This document lists Catalyst 8540 interface modules and cards and the minimum FPGA images required for them. Refer to the individual field-programmable gate array (FPGA) image release notes and the ATM Switch Router Software Configuration Guide for more information about how to update FPGA images.
The FPGA images are available on CCO at:
Catalyst 8540 CSR FPGA images: http://cco/cgi-bin/tablebuild.pl/cat8540c-fpga
Catalyst 8540 MSR FPGA images: http://cco/cgi-bin/tablebuild.pl/cat8540m-fpga
Table 1 lists interface modules and cards and the minimum FPGA versions required for them.
![]() |
Note Use the reprogram command to update the FPGA image. |
| Catalyst 8540 Layer 3 Common Equipment | ||||
| Product Number | Product Description | Notes | Minimum Version Supported | |
C8541CSR-RP | Catalyst 8540 CSR Route Processor | The RP module has two reprogrammable components, the FPGA image and the ROMMON image. Each has its own version | FPGA | 4.8 |
Rommon | 25 | |||
C8542CSR-SP | Catalyst 8540 CSR Switch Processor |
| 1.2 | |
| Catalyst 8540 Multiservice Switched Common Equipment | ||||
| Product Number | Product Description | Notes | Minimum Version Supported | |
C8545MSR-MRP4CLK | C8540 MSR Multiservice Route Processor | The RP module has two reprogrammable components, the FPGA image and the ROMMON image. Each has its own version | FPGA | 4.8 |
Rommon | 25 | |||
C8545MSR-MRP3CLK | C8540 MSR Route Processor Stratum 3 | The RP module has two reprogrammable components, the FPGA image and the ROMMON image. Each has its own version. | FPGA | 4.8 |
Rommon | 25 | |||
This RP module also has an installed Stratum 3 Clock Module daughter card. | Stratum 3 Network Clock Module | 8.0 | ||
C8546MSR-MSP-FCL | C8540 MSR Switch Processor with ATM FC | This SP module consists of a Switch Processor mother board with an installed ATM Feature Card daughter card. | Switch Processor | 1.5 |
ATM Feature Card | 4.17 | |||
UPG-MSR-MRP-3CLK | C8540 MSR - MRP Stratum 3 Clock |
| 8.0 | |
| Catalyst 8540 Layer 3 Interface Modules | ||||
| Product Number | Product Description | Notes | Minimum Version Supported | |
C85GE-2X-16K | C8540 2-port GE 16K | These modules use the same image. | 2.3 | |
C85GE-2X-64K | C8540 2-port GE 64K | |||
C85GE-2XACL-16K | C8540 2-port GE with ACL 16K | These modules use the same images. They consist of a 2-port GE mother board with an installed ACL daughter card. | 2-port GE mother board | 2.3 |
C85GE-2XACL-64K | C8540 2-port GE with ACL 64K | ACL daughter card | 1.0 | |
C85FE-16T-16K | C8540 16-port 10/100 RJ-45 16K | These modules use the same image. | 16-port UTP motherboard | 2.3 |
C85FE-16T-64K | C8540 16-port 10/100 RJ-45 64K | |||
C85FE-16TACL-16K | C8540 16-port 10/100 RJ45 w/ ACL 16K | ACL daughter card | 1.0 | |
C85FE-16TACL-64K | C8540 16-port 10/100 RJ45 w/ ACL 64K | |||
C85FE-16F-16K | C8540 16-port 100-FX MT-RJ 16K | These modules use the same images. They consist of a 16-port FE mother board with an installed ACL daughter card. | 16-port FE mother board | 3.3 |
C85FE-16F-64K | C8540 16-port 100-FX MT-RJ 64K | |||
C85FE-16FACL-16K | C8540 16-port 100-FX MT-RJ w/ ACL 16K | ACL daughter card | 1.0 | |
C85FE-16FACL-64K | C8540 16-port 100-FX MT-RJ w/ ACL 64K | |||
C85GE-8X-64K | C8540 8-port GE Module 64K |
| 1.79 | |
C8540-ACL | Catalyst 8540 Access Control List Daughter Card |
| 1.0 | |
| Catalyst 8540 ATM Interface Modules | ||||
| Product Number | Product Description | Notes | Minimum Version Supported | |
C85MS-16F-OC3MM | Cat 8540 MSR 16-port OC-3 MMF | This module consists of a mother board with an installed 16-port OC3 daughter card | mother board | 5.5 |
16-port OC3 daughter card | 1.21 | |||
C85MS-4F-OC12MM | C8540 4-port OC-12 MMF | These modules use the same images. They consist of a mother board with an installed 4-port OC12 daughter card | mother board | 5.4 |
C85MS-4F-OC12SS | 8540 MSR 4-port OC-12 SMF Intermediate Reach | 4-port OC12 daughter card | 5.2 | |
C85MS-1F4S-OC48SS | C8540 1-port OC-48c SMF-IR + 4 x OC-12 SMF-IR | These modules use the same images. They consist of two mother boards with an installed 4-port OC12c daughter card and an installed 1-port OC48c daughter card. | mother board | 10.2 |
C85MS-1F4M-OC48SS | C8540 1-port OC-48c SMF-IR + 4 x OC-12 MMF | 4-port OC12c daughter card | 5.2 | |
C85MS-1F4S-OC48LR | C8540 1-port OC-48c SMF-LR + 4 x OC-12 SMF | 1-port OC48c daughter card | 1.3 | |
C85MS-2F-OC48SS | C8540 2-port OC-48c SMF-IR | This modules consists of 2 mother boards with two installed 1-port OC48c daughter cards. | mother board | 10.2 |
C85MS-2F-OC48LR | C8540 2-port OC-48c SMF-LR | 1-port OC48c daughter card | 1.3 | |
C85MS-8TI-IMA | 8-port T1 IMA port adapter | These modules use the same images | FPGA | 3.2 |
C85MS-8E1-IMA | 8-port E1 IMA port adapter | Carrier module | 1.8 | |
C85MS-4E1-FRRJ48 | 4-port CE1 Frame Relay port adapter |
|
| 3.3 |
C85MS-1DS3-FRBNC | 1-port CDS3 Frame Relay port adapter |
|
| 4.2 |
| Catalyst 8540 ATM Carrier Modules (required for PAMs) | ||||
| Product Number | Product Description | Notes | Minimum Version Supported | |
C85MS-SCAM-2P | C8540 SuperCAM for Port Adapter Modules (PAMs) |
| 1.8 | |
| Catalyst 8540 ATM Router Module | ||||
| Product Number | Product Description | Notes | Minimum Version Supported | |
C8540-ARM- | C8540 ATM Router Module |
|
| 2.4 |
C8540-ARM-64K | C8540 ATM Router Module 64K |
|
| 2.4 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Aug 25 09:42:04 PDT 2000