Installing and Configuring the Cisco AccessPath-TS3 Model 531 Integrated Access System

Installing and Configuring the Cisco AccessPath-TS3 Model 531 Integrated Access System

This chapter guides you through the installation and configuration of the Cisco AccessPath-TS3 Model 531 Integrated Access System hardware.

Before you install and configure your system, you should have completed the procedures in Chapter 2, "Preparing for Installation." These procedures include gathering the required tools (see the section "Tools Required") and drilling seismic safety holes (see the section "Prepare Seismic Safety Holes").

This chapter includes the following sections:

 
Warning This unit is intended for installation in restricted access areas. A restricted access area is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.  
Warning Only trained and qualified personnel should be allowed to install or replace this equipment.
 
Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.  
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.

Uncrate the System

The Cisco AccessPath-TS3 Model 531 system is shipped inside a cardboard crate, which also contains a wooden ramp used to roll the Cisco AccessPath-TS3 Model 531 system off the shipping pallet. The system is enclosed in 2 system-length pieces of corrugated material connected by plastic clips that run the length of the carton. A third piece of cardboard is secured to the top of the twin side pieces by metal banding straps. The system is bolted to its shipping pallet. See Figure 3-1.


Figure 3-1: Packing Crate for the Cisco AccessPath-TS3 Model 531 Integrated Access System


 
Warning You should wear protective gloves and safety glasses when handling the shipping crate banding while unpacking the system. The straps that connect the packaging material are capable of inflicting damage to your skin or eyes if not handled properly.

To uncrate the Cisco AccessPath-TS3 Model 531 system:

Step 1 Remove the banding straps and the top of the cardboard packaging.


Figure 3-2:
Removing the Banding Straps and Cardboard Top


Step 2 Remove the corrugated cardboard pieces from around the system:


Figure 3-3:
Removing the Main Packing Pieces from the Cisco AccessPath-TS3 Model 531 Integrated Access System



Note The packing materials can be reused. Cisco recommends that you retain these materials in the event that you move the system to another location in the future. Discard the packing materials only if you are sure that you will never ship the system again.

Remove the Accessories, Doors, and Ramp


Figure 3-4: Doors, Ramps and Accessories Packed in Shipping Configuration


Step 1 Remove the accessory kits. A single piece of banding secures these kits to the pallet at the front of the system. Cut the banding and lift the kits out. The kits and their contents are listed in Table 3-1.


Table  3-1: Accessory Kits
Kit Type Contents
Documentation

  • Cisco AccessPath-TS3 Model 531 Integrated Access System Quick Start Guide

  • Cisco AccessPath-TS3 Model 531 Integrated Access System Hardware Installation Guide

  • Cisco AccessPath-TS3 Model 531 Integrated Access System Hardware Scaling and Configuration Guide

  • Cisco AccessPath-TS3 Integrated Access System Software Configuration Guide

  • Regulatory Compliance and Safety Information for the Cisco AccessPath-TS3 Integrated Access System

  • Release Notes for Cisco IOS software

(North America only) AC modem1

  • 28.8 Kbps out-of-band modem

  • Rolled, modular RJ-45 cable

  • ADP RJ45/DSUB/ RP 8P Module (a modem adapter used to attach the cable to the back of modem)

  • Power cord, 10A/125V, 40 inches (102 cm) in length, 320-C 14 and NEMA 5-15R

  • Velcro strap, to attach the modem to the system

(Optional--High-End Extended configurations only) Expansion cable23

Five 12-foot (3.66 m) cables for connecting the 2 cabinets:

  • 2 cables (72-1460-xx) for System Controller (management) connections

  • 1 cable (72-1458-xx) for Ethernet (data) connections

  • 2 cables (72-1459-xx) for Ethernet (data) connections

(Optional) Backhaul port adapter

  • Backhaul port adapter

  • Backhaul port adapter cable(s)

  • Backhaul port adapter documentation

(Optional--DC configurations only) DC inlet clamp kit

  • Strain relief bracket

  • Strain relief cover

  • 2 short 6-32 screws (to mount bracket to cabinet)

  • 5 long 6-32 screws (to mount the cover to the bracket)


1 To install the modem, see the section "Install the AC-Powered Out-of-Band Modem (North America Only)".
2 For additional information on these cables, refer to the section "Table B-2 shows the channel mapping in the connection between Access Server Shelves 1 through 7 and patch panel 1." in Appendix B, "Cabling Specifications."
3 These cables are designed for customers such as Telcos who plan to run their cabinet-to-cabinet cabling through a ceiling harness. You can also connect the cabinets directly by running shorter cables that you provide between the cabinets. The cables can be of variable length, but must have the appropriate cable assemblies and pinouts as detailed in the section "Cabinet Interconnect Cable Assemblies and Pinouts" in Appendix B, "Cabling Specifications."

