Commissioning

Whether you are a corporate end user or a competitive Internet Service Provider (ISP), you have purchased a Cisco AS5800 network access server (NAS) to provide dial-up services that facilitate accessibility for remote or roaming personnel, or Internet admission to consumers for e-mail, e-commerce, and web browsing.

This chapter details Cisco AS5850 commissioning, or the formal functional setup of the equipment, through systematic software configurations, to initially prepare the system for data/voice call processing.

In our discussion, local-based authentication is used. After the Cisco AS5800 hardware is commissioned, PPP is configured and tested as described in Chapter 3 "AS5800 Operations" under "Configuring PPP and Authentication."


Note   A AAA RADIUS server is recommended. AAA Radius server discussions are available in Chapter 4 "AS5800 Administation" under "RADIUS Management" in the Cisco AS5800 Operations, Administration, Maintenance and Provisioning Guide.

Commissioning the Cisco AS5800 Hardware

This section describes configuring the Cisco AS5800 hardware to support terminal EXEC shell services and log in prompts for client modems, and includes the following:


Note   For a description of terminal EXEC shell services, refer to the "Task 7. Testing Asynchronous EXEC Shell Connections" section.

Understanding the Basic Hardware Architecture

To build an access network using the Cisco AS5800, it is necessary to understand:

Cisco 7206 Router Shelf and Cisco 5814 Dial Shelf

The Cisco AS5800 access server contains:

Figure 2-1 shows the Cisco AS5800 system architecture.


Figure 2-1: Cisco AS5800 System Architecture

Note   The Cisco IOS software uses a three-element notation to specify interface and port locations: shelf/slot/port.

Call-Processing Components

As shown in Figure 2-2, the following components process a call:


Figure 2-2:
Cisco AS5800 Call-Processing Components

One asynchronous PPP call requires:

One synchronous PPP call requires:


Tips Synchronous PPP calls require HDLC resources. Each T3 trunk card is limited to 256 HDLC resources. T1 trunk cards do not have HDLC resource limitations.

Task 1. Verifying Basic Setup

Verify that basic system components are functioning:

Analyzing the System Boot Dialog

To view the boot sequence through a terminal session, you must have a console connection to the access server before it powers up.


Caution Always power up the dial shelf before the router shelf. The DSC card checks the dial shelf's inventory, which requires extra time. After two minutes, power up the router shelf. The router shelf depends on the DSC card for the dial shelf's inventory report.

The following boot sequence occurs. Event numbers and comments are inserted in the example to describe the boot sequence.

System Bootstrap, Version 11.1(13)CA

Copyright (c) 1997 by cisco Systems, Inc.
C7200 processor with 131072 Kbytes of main memory
 
Self decompressing the image : 
##########################################################################################
################################################# [OK]
 
%PA-2-UNDEFPA: Undefined Port Adaptor type 106 in bay 2
%SYS-4-CONFIG_NEWER: Configurations from version 12.0 may not be correctly under
stood.
%OIR-3-SEATED: Insert/removal failed (slot 2), check card seating
%OIR-3-SEATED: Insert/removal failed (slot 2), check card 
seatingCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Read 7314384 bytes from file slot0:c5800-p4-mz.120-4.XL1.bin

Self decompressing the image : 
##########################################################################################
##########################################################################################
##########################################################################################
##########################################################################################
####################################################### [OK]
 
  Sometimes boot images do not support hardware cards. Sample error messages look like this:
    %PA-2-UNDEFPA: Undefined Port Adapter
    %OIR-3-SEATED: Insert/removal failed
     
    
  Ignore these messages and do not ignore error messages that appear after the Cisco IOS software image decompresses.
                  Restricted Rights Legend
     
    Use, duplication, or disclosure by the Government is
    subject to restrictions as set forth in subparagraph
    (c) of the Commercial Computer Software - Restricted
    Rights clause at FAR sec. 52.227-19 and subparagraph
    (c) (1) (ii) of the Rights in Technical Data and Computer
    Software clause at DFARS sec. 252.227-7013.
     
               cisco Systems, Inc.
               170 West Tasman Drive
               San Jose, California 95134-1706
     
    Cisco Internetwork Operating System Software IOS (tm) 5800 Software (C5800-P4-M), Version 12.0(4)XL1,
    TAC:Home:SW:IOS:Specials for info
    Copyright (c) 1986-1999 by cisco Systems, Inc.
    Compiled Thu 12-Aug-99 13:16 by ayeh
    Image text-base: 0x60008900, data-base: 0x611A6000
     
    cisco 7206 (NPE200) processor with 114688K/16384K bytes of memory.
    R5000 CPU at 200Mhz, Implementation 35, Rev 2.1, 512KB L2 Cache
    6 slot midplane, Version 1.3
     
    Last reset from power-on
    X.25 software, Version 3.0.0.
    Bridging software.
    SuperLAT software (copyright 1990 by Meridian Technology Corp).
    1 FastEthernet/IEEE 802.3 interface(s)
    1296 terminal line(s)
    1 Channelized T3 port(s)
     
    125K bytes of non-volatile configuration memory.
    4096K bytes of packet SRAM memory.
    20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
    4096K bytes of Flash internal SIMM (Sector size 256K).
     
    

Note   If a hardware card is not recognized, verify that you are running the optimum version of Cisco IOS software. Refer to the hardware-software compatibility matrix at:
http://cco-sj-1.cisco.com/cgi-bin/front.x/Support/HWSWmatrix/hwswmatrix.cgi

  The following system messsage and prompt appears.
    --- System Configuration Dialog ---
     
    Would you like to enter the initial configuration dialog? [yes/no]: no
     
    
    00:00:52: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 12 Succeeded
    00:00:53: %DSC_REDUNDANCY-3-BICLINK: Switching to DSC 12
    00:00:56: %DSC_REDUNDANCY-3-BICLINK: Link to active DSC up
    00:02:05: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 0 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 2 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 3 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 4 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 5 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 6 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 7 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 8 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 9 Succeeded
    00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 10 Succeeded
     
    Press RETURN to get started!
     
    5800>
     
    
  Depending on the number of cards in the dial shelf, there is a delay of 60 to 120 seconds before the "DSIP Hello" messages are displayed on your terminal session.
  After powering up the Cisco AS5800, enter the show environment command. Verify that there are no critical grounding, heating, or power problems. The following shows an operating environment.
    5800-NAS> show environment
    All measured values are normal
    5800-NAS> show environment all
    Power Supplies:
            Power supply 1 is empty.
            Power supply 2 is Zytek AC Power Supply. Unit is on.
     
