cc/td/doc/product/atm/c8540/wa5/12_0/12_3
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

 INDEX

 INDEX

Symbols


# (pound sign)
in a prompt     2-5

* (asterisk)
as wildcard     13-4

> (angle bracket)
in a prompt     2-4

(ellipsis)
as wildcard     13-4

Numerics


155 Mbps
default configuration     17-3
interface configuration     17-4
SM, MM, UTP interface configuration     17-3

25 Mbps
default configuration     17-2
interface configuration     17-2

622 Mbps
default configuration     17-7
interface configuration     17-6

A


aaa accounting command     4-13

aaa new-model command     4-13

AAA/TACACS+
description     4-11

abbreviations
of commands     2-2

ABR
configuring limits of best-effort connections     8-30

access control
inbound     11-10
IP     11-10
list     11-1
outbound     11-10
using     11-1

access filter     9-3

access lists
See IP access lists

access-class command     11-10

access-list command     11-9

accounting file configuration mode
See ATM accounting file configuration mode

accounting selection configuration mode
See ATM accounting selection configuration mode

addressing schemes
ATM     3-5, 9-2
ATM switch router chassis, table (Catalyst 8540 MSR)     2-6
autoconfigured ATM     3-5
hierarchical model of     3-5
See also ATM address

administrative interface
configuring     3-31

administrative-weight command     10-40

AESA     9-3

age-timer command     16-15

aggregation-mode command     10-46

AIS
DS3 and E3     17-9
enabling on interface, example     6-4
enabling, example (Catalyst 8510 MSR and LightStream 1010)     6-3
enabling, example (Catalyst 8540 MSR)     6-3
T1 and E1     17-11, 17-12

alarm indication signals
See AIS

ARP     9-1

ASP
ATM switch processor     1-2

ATM
configuring inverse ARP in PVC environment     12-5

atm abr-mode command (Catalyst 8510 MSR and LightStream 1010)     8-9

atm access-group command     11-6

ATM accounting
configuring     14-1
file configuration mode     14-7
selection configuration mode     14-5
SNMP traps     14-9

atm accounting collection command     14-8

atm accounting command     14-4

atm accounting enable command     14-3

atm accounting file command     14-7, 14-12
entering command mode with     2-11

ATM accounting file configuration mode
description     2-11
table     2-3

atm accounting selection command     14-5
entering command mode with     2-11

ATM accounting selection configuration mode
description     2-11
table     2-3

atm accounting trap threshold command     14-10

ATM address
autoconfigured     3-5
changing active     10-6
configuration prerequisites     3-2
configuring     3-5, 9-2
LANE, MAC address and ESI field     13-3
manual configuration     3-5
testing correct configuration     3-36
uniqueness rule, note     3-5
wildcards in LANE templates     13-4

atm address command     9-2, 10-6, 10-10

ATM address prefix
as ping destination (Catalyst 8510 MSR and LightStream 1010)     6-5

atm address-registration command     9-6

atm address-registration permit command     11-12

atm arp-server nsap command     12-3

atm arp-server time-out command     12-4

atm auto-configuration command     9-6

atm cac best-effort configuration     8-30

atm cac best-effort-limit command     8-30

atm cac link-sharing command     8-25

atm cac max-peak-cell-rate command     8-32

atm cac service-category command     8-37

ATM connection
checking reachability (Catalyst 8510 MSR and LightStream 1010)     6-5
checking reachability (Catalyst 8540 MSR)     6-4
testing configuration     3-37

atm connection-traffic-table-row command     7-11, 7-13, 7-16, 8-12

ATM E.164 translation table configuration mode
description     2-12
table     2-4

atm e164 address command     16-7

atm e164 auto-conversion command     16-11

atm e164 translation command     16-13

atm e164 translation-table command     16-13
entering command mode with     2-12

ATM end system address
See AESA

atm esi-address command     12-3, 12-4

atm filter-expr command     11-5

atm filter-set command     11-3

atm hierarchical-tunnel command     7-16

atm iisp command     7-9

atm ilmi default-access permit command     9-3

atm ilmi-keepalive command     9-6

ATM interface
configuring, examples     15-5
displaying configuration     15-5
displaying tag switching configuration, example     15-5
enabling tag switching on     15-4
testing configuration     3-37
testing status of     3-38

atm lecs-address command     9-4, 13-15

atm lecs-address-default command     13-9

atm link-distance command     8-29

atm manual-well-known-vc command     5-26

atm maxvci-bits command     17-4, 17-7, 17-10, 17-12

atm maxvpi-bits command     17-3, 17-4, 17-6, 17-7, 17-10, 17-12

atm nni command     7-6, 7-7

atm nsap-address command     12-3, 12-4, 12-9

atm oam command     6-4

atm oam command (Catalyst 8510 MSR and LightStream 1010)     6-3

atm oam command (Catalyst 8540 MSR)     6-3

atm output-queue command (Catalyst 8510 MSR and LightStream 1010)     8-19

atm output-threshold command (Catalyst 8510 MSR and LightStream 1010)     8-21

atm over-subscription-factor command (Catalyst 8510 MSR and LightStream 1010)     8-7

atm pacing command     8-23

atm pnni admin-weight command     10-41

atm pnni aggregation-token command     10-44

atm pnni explicit-path command     10-36

atm pnni link-selection command     10-32

atm prefix command     9-7

atm pvc command     5-3, 5-6, 5-10, 5-26, 7-19, 12-7

atm pvc encap aal5snap command     12-6

atm pvp command     5-8, 7-11, 7-14, 7-16, 15-9, 15-11

atm qos command     8-6

atm rmon collect command     14-15

atm rmon enable command     14-16

atm rmon portselgrp command     14-14

atm route command     3-23, 10-7, 10-11, 12-3, 12-4, 16-6, 16-11

atm route prefix command     7-9

atm route-optimization command     5-23

ATM router configuration mode
description     2-10
table     2-3

atm router pnni command
aggregation mode     10-46
background route computation     10-29
complex node representation     10-49
configure ATM Address and PNNI node level     10-10
entering command mode with     2-10
global administrative weight     10-39
hello, database sync, and flooding     10-50
logical group node and peer group ID     10-16
maximum administrative weight percentage     10-33
node election leadership priority     10-20
node name     10-18
parent node     10-19
precedence     10-34
redistribution     10-43
scope mapping     10-15
significant change threshold     10-47
statistics collection     10-53
summary address     10-13, 10-22
transmit restriction     10-42

