cc/td/doc/product/access/acs_serv/5100_sbd
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Cable and Port Specifications

Cable and Port Specifications

This appendix provides pinout information for the Cisco Access Server 5100 interface ports and cables.

AS51 NAC Console, Auxiliary, and RJ-45 Port Pinouts

The AS51 network application card (NAC) console port is configured as data communications equipment (DCE), and the auxiliary port is configured as data terminal equipment (DTE). The console and auxiliary ports both use RJ-45 connectors. RJ-45-to-DB-25 adapters are available for connection to modems and other external communications equipment. Both ports are configured as asynchronous serial ports.

Following are the pinouts for the console port (see Table B-1), the auxiliary port (see Table B-2), and the RJ-45 Ethernet port (see Table B-3).


Table  B-1: AS51 NAC Console Port Pinouts (RJ-45-to-DB-25 Female)
Console Port (DCE) RJ-45-to-DB-25 Adapter
Pin1 Signal Input/Output RJ-45 Pin Signal DB-25 Pin
1 - - 1 CTS 4
2 CD Output 2 DSR 20
3 RxD Output 3 RxD 2
4 GND - 4 GND 7
5 GND - 5 GND 7
6 TxD Input 6 TxD 3
7 DTR Input 7 DTR 6
8 - - 8 RTS 5

1 Any pin not referenced is not connected.

Table  B-2: Access Server NAC Auxiliary Port Pinouts (RJ-45-to-DB-25 Male)
Auxiliary Port (DTE) RJ-45 to DB-25 Adapter
Pin1 Signal Input/Output RJ-45 Pin Signal DB-25 Pin
1 CTS Input 1 CTS 5
2 CD/RING Input 2 DSR 6
3 RxD Input 3 RxD 3
4 GND - 4 GND 7
5 GND - 5 GND 7
6 TxD Output 6 TxD 2
7 DTR Output 7 DTR 20
8 RTS Output 8 RTS 4

1 Any pin not referenced is not connected.

Table  B-3: Access Server NAC RJ-45 Ethernet Port Pinouts
Pin1 IEEE Name Description
1 TD+ Transmit data +
2 TD- Transmit data -
3 RD+ Receive data +
4 Not used
5 Not used
6 RD- Receive data -
7 Not used
8 Not used

AS51 NIC Asynchronous Port Cables and Pinouts

Figure B-1 shows the asynchronous serial interface DB-50 breakout cable assembly, and Table B-4 contains the pinout information. The breakout cable is used to connect one asynchronous serial port on an AS51 network interface card (NIC) to serial ports on two quad modem NICs.


Figure B-1: Asynchronous Serial Interface DB-50 Breakout Cable Assembly


Table  B-4:
68-Pin SCSI to Dual DB-50 Breakout Cable Pinouts
Signal HD-68Pin --> HD-50 Cable 1 Pin HD-50 Cable 2 Pin Signal HD-68Pin --> HD-50 Cable 1 Pin HD-50 Cable 2 Pin
DGND 1 7 - DGND 351 - -
RTS0 2 3 - DTR0 36 5 -
TXD0 3 1 - DGND 37 19 -
- 4 - - RXD0 38 2 -
DSR0 5 6 - CTS0 39 4 -
RTS1 6 28 - DTR1 40 30 -
TXD1 7 26 - DGND 41 32 -
- 8 - - RXD1 42 27 -
DSR1 9 31 - CTS1 43 29 -
RTS2 10 40 - DTR2 44 42 -
TXD2 11 38 - DGND 45 44 -
12 - - RXD2 46 39 -
DSR2 13 43 - CTS2 47 41 -
RTS3 14 15 - DTR3 48 17 -
TXD3 15 13 - DGND 49 - 7
16 - - RXD3 50 14 -
DSR3 17 18 - CTS3 51 16 -
RTS4 18 - 3 DTR4 52 - 5
TXD4 19 - 1 DGND 53 - 19
20 - - RXD4 54 - 2
DSR4 21 - 6 CTS4 55 - 4
RTS5 22 - 28 DTR5 56 - 30
TXD5 23 - 26 DGND 57 - 32
24 - - RXD5 58 - 27
DSR5 25 - 31 CTS5 59 - 29
RTS6 26 - 40 DTR6 60 - 42
TXD6 27 - 38 DGND 61 - 44
28 - - RXD6 62 - 39
DSR6 29 - 43 CTS6 63 - 41
RTS7 30 - 15 DTR7 64 - 17
TXD7 31 - 13 DGND 65 - 25
32 - - RXD7 66 - 14
DSR7 33 - 18 CTS7 67 - 16
CABLE 341 - - CGND 68 50 -