Note  When you order individual system components to add them to a Cisco AccessPath-TS3 Model 531 system (for example, a Catalyst 5002 switch or Cisco 7206 router), you will receive accompanying accessory kits with required components. See the Cisco AccessPath-TS3 Model 531 Integrated Access System Hardware Scaling and Configuration Guide for more information.

Step 2 Refer to the warning below and Figure 3-5 to remove the doors from their shipping positions. (When the system is shipped, each door is set against 1 side of the system and placed inside a foam piece.)

 
Warning When you remove the first door from its retainer, the packing material on top of the unit might lift up and inadvertently release the door on the opposite side from its retaining wrapping. This can result in the door falling and striking equipment or persons. Make sure that you assign someone to hold the second door as you remove the first door.
Figure 3-5: Removing the Doors from Their Shipping Positions


To remove the doors from their shipping position:


Step 3 Remove the 2 wooden ramp legs from the sides of the pallet and lock them in place at the front of the pallet. (The ramp comes in 2 identical pieces, which are shipped strapped to opposite sides of the system next to the doors. See Figure 3-4.)

To remove the ramp and attach it to the shipping pallet:



Figure 3-6: Attaching the Ramp to the Shipping Pallet


Unbolt the System from the Pallet

The Cisco AccessPath-TS3 Model 531 system is packed and shipped bolted to the pallet. 4 standard hex packing bolts secure the bottom of the system to the shipping pallet.

You can remove the bolts in any order, but be sure to remove all 4.


Note If you have not yet drilled seismic safety bolt holes in your floor, see the section "Prepare Seismic Safety Holes" in Chapter 2, "Preparing for Installation" or the Cisco AccessPath-TS3 Model 531 Integrated Access System Quick Start Guide.

Remove the packing bolts:

Step 1 Locate the first of the 4 bolts that secures the Cisco AccessPath-TS3 Model 531 system to the pallet. Each bolt is placed in a corner location on the pallet.

Step 2 Using a standard 7/8-inch socket wrench, loosen the nut that secures the first bolt to the cabinet. Remove the nut and set it aside.

Step 3 Remove and save the 2-inch-by-3-inch (5.1 cm.-by-7.6 cm.) load plates that sit beneath the nut. (You will need these plates for seismic safety bolting and if you ever need to ship the system to another location.)

Step 4 Push the loosened bolt through the pallet so that it falls to the floor.

Step 5 Repeat Step 1 through Step 4 for the remaining bolts.


Note In order to move the system off the pallet and down the ramp, make sure that all 4 bolts drop completely through the pallet to the floor and do not obstruct the system.

Prepare the System for Transport

Before you can move the Cisco AccessPath-TS3 Model 531 system, you must first:

    1 . Raise the system by lowering the attached caster assemblies until the wheels touch the pallet.

    2 caster assemblies are attached to the system--1 each at the front and at the rear. The main horizontal plate of these assemblies contains a wormscrew. By turning this wormscrew, you raise the system, providing clearance for it to roll off the pallet, down the ramp, and to the installation site.


    2 . Align the wheels with the ramps.

 
Caution When you move a single caster assembly (front or back), the corresponding assembly also moves. In order to keep the system in balance and eliminate any chance that you might tip the system over, Cisco recommends that 2 people work together to simultaneously raise or lower the caster assemblies.
Figure 3-7:
Lowering the Casters to Raise the System


To prepare to move the system off the pallet and to the installation site:

Step 1 Assign 1 person to the caster assembly at the front of the system and 1 person to the assembly at the back of the system. Refer to Figure 3-7.

Step 2 Simultaneously lower both caster assemblies:

Step 3 Use your hands to align the front and back caster wheels so that they are:

 
Caution Be sure that no one is turning the wormscrew on the caster assembly when you align the wheels.

Step 4 Continue lowering the caster assemblies until the cabinet reaches its maximum height (approximately 1 1/2 inches or 3.8 cm above the pallet surface). Raising the system provides the clearance necessary for passage down the ramp and across a flat surface.

Move the System to the Installation Location

You are ready to move the Cisco AccessPath-TS3 Model 531 system down the ramp and to the installation location. Verify that all 4 packing bolts have been removed and stored and that the caster wheels are aligned.

 
Warning We recommend that 5 people work together to roll the unit down the ramp and to the installation site. Using fewer than 3 people will substantially increase the risk to personnel and equipment.
Figure 3-8: Moving the System Off the Pallet


 
Warning The cabinet has a high center of gravity. Use care when moving it.

To move the Cisco AccessPath-TS3 Model 531 system from the pallet to the installation site:

Step 1 Position yourself and the assisting personnel in the most efficient configuration. If, as recommended, you have assigned 5 people to this task, position 4 at the corners of the system. The fifth person should monitor and supervise the procedure.

 
Caution It is important that you choose the right speed at which to move the system down the ramp and onto the floor. The ideal rate will allow you to maintain maximum control of the system while reaching the floor surface quickly. Avoid rolling the system so quickly that it is difficult to control when it reaches the floor.

