This section sets configuration parameters for an internal DSU on the specified WAN interface. DS3 digital transmission has a data capacity of 44.736 Mbps (referred to as Data Speed 3 or DS3).
configure DS3 Interface WAN slot:port
WAN slot:port | Ports are numbered starting with 0, so for a module with one port, the port is 0.
|
After entering the configure command for the section, enter one or more of the following keywords.
LineBuildOut = {Short | Long} | The LineBuildOut keyword should be set based on the distance between the device and the DS3 terminal located in your building.
|
Clocking = {Internal | External} | The Clocking keyword configures whether the DSU will use its own internal clock or obtain the clock from the network to use for the DSU's DS3 transmit signal towards the network.
Verify this setting with your ISP. |
DS3SubRate = {3_158 | 6_316 | 9_474 | 12_632 | 15_790 | 18_948 | 22_106 | 25_264 | 28_422 | 31_580 | 34_738 | 37_896 | 41_054 | 44_210} | The DS3SubRate keyword specifies the data rate for the CSU/DSU. This can be used to set the throughput to match the bandwidth provided by your NSP (Network Service Provider). The values are specified in megabits per second, using an underscore ( _ ) as the decimal point (e.g., 3_158 is 3.158 Mbps). Both ends of the DS3 connection must have the same rate specified. Unless the remote end is a Larscom CSU/DSU (or equivalent) or another Cisco Systems DS3 interface, the default setting of 44_210 must be used. |
InvertData = {On | Off} | The InvertData keyword allows the user to invert data. Data inversion can be used to meet pulse density requirements. Always set to Off unless otherwise instructed by your ISP. If a DSU at one end of a DS3 line inverts its data, then the DSU at the other end must do the same. |
CRC = {16bit | 32bit} | The CRC keyword configures whether the DSU will use a 16-bit or 32-bit frame check sequence. Both ends of a DS3 connection must use the same CRC (Cyclical Redundancy Check) setting. The default is 16bit. |
[ DS3 Interface Wan 0:0 ] LineBuildOut = Long CRC = 16bit
| Command | Description |
|---|---|
configure Link Config | Configures the interface parameters for a WAN port |
set wan ds3 | Sets DS3 port hardware parameters |
show wan | Shows WAN port information |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Sep 27 10:35:08 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.