    Temperature readings:
            chassis inlet    measured at 25C/77F 
            chassis outlet 1 measured at 27C/80F 
            chassis outlet 2 measured at 33C/91F 
            chassis outlet 3 measured at 41C/105F 
     
    Voltage readings:
            +3.45 V measured at +3.49 V 
            +5.15 V measured at +5.21 V 
            +12.15  measured at +12.34 V 
            -11.95  measured at -11.81 V 
     
    Envm stats saved 1 time(s) since reload
    5800-NAS>
    

Matching the Cisco IOS Software Images

The dial shelf and router shelf run separate Cisco IOS software images:

On the router shelf, check the Cisco IOS software image, uptime, and restart reason:

5800# show version

Cisco Internetwork Operating System Software IOS (tm) 5800 Software (C5800-P4-M), Version 
12.0(4)XL1

TAC:Home:SW:IOS:Specials for info
Copyright (c) 1986-1999 by cisco Systems, Inc.
Compiled Thu 12-Aug-99 13:16 by ayeh
Image text-base: 0x60008900, data-base: 0x611A6000
 
ROM: System Bootstrap, Version 11.1(13)CA, 
BOOTFLASH: 7200 Software (C7200-BOOT-M), Version 11.1(24)CC
 
Router uptime is 2 minutes

System returned to ROM by reload

System image file is "slot0:c5800-p4-mz.120-4.XL1.bin"

 
cisco 7206 (NPE200) processor with 114688K/16384K bytes of memory.

R5000 CPU at 200Mhz, Implementation 35, Rev 2.1, 512KB L2 Cache
6 slot midplane, Version 1.3
 
Last reset from power-on
X.25 software, Version 3.0.0.
Bridging software.
SuperLAT software (copyright 1990 by Meridian Technology Corp).
1 FastEthernet/IEEE 802.3 interface(s)
1296 terminal line(s)
1 Channelized T3 port(s)
125K bytes of non-volatile configuration memory.
4096K bytes of packet SRAM memory.
 
20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
4096K bytes of Flash internal SIMM (Sector size 256K).
Configuration register is 0x2102
 

Table 2-1 describes the significant output fields in the previous display:


Table 2-1: Show Version Command Field Descriptions
Field Description
5800 Software (C5800-P4-M), Version 12.0(4)XL1

Cisco IOS software version.

Router uptime is 2 minutes

Reports the router's uptime. Watch for unscheduled reloads.

System returned to ROM by reload

Describes why the access server last reloaded. If the field displays "power-on," a power interruption caused the reload.

System image file is 
"slot0:c5800-p4-mz.120-4.XL1.bin"

The Cisco 7206 router shelf booted from the external PCMCIA Flash card at slot 0.

The router shelf does not have internal Flash memory. If the PCMCIA Flash card is missing, the router shelf will not boot.

On the dial shelf, check the Cisco IOS software image, uptime, and restart reason. If you do not have a physical console connection to the dial shelf, enter the execute-on slot [12 | 13] show version command. The DSC can be in slot 12 or 13.

5800# execute-on slot 12 show version

 
DA-Slot12>
Cisco Internetwork Operating System Software IOS (tm) 5800 Software (C5800-DSC-M), Version 
12.0(4)XL1

TAC:Home:SW:IOS:Specials for info
Copyright (c) 1986-1999 by cisco Systems, Inc.
Compiled Thu 12-Aug-99 18:48 by ayeh
Image text-base: 0x600088F0, data-base: 0x60520000
 
ROM: System Bootstrap, Version 11.3(1)AA
ROM: 5800 Software (C5800-DSC-M), Version 11.3(9)AA2
 
DA-Slot12 uptime is 20 hours, 38 minutes

System returned to ROM by reload

System image file is "slot0:dsc-c5800-mz.120-4.XL1.bin"

 
cisco c5800 (R4K) processor with 24576K/8192K bytes of memory.
R4700 CPU at 150Mhz, Implementation 33, Rev 1.0, 512KB L2 Cache
Last reset from power-on

1 Ethernet/IEEE 802.3 interface(s)

2 Dial Shelf Interconnect(DSI) FE interface(s)

123K bytes of non-volatile configuration memory.
          
8192K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
4096K bytes of Flash internal SIMM (Sector size 256K).
Configuration register is 0x2102

Inspecting the Dial Shelf

Verify that feature cards are up (T3, T1, E3, E1, modem, or voice):

5800# show dial-shelf

Slot    Board     CPU       DRAM          I/O Memory   State         Elapsed
         Type     Util    Total (free)   Total (free)                Time
 0        CT3    0%/0%  21598976( 81%)  8388608( 41%)  Up            00:01:35
 2 Modem(DMM)  20%/20%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 3 Modem(DMM)    0%/0%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 4 Modem(DMM)  20%/20%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 5 Modem(DMM)  20%/20%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 6 Modem(DMM)  40%/40%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 7 Modem(DMM)  40%/40%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 8 Modem(DMM)  35%/35%  46764800( 86%) 16777216( 74%)  Up            00:01:35
 9 Modem(DMM)    0%/0%  46764800( 86%) 16777216( 74%)  Up            00:01:35
10 Modem(DMM)  20%/20%  46764800( 86%) 16777216( 74%)  Up            00:01:34
12        DSC    0%/0%  19097792( 79%)  8388608( 66%)  Up            00:02:49

Dial shelf set for auto boot
5800#
 

DSC Troubleshooting Tips

If the DSC card does not come up, perform the following troubleshooting steps. If the DSC card never comes up, the feature cards in the dial shelf cannot communicate with the router shelf.


Step 1   Look for LED lights on the DSC card. If the lights are off, try reseating the card.

Step 2   Verify that the DSI port adapter on the Cisco 7206 is inserted correctly.

Step 3   Verify that the cable between the DSI port adapter and the DSC card is connected correctly.

Step 4   From the Cisco 7206, verify that the DSI-Fast Ethernet interface and line protocol are up:

5800> show dsi

DSI-Fastethernet0/2/0 is up, line protocol is up 

  Hardware is DEC21140A, address is 0030.f2f5.1438 (bia 0030.f2f5.1438)
  MTU 0 bytes, BW 100000 Kbit, DLY 100 usec, 
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex, 100Mb/s, 100BaseTX/FX
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec

Note   The following example shows a dial shelf interconnection that changes state to up after the DSC card reloads. Loss of DSIP Keepalive messages indicate no communication between the router shelf and dial shelf. After DSIP Hello messages succeed, the Fast Ethernet DSI-Tx 0 and DSI-Rx 1 change their state to up. Until these interfaces are up, the router shelf and dial shelf cannot communicate. No debug commands are used to create these console messages; however, the terminal monitor command is required to watch them.

5800#
00:04:29: %DSIPPF-5-DS_KEEPALIVE_LOSS: DSIP Keepalive Loss from shelf 1 slot 12

00:05:12: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 12 Succeeded

00:05:18: %DIAL12-3-MSG: 
00:00:03: %LINK-3-UPDOWN: Interface DSI-Tx-FastEthernet0, changed state to up

00:00:03: %LINK-3-UPDOWN: Interface DSI-Rx-FastEthernet1, changed state to up

00:00:03: %LINK-3-UPDOWN: Interface Ethernet0, changed state to up
5800#

Note   In a production environment, verify that console logging is disabled. Enter the show logging command. If logging is enabled, the access server might intermittently freeze up as soon as the console port gets overloaded with log messages. Enter the no logging console command.

The following messages appear on the console-terminal session after the DSC card is physically removed from slot 12 and re-inserted. Approximately 120 seconds elapse before all these messages appear.

