This chapter contains an alphabetical listing of the Cisco 6510 Service Selection Gateway commands. The description of each command includes a brief description of its use, command syntax, and usage guidelines.
Commands can be entered directly at the command-line prompt. All commands are not case sensitive.
Most Cisco 6510 commands support pattern matching. For example, if you entered config set fei, you would be prompted to configure the following parameters:
Carriage Return to Skip; '.' to quit; 'c' to clear --> FEI0_InetAddr: <10.10.10.1>: FEI0_Mask: <255.255.0.0>: FEI0_InetGateway: <>: FEI0_InetName: <Hosts>: FEI1_InetAddr: <171.69.255.54>: FEI1_Mask: <255.255.255.240>: FEI1_InetGateway: <171.69.255.49>: FEI1_InetName: <UCPcard>: FEI2_InetAddr: <171.69.255.21>: FEI2_Mask: <255.255.255.248>: FEI2_InetGateway: <171.69.255.22>: FEI2_InetName: <ISPcard>:
| To configure all parameters for a first-time configuration, enter config set without any parameters. |
The following table lists configuration commands by Cisco 6510 features:
| Feature | Command |
|---|---|
Configuration management
|
config set config show reboot config save |
Help
|
help command ? |
IP address
|
ifconfig |
Security
|
secret dashboardpassword secret aaapassword |
Logging
|
logtarget |
Debugging
|
debug |
System upgrade
|
burnimg |
The following pages contain sections on each of the Cisco 6510 commands.
This command sets accounting timeouts and retries.
accountparam [-t timeout] [-r retries]| timeout | Sets how long the Cisco 6510 will wait before resending an accounting packet to a RADIUS accounting server (default: 10). |
| retries | Sets the number of times the Cisco 6510 will resend an accounting packet to a RADIUS accounting server (default: 5). |
Use the accountparam command to set accounting timeouts and retries. Entering accountparam by itself displays the current settings.
Parameters set with the accountparam command do not take effect until the Cisco 6510 is rebooted.
SSG > accountparam -t 20 -r 10
AccountingParam: <Timeout: 20 Seconds>
<Retries: 10 times>
This command writes an image of the Cisco 6510 software from disk to Flash memory. When the unit is rebooted, the system will display the new version of the software.
burnimg -f file [-t bios | img]| file | Filename of the configuration file to read. This file must reside in the /fd0/ directory |
| bios | With the -t parameter, specifies writing the configuration to the BIOS chip. |
| img | With the -t parameter, specifies writing the configuration to an image maintained in the systems Flash memory (default). |
Use the burnimg command to update the Cisco 6510 software and write the new version to the system's Flash memory from disk.
To use the default target for the image file, enter burnimg -f /fd0/file_name, where file_name is the filename of the image file and fd0 is the location of the floppy disk.
When you issue the burnimg command, specify the filename and location of the update file with the -f parameter.
Next, specify where to write the software image. To update the Cisco 6510's BIOS chip with the new software image, specify bios with the -t parameter. To update the auxiliary chips on the Cisco 6510 with the new software image, specify img with the -t command.
SSG > burnimg -f /fd0/csco6510 -t img Reading file /fd0/csco6510 ... Reading file is done. Burning image /fd0/csco6510 to flash memory ... Burning Image is Done!
This command clears configuration settings for the selected parameter.
config clear config_parm| config_parm | Cisco 6510 configuration parameter name. |
Use the config clear command to clear settings for a Cisco 6510 configuration parameter.
SSG > config clear AccountingIP2 Cleared AccountingIP2. SSG > config clear inet Cleared FEI0_InetAddr. Cleared FEI0_InetGateway. Cleared FEI0_InetName. Cleared FEI1_InetAddr. Cleared FEI1_InetGateway. Cleared FEI1_InetName. Cleared FEI2_InetAddr. Cleared FEI2_InetGateway. Cleared FEI2_InetName.
This command writes the current Cisco 6510 configuration settings to Flash memory.
config saveUse the config save command to set a Cisco 6510 configuration parameter.
SSG > config save Save Done.
This command sets a Cisco 6510 configuration parameter.
config set config_parm parm_values| config_parm | Cisco 6510 configuration parameter name. |
| parm_value | Parameter values to set. |
Use the config set command to set a Cisco 6510 configuration parameter. The syntax used with the parm_value varies depending on which parameter is set.
