Troubleshooting PREs

Troubleshooting PREs

Troubleshooting PREs

This section describes how to troubleshoot Performance Routing Engines (PREs). It provides information on troubleshooting PRE fault states, the management Ethernet port, and the serial port.

PRE Module Faults

The PRE provides the IP routing and forwarding functionality in the Cisco 10000. Thus, in a non-redundant PRE configuration, a PRE failure is a system failure. A redundant PRE configuration is recommended.

If the PRE fails, the yellow PRE STATUS LED lights. You can try rebooting the Cisco 10000, moving the card to a different PRE slot, or replacing the PRE with another one. In any event, you should capture any error messages that appear on the console, as well as the state of the PRE LEDs and alphanumeric display. Then you should contact the Cisco Technical Assistance Center (TAC).

Figure 3-1 describes the LED indicators on the PRE faceplate. Use these descriptions to verify the operation of the PRE.


Figure 3-1: PRE Faceplate and LEDs


Table 3-1 lists the PRE fault indications and recommended actions. The information contained in the table is based on the assumption that you have a nonredundant configuration.


Table 3-1: PRE Module Fault Indications and Recommended Action
Fault Steps to Take

STATUS LED is not lit

    1. Check LEDs on other modules and cards. If none are lit, refer to Table 2-1 or Table 2-3 depending upon the PEM type in your chassis.

    2. If LEDs on other modules and cards are lit, remove the card from its slot and check for bent or broken pins on the backplane. Return the card to its slot and screw it firmly into place.

    3. Replace the card.

    4. If the problem persists, contact the Cisco TAC.

FAIL LED is yellow, indicating that the PRE failed

    1. Reinsert the PRE.

    2. Insert a new PRE.

    3. If the problem persists, contact the Cisco TAC.

The PRE initializes, but you cannot establish a console connection

    1. Ensure that the terminal settings are properly set.

    2. If you still cannot connect, check the console cable. Is it firmly connected? Is it the correct type of cable with proper connectors?

    3. If the cable checks out and you cannot establish a console or Telnet session, reinsert the PRE module. If the problem persists, replace the PRE.

    4. Enter show log to review console messages recorded in the system log.

Card cannot be fully inserted into its slot

Make sure that you are using slot 0A or 0B for the PRE module.

An alarm LED is lit

    1. Enter the show facility-alarm status command and examine the output to determine which system component raised the alarm.

    2. Troubleshoot using a procedure appropriate to the module or FRU responsible for the alarm. Refer to the following sections for information on interpreting alarms:

Ethernet Connection Problems

If the management Ethernet connection on the Cisco 10000 PRE fails to work properly, and the corresponding Link LED is not lit (steady green)

If the Link LED is lit (steady green), but the Ethernet port is not working properly, make sure that the port in question is configured properly and is not administratively shut down. If you have a working console connection, perform the following steps:


Step 1 At the switch prompt, enter show interface fastethernet0/0/0. If the port is administratively down, enter these commands to enable it:

c10000# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
c10000(config)#interface fastethernet0/0/0
c10000(config-if)# no shut
c10000(config-if)# exit
c10000(config)# exit
c10000# 
 

Step 2 Check that the Ethernet port in question is assigned a valid IP address.

For more information about configuring Ethernet ports, refer to the Cisco 10000 ESR Software Configuration Guide.

If the cable, connections, power, and configuration all check out, and you still cannot connect to the Ethernet port on the module, replace the module in question. If the problem persists, contact the Cisco TAC for further assistance. Refer to the "Obtaining Technical Assistance" section for instructions on contacting the Cisco TAC.


Console Port Serial Connection Problems

If the console screen connected to a Cisco 10000 console port appears frozen or fails to work properly

If the cable, connections, power, and terminal settings all check out and you still cannot connect to the console port on the module, replace the module in question. If the problem persists, contact the Cisco TAC for further assistance.