cc/td/doc/product/access/acs_serv/5300
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Replacing DSPMs in the Cisco AS5300 Universal Access Server

Replacing DSPMs in the Cisco AS5300 Universal Access Server

Product Number: DOC-785891=, DOC-AS5300SWG=, AS53-VOXD=, AS53-6VOX=

This document describes how to replace and configure DSP modules on the Voice-over-IP (VoIP) card for the Cisco AS5300 universal access server. Use this document with the installation material shipped with the product, the Cisco AS5300 Universal Access Server Module Installation Guide, the Cisco AS5300 Universal Access Server Software Configuration Guide, and the Regulatory Compliance and Safety Information document.

This document includes the following sections:

Safety Recommendations

This section describes the safety warnings and recommendations you must take into consideration when working on voice card DSP modules for the Cisco AS5300 universal access server. This section includes the following topics:

Safety Warnings

Safety warnings appear throughout this document in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each safety warning.

Warning  

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Waarschuwing  Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.

Varoitus  Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention  Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.

Warnung  Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.

Avvertenza  Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.

Advarsel  Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.

Aviso  Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.

¡Advertencia!  Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.

Varning!  Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.

Safety with Electricity

Warning
Read the installation instructions before you connect the system to its power source.
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.

Warning   

Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units.

Warning
To ensure your safety and the safety of others, be sure the power is OFF and the power cord is unplugged before working on the router.
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Warning
Before opening the chassis, disconnect the telephone-network cables to avoid contact with telephone-network voltages.
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Warning
Do not touch the power supply when the power cord is connected. For systems with a power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected.
Warning
Before performing any procedures involving installing or removing chassis elements, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
Warning
Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units.
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Warning
Only trained and qualified service personnel should be allowed to install or replace this equipment.
Caution
Before opening the chassis, ensure that you have discharged all static electricity from your body and be sure that the power is OFF.

Follow these guidelines when working on equipment powered by electricity:

Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Always follow ESD prevention procedures when removing and replacing cards. Ensure that the chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground. To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.

Caution
For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohm (Mohm).

General Safety Recommendations

Follow these guidelines to ensure general safety:

Required Tools and Equipment

To install or remove voice cards with DSP modules or perform other maintenance procedures, you will need the following tools and equipment, which are not included:

Software Requirements

The following Cisco IOS Release images are required for the 542 DSP and 549 DSP modules:

DSPM Replacement Procedures

This section describes how to remove and install VoIP cards and modules. This section describes how to:

Removing VoIP Cards

If you are installing (rather than replacing) a card, skip this topic.

To remove the VoIP card, perform the following steps:

Step 1 Attach an ESD-preventive wrist strap.

Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Caution
The cards are not hot-swappable (that is, you cannot remove or install them when the power to the access server is ON). Be sure to turn OFF the power to the access server before installing or removing cards. Failure to do so can damage the access server.

Step 2 Power OFF the access server. Turn the power switch on the access server OFF and disconnect site power. If using a DC-powered unit, read the warning that follows, then refer to Figure 1 and complete steps a to d.

Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.

Figure 1: DC Power Supply Connections

Step 3 On the rear panel of the access server, locate the VoIP card seen in Figure 2.

Step 4 Loosen the two captive screws that secure the VoIP card to the chassis until each screw is free of the chassis. (See Figure 2.)


Figure 2: VoIP Card Removal


Step 5 Insert the card removal tool so that the slots in each arm of the tool are behind the shoulder of each captive screw, as shown in Figure 3, and carefully pull the removal tool toward you until the VoIP card slides free of the chassis.

Caution
The EMI protective devices on the VoIP card are designed to make the card fit tightly. When removing the card, they can release suddenly. Exercise caution when removing the VoIP card with the card removal tool.

Figure 3: Removing VoIP Card


Step 6 Set the removed VoIP card aside on an ESD-preventive mat.

Step 7 Continue with one of the following sections:

Removing DSP Modules

If you are installing a new card with modules already mounted on it, go directly to the topic, "Installing VoIP Cards."

