| Obtain Tools and Equipment |
To place an order, contact Cisco Customer Service (408 526 4000 or 800 553 6387).
| Install Chassis and Connect Cables |



![]() | Warning See the Cisco MC3810 Series Multiservice Access Concentrators Hardware Installation Guide for safety information you need to know before working on the Cisco MC3810. |
![]() | Caution If you place the Cisco MC3810 on a desktop, do not place anything that weighs more than 10 pounds (4.5 kilograms) on top of the chassis. |
![]() | Caution Do not remove the rubber feet. They provide a space for air circulation. |
Step 1 Choose one of the methods shown in the above figure, and attach the mounting brackets as shown.
Step 2 Install the chassis in the rack.
| Install Chassis and Connect Cables (continued) |

Step 1 Install the smaller brackets as shown in the figure above.
Step 2 Attach the chassis to the wall.
![]() | Caution Do not remove the rubber feet. They provide a space for air circulation. |
| Install Chassis and Connect Cables (continued) |
Hold the connectors side-by-side, with the tab at the back. The colored wires are in the opposite sequence at opposite ends of the cable. If your cable came from Cisco Systems, pin 1 is white on one plug, and pin 8 is white on the opposite plug. (A rollover cable reverses the wire connections at the opposite ends:
1 to 8, 2 to 7, 3 to 6, 4 to 5, 5 to 4, 6 to 3, 7 to 2, and 8 to 1.)
Hold the connectors side-by-side, with the tab at the back. The colored wires are in the same sequence at opposite ends of the cable. (A straight-through cable connects like-numbered pins at opposite ends: 1 to 1, 2 to 2, 3 to 3, 4 to 4, 5 to 5, 6 to 6, 7 to 7, and 8 to 8.)
View the connector for the Cisco MC3810 port, with the tab at the back. There are wires attached to four of the pins: 1, 2, 4, and 5. (The pinout at the opposite end depends on the interface at that end.)



| Install Chassis and Connect Cables (continued) |

If you are using a T1/E1 network interface, connect the T1/E1 trunk port to a network demarcation device.
If the trunk port has an RJ-48 jack, use an RJ-48 straight-through cable (not included), or a special cable if required for your application.
If the trunk port has BNC connectors, use two 75-ohm coaxial cables with BNC connectors (not included).
Step 1 For an RJ-48 cable---Connect one end of the cable to the RJ-48 jack labeled T1/E1 on a light-green background.
For coaxial cables---Connect one end of the cables to the BNC connectors labeled E1 on a light-green background.
Step 2 Connect the other end of the cable(s) to the network demarcation device (telco demarc or equivalent).
| Install Chassis and Connect Cables (continued) |

If your Cisco MC3810 supports BRI S/T backup, connect the BRI S/T backup port to the ISDN network.
Use an 8-conductor straight-through cable (not included).
Step 1 Connect one end of the cable to the port labeled BRI 0 S/T on an orange background.
Step 2 Connect the other end of the cable to the S/T interface of the NT1.
Step 3 If the NT1 is not already connected to the ISDN network, connect the U interface of the NT1 to the ISDN wall jack
(U interface).
| Install Chassis and Connect Cables (continued) |

You can connect the serial 0 port to a Frame Relay network or to user equipment.
You can connect the serial 1 port to user equipment.
Use one of the Cisco serial transition cables (not included). Select the cable to match both of the following parameters:
See the Cisco MC3810 Series Multiservice Access Concentrators Hardware Installation Guide for information about selecting these cables.
Step 1 Connect the 60-pin connector of the serial transition cable to the Cisco MC3810 serial port to be used for this interface.
Step 2 Connect the other end of the serial transition cable to the CSU/DSU, synchronous modem, or video codec.
| Install Chassis and Connect Cables (continued) |

If you are using a 10BaseT Ethernet LAN, connect the Ethernet 0 port to the Ethernet hub.
Use a standard, straight-through, 10BaseT Ethernet cable (not included).
Step 1 Connect the cable to the Ethernet 0 port (yellow).
Step 2 Connect the other end of the cable to an Ethernet hub.
| Install Chassis and Connect Cables (continued) |