atm routing-mode static command     10-4

atm service-category-limit command (Catalyst 8510 MSR and LightStream 1010)     8-8

atm service-class command     15-15

atm signalling cug access command     16-23

atm signalling cug alias command     16-22

atm signalling cug assign command     16-23

atm signalling diagnostics command     16-15
entering command mode with     2-13

ATM signalling diagnostics configuration mode
description     2-13
table     2-4

atm signalling diagnostics enable command     16-15

atm signalling ie forward command     16-1

atm signalling vpci command     7-18

atm snoop interface atm command     5-30

atm snoop-vc command     5-31

atm snoop-vp command     5-31

atm soft-vc command     5-16

atm soft-vp command     5-20

atm sustained-cell-rate-margin-factor command     8-13

atm svcc vci min command     7-21

atm svcc vpi max command     7-21

atm svc-frame-discard-on-aal5ie command     16-3

atm svpc vpi max command     7-21

ATM switch
configuration methods     3-1
connection characteristics (Catalyst 8540 MSR)     1-4
overview (Catalyst 8540 MSR)     1-1
overview (LightStream 1010 and Catalyst 8510 MSR)     1-2
self-configuring features     1-4
support for port adapters     1-3

ATM switch hardware
functions performed on OAM cells     6-2

ATM switch processor
See ASP

ATM switch router (Catalyst 8540 MSR
system availability)     1-4

ATM switch router (Catalyst 8540 MSR)
hardware components on     1-2
modular chassis for     1-2

ATM switch router (Catalyst 8540)
modular chassis for     1-1

atm template-alias command     11-2

atm threshold-group command     8-16, 8-17

atm uni command     7-4, 17-3, 17-4, 17-6, 17-7, 17-9, 17-12

atm uni type command     17-3

ATM VP tunnels
configuring     7-12

atm0 interface
note     3-8

authentication
dynamic     11-9

autoconfiguration     7-2

auto-ferf command     17-10, 17-12

auto-summary command     10-13, 10-22

B


background-routes-enable command     10-29

best-effort connections
configuring limits     8-30
displaying configuration     8-31

BOOTP server
configuration prerequisites     3-2
configuring     3-3

buffers command     4-2

C


cablelength command     19-4

calendar set command     4-11

called-address-mask command     16-16

called-nsap-address command     16-15

calling-nsap-address command     16-16

carrier modules
documentation     xxiii

CAS
CES framing formats
not used with CES     18-18
not used with soft PVC     18-20
used with CES and on-hook detection     18-33
used with soft PVC     18-25

cast-type command     16-16

CBR
atm connection-traffic-table-row command     8-12
atm output-queue command     8-19
CAC parameter to bandwidth relationship     8-25
CTT row default     8-12
equation     8-7
FC-PCQ and FC-PFQ feature comparison (Catalyst 8510 MSR and LightStream 1010)     8-4
interface output discard threshold     8-21
interface output pacing     8-23
interface queue thresholds per service category (Catalyst 8510 MSR and LightStream 1010)     8-21
interface type default     8-7
output queue maximum     8-19
service category limit (Catalyst 8510 MSR and LightStream 1010)     8-8
switch processor features (Catalyst 8540 MSR)     8-3

CBR traffic
network clock services for     3-23

CCO
information and services availability     xxiii

cdp command     4-2

CDS3 FR controllers
changing default cable lengths, example     19-4
displaying configuration     19-5
displaying serial information, example     19-6

CDS3 FR port adapters
configuring     19-3
default configuration     19-3

CDVT
configuring ATM default     8-33
displaying configuration     8-34

CE1 FR controllers
changing default yellow alarms, example     19-9
displaying configuration, example     19-9

CE1 FR port adapters
defaults     19-8

cell delay variation tolerance
See CDVT

cell flows
on demand or periodic, note     6-2
support for     6-1

cell-payload scrambling
disabling     3-6

ces aal1 clock command     18-4, 18-9, 18-10, 18-13, 18-18, 18-21, 18-30

ces aal1 service command     18-4

ces aal1 service structured command     18-18, 18-21, 18-29, 18-36

ces aal1 service unstructured command     18-8, 18-13

ces circuit 0 cdv command     18-4

ces circuit 0 circuit-name command     18-9, 18-13

ces circuit 0 shutdown command     18-10

ces circuit command     18-14, 18-19, 18-22, 18-23, 18-26, 18-29, 18-30, 18-31, 18-33, 18-36

ces circuit shutdown command     18-22

CES circuits
configuring SGCP     18-35

ces dsx1 clock source command     18-4, 18-10, 18-13, 18-18, 18-29

ces dsx1 framing command     18-4, 18-18, 18-21, 18-29

ces dsx1 lbo command     18-4, 18-5

ces dsx1 linecode command     18-4, 18-5, 18-18, 18-21, 18-29

ces dsx1 loopback command     18-4

ces dsx1 signalmode robbedbit command     18-26

CES E1
default     18-3
interface configuration     18-1, 18-3

CES operations
network clock services for     3-23

ces pvc 0 dest-address command     18-4, 18-14, 18-31

ces pvc 0 interface ATM command     18-9, 18-19, 18-23

CES T1
default     18-3
interface configuration     18-1, 18-3

CES/T1 and CES/E1 (Catalyst 8510 MSR and LightStream 1010)     18-2

CES/T1 and CES/E1 (Catalyst 8540 MSR)     18-2

CES-IWF     18-2

channel associated signalling
See CAS

channel-group command     19-5, 19-9

channelized DS3 Frame Relay port adapters
See CDS3 FR port adapters

circuit emulation services interworking function
See CES-IWF

circuit emulation services operation
See CES operations

Cisco Connection Online
See CCO

class mappings into service classes, table     15-14

clear cdp command     4-3

clear-cause command     16-16

client-atm-address command     13-12

clock command     4-11

clock module
on the route processor     1-1

clock set command     3-23

clock source command     3-10, 17-4, 17-6, 17-7, 17-10, 17-12, 19-4, 19-9

closed user group
See CUG

collection-modes command     14-7

command modes
ATM accounting file configuration     2-11
ATM accounting selection configuration     2-11
ATM E.164 translation table configuration     2-12
ATM router configuration     2-10
ATM signalling diagnostics configuration     2-13
controller configuration     2-13
interface configuration     2-6
LANE configuration server database configuration     2-12
line configuration (Catalyst 8510 MSR and LightStream 1010)     2-8
line configuration (Catalyst 8540 MSR)     2-8
map-class configuration     2-9
map-list configuration     2-9
PNNI node configuration     2-10
privileged EXEC     2-5
redundancy configuration     2-14
subinterface configuration     2-7
summary, table     2-2, 2-4
user EXEC     2-4

