This chapter describes installation and upgrade of the Sun Solaris 2.6 operating system, Solaris patches, alarm card software, and Volume Manager software on the hardware platform for your solution. If the above components are already installed, you can skip this chapter and go to "Installing the Cisco Media Gateway Controller Software Release 7.4."
This chapter contains the following sections:
![]() |
Note The procedures in this chapter assume that the system is powered on, with both boot disks (A-DSK0 and B-DSK0) removed and booted to the {O} ok prompt. To power on a CPU, push both tabs outward (away from the center). When you are instructed to power off a CPU in the procedures that follow, pull both tabs on the CPU toward the center. |
![]() |
Note The procedures in this chapter require a working knowledge of the system administration procedures for the Sun Solaris (UNIX) operating system. |
![]() |
Tips Monitor system output frequently for error messages during the installation process and correct any error conditions before continuing with the installation. |
This section provides instructions for installing the operating system on the Sun Netra t 1120, t 1125, t 1400, t 1405, and E450 platforms. There are points in the instructions when the responses you make to prompts depend on the disk drive size or other particulars of your system. These places are pointed out as you go.
This section contains the following procedures:
To boot from a local CD-ROM, perform the following steps:
![]() |
Caution Sun Netra t 112x: During the installation of CD-ROM based software on a Sun Netra t 112X machine, leave the front CD panel open. The CD-ROM drive automatically ejects the CD when finished. If the front panel is closed, damage can occur when the CD is ejected. |
Step 2 If the system is currently running, log in as root and shut it down:
# init 0
Step 3 From the ok prompt, boot the CD-ROM:
{0} ok boot cdrom
If the machine has never had an operating system installed, the following screen appears when the CD-ROM boot is finished:
Boot device: /pci@1f,4000/scsi@3/disk@6,0:f File and args: SunOS Release 5.7 Version Generic_106541-06 [UNIX(R) System V Release 4.0] Copyright (c) 1983-1999, Sun Microsystems, Inc. Solaris Web Start 3.0 installer No frame buffer found. Command line install is available in english only. English has been selected as the language in which to perform the install. Starting the Web Start 3.0 Solaris installer Solaris installer is searching the system's hard disks for a location to place the Solaris installer software. The default root disk is /dev/dsk/c0t0d0. The Solaris installer needs to format /dev/dsk/c0t0d0 to install Solaris. WARNING: ALL INFORMATION ON THE DISK WILL BE ERASED! Do you want to format /dev/dsk/c0t0d0? [y,n,?,q]
If an operating system was previously installed on the machine, text similar to the following appears with two warnings:
Command line install is available in english only. English has been selected as the language in which to perform the install. Starting the Web Start 3.0 Solaris installer Solaris installer is searching the system's hard disks for a location to place the Solaris installer software. This system appears to contain a version of Solaris. The Solaris installer does not allow upgrading. If you choose to use this installer an initial install will be required. Any information on your system's disks could be erased. Would you like to use this installer? [y,n,?]
Step 4 In all of the above cases, type y and press Enter to continue until the following text appears:
Enter a swap partition size between 320Mb and 17269Mb, default = 512Mb [?]
Step 5 Type in 2040 (for 9- and 18-GB disk drives) for swap partition size and press Enter. It is not necessary to enter "Mb" after the number; the system assumes that the entry is in megabytes.
You have selected /dev/dsk/c0t0d0 with a swap size of 2040/320 to be used by the Solaris installer. WARNING: ALL INFORMATION ON THE DISK WILL BE ERASED! Is this OK [y,n,?,q]
Step 6 Begin the installation by typing y and pressing Enter. The system copies the necessary files from the CD-ROM and reboots.
![]() |
Tips This process takes approximately 10 minutes to run and requires no user intervention. |
The following text appears:
Welcome to the Web Start Solaris Command Line installation!
The following questions will gather information about this system.
This information will be used to configure:
Network
Name Service
Date and Time
Root Password
Power Management
<Press Return to continue>
Step 7 Press Enter to continue. The following text appears:
Please enter a host name, which identifies this system on the network. The name must be unique within the domain in which it resides; creating a duplicate host name will cause problems on the network after you install Solaris. A host name must be at least two characters; it can contain letters, digits, and minus signs (-). Enter host name: <host-name>
Step 8 Type the host name of the target Sun Netra machine and press Enter. The following text appears:
Please specify whether your system will be networked. Specify Yes if the system is connected to the network by one of the Solaris or vendor network/communication Ethernet cards that are supported on the Solaris CD. See your hardware documentation for the current list of supported cards. Specify No if the system is connected to a network/communication card that is not supported or not connected to a network. Is this machine networked (y/n) [n]?
Step 9 Type y and press Enter to specify that this machine is networked. The following text appears:
Please enter the Internet Protocol (IP) Address for this system. It must be unique and follow your site's address conventions, or a system/network failure could result. IP Addresses contain four sets of numbers separated by periods (for example 129.200.9.1). Enter this machine's IP Address:
Step 10 Type the IP address assigned to this system in dotted decimal format and press Enter. The following text appears:
Please specify the netmask of your subnet. A default netmask is shown; do not accept the default unless you are sure it is correct for your subnet. A netmask must contain four sets of numbers separated by periods (for example 255.255.255.0). Enter the subnet netmask [255.255.255.0]:
Step 11 Type the IP netmask for the subnet and press Enter.
![]() |
Caution Do not accept the default netmask unless you are sure it is correct for your subnet. |
The following text appears:
Please provide name service information. Select the name service that will be used by this system, or None if your system will either, not use a name service at all, or if it will use a name service not listed here Available name services: 1. NIS+ 2. NIS 3. DNS 4. None Please enter the number corresponding to the type of name service you would like [ ]:
Step 12 Type 4 for None and press Enter. You can specify a default time zone in one of three ways, described by the text that appears:
Please select how to specify your default time zone. Specify Time Zone by: 1. Geographic region 2. Offset from GMT 3. Time zone file Please enter the number corresponding to how you would like to specify the time zone [1]:
Step 13 Type the means of defining your default time zone (1, 2, or 3) and press Enter. The text that follows prompts you for appropriate input until the following message appears:
The default date and time is (current date and time of defined time zone). Do you want to use this date and time (y/n) [y]?
