This section sets configuration parameters for the specified HSSI WAN interface. The HSSI interface has a data capacity of 44.736 Mbps (referred to as Data Speed 3 or DS3).
configure HSSI Interface WAN slot:port
WAN slot:port | Ports are numbered starting with 0, so for a module with one port, the port is 0.
|
After entering the configure command for the section, enter one or more of the following keywords.
Clocking = {Internal | External} | The Clocking keyword configures whether the interface will use its own internal clock or obtain the clock from the DCE to use for the interface's transmit signal towards the network.
|
CRC = {16bit | 32bit} | The CRC keyword configures whether the DSU will use a 16-bit or 32-bit frame check sequence. Both ends of a DS3 connection must use the same CRC (Cyclical Redundancy Check) setting. The default is 16bit. |
[ HSSI Interface Wan 0:0 ] Clocking = External CRC = 16bit
| Command | Description |
|---|---|
configure Link Config | Configures the interface parameters for a WAN port |
set wan hssi | Sets HSSI port hardware parameters |
show wan | Shows WAN port information |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Sep 27 10:38:15 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.