Step 2 Roll the system down the ramp within the guidelines provided in the preceding Caution.

 
Warning
Caution Before you move the system across the floor and to the specified installation site, check for obstacles or protrusions that might obstruct the movement of the system or damage it. Cisco recommends that you select a clear path to the installation site. Navigate around any obstacles with care.

Step 3 After the system has reached the flat surface of the floor, roll it to the installation site. Push the system quickly enough to maintain momentum, but not so quickly that you have difficulty turning or slowing the system.

Step 4 When you have reached the installation site, install the 4 seismic safety anchors in each hole.

Step 5 Move the system into position over the seismic safety bolt holes.


Note If you have not yet drilled seismic safety bolt holes in your floor, see the section "
Prepare Seismic Safety Holes" in Chapter 2, "Preparing for Installation" or the Cisco AccessPath-TS3 Model 531 Integrated Access System Quick Start Guide.

Install the Cabinet

To complete your installation of the Cisco AccessPath-TS3 Model 531 system, you must bolt the system to the floor and remove the casters used to transport the system to the site.


Note  If you have drilled bolt-hole patterns that conform to the Network Equipment Building Systems (NEBS) standard, you must remove the Catalyst 5002 switch, then reinstall it after you have bolted the system to the floor. To remove the switch, follow the instructions in the Cisco AccessPath-TS3 Model 531 Integrated Access System Hardware Scaling and Configuration Guide. (If you have an Entry configuration, you will not have a Catalyst 5002 in the system.)

If you have used the Cisco-recommended drilling pattern, you will not need to remove the Catalyst 5002 switch.

To lower the Cisco AccessPath-TS3 Model 531 system into place:

Step 1 Make sure that the seismic safety anchors have been placed in each hole. If you have not yet placed the anchors in each hole, push the system away from the installation site and place each of the 4 steel casings in the holes.

Step 2 Align the mounting positions in the cabinet with the corresponding holes in the floor.


Figure 3-9: Seismic Safety Bolting Assembly


Step 3 Collect the 4 threaded rod assemblies that you will use to secure the system to the floor. Cisco recommends that you use a bolting kit supplied by HILTI. The HILTI kit consists of:

In addition, you will use the load plate you saved when you unbolted the system from the pallet.


Step 4 Locate the mounting position on the base of the cabinet. Place a threaded rod in the hole and (using your hand) turn it counterclockwise until it no longer moves (the rod should have entered a minimum of 5 threads into the casing).

Step 5 Repeat Step 4 for the remaining threaded rods, being careful not to tighten any down until you have installed all of the rods, lowered the system to the floor, and removed both caster assemblies.

Step 6 Raise the casters to lower the system completely to the floor:


Figure 3-10:
Disassembling the Casters


 
Warning Each caster assembly weighs approximately 100 pounds. 2 people should participate in removing each assembly in order to prevent bodily injury. Exercise caution when pulling the assemblies away from the system.

Step 7 Disassemble the caster assemblies by following these steps:

Step 8 Tighten each of the threaded rods and secure them to the floor using a torque wrench.

The parts that make up each threaded-rod assembly include the threaded rod, a rectangular plate with a hole in its center, a washer and a 2-part nut assembly, the top portion of which detaches when you tighten the rod into place.


 
Caution Because these nuts will shear when 60 ft-lb are reached, you should use a box-end or 19mm socket wrench to tighten them. Be careful not to injure your hands and fingers during this process.

Verify Signal Cabling

Although the Cisco AccessPath-TS3 Model 531 system arrives precabled, you should check to make sure that all the cables are connected and properly seated.

There are 2 kinds of cables:

In this section, we will discuss the signal cables. Power cabling is discussed in the section "Connect Power".

Table 3-2 describes the signal cables, providing their part numbers, functional descriptions, and labels for the cable ends. The labels describe signal cables connection between the Cisco AccessPath-TS3 Model 531 system shelves and the signal harness.

For illustrations of the signal harness, see Figure 3-11 and Figure 3-12. For information on cable assemblies and pinouts, see Appendix B, "Cabling Specifications."


Table  3-2: Signal Cable Mapping for the Cisco AccessPath-TS3 Model 531 Integrated Access System
Device Cable Part Number Cable Description J1 Label J2 Label Signal Harness Port
Patch Panels 72-1466-xx PRI (64 Pin to four 25 Pins) PP_PRI P1-P4 J1 through J4 and J9 through J12

Access Server Shelves
(Cisco AS5300s)

72-1463-xx Console/Ethernet (25 Pin to three RJ-45s) AS_CON/ETH AS_CON
AS_10/100BT
AS_10BT
Even-numbered connectors from J14 through J40
72-1464-xx 4 PRI
(four RJ-45s)
AS_4PRI AS_PRI 0-
AS_PRI3
Odd-numbered connectors from J13 through J39

Router Shelves (Cisco 7206s)