Step 14 Press Enter to accept the date and time information as shown, or type n and press Enter to be prompted for different values. When the information is correct, press Enter again. The following text appears:
Type in an alphanumeric string to be used as the root password for the computer you are setting up. Enter the root password []:
Step 15 Type cisco as the root password and press Enter: The following text appears, prompting you to confirm the root password:
Retype the above password for confirmation. Enter the root password again []:
Step 16 Retype the root password and press Enter. The following text appears:
Do you want Power Management turned on (y/n) [n]?
Step 17 Disable Power Management by typing n and pressing Enter. The following text appears:
You can choose to be asked the preceding question every time you reboot the system. Alternatively, you can choose never to be asked about Power Management again. Ask about Power Management at each reboot (y/n) [n]?
Step 18 Type n and press Enter. The following text appears:
You have entered the following values:
Host Name: host-name
IP Address: IP_address
System part of a subnet: Yes
Netmask: IP_netmask
Name Service: NONE
Time Zone: time_zone
Power Management:
Turn Power Management Off
Do not ask about Power Management at reboot.
Enter 'y' to apply these values and proceed to the next stage of the
installation, or 'n' to return to the beginning and make changes (y/n):
Step 19 Make sure that your values are correct before continuing:
a. If your values are incorrect, type n and press Enter to go back to Step 7.
b. If your values are correct, type y and press Enter to continue to the installation of the Sun Solaris operating system.
This completes the process of booting from a local CD. Continue with the "Loading the Sun Solaris 2.6 Operating System" section .
This section provides the procedure for loading the Sun Solaris 2.6 operating system.
![]() |
Note This procedure covers 9- and 18-GB disk drives. |
keyserv: failed to generate host's netname when establishing root's key. Solaris Web Start will now gather information to install software for Solaris. Please wait while initial values are loaded... Available operating environments: 1. Solaris 2.5.1 Hardware: 11/97 2. Solaris 2.6 5/98 Select the number corresponding to the operating environment you would like to install [1]:
Step 2 Type 2, then press Enter. The following text prompts you to verify your choice:
You have selected: Solaris OS: Solaris 26 Enter 'y' if this is correct, or 'n' if it is incorrect:
Step 3 When the display shows the software that you have chosen, type y and press Enter to accept. The following text appears:
Please insert the Solaris 2.6 CD. <Press Return after the CD has been inserted>
Step 4 The Operating Environment Installation CD automatically ejects from the machine at this time. Remove it from the CD-ROM drive and insert the Sun Solaris 2.6 Operating System CD, then press Enter. The following screen appears:
Reading CD for Solaris 2.6 Please wait while the system is initializing... To install basic Solaris products into their default directory locations, select Default Install. Custom install provides a choice of which Solaris products to install. For each product, it also provides an option to further customize the products install. Types of install available: 1. Default Install 2. Custom Install Select the number corresponding to the type of install you would like [1]:
Step 5 Type 2 for Custom Install, and press Enter. The following text appears:
Select the software localizations you want to install. The English version of Solaris will be installed by default. Enable locale German ( de ) (y/n) [n]?
Step 6 Type n and press Enter. The following text appears:
Enable locale Spanish ( es ) (y/n) [n]?
Step 7 Type n and press Enter. The following text appears:
Enable locale French ( fr ) (y/n) [n]?
Step 8 Type n and press Enter. The following text appears:
Enable locale Italian ( it ) (y/n) [n]?
Step 9 Type n and press Enter. The following text appears:
Enable locale Swedish ( sv ) (y/n) [n]?
Step 10 Type n and press Enter to continue. The following text appears:
Available locales: 1. English (Australia) ( en_AU ) 2. English (Canada) ( en_CA ) 3. English (Ireland) ( en_IE ) 4. English (New Zealand) ( en_NZ ) 5. English (UK) ( en_UK ) 6. English (United States) ( en_US ) 7. English (POSIX C) ( C ) Select the number corresponding to the desired system locale [6]:
Step 11 Type the number corresponding to the appropriate locale and press Enter. The following text appears:
Available software groups: 1. Entire Solaris Software Group Plus OEM 2. Entire Solaris Software Group 3. Developer Solaris Software Group 4. End User Solaris Software Group 5. Core Solaris Software Group Select the number corresponding to the desired Solaris software group [2]:
Step 12 Type 1 for "Entire Solaris Software Group Plus OEM" and press Enter. The following text appears:
Please wait while the system is initializing... Select which disks you want to lay out the file systems on. Required disk space: 2,705 MB
One of the following tables appears, depending on your disk size:
--------------------------------------------- 9 Gbyte disk drive Available Disks Disk Size c0t0d0 8633 MB c0t1d0 8633 MB --------------------------------------------- 18 Gbyte disk drive Available Disks: Disk Size c0t0d0 17269 MB c0t1d0 17269 MB ---------------------------------------------
![]() |
Tips Take note of the disk drive size on the target machine. You will need this number when asked to define the disk partitions in a later step. |
You also see the following prompt:
Enter 'y' to layout file systems on the specified disk. This will erase all existing data on the disk. Enter 'n' to leave the disk unmodified. Layout file systems on disk c0t0d0 (bootdisk) (y/n) [y]?
Step 13 Type y and press Enter to continue. The following text appears:
Layout file systems on disk c0t1d0 (y/n) [n]?