SSG > config set AccountingRemotePort 1848
This command sets the Cisco 6510's network settings to their default values.
config setdefaultUse this command to set the Cisco 6510's network configuration settings to their default values. This command is useful if you have changed the configuration and need to reset it to default settings.
The following table indicates the default configuration settings for the Cisco 6510.
| Parameter | Default Setting |
|---|---|
| AAAIP1 | 0.0.0.0 |
| AAAIP2 | 0.0.0.0 |
| AAAPassword | secret |
| AccountingIP1 | 0.0.0.0 |
| AccountingIP2 | 0.0.0.0 |
| ACCOUNTINGRemotePort | 1646 |
| ACCTRetryCount | 5 |
| ACCTTimeout | 10 |
| ARPRetryCount | 1 |
| ARPTimeOut | 1000 |
| ACCOUNTINGRemotePort | 1646 |
| DashBoardPassword | secret |
| DebugACCTHandler | 0 |
| DebugACCTLevel | 0 |
| DebugDHCPHandler | 0 |
| DebugDHCPLevel | 0 |
| DebugDNSHandler | 0 |
| DebugDNSLevel | 0 |
| DebugFOVERHandler | 0 |
| DebugFOVERLevel | 0 |
| DebugL2FHandler | 0 |
| DebugL2FLevel | 0 |
| DebugNATHandler | 0 |
| DebugNATLevel | 0 |
| DebugPPPHandler | 0 |
| DebugPPPLevel | 0 |
| DebugRADIUSHandler | 0 |
| DebugRADIUSLevel | 0 |
| DebugSystem | 0 |
| DebugSystemLevel | 0 |
| DefaultServerIP | 0.0.0.0 |
| DHCPIP | 0.0.0.0 |
| DHCPRemotePort | 67 |
| DNSRemotePort | 53 |
| FailoverActiveIP0 | 0.0.0.0 |
| FailoverActiveIP1 | 0.0.0.0 |
| FailoverActiveIP2 | 0.0.0.0 |
| FailoverActiveMac0 | |
| FailoverActiveMac1 | |
| FailoverActiveMac2 | |
| FailOverActiveState | 1 |
| FailoverEnable | 0 |
| FailoverStandbyIP0 | 0.0.0.0 |
| FailoverStandbyIP1 | 0.0.0.0 |
| FailoverStandbyIP2 | 0.0.0.0 |
| FailoverStandbyMac0 | |
| FailoverStandbyMac1 | |
| FailoverStandbyMac2 | |
| FEI0_InetAddr | |
| FEI0_InetGateway | |
| FEI0_InetName | |
| FEI0_Mask | 0.0.0.0 |
| FEI1_InetAddr | |
| FEI1_InetGateway | |
| FEI1_InetName | |
| FEI1_Mask | 0.0.0.0 |
| FEI2_InetAddr | |
| FEI2_InetGateway | |
| FEI2_InetName | |
| FEI2_Mask | 0.0.0.0 |
| L2FRemotePort | 1701 |
| LogFacility | 0 |
| LogTarget0 | 0 |
| LogTarget1 | 0 |
| LogTarget2 | 0 |
| LogTarget3 | 0 |
| LogTarget4 | 0 |
| MachineName | ssg |
| NATFTPCleanupInternal | 300 |
| NATFTPConnTimeout | 14400 |
| NATFTPFinConnTimeOut | 1 |
| NATFTPCTaskDelay | 15 |
| RADIUSRemotePort | 1645 |
| ServicePassword | secret |
SSG > config setDefault
This command displays the current setting for a specified configuration parameter.
config show [config_parm]| config_parm | Configuration parameter whose setting you want to show.