5800>
04:41:42: %DSC_REDUNDANCY-3-BICLINK: Link to active DSC down

04:42:13: %ISDN-6-LAYER2DOWN: Layer 2 for Interface Se1/0/0:4:23, TEI 0 changed to down
04:42:14: %DSC_REDUNDANCY-3-BICLINK: Link to active DSC up

04:42:36: %DSIPPF-5-DS_KEEPALIVE_LOSS: DSIP Keepalive Loss from shelf 1 slot 2

04:42:36: %DSIPPF-5-DS_KEEPALIVE_LOSS: DSIP Keepalive Loss from shelf 1 slot 3

04:42:46: %DSIPPF-5-DS_KEEPALIVE_LOSS: DSIP Keepalive Loss from shelf 1 slot 0

04:42:46: %DSIPPF-5-DS_KEEPALIVE_LOSS: DSIP Keepalive Loss from shelf 1 slot 12

04:42:53: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 12 Succeeded

04:44:59: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 0 Succeeded

04:45:02: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 2 Succeeded

04:45:03: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 3 Succeeded

5800>
 

The following boot sequence occurs in the previous example:

Step 5   If the DSC card is still down, the card might have an incorrect Cisco IOS software image, or the Flash card is missing (ROM monitor mode). Open a physical console connection to the DSC card, copy an image into boot Flash memory, and try re-initializing the system.

Step 6   For advanced troubleshooting measures after the DSC card is up, open a virtual-console session to the DSC card (DA-Slot12). To end the session, enter Ctrl C three times:

5800#dsip console slave 12

Trying Dial shelf slot 12 ...
Entering CONSOLE for slot 12
Type "^C^C^C" to end this session
 
 
DA-Slot12>
DA-Slot12#
DA-Slot12#
DA-Slot12#
Terminate NIP IO session? [confirm]
 
[Connection to Dial shelf slot 12 closed by local host]
5800#
 

Caution The router shelf provides the DSC card with the required configuration. Do not change the DSIP settings in the DSC card's configuration.

Feature Board Troubleshooting Tips

If the show dial-shelf command reports that feature cards are booting for extended periods of time, start debugging from the router shelf by using the following commands:

debug dsip transport

debug dsip trace

show dsi

 

Debug dsip transport shows the registered MAC address sent from each feature board.

Debug dsip trace displays detailed DSIP hello and keepalive messages.

Debug dsip boot shows if the router shelf is sending the boot image to the feature cards.

Understanding DSIP

The router shelf communicates with the dial shelf using:

For the DSIP command reference and other system management functions, refer to the document Dial and System Management Commands for the Cisco AS5800 at the following URL:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios113ed/113aa/113aa_2/
58cfeats/c5800uas.htm

To understand how DSIP functions, enter commands from the following bullet list:

5800-NAS# show dsi

DSI-Fastethernet0/2/0 is up, line protocol is up 

  Hardware is DEC21140A, address is 00d0.d342.4c38 (bia 00d0.d342.4c38)
  MTU 0 bytes, BW 100000 Kbit, DLY 100 usec,
        reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex, 100Mb/s, 100BaseTX/FX
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 0 bits/sec, 0 packets/sec
 
5800# show dsip transport 

DSIP transport statistics:

 IPC  : input msgs=4309, bytes=509139; output msgs=4308, bytes=291468

        total consumed ipc msgs=2133;  total freed ipc msgs = 2133

        transmit contexts in use = 13, free = 243, zombie = 0, invalid = 0

        ipc getmsg failures = 0, ipc timeouts=0

        core getbuffer failures=0, api getbuffer failures=0
        dsip test msgs rcvd = 0, sent = 0
 CNTL : input msgs=20927, bytes=738902; output msgs=20350, bytes=29816080
        getbuffer failures=0
 DATA : input msgs=1076, bytes=38736; output msgs=0, bytes=0
DSIP Private  Buffer Pool Hits  = 0

DSIP registered addresses:

 Shelf0 : Master: 00d0.d342.4c38, Status=local

 Shelf1 : Slot0 : 0090.bf52.4e00, Status=remote

 Shelf1 : Slot2 : 0090.bf52.4e10, Status=remote
 Shelf1 : Slot3 : 0090.bf52.4e18, Status=remote
 Shelf1 : Slot4 : 0090.bf52.4e20, Status=remote
 Shelf1 : Slot5 : 0090.bf52.4e28, Status=remote
 Shelf1 : Slot6 : 0090.bf52.4e30, Status=remote
 Shelf1 : Slot7 : 0090.bf52.4e38, Status=remote
 Shelf1 : Slot8 : 0090.bf52.4e40, Status=remote
 Shelf1 : Slot9 : 0090.bf52.4e48, Status=remote
 Shelf1 : Slot10: 0090.bf52.4e50, Status=remote
 Shelf1 : Slot12: 0090.bf52.4e60, Status=remote
5800#
 
5800# show dsip version

DSIP version information:
------------------------
Local DSIP major version =  5,   minor version = 2
All feature cards are running DSIP versions compatible with router shelf

Local clients registered versions:
------------------------------------
Client Name      Major Version   Minor Version
Console          5               2            
Clock            2               1            
Modem            0               0            
Logger           No version      No version   
TDM              No version      No version   
Trunk            No version      No version   
Async data       No version      No version   
VOICE            0               0            
Dial shelf       1               1            
Environment      No version      No version   
FILESYS          No version      No version   
DSC Red. UI      0               1            
Split DS         No version      No version   
DSIP Test        No version      No version   
 
Mismatched  remote client versions:

-----------------------------------
5800#

Note   This command also reports mismatched Cisco IOS software versions. No mismatches exist in this example.

Checking the Initial Running-Config

The Cisco IOS software creates an initial running configuration. To get familiar with the default settings, inspect the software configuration.


Step 1   Display the configuration on the Cisco 7206 router shelf:

5800# show running-config

Building configuration...
 
Current configuration:
!
version 12.0
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname Router
!
!
shelf-id 0 router-shelf
shelf-id 1 dial-shelf
!
!
!
resource-pool disable
!         
modem-pool Default
 pool-range 1/2/0-1/10/143
!
!
spe 1/2/0 1/10/11
 firmware ios-bundled default
modem recovery action none
ip subnet-zero
!
isdn voice-call-failure 0
!
!
controller T3 1/0/0
 cablelength 224
!
!
!
process-max-time 200
!
interface FastEthernet0/1/0
 no ip address
 no ip directed-broadcast
 shutdown 
!
interface Group-Async0
 no ip address
 no ip directed-broadcast
 group-range 1/2/00 1/10/143
!
ip classless
no ip http server
!
!
!
line con 0
 transport input none
line aux 0
line vty 0 4
line 1/2/00 1/10/143
 modem InOut
 no modem log rs232
!
end
 

Step 2   Without connecting to the DSC, display the configuration on the Cisco 5814 dial shelf:

5800# execute-on slot 12 show running-config 

 
DA-Slot12#
Building configuration...
 
Current configuration:
!
version 12.0
service config
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname DA-Slot12
!
!
ip subnet-zero
!
!
process-max-time 200
!
interface Ethernet0
 no ip address
 no ip directed-broadcast
 shutdown
!
no ip http server
ip classless
!
!
line con 0
 transport input none
line vty 0 4
!
end

Exploring the Cisco IOS File System

Get familiar with the file system and memory storage areas. The Cisco IOS File System provides a consolidated interface to:

Cisco IOS File System first appeared in Cisco IOS Releases 11.3 AA and 12.0. For more information about IFS, refer to the chapter Using the Cisco IOS File System in the Release 12.0 Configuration Fundamentals Configuration Guide at the following URL:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/12cgcr/fun_c/fcprt2/fcifs.htm

Figure 2-3 shows the memory locations inside the Cisco AS5800.