commands
abbreviating     2-2
atm pnni explicit-path     10-36
exclude-node     10-36
ncdp     3-16
ncdp max-diameter     3-16
ncdp revertive     3-16
ncdp source priority     3-16
next-node     10-36
show atm pnni topology node     10-37
show atm vc interface     5-18
show ncdp path root     3-17
show ncdp sources     3-17
show ncdp status     3-17
show ncdp timers     3-17
syntax in documentation     xxii
using no to disable features or functions     2-2

configuration
CES E1 interface     18-3

configuration register
testing installation     3-34

configurations
storing     3-31
testing     3-40
testing NVRAM     3-41

configure command
entering command mode with     2-5

configuring
155 Mbps ATM default interface     17-4
155 Mbps ATM interface     17-4
622 Mbps ATM interface     17-6, 17-7
622 Mbps default configuration     17-7
CES E1 default interface     18-3
CES E1 interface     18-1
CES T1 default interface     18-3
CES T1 interface     18-1, 18-3
DS3 and E3 interface     17-8
DS3/E3 ATM interface     17-9
DS3/E3 default interface     17-9
E1 ATM default interface     17-11
E1 ATM interface     17-11
E1 Frame Relay interface     19-7
E1 trunk interface     17-10
IISP interfaces     7-9
interface snooping     5-30
methods of     3-1
OC-3c default interface     17-5
OC-3c interface     17-5
prerequisites for     3-2
T1 ATM default interface     17-11
T1 ATM interface     17-11
T1 trunk interface     17-10
terminal lines and modem support (Catalyst 8510 MSR and LightStream 1010)     4-2
terminal lines and modem support (Catalyst 8540 MSR)     4-1
troubleshooting interface     17-13

configuring CDS3 Frame Relay interface     19-3

connecting point
in ATM switches     6-2

connection traffic table
See CTT

connection-category command     16-16

connection-traffic-table-rows
See CTTRs

connection-types command     14-5

connectivity
checking (Catalyst 8510 MSR and LightStream 1010)     4-15
checking (Catalyst 8540 MSR)     4-15

constant bit rate
See CBR

constant bit rate traffic
See CBR traffic

controlled link sharing
configuring     8-24
displaying configuration     8-25
minimum and maximum parameter relationships, table     8-25

controller command
entering command mode with     2-13

controller configuration mode
description     2-13

controller configuration mode (Catalyst 8510 MSR and LightStream 1010)
table     2-4

controller e1 command
CE1 interface (Catalyst 8510 MSR and LightStream 1010)     19-9
channel group     19-9

controller T3 command     19-4

CTT
configuring (Catalyst 8510 MSR and LightStream 1010)     8-10
configuring (Catalyst 8540 MSR)     8-10
configuring for Frame Relay/ATM Interworking     19-17
displaying configuration     8-13
Frame Relay/ATM Interworking, table     19-17
management     8-1, 8-2
row allocations and defaults     8-11

CTTRs
restrictions     7-19

CUG     16-19
IC IE     16-19
signalling overview     16-19

D


DACS     18-17

default command     14-5, 14-7

default connections
number in OAM configured connections (Catalyst 8510 MSR and LightStream 1010)     6-3
number in OAM configured connections (Catalyst 8540 MSR)     6-3

default name command     13-12

default QoS objective tables
configuring     8-5
description (Catalyst 8510 MSR and LightStream 1010)     8-2
description (Catalyst 8540 MSR)     8-1
displaying     8-6

default-name command     13-10, 13-11

description command     14-7

digital access and crossconnect system
See DACS

disabling     7-2
autoconfiguration     7-2
signalling     16-25

discard functions
of ATM switch hardware     6-2

documentation
conventions used in     xxi
for carrier modules     xxiii
meaning of cautions used in     xxii
meaning of notes in     xxii
of command syntax     xxii
on CD-ROM     xix

DS3 and E3
configuration     17-9
interface configuration     17-8

E


E.164
addresses     16-4
autoconversion feature     16-5
gateway feature     16-5
one-to-one translation table     16-5, 16-12

E1 ATM default interface
configuring     17-11

E1 channels
configuring, example     19-9

E1 Frame Relay interface
configuring     19-7

e164 address command     16-13

edge switches
description     14-2

EHSA
configuring switch processor     3-30
description     3-24
displaying configuration of switch processors     3-30
establishing spare switch processor     3-30
switching configurations     3-29

election leadership-priority command     10-20

emulated LANs
adding restricted membership
database entries for clients     13-12
configuring restricted membership database entries for all clients     13-11
database for unrestricted membership     13-10
restricted membership     13-11
restricted membership database     13-11

enable command
atm accounting     14-7
entering privileged EXEC mode with     2-5

encapsulation
of Frame Relay on interface     19-10

encapsulation frame-relay command     19-10

end-to-end loopback
enabling on interface, example     6-4

erase startup-config command
configuration files cleared with     3-3

ESI field     13-3

Ethernet
testing connectivity     3-37

Ethernet interface
configuring IP     12-1
configuring LAN emulation     13-1
testing configuration     3-36

Ethernet ports
configuring IP address     3-7

ethernet0 interface
configuring     3-8
note     3-8

exclude-node command     10-36

EXEC command mode
note     2-1
user level description     2-4

EXEC commands
privileged level     2-5

Extended High System Availability
See EHSA

extended system availability     3-24

F


F4 flows
reporting unavailable or not guaranteed paths     6-1

F5 flows
reporting degraded VC performance     6-1

failed-attempts command     14-7

fault management functions
in OAM, note     6-1

fault resistance
of ATM switch router (Catalyst 8540 MSR)     1-4

fault tolerance
simple server redundancy     13-3

FC-PCQ (Catalyst 8510 MSR and LightStream 1010)     8-3
ASP-B with     1-3
ASP-C with     1-3
features     8-2

