0 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.8000.00 ATM3/0/0 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.8010.00 ATM3/0/1 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.8020.00 ATM3/0/2 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.8030.00 ATM3/0/3 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9000.00 ATM3/1/0 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9010.00 ATM3/1/1 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9020.00 ATM3/1/2 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9030.00 ATM3/1/3 ILMI Switch Prefix(es): 47.0091.8100.0000.0000.0ca7.9e01 88.8888.8888.0000.0000.0000.0000 ILMI Configured Interface Prefix(es): LECS Address(es): 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9030.01 47.0091.8100.0000.0000.0ca7.9e01.4000.0c81.9030.02 Switch#
The following example displays the ILMI configuration:
Switch#show atm ilmi-configuration
Switch ATM Address (s) :
1122334455667788990112233445566778899000
LECS Address (s):
1122334455667788990011223344556677889900
ARP Server Address (s):
1122334455667788990011223344556677889900
Switch#
The following example displays the ILMI status:
Switch#show atm ilmi-status
Interface : ATM2/0/0 Interface Type : Local Configured Prefix(s) : 47.0091.8100.0000.0003.c386.b301 Interface : ATM3/0/0 Interface Type : Private NNI ILMI VCC : (0, 16) ILMI Keepalive : Disabled Configured Prefix(s) : 47.0091.8100.0000.0003.c386.b301 Interface : ATM3/0/3 Interface Type : Private NNI ILMI VCC : (0, 16) ILMI Keepalive : Disabled Configured Prefix(s) : 47.0091.8100.0000.0003.c386.b301 Switch#
This section describes configuration of an ILMI interface on a per interface basis. Use the no form of the following commands to disable ILMI parameters:
| Task | Command |
|---|---|
At the privileged EXEC prompt, enter configuration mode from the terminal. | |
Select interface port. | interface atm card/subcard/port [.vpt#] |
Configure the well-known ILMI VPI = 0, VCI = 16. | atm pvc vpi vci |
Enable ILMI for a specific interface. | |
Configure ILMI address registration for a specified interface. | |
Enable ILMI link determination feature. | |
Configure ILMI keepalive. | atm ilmi-keepalive [seconds] |
| 1This command is documented in the LightStream 1010 ATM Switch Command Reference publication. |
The following example enables ILMI on ATM interface 3/0/3:
Switch(config)#interface atm 3/0/3
Switch(config-if)#atm ilmi-enable
Switch(config-if)#
The following example enables ATM address registration on ATM interface 3/0/3:
Switch(config)#interface atm 3/0/3
Switch(config-if)#atm address-registration
Switch(config-if)#
The following example configures the ILMI ATM interface 3/0/3 with a keepalive time of 20 seconds:
Switch(config)#interface atm 3/0/3
Switch(config-if)#atm ilmi-keepalive 20
Switch(config-if)#
In this example, the peer network element is polled every 20 seconds.
Proceed to the following section to confirm the ILMI interface configuration.
To show the ILMI configuration use the following EXEC mode command:
| Task | Command |
|---|---|
Show the ILMI configuration on a per port basis. | show atm ilmi-status atm card/sub_card/port |
The following example displays the ILMI status for ATM interface 3/0/0:
Switch#show atm ilmi-status atm 3/0/0
Interface : ATM3/0/0 Interface Type : Private NNI ILMI VCC : (0, 16) ILMI Keepalive : Disabled Configured Prefix(s) : 47.0091.8100.0000.0003.c386.b301 Switch# Switch#
|
|