Figure 2-3: Cisco AS5800 Memory Locations

Table 2-2 describes the memory locations shown in Figure 2-3.


Table 2-2: Memory Location Descriptions
Component Description

CPU (NPE200)

Central processing unit.

Processor memory

The Cisco IOS software image is initially read out of Flash memory, decompressed, and loaded into processor memory (also known as main memory).

Routing tables, call control blocks, and other data structures are also stored here.

Packet I/O memory

Packets are temporarily stored in I/O memory.

slot0: flash:

slot1:

PCMCIA Flash memory cards in the router shelf. They store Cisco IOS software images, modem firmware/portware, and custom web pages.

bootflash:

Flash memory on the Cisco 7206's motherboard.

nvram:

Nonvolatile configuration memory.

dsc12-slot0:

dsc12-slot1:

PCMCIA Flash memory cards in the DSC card.

dsc12-bootflash:

Flash memory on DSC's card's motherboard.

dsc12-nvram:

Nonvolatile configuration memory in the DSC card.

To inspect the file system, enter commands from the following bullet list:

5800# show file systems

File Systems:
 
     Size(b)     Free(b)      Type  Flags  Prefixes
           -           -     flash     rw   disk0:
           -           -     flash     rw   disk1:
           -           -    opaque     rw   null:
           -           -    opaque     rw   system:
           -           -   network     rw   tftp:
      129016      128277     nvram     rw   nvram:

*   20578304    13263792     flash     rw   slot0: flash:

           -           -     flash     rw   slot1:

     3407872     1286636     flash     rw   bootflash:

           -           -    opaque     wo   lex:
           -           -   network     rw   rcp:
           -           -   network     rw   pram:
           -           -   network     rw   ftp:
     7995392     5825440     flash     rw   dsc12-slot0:

           -           -     flash     rw   dsc12-slot1:

     3407872     1575412     flash     rw   dsc12-bootflash:

      126968      126968     nvram     rw   dsc12-nvram:

5800#
 
5800# dir system:

Directory of system:/
 
  2  dr-x           0              <no date>  memory
  1  -rw-         787              <no date>  running-config
 
No space information available
5800#

Tips Remember to include the trailing colon (:) in the dir commands.

5800# pwd

slot0:
5800# dir

Directory of slot0:/
 
  1  -rw-     7314384   Sep 13 1999 20:03:41  c5800-p4-mz.120-4.XL1.bin
20578304 bytes total (13263792 bytes free)
5800#
5800# dir dsc12-slot0:

Directory of dsc12-slot0:/
 
  1  -rw-     2169824   Sep 13 1999 20:28:53  dsc-c5800-mz.120-4.XL1.bin
7995392 bytes total (5825440 bytes free)
5800#
 
5800# dir bootflash:

Directory of bootflash:/
 
  1  -rw-     2121108   Jan 01 2000 00:00:48  c7200-boot-mz.111-24.CC
 
3407872 bytes total (1286636 bytes free)
Router
5800# dir dsc12-bootflash:

Directory of dsc12-bootflash:/
 
  1  -rw-     2169824   Nov 18 1999 22:18:30  dsc-c5800-mz.120-4.XL1.bin
 
3407872 bytes total (1237920 bytes free)

Tips Keep a backup copy of the dial shelf's image in boot Flash. Someone may take PCMCIA Flash cards without notification. The dial shelf does not have its own connection to the IP backbone for image upgrade purposes.

  The squeeze command is required to remove deleted files:
    5800-NAS# pwd
    dsc12-bootflash:/
    5800-NAS# delete dsc-c5800-mz.113-9.AA2
    Delete filename [dsc-c5800-mz.113-9.AA2]? 
    Delete dsc12-bootflash:dsc-c5800-mz.113-9.AA2? [confirm]
    5800-NAS# squeeze dsc12-bootflash:
    All deleted files will be removed. Continue? [confirm]
    Squeeze operation may take a while. Continue? [confirm]
     
    DA-Slot12#
    All deleted files will be removed. Continue? [confirm]
    Squeeze operation may take a while. Continue? [confirm]
     
    Squeeze of bootflash complete
    Squeeze of dsc12-bootflash complete
    5800-NAS#
     
    
    5800# dir nvram:
    Directory of nvram:/
      1  -rw-         739              <no date>  startup-config
      2  ----          24              <no date>  private-config
      3  -rw-         739              <no date>  underlying-config
    129016 bytes total (128277 bytes free)
    5800#
     
    5800# dir dsc12-nvram:
    Directory of dsc12-nvram:/
      1  -rw-           0              <no date>  startup-config
      2  ----           0              <no date>  private-config
      3  -rw-           0              <no date>  underlying-config
    126968 bytes total (126968 bytes free)
    5800#
    

Investigating Memory Usage

Use the show memory summary command to:

Do the following to inspect and calculate memory usage:


Step 1   Display the memory status report. Note that the largest-memory block is close to the free-memory block, which is good.
There is no fragmentation.

5800-NAS# show memory summmary

                Head   Total(b)    Used(b)    Free(b)  Lowest(b) Largest(b)

 Processor  6164D4E0   94055200   42346480   51708720   50435436   51592056

       I/O   7000000   16777216    6433400   10343816   10343816   10343772
       PCI  4B000000    4194304     618584    3575720    3575720    3575676

Caution Do not enter the show memory summary command with the terminal length 0 command enabled. Otherwise, you will produce many screens of output which might interrupt your session.

Table 2-3 describes the significant fields in the previous display:


Table 2-3: Show Memory Summary Output Field Descriptions
Field Description

Processor

Processor memory. The Cisco IOS software image is initially read out of Flash memory, decompressed, and placed into main memory. Routing tables and call control blocks are also stored in main memory.

I/O

Packets are temporarily stored in I/O memory.

Head

Hexadecimal address of the head of the memory allocation chain.

Total(b)

Summary of used bytes plus free bytes.

Used(b)

Total number of bytes currently used for routing tables and call-processing components.

Free(b)

Total number of free bytes. The free memory size should be close to the largest block available.

Lowest(b)

Smallest amount of free memory since last boot.

Largest(b)

Size of largest available free block. Whenever the largest available block is equal to the free block, there is no fragmentation.

In the example, there is a small amount of fragmentation.

Step 2   Convert bytes to megabytes (MB):

Total memory (89.7 MB) = Used memory (40.4 MB) + free memory (49.3 MB)

Step 3   Perform some useful memory calculations:

Total Processor = total RAM - Cisco IOS software (use the show version command to get the MB assigned for all of Cisco IOS software + Processor)

cisco 7206 (NPE200) processor with 114688K/16384K bytes of memory.
 

114688 KB / (1024 KB / MB) = 112.0 MB

16384 KB = 16 MB

112 MB + 16 MB = 128 MB (what you purchased).


Note   112.0 MB - 89.7 MB = 22.3 MB. This means that 22.3 MB are not available for processor memory.