To remove DSP modules:

Step 1 Make sure that you have attached an ESD-preventive wrist strap and that the system is powered OFF.

Step 2 On the VoIP card, locate the DSP module you will replace. (See Figure 4.)


Figure 4: Removing DSP Modules

Step 3 Orient the VoIP card so that the DSP module socket is facing toward you.

Step 4 Gently pry the front edge of the DSP module away from the standoffs and the socket, as indicated by the arrow labeled 1 in Figure 4.

Step 5 When the DSP module is free of the socket, gently pry the back edge of the DSP module away from the other set of standoffs, as indicated by the arrow labeled 2 in Figure 4.

Installing DSP Modules

If you are installing a new card with modules already mounted on it, go directly to the topic, "Installing VoIP Cards."

To install a DSP module:

Step 1 Seat the DSP module in the socket.

Step 2 Press all four corners onto their respective standoffs, as shown in Figure 5.


Figure 5: Installing DSP Modules



Note Mate the socket on the DSP module with the socket on the VoIP card.

Step 3 Continue with the following section, "Installing VoIP Cards" to install the VoIP card.

Installing VoIP Cards

To install a VoIP card:

Step 1 Remove the VoIP card from the ESD-preventive mat.

Step 2 Slide the VoIP card into the slot until it touches the backplane connector.

Step 3 Align the captive screws with their holes, and then seat the VoIP card completely.

Step 4 Tighten the two captive screws (see Figure 6) to secure the VoIP card to the chassis.


Figure 6: Installing the VoIP Card


Step 5 If the access server is configured with fewer than three cards, make sure that a blank slot cover is installed over each open slot to ensure proper airflow inside the chassis.

Step 6 Reconnect the AC power cord. Or, if using DC power, refer to Figure 7, and then complete steps a to d.

Caution
The illustration shows the DC power supply terminal block. Wire the DC power supply using the appropriate wire terminations at the wiring end, as illustrated. The proper wiring sequence is ground to ground, positive to positive, and negative to negative. Note that the ground wire should always be connected first and disconnected last.

Figure 7: DC Power Supply Connections


Caution
Do not overtorque the terminal block contact screws. The recommended torque is 8.2 ± 0.4 inch-lb.
Warning
After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position.

Step 7 Power ON the access server.

The internal power supply fan should power on.

Step 8 Continue with the section, "Upgrading VoIP Card VCWare ."

Preparing to Configure the Software for Voice

Before you can configure your Cisco AS5300 to use VoIP, you must first complete the tasks listed below. If your Cisco AS5300 is already configured to use VoIP, you can skip this section.

To configure your Cisco AS5300 to use VoIP:

For more information about these configuration tasks, refer to the Cisco AS5300 Universal Access Server Software Configuration Guide.

For detailed procedures, see the Cisco AS5300 Universal Access Server Software Configuration Guide. You can find the most up-to-date version of this manual online from either CCO or the CD-ROM.

Services & Support: Technical Documents: Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5300: Cisco AS5300 Universal Access Server Software Configuration Guide.
Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5300: Cisco AS5300 Universal Access Server Software Configuration Guide.

For detailed examples of command output, see the Voice Over IP for the Cisco AS5300 Configuration Guide. You can find the most up-to-date version of this manual online from either CCO or the CD-ROM.

Services & Support: Technical Documents: Cisco Product Documentation: Access Servers and Access Routers: Cisco Voice Over IP Documentation: Voice Over IP for the Cisco AS5300: Voice Over IP for the Cisco AS5300 Configuration Examples.
Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco Voice Over IP Documentation: Voice Over IP for the Cisco AS5300: Voice Over IP for the Cisco AS5300 Configuration Examples.

Upgrading VoIP Card VCWare

To download VCWare to your voice card, you need to:

    1. Identify voice cards in the system and determine whether the VFC is in VCWare mode or ROM monitor mode. This determines how you download software to the VFC. (See "Identify Voice Cards," .)

