This chapter describes the media gateway controller (MGC) billing interface capabilities and its call detail records (CDRs). This chapter is primarily a reference. For an overview of the MGC billing system and how to use it, refer to the Cisco Media Gateway Controller Software Release 7 Operations, Maintenance, and Troubleshooting Guide. For a description of how billing issues affect MGC installation, refer to the Cisco Media Gateway Controller Software Release 7 Installation and Configuration Guide.
This chapter contains the following sections:
The call data block (CDB) gets generated when a call has gone through and has been answered (that is, when the MGC receives the ANM/Answered message.) The call data block (CDB) consists of several call data elements (CDEs), related to a certain point in call (PIC). The format of a CDB is based on tag, length, and value (TLV). Each field within a CDB has a tag, a length, and a value. For more information concerning CDEs and CDBs, refer to the Cisco Media Gateway Controller Software Release 7 Operations, Maintenance, and Troubleshooting Guide. Table 3-1 defines the call deta element fields in any given CDB.
| CDE Tag Numbers | ||||||
|---|---|---|---|---|---|---|
| CDB Name | CDB Tag | Common | Millisecond Granularity | ANSI | ITU | Miscellaneous & Protocol Specific |
Answered | 1010 | 4000-4005, 4008-4016, 4029, 4031, 4034-4039, 4045, 4048 | 4100-4105 | 2000-2007, 2009-2016 | 3000-3003, 3005-3007, 3009-3013 | 6100-6104 |
Deselected | 1020 | 4000-4003, 4006, 4008, 4009, 4015, 4016, 4019, 4020, 4028, 4034-4037 | 4100, 4101, 4106, 4108, 4109 | 2008-2012 | 3008-3012 | 6100-6104 |
Aborted | 1030 | 4000-4004, 4006, 4008-4016, 4019, 4020, 4028, 4029, 4031, 4034-4039, 4045, 4048 | 4100-4103, 4106-4109 | 2000-2009, 2011-2016 | 3000-3003, 3005-3009, 3011, 3013 | 6100-6104 |
Release | 1040 | 4000-4002, 4006, 4019, 4020, 4028, 4030, 4044, 4046, 4047 | 4106-4109 | 2008 | 3008 |
|
Interrupted | 1050 | 4000-4002, 4007 |
|
|
|
|
Ongoing | 1060 | 4000-4002, 4008, 4009, 4015, 4016 |
|
|
|
|
Maintenance | 1070 | 4000-4002, 4017, 4018, 4032, 4033 |
|
|
|
|
External DB | 1080 | 4000-4002, 4040-4043, 4049, 4050 |
|
|
|
|
File Header CDB | 1090 | 4000-4002 |
|
|
| 6000, 6001, 6004 |
File Footer CDB | 1100 | 4000-4002 |
|
|
| 6000, 6001, 6003, 6004 |
End of Call | 1110 | 4000-4002, 4008-4012, 4014-4016, 4028, 4031 | 4100-4109 | 2000, 2001, 2003-2005, 2007, 2008, 2013, 2015 | 3000, 3001, 3003-3005, 3007, 3008 |
|
The call data element (CDE) is the data element (field) that includes a basic information field within a billing record. Examples of CDEs are the calling number, called number, and so on. The call data block consists of several CDEs, related to a certain point in call (PIC). For more inforamation concerning CDEs and CDBs, refer to the Cisco Media Gateway Controller Software Release 7 Operations, Maintenance, and Troubleshooting Guide.
The call data elements are described in CDE description forms. Table 3-2 is a description form that describes description forms.
Name: Name of the call data elements | Tag: its tag value | Source: MGC subsystem that generates the CDE value | |||||||
Description/Purpose: Brief description of the CDE | |||||||||
Format: The format of the CDE value | Length: CDE value length | ||||||||
Data Value: Range of CDE values, or valid values | |||||||||
Extended Data Value: This section includes CDE values that are extended (from the ANSI/ITU standard) by the MGC. | |||||||||
General Information: General information about the CDE and comments. | |||||||||
MGC Release: List the MGC release(s) supporting this CDE. |
| ||||||||
Answered (1010): This row and the next describe if the PIC event is used for this CDE (Yes or No) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y/N | Y/N | Y/N | Y/N | Y/N | Y/N | Y/N | Y/N | Y/N | |
Name: CDB Version | Tag: 4000 | Source: MDL | |||||||
Description/Purpose: Holds CDB version number to control raw CDB layout version. | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 1 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This field is required in every CDB. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Name: CDB Timepoint | Tag: 4001 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for creation of the CDB. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This field is required in every CDB. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Name: Call Reference ID | Tag: 4002 | Source: MDL/Engine | |||||||
Description/Purpose: The Call Reference ID is created by call processing engine as a unique Call ID. Multiple CDBs have this Call Reference ID to associate the CDBs that create the call. The purpose of this field is to uniquely identify a single call. This field is used by downstream systems (such as mediation) to correlate CDBs to create a single CDR record. | |||||||||
Format: BE | Length in Octet: 8 | ||||||||
Data Value: This consists of a 32-bit data/time and a 32-bit ascending sequence number. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This field is required in every CDB. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Name: IAM/Setup Timepoint | Tag: 4003 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of IAM/Setup (or receipt of CRM if a CRM preceded the IAM). | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value | |||||||||
General Information: This message is sent in the forward direction (from the originating exchange to the terminating exchange) to initiate seizure of an outgoing circuit and to transmit number and other information relating to the routing and handling of a call. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: ACM/Alert Timepoint | Tag: 4004 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of ACM/Alert. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value | |||||||||
General Information: This message is sent in the backward direction (from the terminating exchange to the originating exchange), indicating that all signals required for routing the call to the called party have been received. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: ANM/ANSWER Timepoint | Tag: 4005 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of ANM/Answer. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This message is sent in the backward direction (from the terminating exchange to the originating exchange) indicating that the call has been answered. This message can be used in conjunction with the charging information to start measurement of a call duration. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | N | N | N | N | N | N | N | |