1 Pin 34 of HD-68 must be connected to pin 35.

AS51 NAC Synchronous Port Serial Cables and Pinouts

The illustrations and tables in this section provide assembly drawings and pinout for the EIA/TIA-530 DTE, EIA/TIA-232, EIA/TIA-449, V.35, and X.21 DTE and DCE cables, and the synchronous serial interface port pinouts.

EIA/TIA-530 DTE Cable and Pinouts

Figure B-2 shows the EIA/TIA-530 DTE cable assembly. Table B-5 lists the EIA/TIA-530 DTE cable pinouts. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.


Figure B-2: EIA/TIA-530 DTE Cable Assembly


Table  B-5: EIA-530 DTE Male Cable Pinout (DB-60 to DB-25)

60 Pin2

Signal

25 Pin

Signal
Direction
DTE  DCE
J1-1
J1-2
CTS/RTS+
CTS/RTS-
J2-5
J2-13
CB(A), CTS+
CB(B), CTS-
<--
<--
J1-3
J1-4
DSR/DTR+
DSR/DTR-
J2-6
J2-22
CC(A), DSR+
CC(B), DSR-
<--
<--
J1-5
J1-6
DCD/DCD+
DCD/DCD-
J2-8
J2-10
CF(A), DCD+
CF(B), DCD-
<--
<--
J1-7
J1-8
DTR/DSR+
DTR/DSR-
J2-20
J2-23
CD(A), DTR+
CD(B), DTR-
-->
-->
J1-9
J1-10
RTS/CTS+
RTS/CTS-
J2-4
J2-19
CA(A), RTS+
CA(B), RTS-
-->
-->
J1-11
J1-12
TxD/RxD+
TxD/RxD-
J2-2
J2-14
BA(A), TxD+
BA(B), TxD-
-->
-->
J1-13
J1-14
TxCE/TxC+
TxCE/TxC-
J2-24
J2-11
DA(A), TxCE+
DA(B), TxCE-
-->
-->
J1-24
J1-23
TxC/RxC+
TxC/RxC-
J2-15
J2-12
DB(A), TxC+
DB(B), TxC-
<--
<--
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
J2-17
J2-9
DD(A), RxC+
DD(B), RxC-
<--
<--
J1-28
J1-27
RxD/TxD+
RxD/TxD-
J2-3
J2-16
BB(A), RxD+
BB(B), RxD-
<--
<--
J1-44
J1-45
LL/DCD
Circuit_GND
J2-18
J2-7
LL
Circuit_ GND
-->
-
J1-46
J1-47
Shield_GND
MODE_2
J2-1
-
Shield
-
Shorted
J1-48
J1-49
GND
MODE_1
-
-
-
-
Shorted
J1-51
J1-52
GND
MODE_DCE
-
-
-
-
Shorted

EIA/TIA-232 Cables and Pinouts

Figure B-3 shows the EIA/TIA-232 cable assembly. Table B-6 lists the EIA/TIA-232 DTE pinout; and Table B-7 lists the EIA/TIA-232 DCE pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.