FC-PFQ (Catalyst 8510 MSR and LightStream 1010)     8-3
features     8-2

feature card per-class queuing
See FC-PCQ

feature card per-flow queuing
See FC-PFQ

feature card types (Catalyst 8510 MSR and LightStream 1010)
FC-PCQ     8-3
FC-PFQ     8-3

features
ATM addressing and plug-and-play operation     1-4

frame discard     16-2

Frame Relay commands
frame-relay intf-type command     19-11
frame-relay lmi-n391dte command     19-14
frame-relay lmi-n392dce command     19-14
frame-relay lmi-n393dce command     19-14
frame-relay lmi-n393dte command     19-14
frame-relay lmi-type command     19-12
frame-relay pvc command     19-21
frame-relay pvc dlci command     19-23, 19-25
frame-relay soft-vc dlci command     19-28

Frame Relay encapsulation
displaying on serial interface, example     19-11
enabling on interface     19-10

Frame Relay serial interface
configuring     19-11
configuring type NNI, example     19-11
displaying configuration     19-12
displaying configuration for interface with Cisco LMI enabled, example     19-15
displaying resource information, example     19-19

Frame Relay soft PVC
route optimization     19-34

Frame Relay/ ATM interworking
configuring service internetworking PVCs     19-24

Frame Relay/ATM Interworking
configuring CTT row, example     19-17
configuring interface tasks     19-18
configuring resource management     19-18
configuring soft PVC connections     19-26
configuring the CTT     19-17
default CTT rows, table     19-17
guidelines for soft PVC connections     19-26
Network IWF, figure     19-2
overview     19-1
Service IWF, figure     19-2

frame-relay accept-overflow command     19-18

frame-relay bc-default command     19-18

frame-relay input-queue command     19-18

frame-relay output-queue command     19-18

frame-relay overbooking command     19-18

frame-relay pvc command     19-21

frame-relay pvc dlci command     19-23, 19-25, 19-26

frame-relay soft-vc dlci command     19-28, 19-30, 19-32

framing command     17-10, 17-12, 19-4

functional image
loading (Catalyst 8540 MSR)     20-5
loading (LightStream 1010 and Catalyst 8510 MSR)     20-8
maintenance (Catalyst 8540 MSR)     20-5
maintenance (LightStream 1010 and Catalyst 8510 MSR)     20-7
understanding (Catalyst 8540 MSR)     20-5
understanding (LightStream 1010 and Catalyst 8510 MSR)     20-7

funneling     16-26

G


global configuration mode
accessing     2-1
configuring interface-level OAM in     6-4
table     2-2

H


hardware
testing installation and configuration (Catalyst 8540 MSR)     3-33
verifying     3-3

hardware RM
description (Catalyst 8510 MSR and LightStream 1010)     8-2

hierarchical VP tunnel
service categories, table     15-14

hostname command     3-24
using     2-4

I


ICMP
host unreachable message     11-10

IISP     9-1
configuring     7-8, 7-9
configuring static routes for     3-23
displaying configurations     7-9

ILMI     9-1
construction of switch prefixes by     3-5
interface configuration     9-6

incoming-port atm command     16-16

initial IP configuration
testing     3-37

interception functions
of ATM switch hardware     6-2

interface
modifying default configuration     3-5
new address formats     3-8

interface address formats
table (Catalyst 8540 MSR)     2-6

interface atm command
enabling the configuration server     13-12
setting up LANE clients and servers     13-13
setting up LANE clients only     13-14

interface command
entering command mode with     2-6, 2-7

interface configuration     18-2
155 Mbps (Catalyst 8510 MSR and LightStream 1010)     17-4
622 Mbps (Catalyst 8510 MSR and LightStream 1010)     17-7
622 Mbps (Catalyst 8540 MSR)     17-6
DS3 and E3 (Catalyst 8540 MSR)     17-8
OC-3c (Catalyst 8540 MSR)     17-5
T1/E1 trunk (Catalyst 8510 MSR and LightStream 1010)     17-11
T1/E1 trunk (Catalyst 8540 MSR)     17-10

interface configuration mode
description     2-6
disabling OAM AIS flow, example     6-4
OAM operations on     6-4
table     2-2

interface level OAM
configuring     6-4

interface serial command     19-28

interface snooping
configuring     5-30

interface-level OAM
enabling AIS and end-to-end loopback, example     6-4

Interim-Interswitch Signalling Protocol
See IISP

interlock code information element
See CUG IC IE

interval command     14-7

IP access lists
applying on inbound or outbound interfaces     11-10
applying to an interface     11-10
configuration, examples     11-11, 11-12
creating extended     11-9
creating standard     11-9
description     11-9
dynamic     11-9
extended     11-9
implicit masks     11-9
implicit masks, example     11-11
logging violations     11-9
standard     11-9
styles     11-9
undefined     11-10
virtual terminal lines     11-10

ip access-group command     11-10

ip address command
ATM ARP client     12-3, 12-4
classical IP over ATM     12-6
IP address and subnet mask     3-7
LANE client     13-14
LANE server, BUS, and client     13-13
loopback interface     15-3
tag switching on the ATM interface     15-4
tag switching on VP tunnels     15-10
TDP control channels     15-8

IP addresses
as configuration prerequisite     3-2
as ping destination (Catalyst 8510 MSR and LightStream 1010)     6-5
assigned by BOOTP protocol     3-3
configuring     3-7
configuring parallel interfaces for, note     15-4
displaying configuration     3-8
of loopback interfaces     15-3
set to default     3-3

ip command     12-7, 12-8, 12-9

ip host-routing command     12-3, 12-4, 12-6, 12-7, 12-9

ip route command     12-8, 20-2

ip unnumbered command     15-4, 15-10

K


keepalive command     19-13

keepalive interval
configuring     19-13

L


LAN emulation
example     13-15

LANE
ATM address of configuration server     13-8
ATM address syntax     13-3
ATM address templates     13-4
configuration plan and worksheet     13-6
configuration server on interface     13-5
configuration task list     13-5
configuring ATM address prefix     13-3
constructing ATM addresses     13-3
database task list     13-9
default database name     13-9
emulated LANs and subnetworks     13-14
enabling the configuration server     13-12
ESI field in ATM address     13-3
ESI template     13-4
ESI values derived from MAC address     13-4
MAC addresses     13-3
membership     13-6
prefix template     13-4
restricted membership database     13-11
routing between emulated LANs     13-13, 13-14
rules for assigning components to subinterfaces     13-5
setting up client and server     13-13  to 13-14
setting up database     13-9
setting up database for unrestricted membership     13-10
setting up server and clients     13-13  to 13-14
unique ATM address for     13-3
values of wildcard characters, table     13-4
wildcards in ATM address templates     13-4