72-1462-xx 10/100BaseT (50 Pin to twelve RJ-45s) RS_ETH RS_ETH 5/2-5/13 (Ports 1-12) J46 (Router Shelf 1)
J42 (Router Shelf 2)
72-1465-xx Console/Ethernet (15 Pin to two RJ-45s) RS_CON/ETH P1: RS_CON
P2: RS_ETH
J41
J44
72-1487-xx1 10/100BaseT (50 Pin to twelve RJ-45s) SW_FE 1-12 RS01_ETH 3/2-3/13 (Ports 1-12) J56
72-1489-xx 100BaseT Controller (RJ-45 to RJ-45) RS_5/0 RS_0/0 Port-to-Port
72-1490-xx 100BaseT Inteconnect (RJ-45 to RJ-45) RS01_5/1 RS02_5/1 Port-to-Port

System Controller (Cisco 3640)

72-1457-xx Ethernet (DB9 to two RJ45s) SC_ETH SC_ETH1
SC_ETH0
J48
72-1461-xx Asynchronous
(68 Pin SCSI)
SC_ASYNC SC_ASYNC J49 through J52

Switch Shelf (Catalyst 5002)

72-1462-xx 10/100BaseT (50 Pin to twelve  RJ-45s) SW_FE SW_FE 1-12
SW_FE 13-24
J56
J57
72-1486-xx Console/Ethernet (25 Pin to three RJ-45s) SW_CON/FE SW_SUP_CON
SW_SUP_FE 1
SW_SUP_FE 2
J55

1 Entry configuration only. This cable is used only with Cisco Ethernet switching port adapter (PA-12E/2FE) in slots 3 and 4 of the Entry configuration's Router Shelf.

The signal harness is the conduit by which the devices communicate with one another. Cables are routed from each device into specified connectors on the signal harness. The signals are transmitted through the harness, enabling communications between the system devices.

Figure 3-11 shows the position of the signal harness in the cabinet. Figure 3-12 shows a detailed view of the signal harness, including the connector descriptions that have been silk screened onto it.


Figure 3-11: Cisco AccessPath-TS3 Model 531 Integrated Access System Signal Harness



Figure 3-12:
Cisco AccessPath-TS3 Model 531 Integrated Access System Signal Harness Connector Descriptions


Verify Signal Cabling within the Cabinets

Check the signal cabling within the cabinet (or cabinets) of your Cisco AccessPath-TS3 Model 531 system.


Note For complete listings of Cisco AccessPath-TS3 Model 531 system cable connections and cable assembly diagrams and pinouts, see Appendix B, "Cabling Specifications."
 
Warning The ports labeled Ethernet, 10BaseT, Serial, Console, and auxiliary contain safety extra-low voltage (SELV) circuits. PRI circuits are treated like telephone-network voltage (TNV) circuits. Avoid connecting the SELV circuit to the TNV circuits.

Check the signal cabling for the system devices in the following order. You may use either of the following procedures to perform your verification.

Make sure that all cables are connected where they should be and that all of the cables are firmly seated.

Summary Signalling Cable Verification Procedures

Step Verify cabling to Cable Should be connected from the shelf at To the signal harness at

1 . 

Patch panels

72-1466-xx

J1-J4 J2 (Patch panel 1)
J10 (Patch panel 2)
J5-J7 J1 (Patch panel 1)
J9 (Patch panel 2)

2 . 

Access Server Shelves(Figure 3-14)

72-1464-xx PRI 0-PRI 3 Odd-numbered connectors, J13-J39
72-1463-xx

  • Console 0

  • Fast Ethernet 0

  • Ethernet 0

Even-numbered connectors, J14-J40

3 . 

Router Shelves
(Figure 3-15 and Figure 3-16)

72-1462-xx The 12 Ethernet switching ports in slots 5 and 6 J46 (Router Shelf 1)
J42 (Router Shelf 2)
72-1465-xx

  • Console 0

  • Ethernet 0

J44 (Router Shelf 1)
J41 (Router Shelf 2)

72-1489-xx

  • Router Shelf Fast Ethernet port 5/0

  • Router Shelf 1 Fast Ethernet port 3/01

  • Router Shelf port 0/02

  • Router Shelf 1 port 0/02

72-1490-xx3

Router Shelf 1 Fast Ethernet port 5/1 Router Shelf 2 Fast Ethernet port 5/14
72-1487-xx1 The 12 Ethernet switching ports in slots 3 and 4 J56

4 . 

System Controller (Figure 3-18)

72-1461-xx

  • Async 0-7

  • Async 8-15

  • Async 16-23

  • Async 24-31

  • J49

  • J51

  • J50

  • J52

72-1457-xx

Ethernet 0-1 J48

5 . 

Switch Shelf (Figure 3-19)

72-1462-xx The 24 Ethernet switching ports, Fast Ethernet 1-12 and 13-24 J56
J57
72-1486-xx

  • Console

  • Ethernet (Fast Ethernet ports 1 and 2)

J55


1 Entry configurations only.
2 This connection is made from one port to another on the identical Router Shelf. There is no connection to the signal harness.
3 Dual Router Shelf configurations only.
4 This connection is made from one Router Shelf to the other in dual Router Shelf configurations. There is no connection to the signal harness.

