Replacing Components

| Transceiver Speed | Cable Type | Max. Distance Between Stations |
|---|---|---|
10/100-Mbps Ethernet | Category 5 UTP | 328 feet (100 m) |
100-Mbps Ethernet | Multimode fiber | 1640 feet (500 m) |
1000-Mbps Ethernet | Multimode fiber | 1640 feet (500 m) |
1000-Mbps Ethernet | Single-mode fiber | 16404 feet (5 km) |
25-Mbps ATM | Category 5 UTP | 328 feet (100 m) |
155-Mbps ATM | Single-mode fiber | 9 miles (15 km) |
155-Mbps ATM | Single-mode fiber, long reach | 18 miles (30 km) |
155-Mbps ATM | Multimode fiber | 1.2 miles (2 km) |
622-Mbps ATM | Single-mode fiber | 9 miles (15 km) |
622-Mbps ATM | Single-mode fiber, long reach | 25 miles (40 km)1 |
622-Mbps ATM | Multimode fiber | 1640 feet (500 m) |
T1, 1.544-Mbps ATM | Category 5 twisted-pair | 650 feet (198 m) |
E1, 2.048-Mbps ATM | Category 5 twisted-pair and FTP (120 ohm) | 650 feet (198 m) |
E1, 2.048-Mbps ATM | Coaxial cable (75 ohm) | 650 feet (198 m) |
CDS3, 45-Mbps | Coaxial cable | 450 feet (137 m) |
CE1, 2.048-Mbps ATM | Category 5 twisted-pair | 650 feet (198 m) |
CES T1 | Category 5 twisted-pair and FTP | 650 feet (198 m) |
CES E1 | Category 5 twisted-pair and FTP (120 ohm) | 820 feet (248.5 m) |
CES E1 | Coaxial cable (75 ohm) | 650 feet (198 m) |
DS3, 45-Mbps | Coaxial cable | 450 feet (137 m) |
E3, 34-Mbps | Coaxial cable | 1299 feet (396 m) |
| 1If you are attaching a short cable to the 622-Mbps long-reach port adapter, you must add 10 dB of attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors. |
The 10/100 Mbps Ethernet interface module with unshielded twisted-pair (UTP) ports supports RJ-45 connectors.
| Pin | Signal | Description |
|---|---|---|
1 | RXD+ | Receive data + |
2 | RXD- | Receive data - |
3 | NC | No connection |
4 | NC | No connection |
5 | NC | No connection |
6 | NC | No connection |
7 | TXD+ | Transmit data + |
8 | TXD- | Transmit data - |
The T1, E1, CES T1 and CES E1 port adapters support RJ-48c connectors.
| Pin | Description |
|---|---|
1 | Receive ring |
2 | Receive tip |
3 | No connection |
4 | Transmit ring |
5 | Transmit tip |
6 | No connection |
7 | No connection |
8 | No connection |
| Description | Specifications |
|---|---|
Switch and processor capacity | 10-Gbps shared memory, nonblocking switch fabric up to 32 KB frames |
Dimensions (H x W x D) | Chassis: 10.4 x 17.25 x 18.4 in (26.4 x 43.1 x 46.0 cm) Processor card and carrier module: 1.2 x 14.4 x 16 in (3.0 x 36.6 x 40.6 cm) Port adapter: 1.2 x 6.5 x 10 in (3.0 x 16.5 x 25.4 cm) Power supply: 2.7 x 6.0 x 15.3 in (6.9 x 15.2 x 38.9 cm) |
Weight | Empty chassis: 32 lb (15.5 kg) Fully populated chassis: approximately 130 lb (59.09 kg) AC power supply: 11 lb (4.98 kg) DC power supply: 10 lb (4.54 kg) |
Airflow | 95 cfm through the system fan assembly |
Operating temperature | 32 to 104 |
Nonoperating temperature | -40 to 167 |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 10,000 ft (-52 to 3048 m) |
Microprocessor | 100-Mhz MIPS R4700 |
AC total output | 388W maximum |
AC-input voltage | 100-240 VAC wide input with power factor correction |
AC frequency | Auto sensing limits: 100 to 127/200 to 240 VAC, 8/4A, 47 to 63 Hz |
AC current rating | 8/4A with the chassis fully populated |
Power supply load | 376W maximum configuration, 200W typical with max configuration |
DC voltages supplied and steady-state maximum current ratings | System: +5V @ 70A +12V @ 2A +24V @ 0.2A Processor: +5V @ 15A +24V @ 25mA +12V @ 500mA |
| Description | Specifications |
|---|---|
Memory | 8-MB Flash memory SIMM (upgradable to 16 MB) 64-MB DRAM 256-KB boot EPROM 128-KB SRAM No Flash PC card installed by default (accepts 8-, 16-, or 20-MB Intel Series 2+ Flash PC cards) |
Regulatory Compliance | UL 1950 (U.S.A.) CSA 950 (Canada) EN60950 (European Union) IEC 950 (International) AS/NZS 3260 (Australia/New Zealand) TS001:1997 (Australia) 21CFR1040 (Laser - U.S.A.) EN60825 (Laser - European Union) IEC60825 (Laser - International) CE Marking (European Union) FCC Part 15 (CFR 47) Class A (U.S.A.) VCCI Class A with UTP and Class B with FTP cables (Japan) EN55022 Class A with UTP and Class B with FTP cables (European Union) CISPR 22 Class A with UTP and Class B with FTP cables (International) AS/NZS 3548 Class A with UTP and Class B with FTP cables (Australia/New Zealand) |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Sep 25 12:43:38 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.