LANE client
assigning protocol address     13-14
changing to different emulated LAN     13-13
MAC address for     13-3

lane client ethernet command     13-13, 13-14, 13-15, 13-16

lane client-atm-address command     13-15

lane config auto-config-atm-address command     13-12

lane config database command     13-12

LANE configuration server
See LECS

LANE configuration server database configuration mode
description     2-12
table     2-4

lane database command     13-9, 13-10, 13-11, 13-16
entering command mode with     2-12

lane server-bus ethernet command     13-13

lbo command     17-10, 17-12

LECS     9-1

line command
entering command mode with (Catalyst 8510 MSR and LightStream 1010)     2-8
entering command mode with (Catalyst 8540 MSR)     2-8

line configuration
for ATM switch router (Catalyst 8540 MSR)     3-2

line configuration mode
description (Catalyst 8510 MSR and LightStream 1010)     2-8
description (Catalyst 8540 MSR)     2-8
table     2-3

linecode command     17-12

link distance
configuring     8-29
displaying configuration     8-29

list command     14-5

LMI
displaying statistics on port adapters with NNI interface, example     19-13, 19-14, 19-15

LMI keepalive interval
configuring     19-13

LMI polling intervals
changing, example     19-14

load-interval commands     4-3

logging command     4-3

login authentication command     4-4

loopback interfaces
configuring for tag switching     15-3
configuring, example     15-3
displaying configuration, example     15-4

M


MAC address
adding to BOOTP configuration file     3-4
in LANE ATM address     13-3

main-cpu command     3-27

map list
configuration     12-9
example     12-8, 12-10

map-class command
entering command mode with     2-9

map-class configuration mode
description     2-9
table     2-3

map-group command     12-7, 12-9

map-list command     12-8, 12-9
entering command mode with     2-9

map-list configuration     12-7

map-list configuration mode
description     2-9
table     2-3

masks
implicit in IP access lists, example     11-11

max-admin-weight-percentage command     10-33

maximum burst size
See MBS

maximum queue size
configuring (Catalyst 8510 MSR and LightStream 1010)     8-18

max-records command     16-16

MBS
configuring ATM default     8-33
displaying configuration     8-34

mdl command     19-4

messages
access list violation     11-9
logging     11-9

min-age command     14-7

modem support
configuration (Catalyst 8510 MSR and LightStream 1010)     4-2
configuration (Catalyst 8540 MSR)     4-1

modes
See command modes

MSRP
on ATM switches     1-2

multipoint-to-point funnel signalling     16-26

multiservice switch route processors
See MSRP

N


name command
ELAN     13-10, 13-11
node name     10-18

name server-atm-address command     13-10, 13-11, 13-12, 13-16

NCDP
configuring     3-12
considerations     3-14
enabling     3-15
optimized, figure     3-15
synchronized, figure     3-13

ncdp
command     3-16

ncdp max-diameter
command     3-16

ncdp revertive command     3-16

ncdp source priority command     3-16

NEs
cell flows and     6-1

netmask address
configuration prerequisite     3-2

Network Clock Distribution Protocol
See NCDP

network clocking
configuring NCDP     3-12
configuring sources and priorities (Catalyst 8510 MSR and LightStream 1010)     3-10
configuring sources and priorities (Catalyst 8540 MSR)     3-9
configuring transmit source     3-10
displaying configuration     3-11

network command     15-5

network configuration
figure     7-2

network connectivity
checking (Catalyst 8510 MSR and LightStream 1010)     6-5
checking (Catalyst 8540 MSR)     6-4

network elements
See NEs

network management interface
description (Catalyst 8510 MSR and LightStream 1010)     8-2
description (Catalyst 8540 MSR)     8-1

network routing
configuring     3-23

network service access point
See NSAP address

network service access point addresses
See NSAP addresses

Network Time protocol
See NTP

network-clock-select bits command (Catalyst 8540 MSR)     3-9

network-clock-select command     17-9, 17-12

network-clock-select command (Catalyst 8510 MSR and LightStream 1010)     3-10

network-clock-select command (Catalyst 8540 MSR)     3-9

Network-to-Network Interface
See NNI

next-node command     10-36

NNI     9-1

nodal-representation command     10-49

node 1 disable command     10-10

node 1 level enable command     10-10

node command     10-18
aggregation mode     10-46
complex node representation for LGNs     10-49
entering command mode with     2-10
hello, database sync, and flooding     10-50
LGN and peer group ID     10-16
node election leadership priority     10-20
parent node     10-19
redistribution     10-43
scope mapping     10-15
significant change threshold     10-47
summary address     10-13, 10-22
transit restriction     10-42

non-default well-known PVCs
configuring     5-25

NSAP addresses
configuring     9-2
hierarchical addressing model     3-5

NTP     4-8

ntp command     4-8

NVRAM
storing configurations in     3-31

O


OAM
ATM switch hardware support for     6-2
cell flow support     6-1
commands for configuring functions     6-3
configuring for entire switch (Catalyst 8510 MSR and LightStream 1010)     6-3
configuring for entire switch (Catalyst 8540 MSR)     6-3
configuring interface level     6-4
disabled     6-2
fault management function, note     6-1
in interface configuration command mode     6-4
maximum configured connections (Catalyst 8510 MSR and LightStream 1010)     6-3
maximum configured connections (Catalyst 8540 MSR)     6-3
overview     6-1
switch component operations     6-2

OAM configuration
displaying     6-6
displaying, example     6-7

OAM connections
configuring maximum, example (Catalyst 8510 MSR and LightStream 1010)     6-4
configuring maximum, example (Catalyst 8540 MSR)     6-3

OAM software
capabilities     6-2

OC-12 interface
configuration     17-6
modifying default configuration     17-7

OC-3c
configuration     17-6
defaults     17-5
interface configuration     17-5

OC-3c interface
changing mode of operation     3-6
configuration     17-3
displaying configuration     3-6
modifying default configuration     3-5