Detailed Signalling Cable Verification Procedures

Step 1 Check cabling to the patch panels. 2 cables (72-1466-xx) should be connected from each patch panel. These cables route T1/E1 PRI connections into the system. (See Figure 3-13.)


Figure 3-13: Patch Panel Cabling


Step 2 Check cabling to the Access Server Shelves:


Figure 3-14: Access Server Shelf Cabling


Step 3 Check cabling to the Router Shelf (or Shelves):


Figure 3-15: Router Shelf Cabling


In addition, depending on your configuration, you may need to check the following:



Figure 3-16: Router-to-Router Connections


This cable, which is identical in function and purpose to 72-1462-xx, attaches to the second Cisco Ethernet switching port adapter (PA-12E/2FE), which is not included in the Router Shelf in the Midrange, High-End, and High-End Extended configurations.

Figure 3-17: Entry Configuration Router Shelf Cabling



Step 4 Check the System Controller cabling:


Figure 3-18: System Controller Cabling



Step 5 All configurations except Entry configurations. Check the cabling on the Switch Shelf:


Figure 3-19: Switch Shelf Cabling


Step 6 Check the expansion cabling if you have a High-End Extended Cabinet Configuration. See the section "Connect Signal Cabling Between Cabinets (High-End Extended Configuration Only)" for more information on expansion cabling.

Connect Signal Cabling Between Cabinets (High-End Extended Configuration Only)

The Cisco AccessPath-TS3 Model 531 system comes in 4 different configurations, the most advanced of which is the High-End Extended configuration.

Customers who order the High-End Extended configuration must cable the devices in the secondary cabinet to those in the primary cabinet using 5 expansion cables connected to specific locations within each signal harness. The maximum space between the cabinets is 30 feet (9.14 m).

Use Table 3-3 Figure 3-20 to connect the expansion cables to the appropriate connectors on the 2 signal harnesses (in the primary and secondary cabinets).


Table 3-3: Expansion Cabinet Cabling
Step Connect Cable Part Number From Primary Cabinet Signal Harness Location To Secondary Cabinet Signal Harness Location
1 72-1459-xx J43 J46
2 72-1458-xx J47 J45
3 72-1460-xx J53 J49
4 72-1460-xx J54 J50
5 72-1459-xx J58 J56

Figure 3-20: Connecting Signal Cabling Between Cabinets



Note For additional information on the expansion cables, refer to the cabling diagrams in
Appendix B, "Cabling Specifications."

Install the AC-Powered Out-of-Band Modem (North America Only)

Cisco includes the AC-powered Microcom DeskPorte 28,800 Data/Fax Modem with the Cisco AccessPath-TS3 Model 531 system.

Installation and use of the out-of-band modem is optional; if you intend to use the modem as part of the Cisco AccessPath-TS3 Model 531 system, install it using the instructions in this section.

 
Timesaver If you do not wish to use the out-of-band modem, continue with the section "Connect Power".
Note The out-of-band modem is intended for use by customers in the United States and Canada with AC power. If you have the DC version of the Cisco AccessPath-TS3 Model 531 system and wish to use the modem for out-of-band management, you will be responsible for AC-to-DC conversion.

The Microcom User's Guide is included with the modem; refer to it for additional information about associated parameters, performance and features, and for information about Microcom technical support.

To install the modem in your Cisco AccessPath-TS3 Model 531 system:

Step 1 Empty the modem accessory kit and verify its contents. You should have the following items:

Step 2 Attach the power cable to the supplied extension cord, which converts a 2-pronged connector to a 3-pronged connector that fits the power strip.

Step 3 Insert the modem adapter (29-0881-xx) in the serial port at the back of the modem. Tighten the screws to secure the connection.

Step 4 Take the modem, velcro strap, and related installation components to the back of your Cisco AccessPath-TS3 Model 531 system.

Step 5 If you have already attached the back door, open it by following the 4-step sequence in Figure 3-26.


Figure 3-21: Modem Location within Cabinet


Step 6 Locate the modem bracket found in the right rear corner of the system when viewed from the back (see Figure 3-21). This bracket, which forms a metal pouch for easy modem installation, is pre-mounted against the wall of the system.

Step 7 Position the modem above the metal pouch at the center of the bracket (see Figure 3-21).

Step 8 Insert the modem so that the ports and modem adapter are at the top of the device.


Figure 3-22: Securing the Out-of-Band Modem with the Velcro Strap


Step 9 Take the velcro strap (Figure 3-22) and loop it around the back of the modem and through the bridge lance that attaches to the outside of the installation pouch.

Step 10 Wrap the velcro tightly and press the strips together, securing the modem in the metal installation pouch.