Step 14 Type n and press Enter to continue. The following text appears:
File System operations: 1. Print the current partition table 2. Modify a disk's partition table 3. Done Select the number corresponding to a file system operation, or 'Done' to proceed with the install [3]:
Step 15 Type 2 and press Enter to set up the disk partitions. One of the following tables appears:
---------------------------------------------
9 Gbyte disk drive
Available disks:
1. c0t0d0
/ 668 MB
swap 2040 MB
/export/home 14561 MB
2. c0t1d0 Not Selected
3. Done
---------------------------------------------
18 Gbyte disk drive
Available disks:
1. c0t0d0
/ 667 MB
swap 2040 MB
/export/home 5926 MB
2. c0t1d0 Not Selected
3. Done
---------------------------------------------
You also see the following prompt:
Select a disk to modify, or Done to return to the previous menu [3]:
Step 16 Type 1 to modify the partitions on disk c0t0d0 and press Enter. One of the following tables appears:
--------------------------------------------- 9 Gbyte disk drive Disk Name c0t0d0 TotalSpace 17269 Used Space 17269 Free Space 0 Round Error 0 # Slice Name Slice Size Minimum Size 0. / 668 MB 665 MB 1. swap 2040 MB 2040 MB 3. Unused 4. Unused 5. Unused 6. Unused 7. /export/home 14561 MB 0 MB 8. Done --------------------------------------------- 18 Gbyte disk drive Disk Name c0t0d0 TotalSpace 8633 Used Space 8633 Free Space 0 Round Error 0 # Slice Name Slice Size Minimum Size 0. / 667 MB 665 MB 1. swap 2040 MB 2040 MB 3. Unused 4. Unused 5. Unused 6. Unused 7. /export/home 5926 MB 0 MB 8. Done ---------------------------------------------
Step 17 You also see the following prompt:
Select a slice to modify, or Done to return to the previous menu [8]:
Step 18 Remove partition 7 by typing 7 and pressing Enter. The following text appears:
Enter new slice name:
Step 19 Remove the name associated with partition 7 by pressing Enter. The screen shows that partition 7 is "Unused."
Step 20 Repeat Step 16 through Step 19 for each partition numbered 4 through 6. Use the screen display example in Step 23 for partition names and sizes.
![]() |
Note You defined Partition 1 (swap) in Step 5. |
Step 21 Type the number of the partition to be defined and press Enter. The following text appears:
Enter new slice name:
Step 22 Type the partition name and press Enter. The following text appears:
Enter new slice size (in MB) [default]:
![]() |
Note When defining the partition size, you need not enter "Mb" after the number. The system assumes that the entry is in megabytes. |
Step 23 Type the partition size and press Enter. Each time a partition is defined, the changes are displayed on the screen. The tables below show the end result of defining the drive partitions for each drive size:
--------------------------------------------- 18 Gbyte disk drive Disk Name c0t0d0 TotalSpace 17269 Used Space 17208 Free Space 61 Round Error 0 # Slice Name Slice Size Minimum Size 0. / 668 MB 619 MB 1. swap 2040 MB 2040 MB 3. Unused 4. /opt 11040 MB 25 MB 5. /var 1025 MB 22 MB 6. /usr 2435 MB 0 MB 7. Unused 8. Done --------------------------------------------- 9 Gbyte disk drive Disk Name c0t0d0 TotalSpace 8633 Used Space 8633 Free Space 56 Round Error 0 # Slice Name Slice Size Minimum Size 0. / 665 MB 42 MB 1. swap 2040 MB 2040 MB 3. Unused 4. /opt 2560 MB 25 MB 5. /var 1025 MB 22 MB 6. /usr 2287 MB 578 MB 7. Unused 8. Done --------------------------------------------- Select a slice to modify, or Done to return to the previous menu:
Step 24 To end disk partitioning, type 8 (for 9- and 18-GB disk drives) and press Enter. One of the following tables appears:
---------------------------------------------
9 Gbyte disk drive
Available disks:
1. c0t0d0
/ 665 MB
swap 2040 MB
/opt 2616 MB
/var 1025 MB
/usr 2287 MB
2. c0t1d0 Not Selected
3. Done
---------------------------------------------
18 Gbyte disk drive
Available disks:
1. c0t0d0
/ 668 MB
swap 2040 MB
/opt 11040 MB
/var 1025 MB
/usr 2435 MB
2. c0t1d0 Not Selected
3. Done
---------------------------------------------
Select a disk to modify, or Done to return to the previous menu [3]:
Step 25 Type 3 and press Enter to continue. The following text appears:
File System operations: 1. Print the current partition table 2. Modify a disk's partition table 3. Done Select the number corresponding to a file system operation, or 'Done' to proceed with the install [3]:
Step 26 Type 3 and press Enter to continue. The following text appears:
The following items will be installed: Solaris OS: Solaris 2.6 Software Locales: none System Locale: English (United States) ( en_US ) Solaris Software Group: Entire Solaris Software Group Plus OEM Enter 'y' to accept these values and start the installation, or 'n' to return to the beginning and make changes (y/n):
Step 27 Type y, then press Enter to continue.
The process takes approximately 30 minutes to run and does not require user intervention. The following screen gradually appears:
Installing...
Installing Solaris software group
|-1%------------25%----------------50%----------------75%-------------100%|
Installing Additional Software
|-1%------------25%----------------50%----------------75%-------------100%|
Installation details:
Product Result More Info
1. Solaris 2.6 5/98 Installed Available
2. Additional Software Installed Available
3. Done
Enter the number corresponding to the desired selection for more
information, or Done to continue [3]:
Step 28 Type 3 and press Enter to continue. The following screen appears:
The system needs to reboot to complete installation. <Press Return to reboot>
Step 29 Press Enter to reboot the system.
Step 30 The Sun Solaris Software CD is automatically ejected from the CD-ROM drive. Remove the CD.
Step 31 If you wish to define the default gateway after the system has rebooted, log in as root, type the following command, and press Enter:
# route add default default router IP address 1
![]() |
Note The default router IP address is usually 1 (first gateway), but can be any valid number representing any available gateway. |
Step 32 To make the default gateway permanent, create a file called /etc/defaultrouter and put the default gateway IP address on the first and only line of the file by entering the following command:
# echo default gateway IP address > /etc/defaultrouter
This completes the installation of the Sun Solaris 2.6 operating system. Proceed to the "Installing the Sun Solaris Patches" section. If you have questions or need assistance, see the "Obtaining Technical Assistance" section of the Preface.
In this section, the patch cluster is installed on the target machine.