    2. Check to see that the version of VFC ROM monitor software version 1.2 or 1.3 is compatible with your installed Cisco IOS image. VCWare version 4.0 (or later) requires Cisco IOS Release 12.0(2)XH, 12.0(5)TPI, or later.

    3. Download the software using the appropriate procedure.


Note In certain countries, use of these products or provision of voice telephony over the Internet may be prohibited and/or subject to laws, regulations or licenses, including requirements applicable to the use of the products under telecommunications and other laws and regulations; customer must comply with all such applicable laws in the country(ies) where customer intends to use the product.

Identify Voice Cards

Use the following steps to identify the voice cards in the system and determine whether the VFC is in VCWare mode or ROM monitor mode. This determines how you download software to the VFC. If there is not VCWare loaded on the VFC, you can use the ROM monitor mode to download the VCWare. Otherwise the VCWare mode is active.


Table 1: Identifying Voice Cards
Step Command Purpose
1
5300>enable

Password: <password>
5300#

Enter enable mode (also called Privileged EXEC mode).

Enter the password.

You have entered enable mode when the prompt changes to 5300#.

2
5300#show vfc <0-2> board

Determine the number of voice cards in the system, the slot number for each card, and the VFC mode (VCWare or ROM monitor) in which you are running.

The VFC mode is indicated as follows:

  • VCWARE running for VCWare mode
    or

  • ROMMON for ROM monitor mode

Note the location and the mode type for each voice card. You will need this information when you upgrade the VCWare.

Go to one of the following sections to continue the procedure to upgrade the VCWare:

Replace Firmware with VCWare in VCWare Mode

Configure

Use the steps that follow to download new voice software if your voice card is running in VCWare mode. When downloading from a diskette, first copy the software from the diskette to a TFTP server. After the software is on the TFTP server, begin the following steps.

Caution
Erasing the VFC files can result in system outage or the corruption of your VFC board. Check to ensure that the correct version of software resides on your TFTP server before continuing.

Table 2: Replace Firmware in VCWare Mode 
Step Command Purpose
1 (optional)




5300#erase vfc slot_number This will erase the contents of VFC Flash. Continue ?[y/n]:yes This will take some time. Please, wait...vfc
NoteSee the Caution before this table before continuing.

Erase the contents of the VFC Flash memory in the selected voice card.

If this command fails, use the section "Replace Firmware with VCWare in ROM Monitor Mode."

2 (optional)
5300#show vfc slot_number directory

Verify the VFC Flash memory is empty.

3
5300#copy tftp: vfc: 

Address or name of remote host []? 
223.255.212.244

Source file name []? /path/vcw-vfc-mz.4.0.bin 
Destination file name []? vcw-vfc-mz.4.0.bin

Accessing tftp://223.255.212.244/path/ 
vcw-vfc-mz.4.0.bin... 
Loading vcw-vfc-mz.4.0.bin from 223.255.212.244 
(via Ethernet0):
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!![OK - 491256/982016 bytes]
 

Use TFTP to download the new VCWare to VFC Flash memory. In this example, slot 1 is chosen by default.

Note The destination image name must begin with "vcw-" (all lowercase) and no other character can be in front of vcw-, so no directory path should be included at the beginning of the image name. Be absolutely certain to get the name right. If one character or space is wrong, the file will not be recognized and will not be copied over.
4
5300#show vfc slot_number directory

5300#

Verify that VCWare is in the VFC Flash memory by providing a list of files.

5
5300#clear vfc slot_number 
5300#
 

Reloads the VFC code from Flash memory for the specified slot before you unbundle the new VFC image.

6
5300#unbundle vfc slot_number






Do you want to continue ? [y/n]: y

Unbundle the DSPWare from the VCWare and configure the default file and capability lists with default values. This rewrites the default-file and capabilities lists. (See Step 8 and Step 9.)

Continue by pressing y when the prompt appears.