Inspecting CPU Utilization

High utilization causes network performance problems. For example, knowing when the router is running at over 50% utilization is critical. The router might start dropping packets if an unexpected traffic burst comes through or if OSPF gets recalculated. Fast switching reduces CPU utilization.

5800# show processes cpu

CPU utilization for five seconds: 20%/6%; one minute: 31%; five minutes: 19%

 PID  Runtime(ms)  Invoked  uSecs    5Sec   1Min   5Min TTY Process 
   1      144208   1526300     94   0.00%  0.00%  0.00%   0 Load Meter 
   2      118732  19749060      6   0.24%  0.12%  0.08%   0 OSPF Hello 
   3    42752544   2699659  15836   3.75%  0.87%  0.62%   0 Check heaps 
   4        7260     30062    241   0.00%  0.00%  0.00%   0 Pool Manager 
   5           0         2      0   0.00%  0.00%  0.00%   0 Timers 
   6        1472    494101      2   0.00%  0.00%  0.00%   0 Serial Background 
   7       49424   7631216      6   0.00%  0.00%  0.00%   0 EnvMon 
   8           0         1      0   0.00%  0.00%  0.00%   0 OIR Handler 
   9    13368616   3217631   4154   0.32%  0.57%  0.42%   0 ARP Input 
  10       18932    533419     35   0.00%  0.00%  0.00%   0 DDR Timers 
  11         116         4  29000   0.00%  0.00%  0.00%   0 Entity MIB API 
 

Look at the top line of the output. If you see high utilization numbers, for example, over 50%, inspect the columns 5Sec, 1Min, and 5Min. Find the process that uses the most CPU power. For an idle chassis, numbers larger than two percent indicate a problem. The CPU utilization is displayed at the top of the display.

Table 2-4 describes the significant output fields in the previous example:


Table 2-4: CPU Utilization Display Fields
Field Description
CPU utilization for five seconds: 2%/0%; 

The first % number is the CPU utilization for the last 5 seconds. The second % number is the percentage of CPU time spent at the packet-based interrupt level.

one minute: 1%; 

CPU utilization for the last minute.

five minutes: 14%

CPU utilization for the last 5 minutes.

Whenever memory cannot be allocated to a process request (a memory leak), a console error message appears:

    Sep 14 11:30:33.339 EDT: %SYS-2-MALLOCFAIL: Memory allocation of 19960
    bytes failed from 0x603D530C, pool Processor, alignment 0
     -Process= "Exec", ipl= 0, pid= 48
     -Traceback= 603D8610 603DAA70 603D5314 603D5AF0 60373054 60371474 603C33DC
    603C3538 603C4378 60371934 603586B8 60358A10 6037C12C 6037C1E4 60372E9C
    6037EDEC
     
    

To identify the problem, inspect the first few output lines of the show memory summary command and show processor memory command. At times, the Cisco IOS software causes memory leaks. Whenever this happens, the Cisco TAC:

Task 2. Configuring Cisco IOS Software Basics

Apply a basic-running configuration to the NAS:


Tips Periodically save the configuration by using the copy running-config startup-config command.

2.1 Configuring the Host Name, Enable Secret, and Time Stamps

Assign a host name to the NAS, specify an enable secret password, and turn on time stamps:


Step 1   Enter the following commands in global configuration mode:

hostname 5800-NAS

enable secret yourpasswordhere

service password-encryption

service timestamps debug datetime msec

service timestamps log datetime msec


Note   The enable password command is an obsolete command. Do not use it.

Step 2   Log in with the enable secret password. The show privilege command shows the current security privilege level.

5800-NAS# disable

5800-NAS>enable

Password:
5800-NAS# show privilege

Current privilege level is 15
5800-NAS#

2.2 Configuring Local AAA Security

Configure AAA to perform login authentication by using the local username database. The login keyword authenticates EXEC shell users. Additionally, configure PPP authentication to use the local database if the session was not already authenticated by login.

AAA is the Cisco IOS software security model used on all Cisco devices. AAA provides the primary framework through which you set up access control on the NAS.

In this basic discussion, the same authentication method is used on all interfaces. AAA is set up to use the local database configured on the NAS. This local database is created with the username configuration commands.


Step 1   Create a local login username database in global configuration mode. In this example, the administrator's username is admin. The remote client's login username is dude.

!

username admin password adminpasshere

username dude password dudepasshere

!

 

Caution This step also prevents you from getting locked out of the NAS. If you get locked out, you must reboot the device and perform password recovery.

Step 2   Configure local AAA security in global configuration mode. You must enter the aaa new-model command before the other two authentication commands.

!

aaa new-model

aaa authentication login default local

aaa authentication ppp default if-needed local

!

 

Table 2-5 describes the previous configuration fragment:


Table 2-5: Local AAA Commands
Command Purpose

aaa new-model

Initiates the AAA access control system. This command immediately locks down login and PPP authentication.

aaa authentication login default local

Configures AAA to perform login authentication by using the local username database. The login keyword authenticates EXEC shell users.

aaa authentication ppp default if-needed local

Configures PPP authentication to use the local database if the session was not already authenticated by login.

Step 3   Log in with your username and password:

5800-NAS# login

 
User Access Verification
 
Username:admin

Password:
 
5800-NAS#
 

A successful login means your local username works on any TTY or VTY line. Do not disconnect your session until you can log in.

2.3 Setting Up a Log In Banner

Create a login banner. However, do not tell users what device they are connecting to until after they log in. Providing device sensitive information can tempt unauthorized users to hack into the system.


Step 1   Create the banner:

5800-NAS(config)# banner login |

Enter TEXT message.  End with the character '|'.
This is a secured device. 
Unauthorized use is prohibited by law.
|
5800-NAS(config)#^Z

5800-NAS#
 

Step 2   Test the banner:

5800-NAS#
5800-NAS# login

 
This is a secured device. 
Unauthorized use is prohibited by law.
 
User Access Verification
 
Username: admin

Password: 
 
5800-NAS#

2.4 Configuring Basic IP

To commission a basic dial access service:


Step 1   Assign the IP addresses, and create an IP route to the default gateway:

!
interface Loopback0

 ip address 172.22.99.1 255.255.255.255

!
interface Loopback1

 ip address 172.22.90.1 255.255.255.0

!
interface FastEthernet0/1/0

 ip address 172.22.66.23 255.255.255.0

!
ip route 0.0.0.0 0.0.0.0 172.22.66.1

!
 

The loopback interfaces are used for the following reasons:

Step 2   Verify that the Fast Ethernet interface is up. Ping the default gateway.

5800-NAS# ping 172.22.66.1

 
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to 172.22.66.1, timeout is 2 seconds:
.!!!!
Success rate is 80 percent (4/5), round-trip min/avg/max = 1/1/1 ms
 
5800-NAS#
 

This step verifies that you have IP connectivity with another device on the subnet. If the ping succeeds to the default gateway, try pinging the DNS server in your backbone. Make sure the backbone is configured to get to the access server; otherwise, the ping will not work. Configure the backbone routers to support the routes to the networks you are using.


Note   An 80% ping-success rate is normal for the first time you ping an external device. The NAS does not yet have an address resolution protocol (ARP) entry for the external device. A 100% success rate is achieved the next time you ping the device.