Connect analog voice ports as follows:
Use an RJ-11-to-RJ-11 standard telephone cable
(not included) for each FXO or FXS port.
Use 8-conductor, straight-through cables with modular connectors (not included) for E&M ports. For 4-wire E&M conforming to ETSI CTR17, use a CTR17 adapter (not included) between the cable and the E&M port.
Step 1 Select the appropriate cable. (See information at left.)
Step 2 Connect one end of the cable to the FXS, FXO, or E&M port, as required.
Step 3 Connect the other end of the cable to the matching equipment or line.
| Install Chassis and Connect Cables (continued) |

If your Cisco MC3810 has a T1/E1 digital voice port, connect it to a digital PBX.
If the digital voice port has an RJ-48 jack, use an RJ-48-to-RJ-48 rollover cable (not included), or a special cable if required for your application.
If the digital voice port has BNC connectors, use two 75-ohm coaxial cables with BNC connectors (not included).
Step 1 For an RJ-48 cable---Connect one end of the cable to the RJ-48 jack labeled T1/E1 on a tan background.
For coaxial cables---Connect one end of the cables to the BNC connectors labeled E1 on a tan background.
Step 2 Connect the other end of the cable(s) to the digital PBX.
| Install Chassis and Connect Cables (continued) |

If your Cisco MC3810 has BRI S/T voice ports, connect them to a Private Integrated Services Network Exchange (PINX).
The BRI voice ports are wired as terminal equipment (TE).
Step 1 Connect one end of each cable to the appropriate BRI S/T voice port on the BRI voice module (BVM). Ports are labeled BRI 1 through BRI 4 on an orange background.
Step 2 Connect the other end of each cable to the appropriate port on the PINX.
| Install Chassis and Connect Cables (continued) |

If your Cisco MC3810 has a video dialing module (VDM), connect the VDM port and one of the Cisco MC3810 serial ports to the video codec.
For the dialing interface, use an RS-366 cable with one 26-pin connector and one DB-25 connector (included with VDM).
For the video data connection, use a Cisco V.35 DCE serial transition cable with ringing indicator (RI) (included with VDM).
Step 1 Connect the 60-pin connector of the V.35 serial cable to the Cisco MC3810 serial port to be used for this interface.
Step 2 Connect the other end of the V.35 serial cable to the video data port of the video codec.
Step 3 Connect the 26-pin connector of the RS-366 cable to the VDM port (dark blue).
Step 4 Connect the DB-25 connector of the RS-366 cable to the dialing port of the video codec.
| Install Chassis and Connect Cables (continued) |

If you are using a local PC or ASCII terminal to configure your Cisco MC3810, connect it to the console port.
Use the light-blue RJ-45-to-RJ-45 rollover cable (included) and a terminal adapter (included):
Step 1 Connect the appropriate adapter labeled TERMINAL to the communication port (usually labeled COM) on your PC or terminal.
Step 2 Connect one end of the cable to the terminal adapter.
Step 3 Connect the other end to the console port (light blue) on the Cisco MC3810.
When you are finished, continue to the "Connecting the Power Cable" section.
| Install Chassis and Connect Cables (continued) |

If you are using a remote PC or ASCII terminal to configure your Cisco MC3810, connect the modem (not included) to the auxiliary port.
Use the light-blue RJ-45-to-RJ-45 rollover cable (included) and an RJ-45-to-DB-25 modem adapter (included).
Step 1 Connect the adapter labeled MODEM to your modem.
Step 2 Connect one end of the cable to the modem adapter.
Step 3 Connect the other end of the cable to the auxiliary port (black) on the Cisco MC3810.
When you are finished, continue to the "Connecting the Power Cable" section.
| Install Chassis and Connect Cables (continued) |