7
5300#show vfc slot_number directory

5300#

Verify that the DSPWare is unbundled by providing a list of files.

8
5300#show vfc slot_number default-file

5300#

Verify that the default file list is initialized by providing a list of files.

9
5300#show vfc slot_number cap-list

5300#

Verify that the capability list is populated by providing a list of files.

10
5300#reload 

Reboot the Cisco AS5300 so these changes take effect.

Verify

To check that you have successfully downloaded the software:

5300# show vfc 1 dir
 
Files in slot 1 VFC flash:
	File Name 	Size (Bytes)
1 .  vcw-vfc-mz.4.0.bin	466168
2 .  btl-vfc-l.4.0.bin	4174
3 .  btj-vfc-l.4.0.bin	3868
4 .  jbc-vfc-l.4.0.bin	12756
5 .  cor-vfc-hc-l.4.0.bin	47754
6 .  bas-vfc-hc-l.4.0.bin	38634
7 .  fax-vfc-hc-l.4.0.bin	80794
8 .  cdc-g711-hc-l.4.0.bin	218
9 .  cdc-g726-hc-l.4.0.bin	218
10.  cdc-g729-hc-l.4.0.bin	31516
11.  cdc-g728-hc-l.4.0.bin	24334
12.  cdc-g723.1-hc-l.4.0.bin	47234
 
5300# show vfc 1 def (full word is default-file) 
 
Default File List for VFC in slot 1: 
 
1. btl-vfc-l.4.0.bin
2. cor-vfc-hc-l.4.0.bin
3. bas-vfc-hc-l.4.0.bin
4. cdc-g729-hc-l.4.0.bin
5. fax-vfc-hc-l.4.0.bin
6. jbc-vfc-l.4.0.bin
7. btj-vfc-1.4.0.bin
 
5300# show vfc 1 cap-list
 
Capability List for VFC in slot 1: 
 
1. cor-vfc-hc-l.4.0.bin
2. bas-vfc-hc-l.4.0.bin
3. fax-vfc-hc-l.4.0.bin
4. cdc-g711-hc-1.4.0.bin
5. cdc-g726-hc-1.4.0.bin
6. cdc-g729-hc.1.4.0.bin
7. cdc-g728-hc-1.4.0.bin
8. cdc-g723.1-hc-1.4.0.bin
 
5300#
 
Tips

If you are having trouble downloading the voice card software in VCWare mode, try the following:

5300# show vfc 1 board
VFC board state is UP, vfc status VCWARE running(0x4)
VFC board in slot 1 with 24 dsps
5300#
 
5300# sh vfc 1 ver vcw
 
Voice Feature Card in Slot 1:
     VCware Version	: 4.0
     ROM Monitor Version	: 1.2
     DSPware Version 	: 4.0
Technology	: C549
 

Replace Firmware with VCWare in ROM Monitor Mode

Configure

Use the steps that follow to download new voice software if your voice card is running in ROM monitor mode. When downloading from a diskette, first copy the software from the diskette to a TFTP server. After the software is on the TFTP server, begin the following steps.

Caution
Erasing the VFC files can result in system outage or the corruption of your VFC board. Check to ensure that the correct version of software resides on your TFTP server before continuing.


Table 3: Replace Firmware in ROM Monitor Mode 
Step Command Purpose
1 (optional)




5300#clear vfc slot_number purge debug vfc <slot#> start debug vfc <slot#> cons flash erase
This will erase the contents of VFC Flash. Continue ?[y/n]: y This will take some time. Please, wait...vfc
NoteSee the Caution before this table before continuing.

Erase the contents of the VFC Flash memory in the selected voice card. This may take awhile.

Press y to continue.
2
5300#copy tftp: vfc: 

Address or name of remote host []? 
223.255.212.244

Source file name []? /path/vcw-vfc-mz.4.0.bin 
Destination file name []? vcw-vfc-mz.4.0.bin

Accessing tftp://223.255.212.244/path/ 
vcw-vfc-mz.4.0.bin... 
Loading vcw-vfc-mz.4.0.bin from 223.255.212.244 
(via Ethernet0):
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!![OK - 491256/982016 bytes]

Use TFTP to download the new VCWare to VFC Flash memory. In this example, slot 1 is chosen by default.