Figure 3-23: Routing the Modem Power Cord From the Modem to the Power Strap


Step 11 Attach the power cord to the modem port located at the top left edge of the installed modem (see Figure 3-23). (If you have not connected the modem power cord to the supplied extension cord, do so now.)


Figure 3-24: Attaching the Modem to the System Controller Auxiliary Port


Step 12 Attach the modem serial connector to the System Controller:


Figure 3-25: Modem Ports


Step 13 Connect your external phone line. Insert 1 end of the line connector (RJ45) into the Line port shown in Figure 3-25 and the second connector end into a wall jack.

Step 14 Turn the modem on. You have established out-of-band management to your Cisco AccessPath-TS3 Model 531 system.

Install the Doors

Install the system doors:

Step 1 Install the front door near the signal harness side at the front of the cabinet. (The front door is the one with louvers. See Figure 3-4.) Place the bottom peg in first and then the top peg.

Step 2 Install the back door at the back of the cabinet. (The back door is the one with perforations. See Figure 3-4.) Place the bottom peg in first and then the top peg.

For an illustration of how to use the latching mechanism to open the doors, see Figure 3-26.


Figure 3-26: Opening One of the Doors


Connect Power

The Cisco AccessPath-TS3 Model 531 system comes in AC and DC versions. Follow the procedure below that corresponds to the system that you ordered.

Verify Your Site Meets Power Requirements

To connect power to the Cisco AccessPath-TS3 Model 531 system, you must first verify that your site meets the power requirements.

Power requirements, which help guarantee power redundancy for the Router Shelf and Switch Shelf:

Connect AC Power

For a Cisco AccessPath-TS3 Model 531 system equipped for AC power, the power is supplied to the various shelves through 7 power strips located on the right side of the Cisco AccessPath-TS3 Model 531 Integrated Access System, inside the front door.

 
Warning Read the installation instructions before you connect the system to its power source.
 
Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 20A U.S. (240 VAC, 16 to 20A international) is used on the phase conductors (all current-carrying conductors). The fuse or circuit breaker must have adequate safety approvals recognized by the country of use.  
Warning Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.
 
Warning This unit has more than 1 power cord. To reduce the risk of electric shock when servicing a unit, disconnect the power cord of the power strip that the unit is plugged into.  
Warning  The device is designed to work with TN power systems.
 
Warning The plug-socket combination must be accessible at all times because it serves as the main disconnecting device.

Step 1 Make sure that all of the shelves are turned OFF.

Step 2 Verify that the AC power connections are firm between the Cisco AccessPath-TS3 Model 531 system shelves and the power strip.

Check AC power cabling to the power strip in the following order, starting at the top of the rack:


Plug any unconnected power cords that come from Cisco AccessPath-TS3 Model 531 system shelves into the power strip. (These connections should have been made prior to shipping, but might have loosened or been disconnected during transit.)


Figure 3-27 shows the individual connections and corresponding silk screen markings for the AC power strip.



Figure 3-27:
AC Power Strip


Step 3 Connect each of the AC power input cables to a separate grounded power source.

This will require 7 dedicated 20A (100-127 VAC) or 10A (200-240 VAC) circuits per Cisco AccessPath-TS3 Model 531 system cabinet.


Step 4 You may turn each of the shelves ON, one at a time.

Connect DC Power

For a Cisco AccessPath-TS3 Model 531 system equipped for DC power, the power is supplied to the various shelves through a DC busbar. This busbar comes with the Cisco AccessPath-TS3 Model 531 system and is installed in the system cabinet.

 
Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.

Step 1 Verify that all of the shelves in the Cisco AccessPath-TS3 Model 531 system have been connected to earth ground. (These ground connections should have been made prior to shipping, but might have loosened or been disconnected during transit.)

Check DC grounding in the following order, starting at the top of the rack:


For an example of DC grounding, see Figure 3-28.



Figure 3-28: Access Server Shelf with DC Ground Connected


Step 2 If you need to ground any of the shelves, do so. See Figure 3-29.


Figure 3-29: Connecting a DC Access Server Shelf to Earth Ground


Step 3 Verify that all of the shelves in the Cisco AccessPath-TS3 Model 531 system have been connected to the DC busbar. (These connections should have been made prior to shipping, but might have loosened or been disconnected during transit.)

Check DC power connections to the busbar in the following order, starting at the top of the rack:


For an example of DC power connections, see Figure 3-30. For information on where each shelf should connect to the DC busbar, see Figure 3-34.



Figure 3-30: Shelf Power Connection to the DC Busbar


Step 4 If you need to connect any of the shelves to the DC busbar, do so.


Figure 3-31: Wiring the DC Busbar Connector to a Shelf's DC Power Supply



Figure 3-32: Connecting a Shelf to the DC Busbar



Figure 3-33:
Shelf Connected to the DC Busbar



Figure 3-34:
DC Busbar and Connector Labels


Step 5 Connect the main earthing wire to either set of double grounding studs using a 2-6 AWG copper stranded wire crimped to a double lug of the appropriate size. (These studs are located at the top and bottom of the rear of the system.)