To install the Sun Solaris 2.6 patches, perform the following steps:
Step 2 Install the Sun Solaris 2.6 software patches by entering the following commands:
# pkgadd -d cdrom/cdrom0/solaris_patches/CSCOh007.pkg
The following screen appears:
The following packages are available:
1 CSCOh007 Virtual Switch Controller Solaris 2.6 patch cluster
(sparc) 1.0(0)E
Select package(s) you wish to process (or 'all' to process
all packages). (default: all) [?,??,q]:
Step 3 Press Enter to accept the default response of all and continue. The following screen appears:
Processing package instance <CSCOh007> from </cdrom/ciscomgc_install/CSCOh007.pkg> Virtual Switch Controller Solaris 2.6 patch cluster (sparc) 1.0(0)E Cisco System, Inc. The selected base directory </opt/sun_install> must exist before installation is attempted. Do you want this directory created now [y,n,?,q]
Step 4 Type y and press Enter to continue. The following text appears:
Using </opt/sun_install> as the package base directory. ## Processing package information. ## Processing system information. 1 package pathname is already properly installed. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. The following files are already installed on the system and are being used by another package: * /opt/sun_install <attribute change only> * - conflict with a file which does not belong to any package. Do you want to install these conflicting files [y,n,?,q]
Step 5 Type y and press Enter to continue. The following text appears:
## Checking for setuid/setgid programs. This package contains scripts which will be executed with super-user permission during the process of installing this package. Do you want to continue with the installation of <CSCOh007> [y,n,?]
Step 6 Type y and press Enter to continue. The following text appears:
Installing Virtual Switch Controller Solaris 2.6 patch cluster as <CSCOh007> ## Executing preinstall script. Platform is SUNW,Ultra-60 NOTICE: Architecture checks passed ## Installing part 1 of 1. /opt/sun_install/checkPackages2.6 /opt/sun_install/checkPatches2.6 /opt/sun_install/installPatches2.6 /opt/sun_install/packages2.6 /opt/sun_install/patch_optional2.6 /opt/sun_install/patch_order2.6 /opt/sun_install/patch_required2.6 /var/tmp/105181-19.tar.Z /var/tmp/105210-27.tar.Z . . /var/tmp/108199-01.tar.Z /var/tmp/108201-01.tar.Z [ verifying class <none> ] ## Executing postinstall script. !! !! You must now change directories to /opt/sun_install and !! run the installPatches2.6 script as root. !! Installation of <CSCOh007> was successful.
Step 7 Complete the installation of the Sun Solaris 2.6 software patches by typing each of the following commands and pressing Enter:
# cd /opt/sun_install # ./installPatches2.6
The following screen appears:
*** InstallPatches2.6 begins Thu Mar 16 10:49:01 GMT 2000 *** Platform is SUNW,Ultra-60 Changed to /var/tmp directory Uncompressing 106125-08 ... Extracting 106125-08 ... Extraction of patch 106125-08 successful Installing 106125-08 ... . . Uncompressing 105591-07 ... Extracting 105591-07 ... Extraction of patch 105591-07 successful Installing 105591-07 ... *** InstallPatches2.6 ends Thu Mar 16 11:07:38 GMT 2000 ***
This completes the installation of the Sun Solaris patches. If you have questions or need assistance, see the "Obtaining Technical Assistance" section of the Preface.
Continue to the "Installing the Alarm Card Software" section.
![]() |
Note The alarm card driver is not part of the standard Sun Solaris installation; you must install it separately. |
To install the alarm card software, perform one of the following steps:
To install the lights out management software, perform the following steps:
Step 2 Enter the following commands:
# cd /cdrom/netra_t_server_lom/Product/ # pkgadd -d . SUNWlomm SUNWlomr SUNWlomu
The following screen appears:
LOMlite manual pages
(sparc.sun4u) 1.1.0,REV=1999.10.20.13.34
Copyright 1999 Sun Microsystems, Inc. All Rights Reserved.
Manufactured in the United States of America.
2550 Garcia Avenue, Mountain View, California, 94043-1100 U.S.A.
Copyright 1999 Sun Microsystems Inc. Tous droits reserves.
Fabrique aux Etats-Unis, 2550 Garcia Avenue, Mountain View, Californie
94043-1100 USA
Lights Out Management manual pages will be installed at this time, followed by installation of the LOMlite driver. The following screen appears:
Using </> as the package base directory. ## Processing package information. ## Processing system information. 5 package pathnames are already properly installed. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. The following files are already installed on the system and are being used by another package: /etc <attribute change only> Do you want to install these conflicting files [y,n,?,q]
Step 3 Select y and press Enter to install all the packages. The following screen appears:
## Checking for setuid/setgid programs. This package contains scripts which will be executed with super-user permission during the process of installing this package. Do you want to continue with the installation of <SUNWlomr> [y,n,?]
Step 4 Select y and press Enter to continue. The following screen appears:
Installing LOMlite driver as <SUNWlomr> ## Installing part 1 of 1. /etc/init.d/lomlited /etc/init.d/tsaldog /kernel/drv/lom.conf /kernel/drv/sparcv9/lom [ verifying class <none> ] /etc/rc0.d/K80tsaldog <linked pathname> /etc/rc2.d/S25tsaldog <linked pathname> /etc/rc2.d/S75lomlited <linked pathname> i.drivers: INFO: Starting ... i.drivers: Adding /cdrom/netra_t_server_lom/Product/SUNWlomr/reloc/ kernel/drv/lom Identified drivers: lom i.drivers: Installing drivers ... Driver: lom ... devlinks ... add_drv(1M) ... i.drivers: Finished [ verifying class <drivers> ]
The LOMlite Utilities package is then installed, followed by copyright and trademark information.
LOMlite Utilities
(sparc.sun4u) 1.1.0,REV=1999.10.20.13.34
Copyright 1999 Sun Microsystems, Inc. All Rights Reserved.
Manufactured in the United States of America.
2550 Garcia Avenue, Mountain View, California, 94043-1100 U.S.A.
Copyright 1999 Sun Microsystems Inc. Tous droits reserves.
Fabrique aux Etats-Unis, 2550 Garcia Avenue, Mountain View, Californie
94043-1100 USA
Using </> as the package base directory.
## Processing package information.
## Processing system information.
16 package pathnames are already properly installed.