Figure B-3: EIA/TIA-232 Cable Assembly


Table  B-6:
EIA/TIA-232 DTE Male Cable Pinout (DB-60-to-DB-25)
60 Pin3 Signal Description Direction 25 Pin Signal
J1-50
J1-51
J1-52
MODE_0
GND
MODE_DCE
Shorting group - - -
J1-46 Shield GND Single - J2-1 Shield GND
J1-41
Shield
TxD/RxD
-
Twisted pair no. 5 -->
-
J2-2
Shield
TxD
-
J1-36
Shield
RxD/TxD
-
Twisted pair no. 9 <--
-
J2-3
Shield
RxD
-
J1-42
Shield
RTS/CTS
-
Twisted pair no. 4 -->
-
J2-4
Shield
RTS
-
J1-35
Shield
CTS/RTS
-
Twisted pair no. 10 <--
-
J2-5
Shield
CTS
-
J1-34
Shield
DSR/DTR
-
Twisted pair no. 11 <--
-
J2-6
Shield
DSR
-
J1-45
Shield
Circuit GND
-
Twisted pair no. 1 -
-
J2-7
Shield
Circuit GND
-
J1-33
Shield
DCD/LL
-
Twisted pair no. 12 <--
-
J2-8
Shield
DCD
-
J1-37
Shield
TxC/NIL
-
Twisted pair no. 8 <--
-
J2-15
Shield
TxC
-
J1-38
Shield
RxC/TxCE
-
Twisted pair no. 7 <--
-
J2-17
Shield
RxC
-
J1-44
Shield
LL/DCD
-
Twisted pair no. 2 -->
-
J2-18
Shield
LTST
-
J1-43
Shield
DTR/DSR
-
Twisted pair no. 3 -->
-
J2-20
Shield
DTR
-
J1-39
Shield
TxCE/TxC
-
Twisted pair no. 6 -->
-
J2-24
Shield
TxCE
-

Table  B-7:
EIA/TIA-232 DCE Female Cable Pinout (DB-60-to-DB-25)
60 Pin4 Signal Description Direction 25 Pin Signal
J1-50
J1-51
MODE_0
GND
Shorting Group -
-
-
J1-46 Shield GND Single - J2-1 Shield GND
J1-36
Shield
RxD/TxD
-
Twisted pair no. 9 <--
-
J2-2
Shield
TxD
-
J1-41
Shield
TxD/RxD
-
Twisted pair no. 5 -->
-
J2-3
Shield
RxD
-
J1-35
Shield
CTS/RTS
-
Twisted pair no. 10 <--
-
J2-4
Shield
RTS
-
J1-42
Shield
RTS/CTS
-
Twisted pair no. 4 -->
-
J2-5
Shield
CTS
-
J1-43
Shield
DTR/DSR
-
Twisted pair no. 3 -->
-
J2-6
Shield
DSR
-
J1-45
Shield
Circuit GND
-
Twisted pair no. 1 -
-
J2-7
Shield
Circuit GND
J1-44
Shield
LL/DCD
-
Twisted pair no. 2 -->
-
J2-8
Shield
DCD
-
J1-39
Shield
TxCE/TxC
-
Twisted pair no. 7 -->
-
J2-15
Shield
TxC
-
J1-40
Shield
NIL/RxC
-
Twisted pair no. 6 -->
-
J2-17
Shield
RxC
-
J1-33
Shield
DCD/LL
-
Twisted pair no. 12 <--
-
J2-18
Shield
LTST
-
J1-34
Shield
DSR/DTR
-
Twisted pair no. 11 <--
-
J2-20
Shield
DTR
-
J1-38
Shield
RxC/TxCE
-
Twisted pair no. 8 <--
-
J2-24
Shield
TxCE
-

EIA/TIA-449 Cables and Pinouts

Figure B-4 shows the EIA/TIA-449 cable assembly. Table B-8 lists the EIA/TIA-449 DTE pinout, and Table B-9 lists the EIA/TIA-449 cable assembly DCE pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.