This parameter supports pattern matching. |
SSG >config show AAAIPAAAIP1: <0.0.0.0> AAAIP2: <0.0.0.0> SSG >config show PasswordDashboardPassword: <secret> AAAPassword: <secret> ServicePassword: <secret>
This command enables or disables debugging for a specified debug handler at a specified level.
debug {enable | disable} [-h handler] [-l level]| handler | You can enable or disable the following debug handlers:
system--System debug handler dhcp--Dynamic Host Configuration Protocol (DHCP) handler dns--Domain Name System (DNS) handler l2f--Layer 2 Forwarding (L2F) handler radius--Remote Access Dial-In User Service (RADIUS) handler accounting--Accounting protocol handler nat--Network address translation handler failover--Failover handler PPP--Point-to-Point Protocol handler |
| level | You can set the following debug levels:
error--Display error messages info--Display informational messages verbose--Display the long form of messages packet--Output the contents of each packet that is received and transmitted all--Display error, informational, and packet messages, in verbose form |
Use the debug command to enable or disable debugging for a specific debug handler. To enable a debug handler, enter debug enable followed by -h and the name of the handler to enable, -l, and the level of debugging. To disable a debug handler, enter debug disable followed by -h and the name of the handler to disable. If you are disabling a debug handler, you do not need to specify a debug level.
To disable all debugging levels without changing setting levels, enter debug disable. To restore these levels to their previous settings, enter debug enable.
When the handler is enabled, debug messages are output to the device(s) specified by the logtarget command. This can be the terminal device to which the Cisco 6510 is connected or one or more syslog files.
SSG > debug enable -h dhcp -l error Debug DHCP: Enabled [Active Level: ERROR] SSG > debug enable -h l2f -l all Debug L2F: Enabled [Active Level: ERROR INFO VERBOSE PACKET] SSG > debug disable -h radius Debug RADIUS: Disabled [Active Level: ERROR ] SSG > debug disable Debug DHCP: Disabled [Active Level: ERROR ] Debug DNS: Disabled [Active Level: ERROR ] Debug L2F: Disabled [Active Level: ERROR ] Debug PPP: Disabled [Active Level: ERROR ] Debug RADIUS: Disabled [Active Level: ERROR ] Debug ACCOUNTING: Disabled [Active Level: ERROR INFO VERBOSE PACKET ] Debug NAT: Disabled [Active Level: ERROR ] Debug FAILOVER: Disabled [Active Level: ERROR ] Debug SYSTEM: Disabled [Active Level: ERROR ]
Timesaver
| To quickly specify all debug levels for a debug handler, use a numeric value between 0 and 15. |
To determine the numeric value, use the following table. The value "1" indicates the debug level is enabled and "0" indicates the debug level is disabled.
No. | Packet | Verbose | Info | Error |
|---|---|---|---|---|
| 0 | 0 | 0 | 0 | 0 |
| 1 | 0 | 0 | 0 | 1 |
| 2 | 0 | 0 | 1 | 0 |
| 3 | 0 | 0 | 1 | 1 |
| 4 | 0 | 1 | 0 | 0 |
| 5 | 0 | 1 | 0 | 1 |
| 6 | 0 | 1 | 1 | 0 |
| 7 | 0 | 1 | 1 | 1 |
| 8 | 1 | 0 | 0 | 0 |
| 9 | 1 | 0 | 0 | 1 |
| 10 | 1 | 0 | 1 | 0 |
| 11 | 1 | 0 | 1 | 1 |
| 12 | 1 | 1 | 0 | 0 |
| 13 | 1 | 1 | 0 | 1 |
| 14 | 1 | 1 | 1 | 0 |
| 15 | 1 | 1 | 1 | 1 |
To enable error-level debugging for all handlers, enter the following:
SSG > config set level Carriage Return to Skip; '.' to quit; 'c' to clear --> DebugDHCPLevel: <7>:1 DebugDNSLevel: <1>:1 DebugL2FLevel: <1>:1 DebugPPPLevel: <1>:1 DebugRADIUSLevel: <1>:1 DebugACCTLevel: <1>:1 DebugNATLevel: <1>:1 DebugFOVERLevel: <1>:1 DebugSystemLevel: <1>:1 Configuration Transferred to STANDBY
This command displays the current debug settings.
debug showUse the debug show command to display the current debug settings.
SSG > debug show
Debug DHCP: Disabled [Active Level: (None)]
Debug DNS: Disabled [Active Level: (None)]
Debug L2F: Disabled [Active Level: (None)]
Debug PPP: Disabled [Active Level: (None)]
Debug RADIUS: Enabled [Active Level: ERROR ]
Debug ACCOUNTING: Disabled [Active Level: (None)]
Debug NAT: Disabled [Active Level: (None)]
Debug FAILOVER: Disabled [Active Level: (None)]
Debug SYSTEM: Enabled [Active Level: ERROR ]
This command enables or disables the failover feature for the Cisco 6510.
failover {enable | disable}| enable | Enables the failover feature. |
| disable | Disables the failover feature. |
Use the failover command to enable or disable the Cisco 6510's failover feature. For detailed information on how the failover feature works, see "Cisco 6510 Failover Mechanism".
