cc/td/doc/product/aggr/vpn5000/5000sw/conc52x/ref52x
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Link Config

Link Config

This section is used to configure the WAN protocol and connection parameters for a given interface.

configure Link Config WAN slot:port

Syntax Description

WAN slot:port

Ports are numbered starting with 0, so for a module with one port, the port is 0.

  • For theVPN 5008 chassis, slot 0 is the far left slot.

  • For the VPN 5002 chassis, slot 0 is the top slot.

Keywords

After entering the configure command for the section, enter one or more of the following keywords.

Mode = {FrameRelay | PPP | SMDS | Off}

The Mode keyword enables this interface for either FrameRelay, PPP or SMDS as a low-level communications protocol. To disable all activity on this interface, set to Off.

Examples

[ Link Config WAN 0 ]
Mode                     = FrameRelay

Related Commands

Command Description

configure DS3 Interface

Configures DS3 parameters for an interface

configure Frame Relay

Configures Frame Relay parameters for an interface

configure HSSI Interface

Configures HSSI parameters for an interface

configure PPP

Configures PPP parameters for an interface

configure SMDS

Configures SMDS parameters for an interface

show wan

Shows WAN port information


hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Sep 27 10:44:06 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.