Name: REL/RELEASE Timepoint | Tag: 4006 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of First REL/RELEASE. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This message is sent in either direction indicating that the circuit identified in the message is being released due to the reason (cause) supplied and is ready to be put in idle state on receipt of the release complete message. This message provides the release of the circuit of a call initiated by the IAM message. | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | N | |
Name: Crash Timepoint | Tag: 4007 | Source: MDL/Engine | |||||||
Description/Purpose: Last known time point before a crash. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | Y | N | N | N | N | |
Name: Originating Trunk Group | Tag: 4008 | Source: MDL/Engine | |||||||
Description/Purpose: Originating Trunk Group number, which ranges from 1 to 8191. | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: The trunk group number will range from 1 to 8191. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | Y | N | N | Y | |
Name: Originating MEMBER | Tag: 4009 | Source: MDL | |||||||
Description/Purpose: Contains the originating trunk member number within the originating trunk group. There can be up to 2048 members per trunk with a range of 1 to 8191 | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: The originating number ranges from 1 to 8191. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | Y | N | N | Y | |
Name: Calling number | Tag: 4010 | Source: MDL | |||||||
Description/Purpose: These are the numbers of the calling number. | |||||||||
Format: IA5 | Length in Octet: 1 to 96 | ||||||||
Data Value: The digit of the calling number. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: In the SS7/C7 environment, the calling number (Tag 4010) only holds the digit of the calling number, it does not include any NOA, or other information. NOA and other information are presented by its own CDE(s). | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: CHARGED number | Tag: 4011 | Source: MDL | |||||||
Description/Purpose: These are the numbers of the calling number. | |||||||||
Format: IA5 | Length in Octet: 1 to 96 | ||||||||
Data Value: Digit of the calling number. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: DIALED number | Tag: 4012 | Source: MDL | |||||||
Description/Purpose: These are the digits that were dialed by the calling party. | |||||||||
Format: IA5 | Length in Octet: 1 to 96 | ||||||||
Data Value: Digits that were dialed by the calling party. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: LRN number | Tag: 4013 | Source: MDL | |||||||
Description/Purpose: Locations routing number(LRN) used in implementation of local number portability. | |||||||||
Format: IA5 | Length in Octet: 1 to 96 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: CALLED number | Tag: 4014 | Source: MDL | |||||||
Description/Purpose This is the number that the call is sent to. | |||||||||
Format: IA5 | Length in Octet: 1 to 96 | ||||||||
Data Value: Digit for the number that the call is sent to. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: TERMINATING Trunk Group | Tag: 4015 | Source: MDL/Engine | |||||||
Description/Purpose: Terminating Trunk Group number, which ranges from 1 to 8191. | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: The trunk group number will range from 1 to 8191. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | Y | N | N | Y | |
Name: Terminating MEMBER | Tag: 4016 | Source: MDL/Engine | |||||||
Description/Purpose: Contains the terminating trunk member number within the originating trunk group. There can be up to 2048 members per turnk with a range of 1 to 8191 | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: The terminating number will range from 1 to 8191. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | Y | N | N | Y | |
Name: MAINTENANCE Trunk Group | Tag: 4017 | Source: MDL/Engine | |||||||
Description/Purpose: Maintenance Trunk Group number involved for maintenance, which ranges from 1 to 8191. | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: The trunk group number will range from 1 to 8191. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | Y | N | N | |
Name: MAINTENANCE Circuit Member | Tag: 4018 | Source: MDL/Engine | |||||||
Description/Purpose: Maintenance Circuit Member number involved for maintenance that ranges from 1 to 8191. | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: The circuit member number will range from 1 to 8191. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | Y | N | N | |
Name: GLARE ENCOUNTERED | Tag: 4019 | Source: MDL | |||||||
Description/Purpose: Call completed but glare was encountered during the call. | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 0 = No Glare 1 = Glare | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | N | |
Name: RLC/RELEASE Complete | Tag: 4020 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of RLC/RELEASE complete. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | N | |
Name: First Release Source | Tag: 4028 | Source: MDL | |||||||
Description/Purpose: Indicates if the release source was from originating, terminating, or local (MGC). | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 0 = Originating side 1 = Terminating side 2 = Local (MGC) | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | Y | |
Name: LNP Dip | Tag: 4029 | Source: MDL | |||||||
Description/Purpose: Indicates whether an LNP dip was performed. | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 0 = Not required 1 = Required and succeeded 2 = Not required, previous switch accomplished LNP 3 = Required, failed | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Total Meter Pulses | Tag: 4030 | Source: MDL | |||||||