Task 3. Enabling the T3/T1Controllers

Configure the settings for the T3/T1 controllers. They must match the telco's settings on the telephone switch. Mismatched settings cause problems; sometimes these problems are not detected for a long time.

Figure 2-4 shows the logical controller components inside a Cisco AS5800. It tells you that a T3 trunk card requires T1 and T3 controller configuration settings. In the figure, only the fourth controller is configured. There are a total of 28 T1 controllers to configure.


Figure 2-4: Matching Controller Settings


Step 1   Define the ISDN PRI switch type. In the example, the T1 trunks are not using channel associated signaling (CAS).

!

isdn switch-type primary-ni

!

 

There are two ways to define the switch type:


Note   For T1 CAS trunks, no ISDN switch type is configured.

Step 2   Configure the T3 controller. There are 28 T1 controllers in one T3. In this example, only the fourth controller is configured. The t1 4 controller command automatically creates the logical controllers controller t1 1/0/0:4. The number of logical T1 controllers should match the number of TI PRI lines coming into your T3.

!

controller T3 1/0/0

 framing m23

 cablelength 0

 t1 4 controller

!

 

Step 3   Configure the corresponding T1 controllers:

!

controller t1 1/0/0:4

 framing esf

 pri-group timeslots 1-24

!

 

After the controllers are correctly configured, the following cards and interfaces change state:

00:01:59: %CONTROLLER-5-UPDOWN: Controller T3 1/0/0, changed state to up

00:02:01: %CONTROLLER-5-UPDOWN: Controller T1 1/0/0:4, changed state to up

00:02:02: %DIAL12-3-MSG:
07:08:54: %DSCCLOCK-3-SWITCH3: Clock moving to NORMAL from HOLDOVER, selected clock is on 
slot 0 port 4 line 0
00:02:05: %ISDN-6-LAYER2DOWN: Layer 2 for Interface Se1/0/0:4:23, TEI 0 changedto down
00:02:21: %ISDN-6-LAYER2UP: Layer 2 for Interface Se1/0/0:4:23, TEI 0 changed to up

5800-NAS> 
 

Table 2-6 describes some of the T3 and T1-controller concepts that are applied in the previous steps.


Table 2-6: Controller Terms and Descriptions
Concept Description

Framing type

Defines the control bits and data bits.

For T3s, Cisco supports:

  • M23—M23 multiplexer framing (default)

  • C-bit—C-bit parity framing

For T1s, Cisco supports:

  • ESF—Extended super frame. Required for 64 KB operation on DS0s. ESF requires 2k-framing bits for synchronization. The remaining 6k is used for error detection, CRC, and data link monitoring. ESF is recommended for PRI configurations.

  • SF—Super frame. SF (D4) is used in channel bank robbed bit signalling (RBS) configurations. The in-band signaling occurs within the 6th and 12th frames. SF uses the framing bit for frame synchronization. SF is not recommended for PRI configurations.

Line code type

An encoding method used to allow synchronous data to be transmitted in a compatible format. Common line codes are RZ (return to zero), NRZ (non-return to zero), B8ZS, AMI, and HDB3.

  • AMI—Alternate mark inversion. Signal transitions are referenced by a binary 1 (mark). AMI is used on older T1 circuits. B8ZS is more reliable than AMI.

  • B8ZS—Most popular line-code scheme used in North America. To maintain clock synchronization, B8ZS replaces string 8 binary 0s with variations. B8ZS is more reliable than AMI, and it should be used with PRI configurations.

Clock source

Refers to both timing and synchronization of the T1 carrier. Timing is encoded within the transmitted data signal, and it ensures synchronization throughout the network.

Clocks are prioritized by slot number (slot 0 to slot 5). The highest priority clock is selected from the card in slot 0. If this clock fails, the highest priority clock from the card in slot 1 becomes the default clock, and so forth.

Timeslot assignment

Timeslots are assigned to channels. For T1 PRI scenarios, all 24 T1 timeslots are assigned as ISDN PRI channels. After timeslots are assigned by the pri-group command, D-channel serial interfaces are automatically created in the configuration file (for example S1/0/0:0:23, S1/0/0:1:23, and so on).

Step 4   Verify that the controllers are up and no alarms or errors are detected. Error counters are recorded over a 24-hour period in 15-minute intervals. In the display output, focus on the data in the current interval.

5800-NAS# show controller t3

T3 1/0/0 is up.

  Applique type is Channelized T3
  No alarms detected.

  FEAC code received: No code is being received
  Framing is M23, Line Code is B3ZS, Clock Source is Internal
  Data in current interval (201 seconds elapsed):

     0 Line Code Violations, 0 P-bit Coding Violation
     0 C-bit Coding Violation, 0 P-bit Err Secs
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
     0 Unavailable Secs, 0 Line Errored Secs
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
  Total Data (last 1 15 minute intervals):
     30664 Line Code Violations, 49191 P-bit Coding Violation,
     47967 C-bit Coding Violation, 0 P-bit Err Secs,
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
     2 Unavailable Secs, 0 Line Errored Secs,
     10 C-bit Errored Secs, 10 C-bit Severely Errored Secs
5800-NAS# 
5800-NAS# show control T1 1/0/0:4

T1 1/0/0:4 is up.

  Applique type is Channelized T1
  Cablelength is short
  No alarms detected.

  Framing is ESF, Line Code is AMI, Clock Source is Line.
  Data in current interval (240 seconds elapsed):

     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
  Data in Interval 1:
     0 Line Code Violations, 8 Path Code Violations
     11 Slip Secs, 26 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 26 Unavail Secs
  Total Data (last 1 15 minute intervals):
     0 Line Code Violations, 8 Path Code Violations,
     11 Slip Secs, 26 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 26 Unavail Secs
5800-NAS#
 

After each controller is correctly set up, clear the counters and look for ongoing line violations and errors. To do this, enter the clear controller command followed by the show controller command:

clear controller t3

show controller t3

clear controller t1 1/0/0:4 

show controller T1 1/0/0:4

 

In the display output, focus on the data in the current interval. Error counters stop increasing when the controller is configured correctly.


Tips The clear controller t1 command does not reset or bring down the controller. The T1 stays up. Only the counters are cleared.

From the reference point of the NAS, Table 2-7 provides a list of T1 alarm conditions and descriptions.


Table 2-7: Alarm Conditions
Alarm Description

CRC Errors

Occur only in ESF format when a CRC bit has an error.

Excessive CRC Error Indication (ECRCEI)

Reported in ESF format when 32 of any 33 consecutive CRCs are in error.

Out of Frame (OOF)

Occurs when the framing pattern for a T1 line has been lost, and data cannot be extracted. This is a red alarm. In SF and ESF formats, OOF occurs when any two of four consecutive frame-synchronization bits are in error.

Loss of Signal (LOS)

Occurs when 175 consecutive 0s are detected in the MC. This is a red alarm. The signal is recovered if the density of 1s reaches 12.5%. The recovery happens when four 1s are received within a 32-bit period.

Remote Frame Alarm (RHEA)

Indicates that an OOF framing pattern occurred at the remote end. This is a yellow alarm.