 
Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.

Step 6 Remove the DC busbar inlet panel. See Figure 3-35.


Figure 3-35: Removing or Installing the DC Busbar Inlet Panel


Step 7 Connect DC power to the DC busbar. This will require 4 dedicated 45 A (-48 to -60 VDC) circuits per Cisco AccessPath-TS3 Model 531 system cabinet.

With the DC power source turned OFF, connect 2-6 AWG copper-stranded wire to the DC busbar using the provided double lugs and following these guidelines:



Figure 3-36: Connecting DC Power Feeds to the DC Busbar


Step 8 Reduce possible strain on the DC electrical connection by installing the strain relief kit at the top of the cabinet. See Figure 3-37.


Figure 3-37: Installing the DC Power Feed Strain Relief Kit


Step 9 Tighten the nuts that connect the DC power feeds to the inlet.

Step 10 Tighten the 5 screws on the strain relief kit so that they firmly grip the DC power feeds. (See Figure 3-37 and Figure 3-38.)


Figure 3-38: DC Power Feed Strain Relief Kit After Installation


Step 11 Replace the DC inlet panel. See Figure 3-35.

Step 12 Make sure that all of the shelves are turned OFF.

Step 13 Turn ON power at the DC power source.

 
Warning After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position.

Step 14 You may turn each of the shelves ON, one at a time.

Verify Power and Physical Connectivity

Follow these steps to verify power and physical connectivity for the Cisco AccessPath-TS3 Model 531 Integrated Access System:

Step 1 Verify that the fans are running on each of the shelves of the Cisco AccessPath-TS3 Model 531 system. If the fans are operational, then the power cords are operational, power is turned ON, and the fuses or circuit breakers are functioning.

Step 2 Verify connectivity. Be sure to wait 60 seconds from power-up for all devices to initialize.

Step 3 Check the Power OK LEDs on each of the following shelves. At initial startup, the OK LEDs should flash ON. After all devices have initialized, the LEDs should remain ON. This indicates that each shelf is functioning properly. Refer to Figure 3-39 through Figure 3-42 for the location of the OK LEDs on each shelf.


Figure 3-39: System Controller System LED



Figure 3-40: Access Server Shelf OK LED



Figure 3-41: Router Shelf I/O Power OK LED



Figure 3-42:
Switch Shelf Power OK LED


Step 4 Check the connection to the Cisco AccessPath-TS3 Model 531 system from the telco. All 3 LEDs for each of the T1 or E1 lines feeding into the Access Server Shelves should be OFF. In addition, the OK and ACT LEDs should be ON.

Step 5 Check the connections between the shelves in the Cisco AccessPath-TS3 Model 531 system.

Step 6 Check the 10BaseT connection between the Access Server Shelves and the Router Shelf or Shelves. Verify that the link status LED on the Access Server Shelves and the link status LED on the Router Shelf or Shelves are ON.

Step 7 Check the 100BaseT connection between the Access Server Shelves and the Switch Shelf. Verify that the link status LED on the Access Server Shelves is ON. Verify that the Link LED on the Switch Shelf is ON.

Step 8 Check the 100BaseTX connections between the Router Shelves and the Switch Shelf. Verify that the link status LED is ON at both ends of each cable. For interfaces with media-independent interface transceivers, the link status is on the transceiver.

Step 9 Check the connection with your network. This connection is device dependent but should have a link status on the port adapter or related transceiver that will indicate connectivity.

Verify or Configure the Software

The software configuration of the Cisco AccessPath-TS3 Model 531 system may have been done for you at the factory. Using the System Controller, you should verify the configuration or configure the system (depending on which is required for your Cisco AccessPath-TS3 Model 531 system) as follows:

Step 1 Gain access to the system. The System Controller provides command line interface (CLI) console management services for each of the Cisco AccessPath-TS3 Model 531 system shelves. These services are available either:

Step 2 Use Cisco IOS software or Cisco AccessPath Manager software to verify the software configuration or configure the Cisco AccessPath-TS3 Model 531 system.

Make a Local Connection to the Console Port

To connect a local terminal or a PC running terminal emulation software to the console port on the System Controller:

Step 1 Connect the terminal using an RJ-45 rollover cable and an RJ-45-to-DB-25 or RJ-45-to-DB-9 adapter. (See Figure 3-43.)

Step 2 Configure your terminal or terminal emulation software for 9600 baud, 8 data bits, no parity, and 1 stop bit.


Note Because hardware flow control is not possible on the console port, it is not recommended that modems be connected to the console port. Modems should always be connected to the auxiliary port, except under special circumstances. See the section "Disaster Recovery" in the chapter "ROM Monitor" of the Cisco 3640 Router Installation and Configuration Guide for more information.