Description/Purpose: Holds the total meter pulses. Certain ISUPs and TUPs support this optional information. | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | Y | N | N | N | N | N | |
Name: MGC Info Field | Tag: 4031 | Source: MDL/Engine | |||||||
Description/Purpose: Aggregation of MGC-specific information. This field provides backward compatibility for MGC releases earlier than Release 5.0. | |||||||||
Format: BE | Length in Octet: 19 | ||||||||
Data Value:
| |||||||||
Extended Data Value: The MGC info field consists of several sub-fields, the sub-fields are stored within the value section of the MGC info field without any Tags and values. The MGC Info fields provide the customer with backward compatibility. For a description of the MGC info field, refer to "The MGC Info Field.". | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Maintenance Type | Tag: 4032 | Source: MDL | |||||||
Description/Purpose: Indicates the type of maintenance requested. | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 1 = Block 2 = Unblock 3 = Reset | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | Y | N | N | |
Name: Maintenance Reason | Tag: 4033 | Source: MDL | |||||||
Description/Purpose: Indicates the reason that the maintenance was requested. | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 1 = Remote 2 = Local | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | Y | N | N | |
Name: Ingress Originating Point Code | Tag: 4034 | Source: MDL | |||||||
Description/Purpose: Ingress originating point code. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: For ANSI SS7 1-3 Network 4-6 Cluster 7-9 Member For ITU C7 1-3 4-6 7-9 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Ingress destination Point Code | Tag: 4035 | Source: MDL | |||||||
Description/Purpose: Ingress destination point code. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: For ANSI SS7 1-3 Network 4-6 Cluster 7-9 Member For ITU C7 1-3 4-6 7-9 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Egress Originating Point Code | Tag: 4036 | Source: MDL | |||||||
Description/Purpose: Egress originating point code. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: For ANSI SS7 1-3 Network 4-6 Cluster 7-9 Member For ITU C7 1-3 4-6 7-9 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Egress Destination Point Code | Tag: 4037 | Source: MDL | |||||||
Description/Purpose: Egress destination point code. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: For ANSI SS7 1-3 Network 4-6 Cluster 7-9 Member For ITU C7 1-3 4-6 7-9 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Ingress Media Gateway ID | Tag: 4038 | Source: MDL | |||||||
Description/Purpose: Ingress media gateway ID (expressed in address). | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Egress Media Gateway ID | Tag: 4039 | Source: MDL | |||||||
Description/Purpose: Egress media gateway ID (expressed in address). | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: TCAP Transaction ID | Tag: 4040 | Source: MDL | |||||||
Description/Purpose: It holds a unique identification number for each external request to a SCP, an intelligent peripheral(IP), or some other database. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | N | Y | N | |
Name: Transaction Start Time | Tag: 4041 | Source: MDL/Engine | |||||||
Description/Purpose: Time that the MGC sent an external request to an SCP, intelligent peripheral, or other database. | |||||||||
Format: DT2 | Length in Octet: 6 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | N | Y | N | |
Name: Transaction End Time | Tag: 4042 | Source: MDL/Engine | |||||||
Description/Purpose: Time that the MGC received a response from an external request to an SCP, intelligent peripheral, or other database. | |||||||||
Format: DT2 | Length in Octet: 6 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | N | Y | N | |
Name: TCAP Database ID | Tag: 4043 | Source: MDL/Engine | |||||||
Description/Purpose: SCP, intelligent peripheral (IP), or some other external database identification number for which a transaction was performed. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | N | Y | N | |
Name: Announcement ID | Tag: 4044 | Source: MDL | |||||||
Description/Purpose: Announcement ID value. | |||||||||
Format: BE | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | Y | N | N | N | N | N | |
Name: Route Selection Info | Tag: 4045 | Source: MDL | |||||||
Description/Purpose: Route index and the route ID. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Sub-field Length Value Route Index 2 Route Index that is used to select a route Route ID 2 Route ID selected | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Ingress Packet Info | Tag: 4046 | Source: MDL/Engine | |||||||
Description/Purpose: Packets sent, packet received, packets lost, octets sent, octets received, Jitter, latency information (reserved 1, & 2) from the ingress gateway. | |||||||||
Format: BE | Length in Octet: 56 | ||||||||
Data Value: Please see table below. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | Y | N | N | N | N | N | |
| Sub-field name | Encoding | Length | Position | Description |
|---|---|---|---|---|
Packets sent | BE | 8 | 1 | MGCP->DLCX or DLCX ack,P:PS= |
Packets recv | BE | 8 | 9 | MGCP->DLCX or DLCX ack,P:PR= |
Packets Lost | BE | 8 | 17 | MGCP->DLCX or DLCX ack,P:PL= |
Octet Sent | BE | 8 | 25 | MGCP->DLCX or DLCX ack,P:OS= |
Octet Recv | BE | 8 | 33 | MGCP->DLCX or DLCX ack,P:OR= |
Jitter | BE | 4 | 41 | MGCP->DLCX or DLCX ack,P:JI= |
Latency | BE | 4 | 45 | MGCP->DLCX or DLCX ack,P:LA= |
Reservd1 | BE | 4 | 49 |
|
Reserved2 | BE | 4 | 53 |
|
Name: Egress Packet Info | Tag: 4047 | Source: MDL/Engine | |||||||
Description/Purpose: Packets sent, packet received, packets lost, octets sent, octets received, Jitter, latency information (reserved1, & 2) from the egress gateway. | |||||||||
Format: BE | Length in Octet: 56 | ||||||||
Data Value: Please see table below. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | Y | N | N | N | N | N | |
| Sub-field name | Encoding | Length | Position | Description |
|---|---|---|---|---|
Packets sent | BE | 8 | 1 | MGCP->DLCX or DLCX ack,P:PS= |
Packets recv | BE | 8 | 9 | MGCP->DLCX or DLCX ack,P:PR= |
Packets Lost | BE | 8 | 17 | MGCP->DLCX or DLCX ack,P:PL= |