Note The destination image name must begin with "vcw-" (all lowercase) and no other character can be in front of vcw-, so no directory path should be included at the beginning of the image name. Be absolutely certain to get the name right. If one character or space is wrong, the file will not be recognized and will not be copied over.
3
5300#show vfc slot_number technology

5300#

Reports the type of DSPs supported (C542 or C549) by the VCWare.

4
5300>clear vfc slot_number


Do you really want to reset this card ? [y/n] y Please, wait...

Reloads the VFC code from Flash memory for the specified slot before you unbundle the new VFC image.

Press y to verify the reset function.

5
5300#unbundle vfc slot_number





Do you want to continue ? [y/n]: y

Unbundle the DSPWare from the VCWare and configure the default file list and the capability list. (See Step 7 and Step 8.)

Continue by pressing y when the prompt appears.

6
5300#show vfc slot_number directory

5300#

Verify that the DSPWare is unbundled.

7
5300#show vfc slot_number default-file

5300#

Verify that the default file list is initiated.

8
5300#show vfc slot_number cap-list

5300#

Verify that the capability list is initiated.

9
5300#reload 

Reboot the Cisco AS5300 so these changes take effect.

Verify

To check that you have successfully downloaded the software:

5300# show vfc 1 dir
 
Files in slot 1 VFC flash:
	File Name 	Size (Bytes)
1 .  vcw-vfc-mz.4.0.bin	466168
2 .  btl-vfc-l.4.0.bin	4174
3 .  btj-vfc-l.4.0.bin	3868
4 .  jbc-vfc-l.4.0.bin	12756
5 .  cor-vfc-hc-l.4.0.bin	47754
6 .  bas-vfc-hc-l.4.0.bin	38634
7 .  fax-vfc-hc-l.4.0.bin	80794
8 .  cdc-g711-hc-l.4.0.bin	218
9 .  cdc-g726-hc-l.4.0.bin	218
10.  cdc-g729-hc-l.4.0.bin	31516
11.  cdc-g728-hc-l.4.0.bin	24334
12.  cdc-g723.1-hc-l.4.0.bin	47234
 
5300# show vfc 1 def (full word is default-file) 
 
Default File List for VFC in slot 1: 
 
1. btl-vfc-l.4.0.bin
2. cor-vfc-hc-l.4.0.bin
3. bas-vfc-hc-l.4.0.bin
4. cdc-g729-hc-l.4.0.bin
5. fax-vfc-hc-l.4.0.bin
6. jbc-vfc-l.4.0.bin
7. btj-vfc-1.4.0.bin
 
5300# show vfc 1 cap-list
 
Capability List for VFC in slot 1: 
 
1. cor-vfc-hc-l.4.0.bin
2. bas-vfc-hc-l.4.0.bin
3. fax-vfc-hc-l.4.0.bin
4. cdc-g711-hc-1.4.0.bin
5. cdc-g726-hc-1.4.0.bin
6. cdc-g729-hc.1.4.0.bin
7. cdc-g728-hc-1.4.0.bin
8. cdc-g723.1-hc-1.4.0.bin
 
5300#
Tips

If you are having trouble downloading the voice card software in ROM monitor mode, try the following:

5300# show vfc 1 board
VFC board state is UP, vfc status VCWARE running(0x4)
VFC board in slot 1 with 24 dsps
5300#
 
5300# sh vfc 1 ver vcw
 
Voice Feature Card in Slot 1:
     VCware Version	: 4.0
     ROM Monitor Version	: 1.2
     DSPware Version 	: 4.0
Technology	: C549
 

Cisco Connection Online

Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.

Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CCO in the following ways:

For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.


Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.

Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.





hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed May 19 16:11:57 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.