Figure B-4: EIA/TIA-449 Cable Assembly


Table  B-8:
EIA/TIA-449 DTE Male Cable Pinout (DB-60-to-DB-37)
60 Pin5 Signal Description Direction 37 Pin Signal
J1-49
J1-48
MODE_1
GND
Shorting group - - -
J1-51
J1-52
GND
MODE_DCE
Shorting group - - -
J1-46 Shield_GND Single _ J2-1 Shield GND
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 6 -->
-->
J2-4
J2-22
SD+
SD-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 9 <--
<--
J2-5
J2-23
ST+
ST-
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 11 <--
<--
J2-6
J2-24
RD+
RD-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 5 -->
-->
J2-7
J2-25
RS+
RS-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 10 <--
<--
J2-8
J2-26
RT+
RT-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1 <--
<--
J2-9
J2-27
CS+
CS-
J1-44
J1-45
LL/DCD
Circuit_GND
Twisted pair no. 12 -->
_
J2-10
J2-37
LL
SC
J1-3
J1-4
DSR/DTR+
DSR/DTR-
Twisted pair no. 2 <--
<--
J2-11
J2-29
DM+
DM-
J1-7
J1-8
DTR/DSR+
DTR/DSR-
Twisted pair no. 4 -->
-->
J2-12
J2-30
TR+
TR-
J1-5
J1-6
DCD/DCD+
DCD/DCD-
Twisted pair no. 3 <--
<--
J2-13
J2-31
RR+
RR-
J1-13
J1-14
TxCE/TxC+
TxCE/TxC-
Twisted pair no. 7 -->
-->
J2-17
J2-35
TT+
TT-
J1-15
J1-16
Circuit_GND
Circuit_GND
Twisted pair no. 9 -
-
J2-19
J2-20
SG
RC

Table  B-9:
EIA/TIA-449 DCE Female Cable Pinout (DB-60-to-DB-37)
60 Pin6 Signal Description Direction 37 Pin Signal
J1-49
J1-48
MODE_1
GND
Shorting group - - -
J1-46 Shield_GND Single - J2-1 Shield GND
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 11 <--
<--
J2-4
J2-22
SD+
SD-
J1-13
J1-14
TxCE/TxC+
TxCE/TxC-
Twisted pair no. 7 -->
-->
J2-5
J2-23
ST+
ST-
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 6 -->
-->
J2-6
J2-24
RD+
RD-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1 <--
<--
J2-7
J2-25
RS+
RS-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 9 -->
-->
J2-8
J2-26
RT+
RT-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 5 -->
-->
J2-9
J2-27
CS+
CS-
J1-29
J1-30
NIL/LL
Circuit_GND
Twisted pair no. 12 -->
-
J2-10
J2-37
LL
SC
J1-7
J1-8
DTR/DSR+
DTR/DSR-
Twisted pair no. 4 -->
-->
J2-11
J2-29
DM+
DM-
J1-3
J1-4
DSR/DTR+
DSR/DTR-
Twisted pair no. 2 <--
<--
J2-12
J2-30
TR+
TR-
J1-5
J1-6
DCD/DCD+
DCD/DCD-
Twisted pair no. 3 -->
-->
J2-13
J2-31
RR+
RR-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 10 <--
<--
J2-17
J2-35
TT+
TT-
J1-15
J1-16
Circuit_GND
Circuit_GND
Twisted pair no. 8 _
_
J2-19
J2-20
SG
RC

V.35 Cables and Pinouts

Figure B-5 shows the V.35 cable assembly. Table B-10 lists the V.35 DTE cable pinout, and Table B-11 lists the V.35 DCE cable pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.