## Verifying disk space requirements.
## Checking for conflicts with packages already installed.
## Checking for setuid/setgid programs.
Installing LOMlite Utilities as <SUNWlomu>
## Installing part 1 of 1.
/etc/lomlited.conf
/usr/include/lom_io.h
/usr/include/tsalarm_io.h
/usr/lib/locale/de/LC_MESSAGES/lom.cat
/usr/lib/locale/de/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/es/LC_MESSAGES/lom.cat
/usr/lib/locale/es/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/fr/LC_MESSAGES/lom.cat
/usr/lib/locale/fr/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/it/LC_MESSAGES/lom.cat
/usr/lib/locale/it/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/ko/LC_MESSAGES/lom.cat
/usr/lib/locale/ko/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/sv/LC_MESSAGES/lom.cat
/usr/lib/locale/sv/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/zh/LC_MESSAGES/lom.cat
/usr/lib/locale/zh/LC_MESSAGES/tsalarm.cat
/usr/lib/locale/zh_TW/LC_MESSAGES/lom.cat
/usr/lib/locale/zh_TW/LC_MESSAGES/tsalarm.cat
/usr/sbin/258-7691-15.hex
/usr/sbin/lomctl
/usr/sbin/lominfo
/usr/sbin/lomlited
/usr/sbin/lomprog
/usr/sbin/tsctl
/usr/sbin/tsdog
/usr/sbin/tsmonitor
/usr/sbin/tsstate
/usr/sbin/tsunlock
[ verifying class <none> ]
Installation of <SUNWlomu> was successful.
Step 5 Eject the CD by entering the following commands:
# cd /var/tmp # eject
To install the alarm card software for the Sun Netra t 112x, perform the following steps:
Step 2 Start the installation by typing each of the following commands at a # prompt and pressing Enter:
# cd /cdrom/netrat_11xx_1_0 # pkgadd -d . The following packages are available: 1 SUNWtsalm TS91 Alarm and Monitor Manpages (sparc.sun4u) 1.0,REV=1.1 2 SUNWtsalr TS91 Alarm and Monitor driver (sparc.sun4u) 1.0,REV=1.1 3 SUNWtsalu TS91 Alarm and Monitor Utilities (sparc.sun4u) 1.0,REV=1.1 Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]:
Step 3 Press Enter to install all the packages. The following text appears:
Processing package instance <SUNWtsalm from </cdrom/netrat_11xx_1_0
TS91 Alarm and Monitor Manpages
(sparc.sun4u) 1.0,REV=1.1
Copyright 1997 Sun Microsystems, Inc. All Rights Reserved.
Manufactured in the United States of America.
2550 Garcia Avenue, Mountain View, California, 94043-1100 U.S.A.
Copyright 1997 Sun Microsystems Inc. Tous droits reserves.
Fabrique aux Etats-Unis, 2550 Garcia Avenue, Mountain View, Californie
94043-1100 USA
...
Installing TS91 Alarm and Monitor Manpages as <SUNWtsalm
...
Installation of <SUNWtsalm was successful.
Processing package instance <SUNWtsalr from </cdrom/netrat_11xx_1_0
TS91 Alarm and Monitor driver
(sparc.sun4u) 1.0,REV=1.1
Copyright 1997 Sun Microsystems, Inc. All Rights Reserved.
Manufactured in the United States of America.
2550 Garcia Avenue, Mountain View, California, 94043-1100 U.S.A.
Do you want to continue with the installation of <SUNWtsalr [y,n,?]
Step 4 Type y and press Enter to continue the installation. The following text appears:
Installing TS91 Alarm and Monitor driver as <SUNWtsalr ... Installation of <SUNWtsalr was successful. Processing package instance <SUNWtsalu from </cdrom/netrat_11xx_1_0 TS91 Alarm and Monitor Utilities (sparc.sun4u) 1.0,REV=1.1 Copyright 1997 Sun Microsystems, Inc. All Rights Reserved. Manufactured in the United States of America. 2550 Garcia Avenue, Mountain View, California, 94043-1100 U.S.A. ... Installation of <SUNWtsalu was successful. The following packages are available: 1 SUNWtsalm TS91 Alarm and Monitor Manpages (sparc.sun4u) 1.0,REV=1.1 2 SUNWtsalr TS91 Alarm and Monitor driver (sparc.sun4u) 1.0,REV=1.1 3 SUNWtsalu TS91 Alarm and Monitor Utilities (sparc.sun4u) 1.0,REV=1.1 Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]:
Step 5 Type q to quit the installation.
Step 6 Eject the CD-ROM from the drive by typing each of the following commands at a # prompt and pressing Enter:
# cd / # eject
To install the SAI/P software, perform the following steps:
# cd /cdrom/cdrom0/saip_2.0_u1/Solaris_2.6/Packages # pkgadd -d .
The following screen appears:
The following packages are available:
1 SUNWsaip Serial Asynchronous Interface Driver (PCI)
(sparc) 2.0,REV=1998.10.19
2 SUNWsaipu Serial Asynchronous Interface Utilities (PCI)
(sparc) 2.0,REV=1998.10.19
Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]:
Step 2 Select y and press Enter to install all the packages. The following screen appears:
Processing package instance <SUNWsaip> from </cdrom/sun_saip/saip_2.0_u1/Solaris_7/Packages> Serial Asynchronous Interface Driver (PCI) (sparc) 2.0,REV=1998.10.19 Copyright 1998 Sun Microsystems, Inc. All rights reserved. Using </> as the package base directory. ## Processing package information. ## Processing system information. 9 package pathnames are already properly installed. ## Verifying package dependencies. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. ## Checking for setuid/setgid programs. This package contains scripts which will be executed with super-user permission during the process of installing this package. Do you want to continue with the installation of <SUNWsaip> [y,n,?] y
Step 3 Select y and press Enter to continue. The following screen appears:
Installing Serial Asynchronous Interface Driver (PCI) as <SUNWsaip>
## Installing part 1 of 1.
/etc/init.d/saip
/etc/opt/SUNWconn/bin/saipconfig <symbolic link>
/etc/opt/SUNWconn/bin/saipd <symbolic link>
/etc/opt/SUNWconn/saip/bin/saipconfig
.
