cc/td/doc/product/atm/c8540/wa5/12_0/3a_11
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Y Commands

Y Commands

The commands shown in this chapter apply to the Catalyst 8540 MSR, Catalyst 8510 MSR, and LightStream 1010. Where an entire command or certain attributes of a command have values specific to a particular switch, an exception is indicated by the following callouts:


Note Commands that are identical to those documented in the Cisco IOS software documentation have been removed from this chapter. Refer to Appendix D, "Removed and Changed Commands," of this command reference for a list of removed commands.

yellow (Catalyst 8510 MSR and LightStream 1010)

To enable the functionality of generation and detection of the yellow alarm in the system, use the yellow interface configuration command. To disable the functionality, use the no form of this command.

yellow {generation | detection}
no yellow {generation | detection}

Syntax Description

generation

If set, yellow alarm is generated in the event of frame loss.

detection

If set, yellow alarm is detected in the event of the remote end experiencing frame loss and transmitting yellow.

Default

Both generation and detection are enabled.

Command Mode

Interface configuration

Usage Guidelines

If the received signal has been lost the yellow alarm should be generated to indicate a frame loss event, thus ensuring that the alarm is sent to the remote end.

When the remote end is transmitting a yellow alarm indicating a frame loss event, the yellow alarm detection must be enabled to detect the alarm condition.

Disable the yellow alarm gereration and detection depending upon the circumstances. Enabling yellow detection would be useless if the remote end has yellow genration disabled.

Examples

The following example shows how to enable the generation and detection of yellow alarm.

Switch(config)# interface atm 0/1/0
Switch(config-if)# yellow generation
Switch(config)# interface atm 0/1/0
Switch(config-if)# yellow detection
 

The following examples shows how to disable the generation and detection of yellow alarm

Switch(config)# interface atm 0/1/0
Switch(config-if)# no yellow generation
Switch(config)# interface atm 0/1/0
Switch(config-if)# no yellow detection


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Oct 25 12:54:56 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.