Octet Sent | BE | 8 | 25 | MGCP->DLCX or DLCX ack,P:OS= |
Octet Recv | BE | 8 | 33 | MGCP->DLCX or DLCX ack,P:OR= |
Jitter | BE | 4 | 41 | MGCP->DLCX or DLCX ack,P:JI= |
Latency | BE | 4 | 45 | MGCP->DLCX or DLCX ack,P:LA= |
Reservd1 | BE | 4 | 49 |
|
Reserved2 | BE | 4 | 53 |
|
Name: Directional Flag | Tag: 4048 | Source: MDL/Engine | |||||||
Description/Purpose: | |||||||||
Format: BE | Length in Octet: 1 | ||||||||
Data Value: 0 = Intermediate Switch (E-ISUP to E-ISUP) 1= Ingress Switch (^E-ISUP to E-ISUP) 2 = Egress Switch (E-ISUP to ^E-ISUP) 3= Both (E-ISUP to ^E-ISUP) | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Service Logic ID | Tag: 4049 | Source: MDL | |||||||
Description/Purpose: This field is used in AIN environment. It records an identification of service logic in the SCP that was used. The AMAslpID returns from the SCP will hold the service logic ID. | |||||||||
Format: IA5 | Length in Octet: 9 | ||||||||
Data Value: 000000001-899999999 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This field implies that the mediation software (when configured to generate AMA) generates Structure Code 220. (For more details please refer to BellCore GR-2892-CORE section 8.) | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | N | Y | N | |
Name: AMA Line Number | Tag: 4050 | Source: MDL | |||||||
Description/Purpose: This field is used in AIN environment. It is included in Analyzed_Route message. It uses AINDigits format and contains the original called party ID, incoming terminating number, or ANI. | |||||||||
Format: IA5 | Length in Octet: 15 | ||||||||
Data Value: Up to a 12 digit line number and 3-digit line number type. | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: This field implies that the mediation software (when configured to generate AMA) generates Structure Code 220 with AMALineNumber to be recorded in Module Code 307. (For more details please refer to BellCore GR-2892-CORE section 8.) NOTE: the Analyzed_Route message allows up to two AMALineNumber parameters; therefore, the MGC can save up to two AMA line numbers and the mediation can generate two module Code 307s. | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | N | N | N | N | N | Y | N | |
Name: IAM Timepoint Received_ms | Tag: 4100 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when IAM received in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y\Q | N | N | N | N | N | Y | |
Name: IAM Timepoint Sent_ms | Tag: 4101 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when IAM sent in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | Y | |
Name: ACM Timepoint Received_ms | Tag: 4102 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when ACM received in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: ACM Timepoint Sent_ms | Tag: 4103 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when ACM sent in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: ANM Timepoint Received_ms | Tag: 4104 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when ANM received in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | N | N | N | N | N | N | Y | |
Name: ANM Timepoint Sent_ms | Tag: 4105 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when ACM sent in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | N | N | N | N | N | N | Y | |
Name: First REL Timepoint_ms | Tag: 4106 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of first REL/RELEASE | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | Y | |
Name: Second REL Timepoint_ms | Tag: 4107 | Source: MDL/Engine | |||||||
Description/Purpose: Time point for receipt of second REL/RELEASE | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | N | Y | Y | N | N | N | N | Y | |
Name: RLC Timepoint Received_ms | Tag: 4108 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when RLC received in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | Y | |
Name: RLC Timepoint Sent_ms | Tag: 4109 | Source: MDL/Engine | |||||||
Description/Purpose: Record timepoint when RLC sent in milliseconds since 1970 | |||||||||
Format: Binary | Length in Octet: 6 | ||||||||
Data Value: Cisco TAC Time plus 2 bytes for milliseconds
| |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | Y | |
Name: Calling party Category | Tag: 2000 | Source: MDL | |||||||
Description/Purpose: Indicates what type of calling party is placing the call. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: The following codes are used in the CPC parameter field: 00000000 Calling Party's category unknown (Default) * 00000001 operator, language French 00000010 operator, language English 00000011 operator, language German 00000100 operator, language Russian 00000101 operator, language Spanish 00000110 | 00000111 |-> Available to admin. For selecting a particular lang. 00001000 | 00001001 reserved 00001010 Ordinary calling subscriber * 00001011 Ordinary calling subscriber with priority 00001100 Data Call 00000001 operator, language French 00001101 Test Call * 00001110 Spare 00001111 Payphone 00010000 to CCITT spare 11011111 11100000 Emergency service call 11100001 High priority Emergency service call 11100010 National security and emergency 11100011 to ANSI spare 11110111 11110000 to Network specific use 11111110 11111111 Reserved | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: User Service Information | Tag: 2001 | Source: MDL | |||||||
Description/Purpose: The purpose of this parameter is to send the data transmission parameters to the distant exchange. The field format is the same as the bearer capability information element from ANSI standerd T1.607. | |||||||||
Format: ANSI T1.113 | Length in Octet: 2 to 13 | ||||||||
Data Value: For more detail, please refer to ANSI T1.113. Extension: octet continues through the next octet, 1 last octet Coding standard: the setting should be 00 for "CCITT standard, 10 for national Information Transfer Capability. For POTS calling, this field will be set at either one of the following: 00000 speech" 01000 unrestricted digital information 01001 Restricted digital information 10000 3.1 kHz audio 10001 unrestricted digital information with tone & announcements Transfer Mode (octet 2) 00 Circuit Mode 10 Packet Mode 7.3 Information Transfer Rate 00000 packet mode only 10000 64 Kb 00011 384 Kb 10100 1472 Kb 10101 1536 Kb 10111 1920 Kb 11000 Multi-rate Structure, Configuration, Establishment,etc: please refer to T1.113 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Originating Line Information | Tag: 2002 | Source: MDL | |||||||