Your AC-powered Cisco MC3810 requires the following AC power:
Step 1 Connect one end of the power cord to the power connector on the rear panel of the Cisco MC3810.
Step 2 Connect the other end of the power cord to the power outlet.
When you are finished, continue to the "Get Site Information" section.
| Get Site Information |
This table provides space to write down information you need to run the System Configuration Dialog (also called the setup script).
| Item | Ask Your Network Administrator | Enter the Information in This Column |
1 | What do you want to name the Cisco MC3810 (to distinguish it from other Cisco devices on your network)? |
|
2 | What should the encrypted enable secret password be? |
|
3 | What should the nonencrypted enable password be? |
|
4 | What should the password for remote console (Telnet) access be? This is referred to as the virtual terminal password (Telnet password). |
|
5 | Do you want to configure the Cisco MC3810 for: |
|
| SNMP?
|
|
| IP? |
|
| IGRP routing?
|
|
| IPX?
|
|
| Bridging? |
|
6 | Do you want to configure the modems for: |
|
| Default chat script? |
|
| Dial-in IP SLIP/PPP access? |
|
| Dynamic IP address? |
|
| Default IP address? |
|
| TCP header compression? |
|
| Routing updates on async lines? |
|
| Async IPX? |
|
7 | Will you be using the Ethernet 0 (10BaseT) interface? |
|
| What is the IP address? |
|
| How many bits in the subnet mask? |
|
| Configure IPX on this interface?
|
|
| Power Up the Cisco MC3810 |
You are ready to power up the Cisco MC3810 if it meets these requirements:
Perform this procedure to power up your Cisco MC3810 and verify that it goes through its initialization and self-test. When this is finished, the Cisco MC3810 will be ready to configure.
Step 1 Power up your terminal or PC, and configure it for 9600 baud, 8 data bits, 1 stop bit, and no parity.
Step 2 Move the Cisco MC3810 power switch to the ON position.
The green LED next to the auxiliary port should go on and the fan should operate. If this does not happen, see the power-up procedure in the Cisco MC3810 Series Multiservice Access Concentrators Hardware Installation Guide.
The following message is displayed at the end of the boot-up messages.
--- System Configuration Dialog --- Would you like to enter the initial configuration dialog? [yes/no]:
rommon 1> prompt appears, your system has booted in ROM monitor mode. Follow the instructions in the appendix, "Booting in ROM Monitor Mode," in the Cisco MC3810 Multiservice Access Concentrators Software Configuration Guide before continuing with this procedure.
Continue to Section 5, "Perform Initial Configuration."
| Perform Initial Configuration |
This section shows how to perform some basic configurations from a local or remote console, using the Cisco command-line interface. For complete configuration procedures, see the Cisco MC3810 Series Multiservice Access Concentrators Software Configuration Guide.
Connect the Ethernet port (yellow) to a live Ethernet connection using a standard Ethernet cable with RJ-45 connectors; then use this procedure to set an IP address for the Ethernet port. After the Ethernet port has an IP address, you can configure the Cisco MC3810 remotely through a Telnet connection.
The starting point for this procedure is the System Configuration Dialog prompt (shown also on page 16):
--- System Configuration Dialog --- Would you like to enter the initial configuration dialog? [yes/no]:
To set the Ethernet port IP address, do the following:
| Step | Command | Purpose |
|---|---|---|
|
1 | Would you like to enter the initial | Terminate the System Configuration Dialog. |
|
2 | Press Return when you see the following prompt: Would you like to terminate Several messages are displayed, ending with a line flashfs[4]: Initialization complete. | Terminate autoinstall and continue setting the Ethernet IP address. |
|
3 | Press Return. | Bring up the router> prompt. |
|
4 | router> enable | Enable the privileged EXEC mode. |
|
5 | router# configure terminal | Enter global configuration mode. Note The default host name, "router," appears as part of the system prompt. To change the host name to another name such as "europa" that will then appear as the system prompt, enter hostname europa after Step 5 at the global configuration prompt---router(config)#.
|
|
6 | router(config)# enable password password | Set a password for the privileged EXEC mode. |
|
7 |
| Enter the interface configuration mode. |
|
8 |
| Enter the IP address and subnet mask you want for your Ethernet port. |
| Perform Initial Configuration (continued) |
| Step | Command | Purpose |
|---|---|---|
|
9 |
Messages similar to the following appear: %LINEPROTO-5-UPDOWN: Line protocol on | Activate the Ethernet port. |
|
10 | router(config-if)# exit | Return to global configuration mode. |
|
11 | router(config)# line vty 0 4 | Enter line configuration mode. |
|