Operation, Administration, and Maintenance
See OAM

OSF
configuring (Catalyst 8510 MSR and LightStream 1010)     8-7

OSI     9-2

OSPF
configuring, example     15-6
displaying configuration of, example     15-6

OSPF protocol
displaying configuration of     15-6

outgoing-port atm command     16-16

output pacing
configuration     8-23
configuring     8-23
displaying configuration     8-23

output queue maximum size
displaying configuration (Catalyst 8510 MSR and LightStream 1010)     8-19

output virtual circuit
See OVC

OVC     8-26

oversubscription factor

See OSF

P


packet discard     16-2

parallel interfaces
unnumbering, note     15-4

parent command     10-19

passwords
setting     2-5

PBX     18-1, 18-8

peer group I     9-2

permanent virtual channels
See PVCs

permanent virtual path connection
See PVP

permanent virtual path numbers
See PVP numbers

physical interface
configuring     8-18
See PIF

PIF     15-13

ping atm command     17-13

ping atm interface atm command (Catalyst 8510 MSR and LightStream 1010)     4-15, 6-5

ping atm interface atm command (Catalyst 8540 MSR)     4-15, 6-4

ping destinations
in ATM connections (Catalyst 8510 MSR and LightStream 1010)     6-5

ping ip command     3-8, 3-37

PNNI     7-8, 9-1, 10-1
commands used to configure routing     2-10
hierarchical addressing model of peer groups     3-5

PNNI explicit path
configuration     10-36
displaying     5-18

PNNI explicit paths
description     10-35

PNNI explicit-path configuration mode
table     2-3

PNNI interfaces
configuring static routes as, note     3-23

PNNI link selection
configuration     10-31
methods, table     10-31

PNNI node configuration mode
description     2-10
table     2-3

PNNI node ID     9-2

pnni-remote-exterior-metrics command     10-34

pnni-remote-internal command     10-34

point-to-multipoint
configuring PVC connections     5-9

port adapter
ATM switch support for (LightStream 1010 and Catalyst 8510 MSR)     1-3
CES/T1 and E1     17-2, 18-1
DS3 and E3     17-8
on carrier modules (LightStream 1010 and Catalyst 8510 MSR)     1-2
overview     17-1
T1 and E1     17-10

port select group     14-14

ports
configuring for VP tunnels     15-11

power-on diagnostics
testing     3-35

precedence command     10-34

primary reference source
See PRS

private branch exchange
See PBX

Private Network-Network Interface
See PNNI

privilege command     4-7

privileged EXEC mode
description     2-5
security level of     2-1
table     2-2
See also EXEC mode

prompts
angle bracket in     2-4
pound sign in     2-5
rommon>, note     3-3
system     2-2, 2-4

protocol addresses
commands used for mapping     2-9

PRS     3-12

ptse significant-change command     10-47, 10-51

public VP tunnel network
figure     7-11

purge command     16-16

PVCs
configuring     5-3, 5-10
configuring endpoints to PVP tunnels     7-19
configuring soft     5-15
configuring soft, route optimization     5-23
configuring terminating     5-6
configuring, note     5-3
example     5-3, 5-7, 5-10
traffic values in CTT data structure     8-11

PVP numbers
on VP tunnels, note     15-7

PVP tunnels
in configuring PVCs     7-19

PVPs
configuring     5-13
connecting     15-11
description     5-7
example     5-8, 5-13

Q


QoS     15-13
ATM Forum Class A     3-23

quality of service
See QoS

R


rate scheduler
See RS

RCAC
description     8-2
description (Catalyst 8510 MSR and LightStream 1010)     8-2

RDI functions
cell flows and     6-1

redistribute atm-static command     10-43

redundancy
configuring     3-24
configuring route processors     3-25, 3-27, 3-28, 3-29, 3-30
displaying route processor configuration     3-28, 3-29
simple server     13-3

redundancy command     3-27, 3-28, 3-29, 3-30
entering command mode with     2-14

redundancy configuration mode
description     2-14
table     2-4

redundancy force-failover main-cpu command     3-25

relative weight
configuring     15-15
description     15-15

relay functions
of ATM switch hardware     6-2

remote defect indication functions
See RDI functions

Remote Monitoring
See RMON

remote-log command     14-12

reprogram command (Catalyst 8540 MSR)     20-5

reprogram command (LightStream 1010 and Catalyst 8510 MSR)     20-8

resource call admission control
See RCAC

resource management
See RM

resource-poll-interval command     10-52

RFC 1577     9-1

RFC 1757     14-13

RM
functions (Catalyst 8510 MSR and LightStream 1010)     8-2
functions (Catalyst 8540 MSR)     8-1
overview     8-1

RMON     14-13
configuring     3-31

rmon alarm command     14-18

rmon event command     14-17

ROM monitor mode
table     2-2

rommon> prompt
recovering from, note     3-3

route processor redundancy
configuring     3-25, 3-27, 3-28, 3-29, 3-30

route processors
displaying redundancy configuration     3-28, 3-29
forcing a switchover     3-25
synchronizing configurations     3-27

router command     15-5

router configuration mode
See ATM router configuration mode

routing table
adding entries for Telnet station or SNMP network management workstation, note     3-1

RS      8-26, 15-13

S


scheduler and service class
configuring     8-26

scheduler command     4-5

scope command     16-16

scope map command     10-15

scope mode command     10-15

SCR
configuring margin factor     8-13
displaying margin configuration     8-13

scrambling command     17-4, 17-6, 17-7, 17-10, 17-12

security
in user interface     2-1
See also authentication

segment end point
in ATM switches     6-2

segment loopback flow
checking with ping command, example (LightStream 1010 and Catalyst 8510 MSR)     6-6
checking with ping command, example of (Catalyst 8540 MSR)     6-5

segment loopbacks
effect of ping command on unenabled, note (LightStream 1010 and Catalyst 8510 MSR)     6-6
enabling, example (Catalyst 8510 MSR and LightStream 1010)     6-3
enabling, example (Catalyst 8540 MSR)     6-3
ping of neighbor switch with (Catalyst 8510 MSR and LightStream 1010)     6-5

segment-target command
commands
segment-target     10-36

serial interface
See Frame Relay serial interface

servers
simple server redundancy     13-3

service categories and TBR classes, table     15-14

service category
configuring support     8-36
displaying     8-37
restrictions     8-37

service category limit
configuring (Catalyst 8510 MSR and LightStream 1010)     8-8
displaying configuration (Catalyst 8510 MSR and LightStream 1010)     8-8

service class
configuring     8-26
displaying information     8-28

service command     4-5

Service IWF
configuring a PVC, example     19-24

service-category command     16-16

SGCP
configuring     18-34
configuring call agents     18-39
configuring CES circuits     18-35
configuring request handling     18-38
displaying configuration     18-35
displaying connections     18-38
displaying endpoints     18-37
operation     18-34
shutdown     18-39