Description/Purpose: Indicates to the MGC what II digits are being sent from the LEC. This differentiate calls based on the II digits | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 00000000 to Binary equivalent of the II digits 01100011
01100100 to Reserved 11111111 | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Calling Number Nature of Address | Tag: 2003 | Source: MDL | |||||||
Description/Purpose: Tells the MGC how the number was delivered. This field tells what type of address the calling party is. In POTS calling, there are usually 2 values that will be used. They are Unique national number and Non-unique national number. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 0000000 Unknown - If the LEC doesn't know what type of line the calling party is, it will send this value to the MGC. The MGC will not alter this value and will not do anything as far as billing with this field. 0000001 Unique subscriber number 0000010 Spare - (National use) 0000011 Unique National Number 0000100 Unique International Number 0000101 to Spare 1110000 1110001 Non-unique subscriber number 1110010 Spare 1110011 Non-unique national 111010 0 Non-unique International 1110101 Spare 1110110 Spare 1110111 Test line 1111000 to Reserved 1111000 1111111 Spare | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Charged Number Nature of Address | Tag: 2004 | Source: MDL | |||||||
Description/Purpose: Indicates to the MGC how the number was delivered. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 0000000 Unknown - If the LEC doesn't know what type of line the calling party is, it will send this value to the MGC. The MGC will not alter this value and will not do anything as far as billing with this field. 0000001 Unique subscriber number 0000010 Spare - (National use) 0000011 Unique National Number 0000100 Unique International Number 0000101 to Spare 1110000 1110001 Non-unique subscriber number 1110010 Spare 1110011 Non-unique national 111010 0 Non-unique International 1110101 Spare 1110110 Spare 1110111 Test line 1111000 to Reserved 1111000 1111111 Spare | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Dialed Number Nature of Address | Tag: 2005 | Source: MDL | |||||||
Description/Purpose: Allows the Call Process to route a call differently based on the nature of address value provided in the IAM called number parameter. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 0000000 Unknown - If the LEC doesn't know what type of line the calling party is, it will send this value to the MGC. The MGC will not alter this value and will not do anything as far as billing with this field. 0000001 Unique subscriber number 0000010 Spare - (National use) 0000011 Unique National Number 0000100 Unique International Number 0000101 to Spare 1110000 1110001 Non-unique subscriber number 1110010 Spare 1110011 Non-unique national 111010 0 Non-unique International 1110101 Spare 1110110 Spare 1110111 Test line 1111000 to Reserved 1111000 1111111 Spare | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: LRN Nature of Address | Tag: 2006 | Source: MDL | |||||||
Description/Purpose: . | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 0000000 Unknown - If the LEC doesn't know what type of line the calling party is, it will send this value to the MGC. The MGC will not alter this value and will not do anything as far as billing with this field. 0000001 Unique subscriber number 0000010 Spare - (National use) 0000011 Unique National Number 0000100 Unique International Number 0000101 to Spare 1110000 1110001 Non-unique subscriber number 1110010 Spare 1110011 Non-unique national 111010 0 Non-unique International 1110101 Spare 1110110 Spare 1110111 Test line 1111000 to Reserved 1111000 1111111 Spare | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Called Number Nature of Address | Tag: 2007 | Source: MDL | |||||||
Description/Purpose: . | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 0000000 Unknown - If the LEC doesn't know what type of line the calling party is, it will send this value to the MGC. The MGC will not alter this value and will not do anything as far as billing with this field. 0000001 Unique subscriber number 0000010 Spare - (National use) 0000011 Unique National Number 0000100 Unique International Number 0000101 to Spare 1110000 1110001 Non-unique subscriber number 1110010 Spare 1110011 Non-unique national 111010 0 Non-unique International 1110101 Spare 1110110 Spare 1110111 Test line 1111000 to Reserved 1111000 1111111 Spare | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Reason Code | Tag: 2008 | Source: MDL | |||||||
Description/Purpose: Incorporates SS7 release with cause values and any additional reasons that the basic call model determines. | |||||||||
Format: ANSI T1.113 | Length in Octet: 2 | ||||||||
Data Value: The value of this field includes the first two Octets of the cause Indicators. Please refer to ANSI T1.113 specification. (No diagnostic information included) | |||||||||
Extended Data Value: NOTE: Tag 2008 extends ANSI definition by adding COT failure indicators according to the following ANSI rules, with slight modification as the following: Octet 1: Extension 0 Coding Standard 11 Spare 0 Location 0011 Octet 2: Extension 1 Cause 1111110 | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | Y | |
Name: Forward Call Indicators Received | Tag: 2009 | Source: MDL | |||||||
Description/Purpose: Parameter includes: International Call Ind.; End To End Method Ind.; Interworking Ind.; IAM Segmentation Ind.; ISDN User Part Ind.; ISDN User Part Preference Ind.; ISDN Access Ind.; SCCP Method Ind. | |||||||||
Format: ANSI T1.113 | Length in Octet: 2 | ||||||||
Data Value: National/International call indicator Bit A For Pots calling, the bit A should be coded as a 0. this signifies that this is an incoming national call. If the call is coded 1, this will signify that the call is an incoming international call.