12 | router(config-line)# password password | Set a password for remote access to the Cisco MC3810. |
|
13 | router(config-line)# end | Return to privileged EXEC mode. |
|
14 |
Messages similar to the following appear: Building configuration... Tablesize is 100 Configure call time [OK] router# | Save the configuration. |
Now that the Ethernet port has an IP address, you can either configure the Cisco MC3810 remotely with a Telnet connection, or you can continue using the console or auxiliary port.
| Perform Initial Configuration (continued) |
To configure basic settings for serial ports 0 and 1, do the following:
| Step | Command | Purpose |
|---|---|---|
|
1 | router> show interface serial | Display the default configuration. |
|
2 | router> enable | Enable the configuration. |
|
3 | router# configuration | Enter configuration mode. |
|
4 | router(config)# network-clock | Configure the network clock base rate setting. |
|
5 | router(config)# interface | Enter serial interface configuration mode. |
|
6 | router(config-if)# clock rate | |
|
7 | router(config-if)# no shutdown | Activate the serial port. |
|
8 | Repeat Steps 5 through 7 to configure the other serial port. | |
|
9 | router(config-if)# exit | Exit interface configuration mode. |
|
10 | router(config)# exit | Exit configuration mode. |
|
11 | router> show interfaces serial | Display the serial port configuration to verify the new settings. |
| Perform Initial Configuration (continued) |
There can be two T1/E1 ports in a Cisco MC3810: a trunk port and a digital voice port.
The T1/E1 trunk port is physically located in the multiflex trunk module (MFT). It supports balanced T1 per ANSI T1.403, and it supports balanced and unbalanced E1 per ITU G.703. The MFT has a built-in CSU/DSU.
The T1/E1 digital voice port is physically located in the digital voice module (DVM). It supports a balanced T1 interface with a digital PBX, and it supports both balanced and unbalanced E1 interfaces with a digital PBX.
To configure the basic T1/E1 controller settings for T1/E1 ports, do the following for each T1/E1 port that is present:
| Step | Command | Purpose |
|---|---|---|
|
1 | router> configure terminal | Enter global configuration mode. |
router(config)# controller | Enter controller configuration mode. Specify whether your controller is E1 or T1, and enter the controller number. The controller number for a T1/E1 port in the MFT must be 0. The controller number for a T1/E1 port in the DVM can be 0 (if an MFT is not installed) or 1 (if an MFT is installed). | |
router(config-ctrl)# clock | Configure the controller clock source for a DS1 link. If the clock source is a network device attached to the T1/E1 port you are configuring now, select the line option. For any other clock source (internal or a network device attached to any other port) select the internal option. | |
router(config-ctrl)# | Enter a description of the controller, such as the destination or its application. The description can be up to 80 characters long. | |
|
5 | Repeat Steps 2, 3, and 4 for the other T1/E1 port, if it is installed. | |
When you have completed these basic settings, proceed to the appropriate section on the next page: "Configuring T1 Controller Settings" or "Configuring E1 Controller Settings" and configure the T1 or E1 controller.
| Perform Initial Configuration (continued) |
To configure T1 controller settings, do the following in controller configuration mode:
| Step | Command | Purpose |
|---|---|---|
|
1 | Configure the cable length setting by doing one of the following: | |
| router(config-ctrl)# cablelength | Configure the cable length if the length is 655 feet or shorter. |
| router(config-ctrl)# cablelength | Configure the cable length if the length is longer than 655 feet. |
|
2 | router(config-ctrl)# framing | Configure the DS1 link framing format. Extended SuperFrame format (esf) is required for ATM traffic. |
|
3 | router(config-ctrl)# linecode | Configure the line encoding format for the DS1 link. The b8zs setting is required for ATM traffic. |
|
4 | router(config-ctrl)# no shutdown | Activate the T1 controller. |
|
5 | router(config-ctrl)# exit | Exit controller configuration mode. |
|
6 | router(config)# exit | Exit configuration mode. |
|
7 | router> show controller T1 0 | Verify the controller configuration. |
To configure E1 controller settings, perform the following tasks in controller configuration mode:
| Step | Command | Purpose |
|---|---|---|
|
1 | router(config-ctrl)# {framing
| Configure the E1 framing format. If the trunk will be connected to a device in Australia, enter the australia option. |
|
2 | router(config-ctrl)# linecode | Configure the E1 line encoding format. The hdb3 setting is required for ATM traffic. |
|
3 | router(config-ctrl)# no shutdown | Activate the E1 controller. |
|
4 | router(config-ctrl)# exit | Exit controller configuration mode. |
|
5 | router(config)# exit | Exit configuration mode. |
|