SSG > failover enable SSG > failover disable
This command resets the failover mechanism for the Cisco 6510.
failover resetUse the failover reset command to reset the failover mechanism for the Cisco 6510. It is necessary to issue this command to activate failover without rebooting, when a serious hardware error is reported for either unit, or in the event that the failover cable becomes disconnected.
To use failover reset, first issue the command on the standby unit. Then, enter the command on the primary unit.
If you are activating failover for the first time, you must first issue the failover enable command described on the previous page.
SSG > failover reset Failover::Init: Initialize failover service hot... Failover Reset started. SSG>Failover::Init: Waiting for failover to initialize (COUNTDOWN: 10) Failover::Init: Waiting for failover to initialize (COUNTDOWN: 9) Failover::Init: Waiting for failover to initialize (COUNTDOWN: 8) FAILOVER: %%%%%%%%%%%%%SWITCHING INTERFACES to STANDBY %%%%%%%%%%%%%%%% FAILOVER: (failSwitch) unit(0): Switching to MAC(00:a0:c9:76:9c:a4) FAILOVER: (failSwitch) unit(0): Switching to IP... FAILOVER: (SwitchIP) Switching unit(0) to IP=<10.10.10.2>, mask=<255.255.0.0>, GW=<>, name=<host> FAILOVER: %%%%%%%%%%%%%SWITCHING INTERFACES to STANDBY %%%%%%%%%%%%%%%% FAILOVER: (failSwitch) unit(1): Switching to MAC(00:a0:c9:76:9c:38) FAILOVER: (failSwitch) unit(1): Switching to IP... FAILOVER: (SwitchIP) Switching unit(1) to IP=<171.69.255.20>, mask=<255.255.255.248>, GW=<171.69.255.18>, name=<ncp/isp> Failover::Init: Waiting for failover to initialize (COUNTDOWN: 7) Failover::Init: Initialization Done!
This command sets the IP addresses for each interface card in both the primary and standby Cisco 6510s.
failover set address| address | IP address for the standby unit. |
Use the failover set command to set the IP address for the standby unit that is cabled to the Cisco 6510 primary unit.
SSG > failover set FailoverActiveIP0 <198.46.3.2>: FailoverActiveIP1 <198.46.4.2>: FailoverActiveIP2 <198.46.5.2>: FailoverStandbyIP0 <0.0.0.0>: 198.46.6.2 FailoverStandbyIP1 <0.0.0.0>: 198.46.7.2 FailoverStandbyIP2 <0.0.0.0>: 198.46.8.2
| IP | Displays the IP addresses of the active and standby units. |
| stats | Displays status information of the active and standby units. |
Use the failover show command to display information about the active and standby units.
If you enter failover show IP, the console displays the IP address of the standby unit. If you enter failover show stats, the console displays failover status information.
For detailed information on how the failover feature works, see "Cisco 6510 Failover Mechanism".
SSG > failover show IP FailoverActiveIP0: <10.10.10.1> FailoverActiveIP1: <171.69.255.19> FailoverActiveIP2: <0.0.0.0> FailoverStandbyIP0: <10.10.10.2> FailoverStandbyIP1: <171.69.255.20> FailoverStandbyIP2: <0.0.0.0> SSG > failover show stats ---------------- Failover module real-time status -------------------- PRIMARY: Failover Monitor Enabled: ACTIVE (Peer Unit: STANDBY) 0: 10.10.10.1 (00:a0:c9:9b:7c:bf) LINK = up 1: 171.69.255.19 (00:a0:c9:9b:82:28) LINK = up Logical information: Interface fei1: READY Interface fei0: READY Total Number of Switchover Taken Place: 1
This command switches the Cisco 6510 to either active or standby status.
failover switchover {active | standby}| active | Makes the unit the active unit. |
| standby | Makes the unit the standby unit. |
Use the failover switchover command to switch the Cisco 6510 to active or standby. For detailed information on how the failover feature works, see "Cisco 6510 Failover Mechanism".