End-to-end method indicator Bits CB 00 no end to end method available 01 Pass along method available 10 SCCP method available 11 both Pass along and SCCP methods available. Interworking indicator Bit D This field will tell the MGC if there has been any Interworking encountered as far as the type of signaling for this call. No pertinent information will need to be acted upon by the MGC, it should just pass the information to the destination. "0" means no interworking encountered (SS7 al the way. "1" means interworking encountered
IAM Segmentation indicator BIT E: In POTs calling, this segmentation indicator will be marked with a 0.
ISDN User Part indicator BIT F, HG, I: This is a more granular field for the usage of the ISDN User Part. In the US, the ISDN User part is used exclusively. For POTs national numbers, this field will be marked 1 for ISDN User part used all the way. That is, if the Interworking indicator is set at 0 (no interworking). If the incoming call has a 0 in this field, it means that there was interworking or the incoming international call could have used TUP for signaling before reaching the national Network. The MGC should not have to deal with this bit, it should pass it on to the destination. For more details please refer to ANSI T1.113 specification | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Forward Call Indicators Sent | Tag: 2010 | Source: MDL | |||||||
Description/Purpose: Parameter includes: International Call Ind.; End To End Method Ind.; Interworking Ind.; IAM Segmentation Ind.; ISDN User Part Ind.; ISDN User Part Preference Ind.; ISDN Access Ind.; SCCP Method Ind. | |||||||||
Format: ANSI T1.113 | Length in Octet: 2 | ||||||||
Data Value: National/International call indicator Bit A For Pots calling, the bit A should be coded as a 0. this signifies that this is an incoming national call. If the call is coded 1, this will signify that the call is an incoming international call.
End-to-end method indicator Bits CB 00 no end to end method available 01 Pass along method available 10 SCCP method available 11 both Pass along and SCCP methods available. Interworking indicator Bit D This field will tell the MGC if there has been any Interworking encountered as far as the type of signaling for this call. No pertinent information will need to be acted upon by the MGC, it should just pass the information to the destination. "0" means no interworking encountered (SS7 al the way. "1" means interworking encountered
IAM Segmentation indicator BIT E: In POTs calling, this segmentation indicator will be marked with a 0.
ISDN User Part indicator BIT F, HG, I: This is a more granular field for the usage of the ISDN User Part. In the US, the ISDN User part is used exclusively. For POTs national numbers, this field will be marked 1 for ISDN User part used all the way. That is, if the Interworking indicator is set at 0 (no interworking). If the incoming call has a 0 in this field, it means that there was interworking or the incoming international call could have used TUP for signaling before reaching the national Network. The MGC should not have to deal with this bit, it should pass it on to the destination. For more details please refer to ANSI T1.113 specification | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | N | N | N | N | N | N | N | |
Name: Nature of Connection Indicators Received | Tag: 2011 | Source: MDL | |||||||
Description/Purpose: This is used to record the Nature of Connection received from the IAM. There are three possible indicators that can be received. They are the satellite indicator, the continuity check indicator, and the echo suppressor indicator. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: Satellite Indicator - This field provides the MGC with information on how many satellites have been used on this circuit. If the field is set to 00 and the MGC will send the circuit out on a circuit going over a satellite, the field will be incremented by one. The same goes for the other incoming settings for example, 01 goes to 10, 10 goes to 11. If the outgoing circuit doesn't go over a satellite, the field will not be incremented.. Continuity check indicator -The MGC will have to act upon this field base on what is received. Also depending on mutual agreements with the LECs, each outgoing trunk group will have to be able to send Continuity tones to the terminating LECs with a frequency between 0% to 100% of the time. This has to be settable on a per trunk group basis. Also The MGC will have the capability to interpret the incoming continuity field and tell the Coding Unit what needs to be done. Echo suppressor indicator - (Bit E) If this field is filled, the outgoing half echo control is already set on previous circuits, there is no need for the terminating MGC to engage the EC. for this call. If the MGC does activate the echo canceller, this field needs to be set for the outgoing IAM message to subsequent switches. | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Nature of Connection Indicators Sent | Tag: 2012 | Source: MDL | |||||||