Alarm Indication Signal (AIS)

Indicates to the remote end a loss of the received signal. This is a blue alarm. AIS occurs when a stream of 1s is received.

Loop Back

Indicates that a remotely initiated loopback (from the network) is in progress.

Errored Seconds

Depending on the framing format, indicates OOF conditions, frame slip conditions, or error events.

For SF, errored seconds reports the number of seconds the frame was in the OOF or slip condition. For ESF, errored seconds reports error events in seconds.

Bursty Errored Seconds

Reports CRC error conditions in seconds (ESF format only).

Severely Errored Seconds

Reports error events or frame slip conditions in seconds.

For more information about controllers, see the section "Channelized E1 and Channelized T1 Setup Commands" at the following URL:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/12cgcr/dial_r/drprt1/index.htm

Step 5   Verify that individual serial D channels are created. B channels S1/0/0:4:0 through S1/0/0:4:22 are rotary members (dialers) of the signaling D channel S1/0/0:4:23.

5800-NAS# show ip interface brief | inc :23

Serial1/0/0:4:23           unassigned      YES NVRAM  up       up
          
5800-NAS#
 

Additionally, enter the show interface S1/0/0:4:23 command.

Task 4. Configuring the Serial Interfaces

Configure the serial D channels to route incoming voice calls from the PSTN to the integrated modems. The behavior of the B channels is controlled by the D channels' configuration instructions. The D channel is the signaling channel.

Table 2-8 describes the relationship between T1 controllers and serial interfaces.

  An ISDN switch type defined on the global level is automatically propagated to the serial D-channel interface level. However, a switch type defined on the serial-interface level overrides a switch type defined on the global level. Per interface switch-types are first introduced in Cisco IOS Release 11.3AA.


Table 2-8: Controller-to-Channel Relationships
T1 Controllers D Channels B Channels

Controller T1 1/0/0:0

Interface Serial 1/0/0:0:23

S1/0/0:0:0 through S1/0/0:0:22

Controller T1 1/0/0:1

Interface Serial 1/0/0:1:23

S1/0/0:1:0 through S1/0/0:1:22

Controller T1 1/0/0:2

Interface Serial 1/0/0:2:23

S1/0/0:2:0 through S1/0/0:2:22

Controller T1 1/0/0:3

Interface Serial 1/0/0:3:23

S1/0/0:3:0 through S1/0/0:3:22

Controller T1 1/0/0:4

Interface Serial 1/0/0:4:23

S1/0/0:4:0 through S1/0/0:4:22

...

...

...


Step 1   Apply the
isdn incoming-voice modem command to each D-channel serial interface. In this example, one interface is configured.

!

interface Serial1/0/0:4:23

 isdn incoming-voice modem

!

 

Step 2   Verify that ISDN is functioning properly, and the serial channels are up:

5800-NAS# show isdn status

Global ISDN Switchtype = primary-ni
ISDN Serial1/0/0:4:23 interface
        dsl 0, interface ISDN Switchtype = primary-ni
    Layer 1 Status:
        ACTIVE
    Layer 2 Status:
        TEI = 0, Ces = 1, SAPI = 0, State = MULTIPLE_FRAME_ESTABLISHED
    Layer 3 Status:
        0 Active Layer 3 Call(s)
    Activated dsl 0 CCBs = 0
    The Free Channel Mask:  0x807FFFFF
    Total Allocated ISDN CCBs = 0
 
5800-NAS# show isdn service

PRI Channel Statistics:
ISDN Se1/0/0:4:23, Channel [1-24]
  Configured Isdn Interface (dsl) 0
  Channel State (0=Idle 1=Propose 2=Busy 3=Reserved 4=Restart 5=Maint_Pend)
  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 
  Service State (0=Inservice 1=Maint 2=Outofservice)
  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 

5800-NAS# 
 

Step 3   Test the configuration by sending a plain old telephone service (POTS) call into the Cisco AS5800 network access server (NAS). If the modem answers (you hear modem squelch), the configuration works. See Figure 2-5.


Figure 2-5: Sending a POTs Telephone Call into a NAS

A different telephone number is associated with each end of the connection.


Note   Using the debug ISDN q931 command (with the logging console command enabled) displays incoming call information on the monitor.

Task 5. Configuring Modems and Lines

Modems and lines are configured after:

Each modem is mapped to a dedicated asynchronous line inside the NAS. After the modem inout command is applied to the lines, the NAS is ready to accept modem calls.

AAA security is applied to the lines by the aaa new-model command and aaa authentication login default local command. AAA performs login authentication by using the local username database. The login keyword authenticates EXEC shell users.


Note   The modem speed 115200 bps and hardware flow control are the defaults for integrated modems.


Step 1   Configure modem control
(DCD/DTR) for incoming and outgoing modem calls:

!

line 1/2/00 1/10/143

 modem InOut

!

 

Note   The no modem log rs232 command limits the size of the show modem log command's output.

Step 2   Understand the modem-numbering scheme for the Cisco AS5800. Modems use the shelf/slot/port notation.

5800-NAS# show modem 

 
  Codes:
  * - Modem has an active call
  T - Back-to-Back test in progress
  R - Modem is being Reset
  p - Download request is pending and modem cannot be used for taking calls
  D - Download in progress
  B - Modem is marked bad and cannot be used for taking calls
  b - Modem is either busied out or shut-down
  d - DSP software download is required for achieving K56flex connections
  ! - Upgrade request is pending
 
            Avg Hold     Inc calls     Out calls   Busied   Failed     No   Succ
    Mdm       Time      Succ   Fail   Succ   Fail   Out      Dial    Answer  Pct
    1/2/00  00:00:00       0      0      0      0       0        0       0    0%
    1/2/01  00:00:00       0      0      0      0       0        0       0    0%
    1/2/02  00:00:00       0      0      0      0       0        0       0    0%
    1/2/03  00:00:00       0      0      0      0       0        0       0    0%
    1/2/04  00:00:00       0      0      0      0       0        0       0    0%
 

Step 3   Choose a specific modem and inspect the modem-to-TTY line association. TTY lines are simulated EIA/TIA-232 ports. In this example, TTY 432 is associated with modem 1/2/00.

TTY line numbers map to specific slots. Each slot is hard coded with 144 TTY lines. In the example, the first modem card is in slot 2 (slot 0 and slot 1 do not contain modem cards).

5800-NAS# show modem 1/2/00

     Mdm  Typ     Status     Tx/Rx     G  Duration  RTS   CTS   DCD   DTR
     ---  ---     ------     -----     -  --------  ---   ---   ---   ---
   1/2/00 (n/a)   Idle        0/0      1  00:00:00  RTS   CTS   noDCD DTR  
 
Modem 1/2/00, Cisco MICA modem (Managed), Async1/2/00, TTY432

Firmware Rev: 2.6.2.0
Modem config: Incoming and Outgoing
Protocol: (n/a), Compression: (n/a)
Management config: Status polling
RX signals: 0 dBm
 
  Last clearing of "show modem" counters never
    0 incoming completes, 0 incoming failures
    0 outgoing completes, 0 outgoing failures
    0 failed dial attempts, 0 ring no answers, 0 busied outs
    0 no dial tones, 0 dial timeouts, 0 watchdog timeouts
    0 no carriers, 0 link failures, 0 resets, 0 recover oob
    0 recover modem, 0 current fail count
    0 protocol timeouts, 0 protocol errors, 0 lost events

Task 6. Enabling IP Basic Setup

Tune IP routing behavior and domain-name services for EXEC shell users:


Step 1   Optimize IP routing functions. Enter the following commands in global configuration mode:

ip subnet-zero

no ip source-route

ip classless

 

Table 2-9 describes the previous commands:


Table 2-9: IP Routing Commands
Command Purpose

ip subnet-zero

Specifies that 172.22.0.0 is a valid subnet.

no ip source-route

Tightens security by ensuring that IP-header packets cannot define their own paths through the access server.

ip classless

Turns off traditional IP network class distinctions in the router [Class-A, Class-B, Class-C].

