This publication contains instructions for installing the AC Power Entry Module (PEM) in the Cisco 10000 Edge Services Router (ESR). If you are not familiar with the Cisco 10000 router, see the Cisco 10000 ESR System Description, and the Cisco 10000 ESR Hardware Installation Guide for additional information.
The following sections are included in this configuration guide:
The AC PEM provides power conversion directly from the facility VAC input power (100 VAC to 240 VAC) to the -48V VDC used internally by the system (see Figure 1). AC power is delivered to the AC PEM from the VAC connection power cable to the power cord attached to the PEM.

There are two PEM bays in the chassis; however, you only need one PEM to power the router. You can install an additional PEM for power redundancy.
Before you perform any of the procedures in this guide, Cisco recommends that you:
Before you begin the installation or replacement procedure, review the safety guidelines in this section to avoid injuring yourself or damaging the equipment. Before you install, configure, or perform maintenance on the router, you should also review the safety warnings listed in the Cisco 10000 ESR Hardware Installation Guide.
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement. The following warning is an example of a safety warning. It identifies the warning symbol and associates it with a bodily injury hazard.
![]() |
Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device. |
![]() |
Note If you need translations of the safety warning, see the Cisco 10000 ESR Hardware Installation Guide. |
The Cisco 10000 system is hot-swappable, which means you can remove and replace a defective PEM while the system is operating (assuming that your system has a second AC PEM installed for redundancy). It is not necessary to notify the software or reset the system power. This feature lets you add, remove, or replace a second PEM while the system maintains all routing information and ensures session preservation.
You need the following tools and equipment to install an AC PEM:
This section describes how to add or replace an AC PEM in the Cisco 10000 chassis. It contains the following procedures:
Use the following procedure to remove the front cover from the system. If your system does not use a front cover, go to the "Installing a Second AC PEM" section or to the "Replacing an AC PEM" section.
Repeat this procedure for all four bezel plugs and then remove the plugs.

Step 2 Remove the cover by lifting it up slightly and then pulling it toward you (Figure 3).

Step 3 Continue installing or replacing the AC PEM:
Use the following procedure to install a second AC PEM in the bottom power bay for redundancy.

Step 2 Loosen the captive screws to remove the blank cover from the bottom power bay (Figure 5).

Step 3 Install the new AC PEM all the way into the power bay to ensure a secure connection to the backplane, and then tighten the captive screws (Figure 6).

Step 4 Connect the power cord from the PEM to your power cord that connects to the facility VAC input.
Step 5 Set the AC power cord connectors in a cord strain relief (canoe) to prevent them from accidently disconnecting (Figure 7).

Step 6 Plug the facility AC input power cord into a power receptacle.
Step 7 Set the power switch to the on (|) position (Figure 8).
The (green) power LED on the PEM lights indicating that the PEM is on.

Step 8 Replace the front cover.
Use the following procedure to replace an AC PEM.
![]() |
Note The illustrations in this guide show how to replace the AC PEM from the bottom power bay. The procedure is the same to replace an AC PEM in the top power bay. |

Step 2 Power off the PEM you are replacing (Figure 10).
![]() |
Caution Do not power off both AC PEMs in a redundant system or the system shuts down and all data traffic stops. Only power off the AC PEM you are replacing. |

Step 3 Remove the PEM power cable from its canoe and disconnect it from the AC input power cable (Figure 11).

Step 4 Loosen the captive screws on the PEM and remove the PEM from the chassis using the handle on the faceplate (Figure 12).

Step 5 Install the new PEM all the way into the power bay to ensure a good connection to the backplane, and tighten the captive screws on the PEM (Figure 13).

Step 6 Connect the power cord from the PEM to the power cord that connects to the facility VAC input.
Step 7 Set the AC power cord connectors in a cord strain relief (canoe) to prevent them from accidently disconnecting (Figure 14).

Step 8 Plug the facility AC input power cord into a power receptacle.
Step 9 Set the power switch to the on (|) position (Figure 15).
The (green) power LED on the PEM lights indicating that the PEM is on.

Step 10 Replace the front cover.
Table 1 contains troubleshooting information for the AC PEM:
| Symptom | Description |
|---|---|
System fails to power on | Check that:
|
AC PEM Fault LED is on (yellow) | The PEM is not operating correctly (see the Cisco 10000 ESR Troubleshooting Guide). |
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
![]() |
Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact the Cisco Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com. |
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
Access Registrar, AccessPath, Any to Any, AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, the Cisco Technologies logo, ConnectWay, Fast Step, FireRunner, Follow Me Browsing, FormShare, GigaStack, IGX, Intelligence in the Optical Core, Internet Quotient, IP/VC, Kernel Proxy, MGX, Natural Network Viewer, NetSonar, Network Registrar, the Networkers logo, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RateMUX, ScriptShare, Secure Script, ServiceWay, Shop with Me, SlideCast, SMARTnet, SVX, The Cell, TrafficDirector, TransPath, ViewRunner, Virtual Loop Carrier System, Virtual Voice Line, VlanDirector, Voice LAN, Wavelength Router, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and Aironet, ASIST, BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, FastSwitch, GeoTel, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any of its resellers. (0004R)
Copyright © 2000, Cisco Systems, Inc.
All rights reserved.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Apr 28 08:18:34 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.