Description/Purpose: This is used to record the Nature of Connection sent. There are three possible indicators that can be sent. They are the satellite indicator, the continuity check indicator, and the echo suppressor indicator. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: Satellite Indicator - This field provides the MGC with information on how many satellites have been used on this circuit. If the field is set to 00 and the MGC will send the circuit out on a circuit going over a satellite, the field will be incremented by one. The same goes for the other incoming settings for example, 01 goes to 10, 10 goes to 11. If the outgoing circuit doesn't go over a satellite, the field will not be incremented.. Continuity check indicator -The MGC will have to act upon this field base on what is received. Also depending on mutual agreements with the LECs, each outgoing trunk group will have to be able to send Continuity tones to the terminating LECs with a frequency between 0% to 100% of the time. This has to be settable on a per trunk group basis. Also The MGC will have the capability to interpret the incoming continuity field and tell the Coding Unit what needs to be done. Echo suppressor indicator - (Bit E) If this field is filled, the outgoing half echo control is already set on previous circuits, there is no need for the terminating MGC to engage the EC. for this call. If the MGC does activate the echo canceller, this field needs to be set for the outgoing IAM message to subsequent switches. | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Transit network Selection | Tag: 2013 | Source: MDL | |||||||
Description/Purpose: Includes Type of Network; Network Identification Plan; Digits; Circuit Code. | |||||||||
Format: ANSI T1.113 | Length in Octet: 3 or 4 | ||||||||
Data Value: Network Identification Plan: The Network ID plan field will tell the MGC what type of ID the parameter will have. Since POTS calling is using the National Network Plan, there will be 2 values that will pertain to the MGC. They are 3 digit CAC and 4 digit CAC.
National Network ID:
0000 Unknown 0001 3 Digit Carrier Identification Code - If this value is used, the layout of the parameter will be the 1st figure described above. 0010 4 Digit Carrier Identification Code - If this value is used, the layout of the parameter will be the 2nd figure described above. 0011 to Spare 0111 1000 to Reserved for Network Specific Use. 1111 Type of Network Identification: This field will hold the type of network identification for the transit network parameter. 000 CCITT 010 National Netowrk ID
Spare bit Digits 1,2,3 or Digits 1,2,3,4 These fields will hold the Carrier Identification Code of the International Transit Carrier that is required.
Circuit Code The circuit code field will tell the carrier how the call was dialed. The following values will be found in this field: 0000 Unknown 0001 International Call, no operator 0010 International Call, operator requested | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Carrier Identification Parameter | Tag: 2014 | Source: MDL | |||||||
Description/Purpose: Parameter includes Network Identification Plan; Type of Network Identification; Spare; Digit 1; Digit 2; Digit 3; Digit 4 or Null. | |||||||||
Format: ANSI T1.113 | Length in Octet: 3 or 4 | ||||||||
Data Value: Network Identification Plan This field will tell the MGC what type of Carrier Identification the caller is requesting. The MGC will look at this field to determine if the requested CIC is a 3 digit or 4 digit code. It will tell the MGC how many digits to expect in the Digits field.
Type of Network Identification This field gives the identification of the network numbering plan. For POTS calls from the LECs, the value of this field will be 010 (National Network ID. Spare Not Applicable Digit 1-3 or 1-4 Requested Carrier Identification Code. | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Carrier Selection Parameter | Tag: 2015 | Source: MDL | |||||||
Description/Purpose: This will tell the MGC how the caller dialed. It may be used to determine how the call will be routed. This parameter will tell the MGC how the Carrier Access Code was dialed. With this information and the above Carrier Identification parameter, the MGC will be able to route the call in a more granular fashion. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: 00000000 no indication 00000001 Selected Carrier identification code presubscribed and not input by calling party 00000010 Selected carrier identification code presubscribed and input by calling party 00000011 Selected carrier identification code presubscribed, no indication of whether input by calling party. 00000100 Selected carrier identification code not presubscribed and input by calling party 00000101 to Spare 11111110 11111111 Reserved | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Jurisdiction Information Parameter | Tag: 2016 | Source: MDL | |||||||
Description/Purpose: The parameter provides numerical data indicating the geographic origination of the call. | |||||||||
Format: IA5 | Length in Octet: 6 | ||||||||
Data Value: | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Calling Party Category | Tag: 3000 | Source: MDL | |||||||
Description/Purpose: Indicates what type of calling party is placing the call | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 5.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: User Service Information | Tag: 3001 | Source: MDL | |||||||
Description/Purpose: | |||||||||
Format: ANSI T1.113 | Length in Octet: 2 to 13 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Originating Line Information | Tag: 3002 | Source: MDL | |||||||
Description/Purpose: This field will tell the MGC what II digits are being sent from the LEC. This will differentiate different calls based on the II digits | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Calling Number Nature of Address | Tag: 3003 | Source: MDL | |||||||
Description/Purpose: This tells the MGC how the number was delivered. This field tells what type of address the calling party is. In POTS calling, there are usually 2 values that will be used. They are Unique national number and Non unique national number. | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Dialed Number Nature of Address | Tag: 3005 | Source: MDL | |||||||
Description/Purpose: This value allows the Call Process to route a call differently based on the Nature of Address value provided in the IAM Called Number parameter. | |||||||||