Step 2   Enter domain-name service global configuration commands to support EXEC shell users:

ip domain-lookup

ip host aurora 172.22.100.9

ip domain-name the.doc

ip name-server 172.22.11.10

ip name-server 172.22.12.10

 

Table 2-10 describes the previous commands:


Table 2-10: Domain-Name Commands
Command Purpose

ip domain-lookup

Enables IP domain-name lookups.

ip host aurora 172.22.100.9

Creates a local name-to-address map. When the NAS is not entered in a DNS server, this map is useful.

ip domain-name the.doc

Tells the NAS how to qualify DNS look ups. In this example, the.doc is appended to the end of each name that is looked up.

ip name-server 172.22.11.10

ip name-server 172.22.12.10

Specifies the primary and secondary name servers. They are used for mapping names to IP addresses.

Task 7. Testing Asynchronous EXEC Shell Connections

This task verifies that the following components are working:

The Cisco IOS software provides a command-line interface (CLI) called the EXEC.

The EXEC:

During this task, some administrators try to make complex services function such as PPP-based Web browsing. Do not jump ahead. Many other elements still need to be configured (for example, PPP and IPCP). The asynchronous-shell test ensures that the EXEC's login prompt can be accessed by a client modem. Taking a layered approach to building a network isolates problems and saves time.


Note   The Cisco AS5800 is designed to process PPP sessions. To support high ratios of EXEC-shell users or V.120 users, work with your support team.


Step 1   Locate a client PC, client modem, and analog line. From the client PC, open a terminal emulation program (such as Hyper Terminal, not Dial-Up Networking) and connect to the client modem. The following figure shows the network environment for this test.


Figure 2-6: Test Environment

Step 2   From a terminal-emulation program, test the EIA/TIA-232 connection to the client modem. Enter the at command. The modem sends an OK return message.

at

OK
 

Step 3   Dial the PRI telephone number assigned to the NAS (in this example, 5551234). After the modem successfully connects, a connect message appears.

atdt5551234

CONNECT 28800 V42bis

Tips Many modems support the a/ command, which recalls the last AT command. The ath command hangs up a modem call. The atdl command dials the last telephone number.

Step 4   Log into the EXEC session:

This is a secured device. 
Unauthorized use is prohibited by law.
 
User Access Verification
 
Username: dude

Password:
 
5800-NAS>
 

Step 5   Determine upon which line the call landed. The following example shows that TTY line 436 accepted the call. The call has been up and active for 20 seconds.

5800-NAS# show caller

                                                Active    Idle
  Line         User               Service       Time      Time
  con 0        admin              TTY           00:13:43  00:00:00 
  tty 436      dude               TTY           00:00:20  00:00:08  

 
5800-NAS# show caller user dude

 
  User: dude, line tty 436, service TTY
        Active time 00:00:34, Idle time 00:00:09
  Timeouts:            Absolute  Idle      Idle
                                 Session   Exec
      Limits:          -         -         00:10:00  
      Disconnect in:   -         -         00:09:50  
  TTY: Line 1/2/04

  DS0: (slot/unit/channel)=0/4/2

  Status: Ready, Active, No Exit Banner
  Capabilities: Hardware Flowcontrol In, Hardware Flowcontrol Out
                Modem Callout, Modem RI is CD
  Modem State: Ready
 
5800-NAS#

Note   The show caller command is added to Cisco IOS Release 11.3 AA and 12.0 T. If your software release does not support this command, use the show user command.

Step 6   Test the IP functionality to support shell sessions. From the NAS, Telnet to another device in your network.

5800-NAS> telnet 172.22.66.26

Trying 172.22.66.26 ... Open
 
User Access Verification
 
Username: admin

Password: 
 
5800-NAS>
5800-NAS> telnet aurora

Translating "aurora"...domain server (172.22.11.10) [OK]
Trying aurora.cisco.com (172.22.2.2)... Open
 
SunOS 5.6
 
login: dude

Password:
Last login: Wed Oct  6 08:57:46 from dhcp-aus-163-236
Sun Microsystems Inc.   SunOS 5.6       Generic August 1997
aurora% 

Task 8. Confirming the Final Running-Config

After completing the tasks in this section, the final running configuration looks like this:

5800-NAS# show running-config

 
Building configuration...
 
Current configuration:
!
version 12.0
service timestamps debug datetime msec
service timestamps log datetime msec
service password-encryption
!
hostname 5800-NAS
!
aaa new-model
aaa authentication login default local
aaa authentication ppp default if-needed local
enable secret 5 $1$gq.d$nZwr.ElnV/O0nE9U.wZ3D/
!
username admin password 7 105B1D1A0A12
username dude password 7 111C0D061817
!
!
!
!
shelf-id 0 router-shelf
shelf-id 1 dial-shelf
!
!
!
resource-pool disable
!
modem-pool Default
 pool-range 1/2/0-1/10/143
!
!
spe 1/2/0 1/10/11
 firmware ios-bundled default
modem recovery action none
ip subnet-zero
no ip source-route
ip host aurora 172.22.100.9
ip domain-name the.doc
ip name-server 172.22.11.10
ip name-server 172.22.12.11
!
isdn switch-type primary-ni
isdn voice-call-failure 0
!         
!
controller T3 1/0/0
 framing m23
 cablelength 0
 t1 4 controller
!
controller T1 1/0/0:4
 framing esf
 pri-group timeslots 1-24
!
!
voice-port 1/0/0:4:D
!
!
process-max-time 200
!
interface Loopback0
 ip address 172.22.99.1 255.255.255.255
 no ip directed-broadcast
!
interface Loopback1
 ip address 172.22.90.1 255.255.255.0
 no ip directed-broadcast
!
interface FastEthernet0/1/0
 ip address 172.22.66.23 255.255.255.0
 no ip directed-broadcast
!
interface Serial1/0/0:4:23
 no ip address
 no ip directed-broadcast
 isdn switch-type primary-ni
 isdn incoming-voice modem
 no cdp enable
!
interface Group-Async0
 no ip address
 no ip directed-broadcast
 group-range 1/2/00 1/10/143
!
ip classless
ip route 0.0.0.0 0.0.0.0 172.22.66.1
no ip http server
!
!         
banner login ^C
This is a secured device. 
Unauthorized use is prohibited by law.
^C
!
line con 0
 transport input none
line aux 0
line vty 0 4
line 1/2/00 1/10/143
 modem InOut
 no modem log rs232
!
end