.
.
Installation of <SUNWsaipu> was successful.
The following packages are available:
1 SUNWsaip Serial Asynchronous Interface Driver (PCI)
(sparc) 2.0,REV=1998.10.19
2 SUNWsaipu Serial Asynchronous Interface Utilities (PCI)
(sparc) 2.0,REV=1998.10.19
Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]: q
Step 4 To quit this installation process when the installation is finished, type q and press Enter.
Step 5 Enter the following commands to eject the CD-ROM from the drive:
# cd / # eject
Step 6 Reboot the system using the r function.
# reboot -- -r
This completes the installation of the Sun Solaris 2.6 software and patches.
To add an optional second Ethernet interface, continue to the "Configuring a Second Ethernet Interface" section .
If you have a second disk drive to configure, see the "Configuring a Second Disk Drive" section .
If neither of these cases applies to your installation, you can begin installation of the Cisco MGC software by continuing to "Installing the Cisco Media Gateway Controller Software Release 7.4."
If you have questions or need assistance, see the "Obtaining Technical Assistance" section of the Preface.
A second Ethernet interface is optional to the base configuration. You must configure it separately by following the steps below:
Step 2 Save the file and close it.
Step 3 Create a new file named hostname.hme1 in directory /etc. On on the first (and only) line, place the host name for the second Ethernet interface.
Step 4 If the IP address of the second Ethernet interface is on a different network than that of the first Ethernet interface, and this network for the second Ethernet interface has a subnet mask, edit the netmasks file in /etc to add the netmask for the new network. Follow the example in the header of the file.
Step 5 The machine must now be rebooted with a "-r" option to complete the configuration. To do so, type the following command and press Enter:
# reboot -r
Step 6 When the machine finishes rebooting, log in as root.
Step 7 Type the following command and press Enter:
# ifconfig -a
Verify that the new interface, hme1, appears in the output text that looks similar to the following:
![]() |
Note IP addresses are for demonstration purposes only. Actual addresses differ in each application. |
lo0: flags=849<UP,LOOPBACK,RUNNING,MULTICAST> mtu 8232
inet 127.0.0.1 netmask ff000000
hme0: flags=863<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST> mtu 1500
inet 172.24.235.53 netmask ffffff00 broadcast 172.24.235.255
ether 8:0:20:9a:76:6c
hme1: flags=863<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST> mtu 1500
inet 172.24.237.53 netmask ffffff00 broadcast 172.24.237.255
ether 8:0:20:9a:76:6c
This completes the configuration of a second Ethernet interface.
If you have a second disk drive to configure, see the "Configuring a Second Disk Drive" section . Otherwise, you can begin installation of the Cisco MGC software by continuing to "Installing the Cisco Media Gateway Controller Software Release 7.4."
If you have questions or need assistance, see the "Obtaining Technical Assistance" section of the Preface.
If you have a second disk installed that you want to use as mirror of the first in order to increase the availability of the system, go to the "Installing the Volume Manager" section.
If you have a second disk installed that you want to use for log and spool systems in order to increase performance, go to the "Installing Log and Spool File Systems" section .
![]() |
Note If you are installing the operating system software on a single-host system, skip this section. |
This section provides instructions for installing the Sun Enterprise Volume Manager 2.6 software, configuring the hard disk drives, and mirroring the operating system. Disk mirroring increases the availability of your system and prevents data loss. You can offload log and spool tasks to the second disk.
![]() |
Caution This section should be used only for mirroring the boot disk drive onto a second disk instead of using the second drive for the log and spool file systems. |
This section contains the following procedures:
If you use the Sun Enterprise Volume Manager software to mirror your system and you set the system to a future date, you must reinstall the Sun Solaris operating system to reset the current date. If you change the setting from a future date back to the present date without reinstalling Sun Solaris, your system will not operate.
Use the procedure below to install the Sun StorEdge Volume Manager:
Step 2 Log in as root.
Step 3 Install the Volume Manager software patches by entering the following command:
pkgadd -d cdrom/cdrom0/solaris_patches/CSCOh006.pkg
The following text appears:
The following packages are available:
1 CSCOh006 Virtual Switch Controller Volume Manager 2.6 package installation and patches
(sparc) TJB_ELAN_2000_01_04_23_16_GMT
Select package(s) you wish to process (or 'all' to process
all packages). (default: all) [?,??,q]:
Step 4 Press Enter to accept the default response of all. The following text appears:
Processing package instance <CSCOh006> from </var/tmp/CSCOh006.pkg> Virtual Switch Controller Volume Manager 2.6 package installation and patches (sparc) TJB_ELAN_2000_01_04_23_16_GMT Cisco System, Inc. The selected base directory </opt/sun_install> must exist before installation is attempted. Do you want this directory created now [y,n,?,q]
Step 5 Type y and press Enter to create this directory. The following text appears:
Using </opt/sun_install> as the package base directory. ## Processing package information. ## Processing system information. 1 package pathname is already properly installed. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. The following files are already installed on the system and are being used by another package: * /opt/sun_install <attribute change only> * - conflict with a file which does not belong to any package. Do you want to install these conflicting files [y,n,?,q]
Step 6 Type y and press Enter to continue installation. The following text appears:
## Checking for setuid/setgid programs. This package contains scripts which will be executed with super-user permission during the process of installing this package. Do you want to continue with the installation of <CSCOh006> [y,n,?]
Step 7 Type y and press Enter to continue installation. The following text appears:
Installing Virtual Switch Controller Volume Manager 2.6 package installation and patches as <CSCOh006> ## Executing preinstall script. Platform is SUNW,Ultra-80 NOTICE: Architecture checks passed ## Installing part 1 of 1. /opt/sun_install/installVM /opt/sun_install/install_rootdg /opt/sun_install/install_vscdg /opt/sun_install/removeVM /opt/sun_install/remove_rootdg /opt/sun_install/remove_vscdg /var/tmp/106606-02.tar.Z [ verifying class <none> ] ## Executing postinstall script. !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !! !! !! You must now change directories to /opt/sun_install and !! !! run the installVM script as root. !! !! !! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Installation of <CSCOh006> was successful.