sgcp call-agent command     18-39

sgcp command     18-35

sgcp graceful-shutdown command     18-39

sgcp request retries command     18-38

sgcp request timeout command     18-38

ships in the night
See SIN

show atm accounting command     14-6, 14-8, 14-9, 14-10, 14-13

show atm address command     9-5, 9-7, 19-28, 19-30, 19-32

show atm addresses command     5-15, 10-6, 10-10, 17-13

show atm arp-server command     12-5

show atm filter-expr command     11-6

show atm filter-set command     11-6

show atm ilmi-configuration command     9-5

show atm ilmi-status atm command     7-21, 9-8

show atm ilmi-status command     8-17, 8-34, 9-5

show atm int resource command     8-28

show atm interface atm command     5-24, 7-3, 7-4, 7-6, 7-7, 7-9, 7-12, 7-21, 16-7, 16-12, 16-14, 19-35

show atm interface command     5-3, 7-18

show atm interface rm atm command     8-23, 8-25, 8-29, 8-31, 8-37

show atm interface rm command     8-33

show atm interface rm command (Catalyst 8510 MSR and LightStream 1010)     8-19

show atm map command     12-5, 12-6, 12-8, 12-10

show atm pnni aggregation link command     10-46

show atm pnni aggregation node command     10-46, 10-50

show atm pnni background status command     10-29

show atm pnni background-routes command     10-29

show atm pnni command     10-18, 10-19, 10-41, 14-4, 14-6, 14-8, 14-9, 14-11, 16-7

show atm pnni election command     10-20

show atm pnni election peers command     10-20

show atm pnni explicit-paths     10-38

show atm pnni hierarchy command     10-19

show atm pnni identifier     10-37

show atm pnni interface atm command     10-45

show atm pnni interface command     10-42

show atm pnni local-node command     10-10, 10-17, 10-18, 10-33, 10-41, 10-42, 10-44, 10-51

show atm pnni neighbor command     10-32

show atm pnni precedence command     10-35

show atm pnni resource-info command     10-48, 10-52

show atm pnni scope command     10-15

show atm pnni statistics command     10-54

show atm pnni summary command     10-13, 10-22

show atm pnni topology node     10-37

show atm pnni topology node command     10-37

show atm qos command     8-6

show atm resource command     8-7, 8-13

show atm resource command (Catalyst 8510 MSR and LightStream 1010)     8-8, 8-9

show atm rmon command     14-15

show atm rmon host command     14-15

show atm rmon stats command     14-15

show atm route command     10-8, 10-12, 16-7

show atm signalling cug command     16-23

show atm signalling diagnostics filter command     16-18

show atm signalling diagnostics record command     16-18

show atm signalling diagnostics status command     16-18

show atm signalling statistics command     16-24

show atm snoop command     5-30

show atm snoop-vc command     5-31

show atm snoop-vp command     5-31

show atm status command     16-27, 17-13

show atm vc cast mp2p command     16-27

show atm vc command     5-3, 5-16, 17-13

show atm vc interface atm command     5-7, 5-11, 5-16, 7-14, 7-17, 7-20

show atm vc interface command     5-18

show atm vp command     5-8, 5-13, 5-21, 15-11

show calendar command     4-11

show capability command     3-30

show cdp command     4-3

show ces address command     18-9, 18-13, 18-16, 18-20, 18-22, 18-24, 18-27, 18-30, 18-32

show ces circuit command     18-9, 18-14, 18-15, 18-16, 18-20, 18-24, 18-27, 18-32

show ces circuit interface command     18-6, 18-9, 18-11, 18-14, 18-20, 18-22, 18-24, 18-27, 18-31, 18-32, 18-34

show clock command     4-11

show controller e1 command     19-9

show controller t3 command     19-5

show controllers atm command     3-6

show controllers command     3-11, 17-13

show environment command     4-15

show frame relay connection-traffic-table command     19-17

show frame-relay interface resource serial command     19-18

show frame-relay lmi command     19-13, 19-15, 19-17

show functional-image-info command (Catalyst 8540 MSR)     20-6

show functional-image-info command (LightStream 1010 and Catalyst 8510 MSR)     20-8

show hardware command     17-13

show interface command     17-13

show interface ethernet command     17-13

show interface ethernet0 command     3-8

show interfaces serial command     19-11, 19-14

show ip ospf command     15-6

show lane bus command     13-18

show lane client command     13-18

show lane command     13-18

show lane config command     13-18

show lane database command     13-18

show lane default-atm addresses command     13-8

show lane le-arp command     13-18

show lane server command     13-18

show ncdp path root command     3-17

show ncdp ports command
commands
show ncdp ports     3-17

show ncdp sources command     3-17

show ncdp status command     3-17

show ncdp timers command     3-17

show network-clocks command     3-11

show privilege command     4-7

show processes command     4-14

show protocols command     4-14

show redundancy command     3-26, 3-28, 3-29

show rmon alarms events command     14-18

show rmon events command     14-17, 14-18

show running-config command     17-13

show sgcp command     18-35

show sgcp connection command     18-38

show sgcp endpoint command     18-37

show stacks command     4-15

show startup-config command     17-13

show tag-switching atm-tdp capability command     15-13

show tag-switching interfaces command     15-5

show tag-switching interfaces detail command     15-7, 15-9

show vc command     19-21, 19-24, 19-25, 19-33

show vc interface serial command     19-28

show version command     17-13

signalling
disabling     16-25
multipoint-to-point funnel     16-26

Simple Gateway Control Protocol
See SGCP

simple server redundancy
configuring     13-15
description     13-3

Simple Server Redundancy Protocol
See SSRP

SIN     15-13

SNMP     14-2
configuring     3-31
description     3-31
management, enabling     3-31

snmp-server command     4-6

snmp-server enable traps atm-accounting command     14-11

snmp-server host commands     14-11

snoop test ports (Catalyst 8510 MSR and LightStream 1010)     5-28

snooping
configuring     5-28
description     5-28

soft permanent virtual path
See soft PVPs

soft PVCs
configuring     5-15
example     5-16
route optimization configuration     5-23, 19-34