6 | router> show controller E1 0 | Verify the controller configuration. |
| Perform Initial Configuration (continued) |
This section has separate procedures for analog, digital, and ISDN BRI voice ports. Use the analog procedure to configure voice ports on the analog voice module (AVM). Use the digital procedure to configure voice ports on a T1 or E1 line on a digital voice module (DVM) or multiflex trunk module (MFT). Use the BRI procedure to configure voice ports on the BRI voice module (BVM).
Before entering voice-port configuration mode, enter:
router> show voice port summary
This command brings up a list of the existing voice ports with their slot/port numbers, signaling types, and status.
To see the complete current configuration of an existing voice port, enter the following command:
router> show voice port slot/port
The following table summarizes the physical and logical characteristics of the Cisco MC3810 voice ports:
| Voice Interface Type | Hardware Module | Voice-Port Identification | |
|---|---|---|---|
| Slot Number | Port Numbers | ||
Analog | AVM | 1 | 1-6 |
BRI | BVM | 1-4 | 1-2 |
Digital:
| MFT | 0 | 1-24 (for T1) 1-15 and 17-31 (for E1) |
Digital:
| DVM | 1 | 1-24 (for T1) 1-15 and 17-31 (for E1) |
| Perform Initial Configuration (continued) |
To configure the basic analog voice-port settings, perform the following tasks:
| Step | Command | Purpose |
|---|---|---|
|
1 | router> configure terminal | Enter global configuration mode. |
router(config)# voice-port slot/port | Enter voice-port configuration mode, and specify the voice port you want to configure by entering the logical slot number and port number (see table on page 23). The commands entered in Steps 3 through 4 affect only the voice port you specify here. The slot number for analog voice ports on the Cisco MC3810 is | |
|
3 | router(config-voiceport)# codec | (Optional) Configure the voice-port compression mode. The g729ar8 value is the default and is recommended. Simultaneously active on-net voice call support by compression mode:
Nominal data rates for compression modes:
|
|
4 | router(config-voiceport)# connection | Configure the voice-port connection mode type. If the connection is to a PBX, use the tie-line option, If the connection is for Private Line Auto Ringdown (PLAR) use the plar option. If the connection is for PLAR Off-Premises eXtension (OPX), use the plar-opx option. With this option, the local voice port will provide a local response before the remote voice port receives an answer, and FXO interfaces will not answer until the remote side answers. |
|
5 | If you want to change the default signaling type for the voice port, choose one of the following: | |
| router(config-voiceport)# signal | Configure the signaling type for FXO and FXS voice ports. The default is loop-start. |
| router(config-voiceport)# signal | Configure the signaling type for E&M voice ports. The default is wink-start. |
|
6 | router(config-voiceport)# dial-type | Change the transmit dial type if necessary (FXO and E&M ports only). The default is dtmf. Only FXO and FXS ports transmit dial pulses. |
| Perform Initial Configuration (continued) |
| Step | Command | Purpose |
|---|---|---|
|
7 | router(config-voiceport)# cptone | Configure the voice port for the local territory's call progress tone setting. The call progress tone setting determines the settings for dialtone, busytone, and ringback tone. The default for this command is northamerica. For a list of supported countries, see the Cisco IOS Voice, Video, and Home Applications Command Reference. |
router(config-voiceport)# | Activate the voice port. You should activate only those voice ports you are planning to use. | |
|
9 | Exit from voice-port configuration mode and repeat Steps 2 through 8 for the remaining analog voice ports. | |
To configure voice-port tuning options, see the section "Configuring Voice-Port Tuning Options" in the "Configuring Voice Ports" chapter of the Cisco MC3810 Multiservice Access Concentrators Software Configuration Guide.
To configure dial peers, see the applicable voice service configuration section in the Cisco MC3810 Multiservice Access Concentrators Software Configuration Guide.
To configure the basic digital voice-port settings, perform the following tasks:
| Step | Command | Purpose |
|---|---|---|
|
1 | router> configure terminal | Enter global configuration mode. |
|
2 | router(config)# controller {t1 | e1}
| Enter controller configuration mode. Specify whether your controller is E1 or T1, and enter the controller number:
|
router(config-controller)# mode cas | ||
router(config-controller-cas)# | Configure a list of timeslots to form a CAS group for the T1/E1 line. The "melcas" options are supported only on E1 and apply to the Mercury Exchange Limited (MEL) standard, used primarily in the United Kingdom. When configuring a CAS group for a T1/E1 line to a PBX, make sure that the channel numbers match the PBX channels. | |
|