Figure B-5: V.35 Cable Assembly


Table  B-10:
V.35 DTE Male Cable Pinout (DB-60-to-34-Pin)
60 Pin7 Signal Description Direction 34 Pin Signal
J1-49
J1-48
MODE_1
GND
Shorting group - - -
J1-50
J1-51
J1-52
MODE_0
GND
MODE_DCE
Shorting group - - -
J1-53
J1-54
J1-55
J1-56
TxC/NIL
RxC_TxCE
RxD/TxD
GND
Shorting group - - -
J1-46 Shield_GND Single - J2-A Frame GND
J1-45
Shield
Circuit_GND
-
Twisted pair no. 12 -
-
J2-B
Shield
Circuit GND
-
J1-42
Shield
RTS/CTS
-
Twisted pair no. 9 -->
-
J2-C
Shield
RTS
-
J1-35
Shield
CTS/RTS
-
Twisted pair no. 8 <--
-
J2-D
Shield
CTS
-
J1-34
Shield
DSR/DTR
-
Twisted pair no. 7 <--
-
J2-E
Shield
DSR
-
J1-33
Shield
DCD/LL
-
Twisted pair no. 6 <--
-
J2-F
Shield
RLSD
-
J1-43
Shield
DTR/DSR
-
Twisted pair no. 10 -->
-
J2-H
Shield
DTR
-
J1-44
Shield
LL/DCD
-
Twisted pair no. 11 -->
-
J2-K
Shield
LT
-
J1-18
J1-17
TxD/RxD+
TxD/RxD-
Twisted pair no. 1 -->
-->
J2-P
J2-S
SD+
SD-
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 5 <--
<--
J2-R
J2-T
RD+
RD-
J1-20
J1-19
TxCE/TxC+
TxCE/TxC-
Twisted pair no. 2 -->
-->
J2-U
J2-W
SCTE+
SCTE-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 4 <--
<--
J2-V
J2-X
SCR+
SCR-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 3 <--
<--
J2-Y
J2-AA
SCT+
SCT-

Table  B-11:
V.35 DCE Female Cable Pinout (DB-60-to-34-Pin)
60 Pin8 Signal Description Direction 34 Pin Signal
J1-49
J1-48
MODE_1
GND
Shorting group - - -
J1-50
J1-51
MODE_0
GND
Shorting Group - - -
J1-53
J1-54
J1-55
J1-56
TxC/NIL
RxC_TxCE
RxD/TxD
GND
Shorting Group - - -
J1-46 Shield_GND Single - J2-A Frame GND
J1-45
Shield
Circuit_GND
-
Twisted pair no. 12 -
-
J2-B
Shield
Circuit GND
-
J1-35
Shield
CTS/RTS
-
Twisted pair no. 8 <--
-
J2-C
Shield
RTS
-
J1-42
Shield
RTS/CTS
-
Twisted pair no. 9 -->
-
J2-D
Shield
CTS
-
J1-43
Shield
DTR/DSR
-
Twisted pair no. 10 -->
-
J2-E
Shield
DSR
-
J1-44
Shield
LL/DCD
-
Twisted pair no. 11 -->
-
J2-F
Shield
RLSD
-
J1-34
Shield
DSR/DTR
-
Twisted pair no. 7 <--
-
J2-H
Shield
DTR
-
J1-33
Shield
DCD/LL
-
Twisted pair no. 6 <--
-
J2-K
Shield
LT
-
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 5 <--
<--
J2-P
J2-S
SD+
SD-
J1-18
J1-17
TxD/RxD+
TxD/RxD-
Twisted pair no. 1 -->
-->
J2-R
J2-T
RD+
RD-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 4 <--
<--
J2-U
J2-W
SCTE+
SCTE-
J1-22
J1-21
NIL/RxC+
NIL/RxC-
Twisted pair no. 3 -->
-->
J2-V
J2-X
SCR+
SCR-
J1-20
J1-19
TxCE/TxC+
TxCE/TxC-
Twisted pair no. 2 -->
-->
J2-Y
J2-AA
SCT+
SCT-

X.21 Cables and Pinouts

Figure B-6 shows the X.21 cable assembly. Table B-12 lists the X.21 DTE cable pinout, and Table B-13 lists the X.21 DCE cable pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.