soft PVPs
example     5-20

software
testing for version     3-34
verifying     3-3

sonet command     17-4, 17-7

sonet stm-1 command     3-6

SP     8-4

SSRP     9-3, 13-15

static routes
configuring for IISP or PNNI     3-23
PNNI     10-7, 10-11, 10-12

static-local-exterior command     10-34

static-local-exterior-metrics command     10-34

static-local-internal-metrics command     10-34

statistics command     10-53

status command     16-16

stop-only tacacs+ command     4-14

strict priority
See SP

STS-stream scrambling
disabling     3-6

subinterface configuration mode
description     2-7
table     2-2

subinterfaces
rules for assigning LANE components     13-5

subnetting
mask bits     3-7

summary-address command     10-13, 10-22

sustainable cell rate
See SCR

SVC
CTTs in     8-11

SVC frame discard
configuration     16-2

switch processors
configuring EHSA     3-30
displaying EHSA configuration     3-30
establishing spare card     3-30
installing in chassis, note (LightStream 1010 and Catalyst 8510 MSR)     1-2

switch router
switching EHSA operation     3-29

switch-card redundant command     3-30

switches
configuring OAM (Catalyst 8510 MSR and LightStream 1010)     6-3
configuring OAM (Catalyst 8540 MSR)     6-3
OAM operation     6-2

sync command     3-27

system availability
ATM switch router (Catalyst 8540 MSR)     1-4

system prompts     2-2, 2-4

system redundancy
configuring     3-24

system requirements
for tag switching (Catalyst 8510 MSR and LightStream 1010)     15-2
for tag switching (Catalyst 8540 MSR)     15-2

T


T1 channels
configuring time slots 1 through 5, example     19-5
time slot groupings, note     19-5

t1 command     19-5

T1 default interface
configuring     17-11

T1 line
configuration     19-5
defaults     19-4
description     19-3

T1 trunk
configuration     17-10

T3 trunk
demultiplexes     19-3
description     19-3

TACACS
description     4-11

TACACS and XTACACS
enabling     4-13

tag switching
configuring CoS     15-13
configuring loopback interfaces     15-3
configuring on VP tunnels     15-9
configuring overview     15-2
displaying configuration on ATM interfaces, example     15-5
enabling on ATM interfaces     15-4
example configuration     15-17
overview     15-1
system requirements for tag switching (Catalyst 8510 MSR and LightStream 1010)     15-2
system requirements for tag switching (Catalyst 8540 MSR)     15-2

tag virtual channels
See TVCs

tag-switching atm control-vc command     5-26, 15-8

tag-switching atm vpi command     15-7

tag-switching ip command     15-4, 15-8, 15-10

TDP control channels
between source switches and destination switches, figure     15-8
changing default     15-8
configuring     15-8
configuring on destination switches, example     15-9
configuring on source switches, example     15-9
displaying configuration     15-9
displaying configuration, example     15-9

TDP identifiers
loopback interface as     15-3

TDP sessions
troubleshooting     15-9

template alias
configuring     11-2

terminal
access control, establishing     4-11

Terminal Access Controller Access Control System
See TACACS

terminal line
configuration (Catalyst 8510 MSR and LightStream 1010)     4-2
configuration (Catalyst 8540 MSR)     4-1

testing
ATM address configuration     3-36
ATM connectivity     3-37
ATM interface configuration     3-37
ATM interface status     3-38
configuration of NVRAM configuration     3-41
configuration register installation     3-34
configurations     3-32
Ethernet connection     3-37
Ethernet interface configuration     3-36
hardware installation and configuration (Catalyst 8540 MSR)     3-33
initial IP configuration     3-37
power-on diagnostics     3-35
running configuration     3-40
software versions and type     3-34
VC connections     3-38
See also troubleshooting

tftp-server atm-accounting command     14-12

threshold group description     15-16

threshold groups
configuring     8-14
displaying configuration     8-17

timer command     10-51

trace command     4-15

traffic parameters
configuring interface maximum     8-32
displaying interface maximum configuration     8-33

transit-restricted command     10-42

troubleshooting
interface configuration     17-13
TDP sessions     15-9
See also testing

TVCs
CAC     15-17
creating     15-8
CTT row     15-17
displaying     15-15
threshold group     15-16

U


UBR
configuring limits of best-effort connections     8-30

UNI     9-1

UNI interface
configuring static routes for     3-23

uniqueness rule
of ATM addresses, note     3-5

unprivileged user mode
See user EXEC mode

unshielded twisted-pair
See UTP

unstructured CBR services     18-8

user EXEC mode
security level of     2-1
table     2-2
See also EXEC command mode

user interface
overview     2-1

username command     4-6

UTP     18-2
on ATM switches     1-2

V


VC merge
configuring     15-12
disabling (Catalyst 8510 MSR and LightStream 1010)     15-13
disabling (Catalyst 8540 MSR)     15-12
displaying configuration     15-13
displaying configuration on ATM interface, example     15-13
feature card requirements (Catalyst 8510 MSR and LightStream 1010)     15-12
feature card requirements (Catalyst 8540 MSR)     15-12

VCC
checking end-to-end loopback flow with ping command, example (Catalyst 8540 MSR)     6-5
checking end-to-end loopback flow with ping command, example (LightStream 1010 and Catalyst 8510 MSR)     6-6
checking with ping command, example (LightStream 1010 and Catalyst 8510 MSR)     6-6
checking with ping command, example of (Catalyst 8540 MSR)     6-5

VCs
configuring for Frame Relay/ATM     19-19
supported     5-2
testing connections     3-38

virtual connections
See VCs

virtual path identifier range
See VPI range

virtual path identifiers
See VPI values

virtual terminal lines
settings on     11-10

VP tunnels
between source switches and destination switches, figure     15-10
configuring between switches, examples     15-10
configuring intermediate switches, figure     15-11
configuring PVP 51 on ATM interface, example     15-11
configuring tag switching on     15-9
confirming deletion     7-18
connecting     15-11
connecting PVPs on ATM interface, example     15-12
deleting     7-18
displaying configuration     7-12, 15-11, 15-12
signalling VPCI     7-18

VPI range
change default tag     15-7
changing default TDP     15-8
configuring     15-7
displaying tag switching     15-7
maximum, note     15-7
on VP tunnels, note     15-7
selecting range of three, example     15-7
selecting range of two, example     15-7
showing tag switching VPI range, example     15-8

VPI values
using to configure OAM operations     6-4

W


wait-start tacacs+ command     4-14

Web
CCO-supported interfaces     xxiii
documentation on     xix

weighted-round-robin
See WRR

well-known VCs     5-25

wildcards
in LANE address templates     13-4

WRR     8-27, 15-13

hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Aug 16 14:16:39 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.