5 | Repeat Step 3 or 4 for each CAS group. After CAS groups are defined, exit CAS controller configuration mode. | |
| Perform Initial Configuration (continued) |
| Step | Command | Purpose |
router(config)# voice-port slot/port | Enter voice-port configuration mode, and specify the voice port you want to configure by entering the logical slot number and port number (see table on page 23). The following commands affect only the voice port you specify here. | |
|
7 | router(config-voiceport)# | Change the transmit dial type if necessary (FXO and E&M ports only). The default is dtmf. Only FXO and FXS ports transmit dial pulses. |
|
8 | router(config-voiceport)# | Change the companding if necessary. The default is u-law (the North American mu-law ITU-T PCM encoding standard). Specify a-law to use the European a-law ITU-T PCM encoding standard. |
router(config-voiceport)# | Activate the voice port. You should activate only those voice ports you are planning to use. | |
|
10 | Exit from voice-port configuration mode and repeat Steps 6 through 9 for the remaining digital voice ports. | |
To configure voice-port tuning options, see the section "Configuring Voice-Port Tuning Options" in the "Configuring Voice Ports" chapter of the Cisco MC3810 Multiservice Access Concentrators Software Configuration Guide.
To configure dial peers, see the applicable voice service configuration section in the Cisco MC3810 Multiservice Access Concentrators Software Configuration Guide.
| Perform Initial Configuration (continued) |
You can test your analog or digital voice-port configuration by doing the following:
If you are having trouble connecting a call and you suspect the problem is associated with voice-port configuration, you can try to resolve the problem by performing the following:
| Perform Initial Configuration (continued) |
To configure the basic ISDN BRI voice-port settings, perform the following tasks:
| Step | Command | Purpose |
|---|---|---|
|
1 | router> configure terminal | Enter global configuration mode. |
|
2 | router(config)# | Configure the global ISDN switch type as basic-qsig for the BRI voice ports. Note You can configure the ISDN switch type in either global or interface configuration mode. If you configure it here in Step 2, it specifies the switch type for all four BVM ports. If you configure it in Step 4, it specifies the switch type for a single interface. The switch type specified in Step 4 for any individual interface will override the globally specified switch type. |
router(config)# | Enter interface configuration mode to configure parameters for the specified BRI voice port. The number can be from 1 to 4. | |
|
4 | router(config-interface bri 1)# | If the service provider switch type for this BRI port is different from the global ISDN switch type, configure the interface ISDN switch type to match the service provider switch type. The interface ISDN switch type overrides the global ISDN switch type on this interface. |
|
5 | router(config-interface bri 1)# | Configure the Layer 2 and Layer 3 port protocol emulation:
|
|
6 | router(config-interface bri 1)# | Configure the Layer 1 port mode emulation and the clock settings:
|
|
7 | router(config-interface bri 1)# | Turn on or off the power supplied from an NT-configured port to a TE device. The default is no line-power. |
|
8 | router(config-interface bri 1)# | If this BRI voice port is configured as TE, and you want it to act as a clock slave and recover clock from the network NT device, set it to high. If this BRI voice port is configured as TE, and you do not want it to recover clock from the network NT device, set it to low. This command is not used if this port is configured as NT with the command isdn layer1-emulate network. |
| Perform Initial Configuration (continued) |
| Step | Command | Purpose |
|---|---|---|
|
9 | router(config-interface bri 1)# | Activate overlap signaling to the destination PBX. |
|
10 | router(config-interface bri 1)# | Specify the cause code to pass to the PBX when a call cannot be placed or completed because of internal network failures. Possible values are from 1 to 127. |
router(config-interface bri 1)# | (Optional) Configure the BRI voice port to include the Sending Complete information element in the outgoing call setup message. This command is used in some geographic locations, such as Hong Kong and Taiwan, where the Sending Complete information element is required in the outgoing call setup message. | |
|
12 | Exit from interface configuration mode and repeat Steps 3 through 11 for the remaining BRI voice ports. | |
You can test your BRI voice-port configuration by doing the following:
To configure dial peers, see the applicable voice service configuration section in the Cisco MC3810 Multiservice Access Concentrators Software Configuration Guide.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Jul 15 10:27:27 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.