SSG > failover switchover active SSG > failover switchover standby
This command tests the failover feature for the Cisco 6510.
failover testUse the failover test command to test the Cisco 6510's failover feature. For detailed information on how the failover feature works, see "Cisco 6510 Failover Mechanism".
SSG > failover test ---------------- Failover module Self Test -------------------- FAILOVER: (selfTest) tNetTask OK. FAILOVER: (selfTest) Cable OK. FAILOVER: (selfTest) Ethernet(1) OK. FAILOVER: (selfTest) Ethernet(0) OK. FAILOVER: (selfTest) Succeeded: Passed All Tests.
This command displays the hardware configuration of the Cisco 6510.
hardwareUse the hardware command to display the hardware configuration of the Cisco 6510.
SSG > hardware
INTEL Processor: <GenuineIntel>
OEM: Pentium II processor, model 3
Total Memory: 402649 Kbytes
*** Skipped Failover Cable Loopback Test; Not Allowed with Failover Enabled ***
Ethernet Cards:
VEGA diagnostics: Intel 82557 #0 found at pciDevice number 13
***
82557(0): Intel PRO100+ FE at 0xfc40 00:A0:C9:9B:7C:BF
CSR mem base address = feaff000, Flash mem base address = feb00000
PCI bus no. = 0, device no. = d, function no. = 0, IRQ = 15
Board assembly 678400-001, Physical connectors present: RJ45
Primary interface chip unknown PHY #1.
General self-test: passed.
Serial sub-system self-test: passed.
Internal registers self-test: passed.
ROM checksum self-test: passed (0x49caa8d6).
***
VEGA diagnostics: Intel 82557 #1 found at pciDevice number 14
***
82557(1): Intel PRO100+ FE at 0xfcc0 00:A0:C9:9B:82:28
CSR mem base address = feafe000, Flash mem base address = fed00000
PCI bus no. = 0, device no. = e, function no. = 0, IRQ = 11
Board assembly 678400-001, Physical connectors present: RJ45
Primary interface chip unknown PHY #1.
General self-test: passed.
Serial sub-system self-test: passed.
Internal registers self-test: passed.
ROM checksum self-test: passed (0x49caa8d6).
***
This command configures a Cisco 6510 interface card.
ifconfig -u unit -a inetAdrs -m netMask [-g inetGateway] [-n inetName]| unit | Card number of the interface card (card number 0, 1, or 2). |
| inetAdrs | IP address assigned to the interface card. |
| netMask | Subnet mask assigned to the interface card. |
| inetGateway | Default gateway (optional). |
| inetName | String identifying the interface card (optional). |
Use the ifconfig command to configure an interface card installed in the Cisco 6510. All cards in the Cisco 6510 should be assigned an IP address and subnet mask.
Parameters set with the ifconfig command do not take effect until the Cisco 6510 is rebooted.
SSG > ifconfig -u 0 -a 198.46.3.2 -m 255.255.255.0 SSG > ifconfig -u 1 -a 198.46.4.2 -m 255.255.255.0 -n UCPcard SSG > ifconfig -u 2 -a 198.46.5.2 -m 255.255.255.0 -g 198.46.5.1
The logtarget command specifies where to log debugging messages.
logtarget target0 -t output_type [-d ip_address]| output_type | Output device where messages are sent. You can specify the following devices:
tty-- messages sent to the terminal console connected to the Cisco 6510 syslog--messages sent to the syslog file for the system with the IP address specified with the -d parameter |
| ip_address | If you specify syslog for the output_type parameter, this parameter specifies the IP address of the syslog server to which you want to output logging information. |
The logtarget command can set up to five output devices to receive debug messages from the Cisco 6510. The output devices can include the console device connected to the Cisco 6510 and syslog files on systems connected to the Cisco 6510.
If you specify syslog for the output_type parameter, you must specify the IP address of the system with the ip_address parameter.
SSG > logtarget target0 -t tty SSG > logtarget target1 -t syslog -d 198.100.5.5 SSG > logtarget target2 -t syslog -d 198.105.5.5 SSG > logtarget target3 -t syslog -d 205.100.5.5 SSG > logtarget target4 -t syslog -d 207.98.5.5
Specifies the UNIX syslog facility used to monitor debug messages.
logtarget facility {local0... | local7}| local0...|local7 | Local device to receive debug messages. |
Use the logtarget facility command to specify the local device to which the Cisco 6510 writes debug messages.