Step 8 Enter the following command to run the VM script:
# ./installVM
The CD-ROM is ejected from the machine. The following text appears:
Install the "Sun StorEdge Volume Manager 2.6 Software" CD into the CD-ROM driver Press Enter when ready
Step 9 Reinsert the Sun StorEdge Volume Manager CD into the CD-ROM drive.
Step 10 Press Enter to continue installation. The following text appears:
Sun StorEdge Volume Manager (sparc) 2.6,REV=2.5.3 Copyright 1998 Sun Microsystems, Inc. All rights reserved. Copyright (c) 1990-1997 VERITAS Software Corporation. ALL RIGHTS RESERVED. THIS SOFTWARE IS THE PROPERTY OF AND IS LICENSED BY VERITAS SOFTWARE, AND/OR ITS SUPPLIERS. ## Processing package information.
## Processing system information. 10 package pathnames are already properly installed. ## Verifying package dependencies. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. The following files are already installed on the system and are being used by another package: /etc <attribute change only> Do you want to install these conflicting files [y,n,?,q]
Step 11 Type y and press Enter to continue installation. The following text appears:
## Checking for setuid/setgid programs. The following files are being installed with setuid and/or setgid permissions: /usr/sbin/vxprint <setuid root> Do you want to install these as setuid/setgid files [y,n,?,q]
Step 12 Type y and press Enter to continue installation. The following text appears:
This package contains scripts which will be executed with super-user permission during the process of installing this package. Do you want to continue with the installation of <SUNWvxvm> [y,n,?]
Step 13 Type y and press Enter to continue installation. The following text appears:
Copyright (c) 1990-1997 VERITAS Software Corporation. ALL RIGHTS RESERVED. THIS SOFTWARE IS THE PROPERTY OF AND IS LICENSED BY VERITAS SOFTWARE, AND/OR ITS SUPPLIERS. Using </opt> as the package base directory. ## Processing package information. ## Processing system information. ## Verifying package dependencies. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. ## Checking for setuid/setgid programs. This package contains scripts which will be executed with super-user permission during the process of installing this package.
Do you want to continue with the installation of <SUNWvxva> [y,n,?]
Step 14 Type y and press Enter to continue installation. The following text appears:
Installation of <SUNWvmman> was successful. Ejecting CDROM Changed to /var/tmp directory Uncompressing 106606-02 ... Extracting 106606-02 ... Extraction of patch 106606-02 successful Installing 106606-02 ... Create vxassist file Create vxaltstale file Edit S95vxvm-recover script !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !! The system must be rebooted before running 'vxinstall' !! !! as root to continue the Volume Manager installation. !! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Do you want to reboot now (y/n)?
Step 15 Type y and press Enter to reboot. The following text appears:
REBOOTING # INIT: New run level: 6 The system is coming down. Please wait. System services are now being stopped. Print services stopped. Stopping the syslog service. syslogd: going down on signal 15 Jan 6 12:56:21 snmpdx: received signal 15 The system is down.
This completes installation of the Sun StorEdge Volume Manager software and patch. Continue to the "License Key Entry and Boot Disk Encapsulation" section .
Step 2 Type the following command at the # prompt and press Enter:
# vxinstall
The following notice appears:
VxVM uses license keys to control access. If you have a SPARCstorage Array (SSA) controller or a Sun Enterprise Network Array (SENA) controller attached to your system, then VxVM will grant you a limited use license automatically. The SSA and/or SENA license grants you unrestricted use of disks attached to an SSA or SENA controller, but disallows striping and RAID-5 on non-SSA and non-SENA disks. If you are not running a SPARCstorage Array controller, or a Sun Enterprise Network Array controller, then you must obtain a license key to operate. Licensing information: System host ID: 80c4d518 Host type: SUNW,Ultra-80 SPARCstorage Array or Sun Enterprise Network Array: No arrays found (license is required) Are you prepared to enter a license key [y,n,q,?] (default: y)
Step 3 Press Enter to accept the default answer "yes." The following text appears:
Please enter your key:
Step 4 Type the key number, with spaces, and press Enter. The following text appears:
vrts:vxlicense: INFO: Feature name: CURRSET [95] vrts:vxlicense: INFO: Number of licenses: 1 (non-floating) vrts:vxlicense: INFO: Expiration date: Sun Jun 04 04:00:00 2006 (2340.6 days from now) vrts:vxlicense: INFO: Release Level: 20 vrts:vxlicense: INFO: Machine Class: All vrts:vxlicense: INFO: Key successfully installed in /etc/vx/elm/95. Do you wish to enter another license key [y,n,q,?] (default: n)
Step 5 Press Enter to accept the default answer no. The following text appears:
Volume Manager Installation
Menu: VolumeManager/Install
The Volume Manager names disks on your system using the controller
and disk number of the disk, substituting them into the following
pattern:
c<controller>t<disk>d<disk>
If the Multipathing driver is installed on the system then for the
disk devices with multiple access paths, the controller number
represents a multipath pseudo controller number. For example, if a
disk has 2 paths from controllers c0 and c1, then the Volume Manager
displays only one of them such as c0 to represent both the
controllers.
Some examples would be:
c0t0d0 - first controller, first target, first disk
c1t0d0 - second controller, first target, first disk
c1t1d0 - second controller, second target, first disk
The Volume Manager has detected the following controllers on your system:
c0:
Hit RETURN to continue.
Step 6 Press Enter to continue. The following text appears:
Volume Manager Installation Menu: VolumeManager/Install You will now be asked if you wish to use Quick Installation or Custom Installation. Custom Installation allows you to select how the Volume Manager will handle the installation of each disk attached to your system. Quick Installation examines each disk attached to your system and attempts to create volumes to cover all disk partitions that might be used for file systems or for other similar purposes. If you do not wish to use some disks with the Volume Manager, or if you wish to reinitialize some disks, use the Custom Installation option Otherwise, we suggest that you use the Quick Installation option. Hit RETURN to continue.