Figure 3-43: Connecting the Console Terminal to the Console Port


Make a Remote Connection to the Auxiliary Port

Take the following steps to connect a modem to the auxiliary port on the System Controller:

Step 1 Connect the modem to the auxiliary port using an RJ-45 rollover cable with an RJ-45-to-DB-25 adapter. (See Figure 3-44.)

Step 2 Make sure that the modem and the auxiliary port on the System Controller are configured for the same transmission speed (38400 bps is typical; up to 115200 bps is supported) and hardware flow control with Data Carrier Detect (DCD) and Data Terminal Ready (DTR) operations.


Figure 3-44: Connecting a Modem to the Auxiliary Port


Verify or Configure the Software

Use Cisco IOS software or Cisco AccessPath Manager software to verify the software configuration of IP addresses and interfaces or, if necessary, configure the Cisco AccessPath-TS3 Model 531 system.


Note The preferred way to work with the Cisco AccessPath-TS3 Model 531 system is through Cisco AccessPath Manager software.

Refer to the following documents:

Connect to the T1 or E1 Network

This section describes procedures for connecting to the T1 or E1 network at your installation.

 
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.  
Warning The ISDN connection is regarded as a source of voltage that should be inaccessible to user contact. Do not attempt to tamper with or open any public telephone operator (PTO)-provided equipment or connection hardware. Any hardwired connection (other than by a nonremovable, connect-one-time-only plug) must be made only by PTO staff or suitably trained engineers.  
Warning Incorrect connection of this or connected equipment to a general purpose outlet could result in a hazardous situation.  
Warning This equipment is to be installed and maintained by service personnel only as defined by AS/NZS 3260 Clause 1.2.14.3 Service Personnel.  
Warning The telecommunications lines must be disconnected 1) before unplugging the main power connector and/or 2) while the housing is open.  
Warning The E1 interface card may only be installed in an ACA-permitted customer equipment or a Data Terminal Equipment (DTE) that is exempted from ACA's permit requirements. The customer equipment must only be housed in a cabinet that has screw-down lids to stop user access to overvoltages on the customer equipment. The customer equipment has circuitry that may have telecommunications network voltages on them.

Guidelines for Connecting to a T1 or E1 Network

You connect to a T1 or E1 network using patch panels, which either have RJ-48C connectors or posts for wire-wrap connections. The port mapping between the patch panel ports and the individual Access Server Shelves is the same for either wire-wrap or RJ-48C connections. (For more information on Access Server Shelf/patch panel port mapping, see "Patch Panel Cable Assembly and Pinout" in Appendix B, "Cabling Specifications.")

Connecting to the Patch Panel Using a Wire-Wrap Tool

To connect your T1 or E1 network to the patch panel using wire wrap connections:

Step 1 Unscrew and remove the metal cover that protects the wire-wrap posts. See Figure 3-45.


Figure 3-45: Removing the Metal Cover to Access the Patch Panel Wire-Wrap Posts


When you have removed the metal cover, your patch panel is ready for wire-wrap connections. See Figure 3-46.



Figure 3-46: Patch Panel Ready for Wire-Wrap Connections


Step 2 Use a wire-wrap tool to connect to the Receive Tip and Ring and the Transmit Tip and Ring connections for up to 28 connections per patch panel. Figure 3-47 illustrates the wiring locations within the patch panel.


Figure 3-47: Wire-Wrap Patch Panel Connections


Step 3 Replace the patch panel cover, routing the cables out the right side. (See Figure 3-48.)


Figure 3-48: Wire-Wrap Patch Panel with Cables Routed to the Right


Connecting to the Patch Panel Using RJ-48C Connectors

To connect your T1 or E1 network to the patch panel using RJ-48C connections:

Step 1 Plug in RJ-48C connectors for up to 28 connections per patch panel. Figure 3-49 illustrates the port locations within the patch panel.


Figure 3-49: Patch Panel Ready for RJ-48C Connections


For pinout information on the RJ-48C connectors, see Figure 3-50 and Table 3-4.



Figure 3-50: T1/E1 PRI Connector Pinouts




Table 3-4: Network-to-Patch Panel Cable Pinouts
RJ-48C 8 Pin1 Telco Side Description Patch Panel Description
1 Out ring In ring
2 Out tip In tip
4 In ring Out ring
5 In tip Out tip

1 Pins 3, 6, 7, and 8 are not used.

Step 2 When you have connected the T1/E1 cables, route them to the right and tie-wrap them so that they do not obstruct other shelves. (See Figure 3-51.)


Figure 3-51: Patch Panel with Cables Installed and Tie-Wrapped


Connect to the Network Backbone

Connect to your network backbone through port adapters on the Router Shelf:

Depending on whether you will be connecting to a LAN or a WAN, your backhaul port adapters should be as follows:

After installing the correct port adapters, be sure to configure them properly. Refer to the documentation that shipped with your port adapter.

This completes the hardware installation. If you have problems, see Appendix A, "Troubleshooting the Cisco AccessPath-TS3 Model 531 System."