Format: ANSI T1.113 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: LRN Nature of Address | Tag: 3006 | Source: MDL | |||||||
Description/Purpose: . | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: LRN Nature of Address | Tag: 3006 | Source: MDL | |||||||
Description/Purpose: . | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: Called Number Nature of Address | Tag: 3007 | Source: MDL | |||||||
Description/Purpose: . | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | Y | |
Name: Reason Code | Tag: 3008 | Source: MDL | |||||||
Description/Purpose: Incorporates C7 release with cause values and any additional reasons that the basic call model determines. | |||||||||
Format: ITU-T Q.763 | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: NOTE: Tag 3008 extends ANSI definition by adding COT failure indicators according to the following ANSI rules, with slight modification as the following: Octet 1: Extension 0 Coding Standard 11 Spare 0 Location 0011 Octet 2: Extension 1 Cause 1111110 | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N | Y | Y | Y | N | N | N | N | Y | |
Name: Forward Call Indicators Received | Tag: 3009 | Source: MDL | |||||||
Description/Purpose: Parameter includes: International Call Ind.; End To End Method Ind.; Interworking Ind.; IAM Segmentation Ind.; ISDN User Part Ind.; ISDN User Part Preference Ind.; ISDN Access Ind.; SCCP Method Ind. | |||||||||
Format: ITU-T Q.763 | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Forward Call Indicators Sent | Tag: 3010 | Source: MDL | |||||||
Description/Purpose: Parameter includes: International Call Ind.; End To End Method Ind.; Interworking Ind.; IAM Segmentation Ind.; ISDN User Part Ind.; ISDN User Part Preference Ind.; ISDN Access Ind.; SCCP Method Ind. | |||||||||
Format: ITU_T Q.763 | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | N | N | N | N | N | N | N | |
Name: Nature of Connection Indicators Received | Tag: 3011 | Source: MDL | |||||||
Description/Purpose: This is used to record the Nature of Connection received from the IAM. There are three possible indicators that can be received. They are the satellite indicator, the continuity check indicator, and the echo suppressor indicator. | |||||||||
Format: ITU-T Q.763 | Length in Octet: 2 | ||||||||
Data Value:
| |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | Y | N | N | N | N | N | N | |
Name: Nature of Connection Indicators Sent | Tag: 3012 | Source: MDL | |||||||
Description/Purpose: This is used to record the Nature of Connection sent. There are three possible indicators that can be sent. They are the satellite indicator, the continuity check indicator, and the echo suppressor indicator. | |||||||||
Format: ITU-T Q.763 | Length in Octet: 2 | ||||||||
Data Value: | |||||||||
Extended Data Value: | |||||||||
General Information: | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | Y | N | N | N | N | N | N | N | |
Name: Transit Network Selection | Tag: 3013 | Source: MDL | |||||||
Description/Purpose: This is used to identify each previous network type transited | |||||||||
Format: ITU-T Q.763 | Length in Octet: 1-n | ||||||||
Data Value: | |||||||||
Extended Data Value: | |||||||||
General Information: Only used with the following ITU ISUPs: HONG_KONG, AUSTRALIAN, FRENCH, NTT, JAPAN. Can also be used for national ISUPs, within any particular country, with private designations for their network type | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
Y | N | Y | N | N | N | N | N | N | |
Name: MGC ID | Tag: 6000 | Source: CDR Dumper | |||||||
Description/Purpose: MGC ID on which the CDR file was created. | |||||||||
Format: IA5 | Length in Octet: 1-n | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: Note that this field used (only) by the CDR dumper to generate the file header CDB record and the file footer CDB record | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | |
Name: File Start Time | Tag: 6001 | Source: CDR Dumper | |||||||
Description/Purpose: Start time of an CDR file timespan. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: Note that this field generated by the CDR dumper to generate the file header CDB record. | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | |
Name: File End Time | Tag: 6002 | Source: CDR Dumper | |||||||
Description/Purpose: End time of an CDR file timespan. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: Note that this field generated by the CDR dumper to generate the file footer CDB record | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | |
Name: Total Number of CDB records | Tag: 6003 | Source: CDR Dumper | |||||||
Description/Purpose: Identify total number of CDB records included in the CDR file. | |||||||||
Format: BE | Length in Octet: 4 | ||||||||
Data Value: Time in Cisco TAC format (number of seconds since January 1, 1970). | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: Note that this field generated by the CDR dumper to generate the file footer CDB record | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | |
Name: MGC version | Tag: 6004 | Source: CDR Dumper | |||||||
Description/Purpose: Identify the MGC software version. | |||||||||
Format: ASCII | Length in Octet: 10 | ||||||||
Data Value: | |||||||||
Extended Data Value: No extended value. | |||||||||
General Information: Note that this field used (only) by the CDR dumper to generate the file header CDB record and the file footer CDB record | |||||||||
MGC Release: Release 7.0 and later. |
| ||||||||
Answered (1010) | Deselected (1020) | Aborted (1030) | Release (1040) | Interrupted (1050) | Ongoing (1060) | Maintenance (1070) | External DB (1080) | End of Call (1110) | |
N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Jun 6 07:46:33 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.