Press Enter to continue. The following text appears:
Volume Manager Installation Options Menu: VolumeManager/Install 1 Quick Installation 2 Custom Installation ? Display help about menu ?? Display help about the menuing system q Exit from menus Select an operation to perform:
Step 7 Type 2 and press Enter to continue. The following text appears:
Volume Manager Custom Installation Menu: VolumeManager/Install/Custom The c0t0d0 disk is your Boot Disk. You can not add it as a new disk. If you encapsulate it, you will make your root filesystem and other system areas on the Boot Disk into volumes. This is required if you wish to mirror your root filesystem or system swap area. Encapsulate Boot Disk [y,n,q,?] (default: n)
Step 8 Type y and press Enter to continue. The following text appears:
Enter disk name for c0t0d0 [<name>,q,?] (default: rootdisk)
Step 9 Type rootdiska and press Enter to continue. The following text appears:
The c0t0d0 disk has been configured for encapsulation. Hit RETURN to continue.
Step 10 Press Enter to continue. The following text appears:
Volume Manager Custom Installation Menu: VolumeManager/Install/Custom/c0 Generating list of attached disks on c0.... <excluding root disk c0t0d0 The Volume Manager has detected the following disks on controller c0: c0t1d0 Hit RETURN to continue.
Step 11 Press Enter to continue. The following text appears:
Installation options for controller c0 Menu: VolumeManager/Install/Custom/c0 1 Install all disks as pre-existing disks. (encapsulate) 2 Install all disks as new disks. (discards data on disks!) 3 Install one disk at a time. 4 Leave these disks alone. ? Display help about menu ?? Display help about the menuing system q Exit from menus Select an operation to perform:
Step 12 Type 4 to leave the disks alone and press Enter to continue. The following text appears:
Volume Manager Custom Installation Menu: VolumeManager/Install/Custom The following is a summary of your choices. c0t0d0 Encapsulate Is this correct [y,n,q,?] (default: y)
Step 13 Press Enter to accept the default answer, "yes," and continue.
The system now must be shut down and rebooted in order to continue the reconfiguration. Shutdown and reboot now [y,n,q,?] (default: n)
Step 14 Type y and press Enter to shut down and reboot the system.
Step 15 Wait for the computer to shut down and reboot twice, then proceed to the next section.
This completes license key entry and boot disk encapsulation. Continue to the "Mirroring the Boot Disk" section .
# cd /opt/sun_install # ./install_rootdg
![]() |
Note This process takes approximately 30 minutes to run and does not require user intervention. |
# cd /opt/sun_install # ./install_rootdg The following is displayed. Determine the device names for the disks Platform is SUNW,Ultra-60 A-DSK0: c0t0d0 B-DSK0: c0t1d0 Initialize device c0t1d0 Succeeded Add rootdiskb to rootdg, device is c0t1d0 Succeeded Mirror all the volumes of A-DSK0 to B-DKS0 and make root bootable Mirroring root to rootdiskb Success Mirroring var to rootdiskb Success Mirroring opt to rootdiskb Success Mirroring swap to rootdiskb Success Mirroring usr to rootdiskb Success
Step 2 At the # prompt, type init 6 and press Enter to reboot the system.
# init 6
This completes configuration of a second disk drive to use for disk mirroring.
If you use this second disk drive to hold log file and spool file systems, proceed to the "Installing Log and Spool File Systems" section . Otherwise, you can begin installation of the Cisco MGC software by continuing to "Installing the Cisco Media Gateway Controller Software Release 7.4." If you have questions or need assistance, see the "Obtaining Technical Assistance" section of the Preface.
![]() |
Note Follow the procedures in this section only if you are using a second disk drive for the log and spool file systems, and therefore are not mirroring the second disk drive. |
Use the procedure below to install the log and spool file systems:
Step 2 Type the following command at the # prompt and press Enter:
# pkgadd -d cdrom/cdrom0/solaris_patches/CSCOh005.pkg
The following text appears:
The following packages are available: 1 CSCOh005 Virtual Switch Controller VSC log and spool package (sparc) TJB_ELAN_1999_10_28_20_36_GMT Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]:
Step 3 Press Enter to accept the default answer all. The following text appears:
Processing package instance <CSCOh005 from </var/tmp/CSCOh005.pkg Virtual Switch Controller VSC log and spool package (sparc) TJB_ELAN_1999_10_28_20_36_GMT Cisco System, Inc. Using </opt/sun_install as the package base directory. ## Processing package information. ## Processing system information. 1 package pathname is already properly installed. ## Verifying disk space requirements. ## Checking for conflicts with packages already installed. ## Checking for setuid/setgid programs. This package contains scripts which will be executed with super-user permission during the process of installing this package. Do you want to continue with the installation of <CSCOh005 [y,n,?]
Step 4 Type y and press Enter to continue. The following text appears:
Installing Virtual Switch Controller VSC log and spool package as <CSCOh005> ## Executing preinstall script. Platform is SUNW,Ultra-60 NOTICE: Architecture checks passed ## Installing part 1 of 1. /opt/sun_install/format_log_spool.cmd /opt/sun_install/install_log_spool [ verifying class <none ] ## Executing postinstall script. !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !! !! !! You must now change directories to /opt/sun_install and !! !! run the install_log_spool script as root. !! !! !! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Installation of <CSCOh005> was successful.
Step 5 Change directories to /opt/sun_install, then run the install_log_spool script by typing each of the following commands at the # prompt and pressing Enter:
# cd /opt/sun_install # ./install_log_spool
The following text appears:
Build partition table for c0t1d0 ... Searching for disks...done selecting c0t1d0 ... Adding entries to /etc/vfstab Mounting /opt/CiscoMGC/var/log Mounting /opt/CiscoMGC/var/spool Success!!!
This completes the operating system installation. If you are installing Release 7.3, continue to "Installing the Cisco Telephony Controller Software Release 7.3." If you are installing Release 7.4, continue to "Installing the Cisco Media Gateway Controller Software Release 7.4." If you have questions or need assistance, see the "Obtaining Technical Assistance" section of the Preface.
![]()
![]()
![]()
![]()
![]()
![]()
![]()