The commands shown in this chapter apply to the Catalyst 8540 MSR, Catalyst 8510 MSR, and LightStream 1010. Where an entire command or certain attributes of a command have values specific to a particular switch, an exception is indicated by the following callouts:
To enable online diagnostics on the primary or secondary route processor, use the online-diags command. To disable, use the no form of this command.
online-diags {primary | secondary}
primary | Selects the route processor configured as primary. |
secondary | Selects the route processor configured as secondary. |
Enabled on both primary and secondary route processors.
Privileged EXEC
Enabling the online-diags command runs online diagnostic background tests on the system hardware. Online diagnostics report any hardware failures as soon as they are found. Online diagnostics do use some route processor time.
The following example enables online diagnostics for the primary route processor.
Switch# online-diags primary online-diags is enabled on primary route processor.
To filter ATM signalling call failure based on the outgoing interface rejected call, use the outgoing-port ATM signalling diagnostics configuration command. To return the outgoing port to the default, use the no form of this command.
outgoing-port [atm card/subcard/port]
card/subcard/port | Specifies the card, subcard, and port of the ATM interface. The card number is displayed using the show interface command.The subcard number can be either 0 or 1. |
0
ATM signalling diagnostics configuration
The default 0 means the incoming interface is not considered during filtering.
The following example shows the outgoing-port command.
Switch# configure terminal Switch(config)# outgoing-port ATM 0/1/1
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Aug 16 14:34:40 PDT 1999