This appendix describes the T1 and E1 cables available for the AS5800 Universal Access Server and provides pinout information for the CT1 and CE1 trunk card.
The CT1 trunk card receives and transmits 1.544-Mbps signals through 100-ohm cable, using common RJ-45 connectors. Use a straight-through RJ-45-to-RJ-45 cable to connect the T1 lines to an RJ-45 receptacle.
The CE1 trunk card receives and transmits 2.048-Mbps CE1 signals through either 120-ohm or 75-ohm coaxial cable. All CE1 interface cables use common RJ-45 connectors on the dial shelf end.
The receive impedance is software configurable and may be configured as 75 ohms, 100 ohms or 120 ohms. The T1 default value is set at 100 ohms. The E1 default value is set at 120 ohms. Use the command line termination {75-ohm | 120-ohm} in controller configuration mode to configure the receive impedance.
For a complete description of the line termination command, refer to the Cisco AS5800 Universal Access Server Software Installation and Configuration Guide.
Table A-1 lists the CT1 and CE1 port pinout.
| Pin1 | Signal |
|---|---|
1 | Receive tip |
2 | Receive ring |
3 | Jumpered ground |
4 | Transmit tip |
5 | Transmit ring |
6 | Jumpered ground |
7 | not used |
8 | not used |
| 1Any pins not described in the table are not connected. |
| Warning The ports labeled "Network Clock," "10BaseT," "Dial Shelf Interconnect," "Console," and "Alarms" are safety extra-low voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Because the E1/T1 circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the telephone network voltage (TNV) circuits. |
Interface cables for connecting the CT1 card ports are available from Cisco Systems; these cables and their product numbers are listed in Table A-2:
| Cable Description | Product Number |
|---|---|
RJ-45 to Bare, 100-ohm | CAB-T1-RJ45BARE |
|
|
Figure A-1 shows the CT1 interface cable, and Table A-3 lists the pinouts.

| RJ-45 Pin | Signal | Description | Direction | Bare |
|---|---|---|---|---|
Shield | Ground | Braid |
|
|
J1-1 | RX Tip | Twisted Pair #1 | <--- | WIRE-1 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | WIRE-2 |
J1-3 | RX Shield |
|
|
|
J1-4 | TX Tip | Twisted Pair #2 | ---> | WIRE-3 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | WIRE-4 |
J1-6 | TX Shield |
|
|
|
Interface cables for connecting the CE1 card ports are available from Cisco Systems; these cables and their product numbers are listed in Table A-4.
| Cable Description | Product Number |
|---|---|
RJ-45 to RJ-45, 120-ohm | CAB-E1-RJ45RJ45 |
RJ-45 to DB-15, 120-ohm | CAB-E1-RJ45DB15 |
RJ-45 to DB-15 null, 120-ohm | CAB-E1-RJ45DB15N |
RJ-45 to BNC, 75-ohm | CAB-E1-RJ45BNC |
RJ-45 to Twinax, 75-ohm | CAB-E1-RJ45TWIN |
RJ-45 to RJ-45 TE, 120-ohm | CAB-E1-RJ45TE |
RJ-45 to RJ-45 NT, 120-ohm | CAB-E1-RJ45NT |
RJ-45 to bare | CAB-T1-RJ45BARE |
The following figures and tables illustrate and describe the pinouts for each CE1 interface cable.

| RJ-45 Pin | Signal | Description | Direction | RJ-45 T1 Pin |
|---|---|---|---|---|
Shield | Ground | Shell/Braid |
| Shield |
J1-1 | RX Tip | Twisted Pair #1 | <--- | J2-1 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | J2-2 |
J1-3 | RX Shield |
|
|
|
J1-4 | TX Tip | Twisted Pair #2 | ---> | J2-4 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | J2-5 |
J1-6 | TX Shield |
|
|
|

| RJ-45 Pin | Signal | Description | Direction | DB-15 Pin |
|---|---|---|---|---|
Shield | Ground | Shell/Braid |
| Shell |
J1-1 | RX Tip | Twisted Pair #1 | <--- | J2-3 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | J2-11 |
J1-3 | RX Shield | Twisted Pair #3 |
| J2-4 |
J1-4 | TX Tip | Twisted Pair #2 | ---> | J2-1 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | J2-9 |
J1-6 | TX Shield | Twisted Pair #4 |
| J2-2 |
| RJ-45 Pin | Signal | Description | Direction | DB-15 Pin |
|---|---|---|---|---|
Shield | Ground | Shell/Braid |
| Shell |
J1-1 | RX Tip | Twisted Pair #1 | <--- | J2-1 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | J2-9 |
J1-3 | RX Shield | Twisted Pair #3 |
| J2-2 |
J1-4 | TX Tip | Twisted Pair #2 | ---> | J2-3 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | J2-11 |
J1-6 | TX Shield | Twisted Pair #4 |
| J2-4 |

| RJ-45 Pin | Signal | Description | Direction | BNC Pin |
|---|---|---|---|---|
Shield | Ground | Shell |
| RX, TX Shields |
J1-1 | RX Tip | Twisted Pair #1 | <--- | RX-Tip |
J1-2 | RX Ring | Twisted Pair #1 | <--- | RX-Shield |
J1-3 | RX Shield | Twisted Pair #3 |
| RX-Shield |
J1-4 | TX Tip | Twisted Pair #2 | ---> | TX-Tip |
J1-5 | TX Ring | Twisted Pair #2 | ---> | TX-Shield |
J1-6 | TX Shield | Twisted Pair #4 |
| TX-Shield |

| RJ-45 Pin | Signal | Description | Direction | Twinax Pin |
|---|---|---|---|---|
Shield | Ground | Shell |
| RX, TX Shields |
J1-1 | RX Tip | Twisted Pair #1 | <--- | RX-1 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | RX-2 |
J1-3 | RX Shield | Twisted Pair #3 |
| RX Shield |
J1-4 | TX Tip | Twisted Pair #2 | ---> | TX-1 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | TX-2 |
J1-6 | TX Shield | Twisted Pair #4 |
| TX Shield |

| RJ-45 Pin | Signal | Description | Direction | RJ-45 TE Pin |
|---|---|---|---|---|
Shield | Ground | Shell/Braid |
| Shield |
J1-1 | RX Tip | Twisted Pair #1 | <--- | J2-1 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | J2-2 |
J1-3 | RX Shield | Twisted Pair #3 |
| J2-3 |
J1-4 | TX Tip | Twisted Pair #2 | ---> | J2-4 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | J2-5 |
J1-6 | TX Shield | Twisted Pair #4 |
| J2-6 |
| RJ-45 Pin | Signal | Description | Direction | Signal | RJ-45 NT Pin |
|---|---|---|---|---|---|
Shield | Ground | Shell/Braid |
| Ground | Shield |
J1-1 | RX Tip | Twisted Pair #1 | <--- | TX Tip | J2-4 |
J1-2 | RX Ring | Twisted Pair #1 | <--- | TX Ring | J2-5 |
J1-3 | RX Shield | Twisted Pair #3 |
| TX Shield | J2-6 |
J1-4 | TX Tip | Twisted Pair #2 | ---> | RX Tip | J2-1 |
J1-5 | TX Ring | Twisted Pair #2 | ---> | RX Ring | J2-2 |
J1-6 | TX Shield | Twisted Pair #4 |
| RX Shield | J2-3 |
| Warning The ports labeled "Network Clock," "10BaseT," "Dial Shelf Interconnect," "Console," and "Alarms" are safety extra-low voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Because the E1/T1 circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the telephone network voltage (TNV) circuits. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Jul 6 14:17:52 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.