SSG > logtarget facility local0 Log Facility Set.
Displays the logging targets currently configured for the Cisco 6510.
logtarget showUse the logtarget show command to display a list of the logging targets to which the Cisco 6510 is currently sending logging information. This command is useful in case you need to change the logging targets and do not remember what devices are currently receiving logging information.
SSG > logtarget show Target0: 192.168.15.22 Target1: 0.0.0.0 Target2: 0.0.0.0 Target3: 0.0.0.0 Target4: 0.0.0.0 Log Facility: LOCAL1
This command causes the Cisco 6510 to shut down and reboot using the configuration stored in Flash memory.
rebootIssue the reboot command to reboot the Cisco 6510 using the configuration stored in Flash memory.
SSG > reboot System configuration has been modified. Save? [y/n]: y Proceed with reboot? [y/n]: y
This command specifies the remote ports the Cisco 6510 uses to receive packets from different services.
remoteport set -h service -p port| service | You can set ports for receiving packets from the following services:
dhcp-- Dynamic Host Configuration Protocol Service dns-- Domain Name System Service radius--Remote Access Dial-In User Service l2f--Layer 2 Forwarding Service accounting--Accounting Service |
| port | Port which the Cisco 6510 uses to receive packets from the specified service. |
Use the remoteport set command to specify the ports the Cisco 6510 uses to receive packets from services.
Parameters set with the remoteport set command do not take effect until the Cisco 6510 is rebooted.
SSG > remoteport set -h dhcp -p 67 DHCPRemotePort = <67>
This command displays the port setting for a specified service.
remoteport show [-h service]| service | You can view the port setting for the following services:
dhcp-- Dynamic Host Configuration Protocol Service dns-- Domain Name System Service radius--Remote Access Dial-In User Service l2f--Layer 2 Forwarding Service accounting--Accounting Service |
SSG >remoteport show -h dhcpDHCPRemotePort = <67> SSG >remoteport showDHCPRemotePort = <67> DNSRemotePort = <53> RadiusRemotePort = <1645> L2FRemotePort = <1701> AccountingRemotePort = <1646>
| secret_string | Text string containing the password. |
Use the secret dashboardpassword command to specify the password used for the RADIUS communication between the Cisco 6510 and the Dashboard application.
SSG > secret dashboardpassword secret1
| secret_string | Text string containing the password. |
Use the secret aaapassword command to specify the password used to encrypt data exchanged between the Cisco 6510 and the AAA server.
SSG > secret aaapassword secret2
This command sets the IP addresses for the default server , RADIUS services, and the DHCP server.
server [name [ip_address]]
| name | Name of the server or service:
defaultserverip--server from which the Dashboard application is downloaded aaaip1--first AAA authentication and authorization service aaaip2--second AAA authentication and authorization service accountingip1--first AAA accounting service accountingip2--second AAA accounting service dhcpip--DHCP server |
| ip_address | IP address of the server of service. |
Use the server command to set the IP addresses for the default server , RADIUS services, and the DHCP server. If you enter server by itself, the Cisco 6510 will prompt you to enter each IP address. If you enter server followed by the name of the service, the Cisco 6510 will prompt you to enter the IP address for that service.
SSG > server dhcpip 136.123.56.57 SSG > server DefaultServerIP: <0.0.0.0>: 192.168.1.2 AAAIP1: <0.0.0.0>: 171.69.73.151 AAAIP2: <0.0.0.0>: 171.69.73.152 AccountingIP1: <0.0.0.0>: 175.63.73.250 AccountingIP2: <0.0.0.0>: 175.63.73.251 DHCPIP: <0.0.0.0>: 136.123.56.57
This command displays the version of the firmware installed in the Cisco 6510.
Issue the version command to display the version of the currently installed firmware.
SSG > version Service Selection Gateway Version 1.0.(Build 41, Mar 11 1998, 18:29:06) Copyright (c) 1998 by Cisco Systems, Inc. Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Compute Software - Restricted Rights clause as FAR sec. 32.227-19 and subparagraph (c) (i) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.227-7013. Cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95134-1706
|
|