Figure B-6: X.21 Cable Assembly


Table  B-12:
X.21 DTE Male Cable Pinout (DB-60-to-DB-15)
60 Pin9 Signal Description Direction 15 Pin Signal
J1-48
J1-47
GND
MODE_2
Shorting group - - -
J1-51
J1-52
GND
MODE_DCE
Shorting group - - -
J1-46 Shield_GND Single - J2-1 Shield GND
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 3 -->
-->
J2-2
J2-9
Transmit+
Transmit-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 2 -->
-->
J2-3
J2-10
Control+
Control-
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 6 <--
<--
J2-4
J2-11
Receive+
Receive-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1 <--
<--
J2-5
J2-12
Indication+
Indication-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 5 <--
<--
J2-6
J2-13
Timing+
Timing-
J1-15
Shield
Control_GND
-
Twisted pair no. 4 -
-
J2-8
Shield
Control GND
-

Table  B-13:
X.21 DCE Female Cable Pinout (DB-60-to-DB-15)
60 Pin10 Signal Description Direction 15 Pin Signal
J1-48
J1-47
GND
MODE_2
Shorting group - - -
J1-46 Shield_GND Single - J2-1 Shield GND
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 6 <--
<--
J2-2
J2-9
Transmit+
Transmit-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1 <--
<--
J2-3
J2-10
Control+
Control-
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 3 -->
-->
J2-4
J2-11
Receive+
Receive-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 2 -->
-->
J2-5
J2-12
Indication+
Indication-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 4 -->
-->
J2-6
J2-13
Timing+
Timing-
J1-15
Shield
Control_GND
-
Twisted pair no. 5 -
-
J2-8
Shield
Control GND
-

Synchronous Serial Interface Port Pinouts

Table B-14 lists the pinouts for the DB-60 synchronous serial interface port.


Table  B-14: Synchronous Serial Interface Port (DB-60)
60 Pin11 Signal Description
J1-50
J1-51
J1-52
MODE_0
GND
MODE_DCE
Shorting group
J1-46 Shield GND Single
J1-41
Shield
TxD/RxD
-
Twisted pair no. 5
J1-36
Shield
RxD/TxD
-
Twisted pair no. 9
J1-42
Shield
RTS/CTS
-
Twisted pair no. 4
J1-35
Shield
CTS/RTS
-
Twisted pair no. 10
J1-34
Shield
DSR/DTR
-
Twisted pair no. 11
J1-45
Shield
Circuit GND
-
Twisted pair no. 1
J1-33
Shield
DCD/LL
-
Twisted pair no. 12
J1-37
Shield
TxC/NIL
-
Twisted pair no. 8
J1-38
Shield
RxC/TxCE
-
Twisted pair no. 7
J1-44
Shield
LL/DCD
-
Twisted pair no. 2
J1-43
Shield
DTR/DSR
-
Twisted pair no. 3
J1-39
Shield
TxCE/TxC
-
Twisted pair no. 6

Network Management Card Pinout Tables

Table B-15 through Table B-19 list the pinouts for the network management NAC serial, 10BaseT, 10Base5, and 10Base2 ports and the UTP connector.


Table  B-15: Network Management NAC Serial Port (DTE)
8-Position Modular Jack Circuit Function Direction
1 CC Data Set Ready Inbound
2 CF Carrier Detect Inbound
3 CD Data Terminal Ready Outbound
4 AB Signal Ground -
5 BB Receive Data Inbound
6 BA Transmit Data Outbound
7 CB Clear To Send Inbound
8 CA Request To send Outbound

Table  B-16: 10BaseT (RJ-45)
Pin Number IEEE Name Function
1 TD+ Transmit Data +
2 TD- Transmit Data -
3 RD+ Receive Data +
4 Not used
5 Not used
6 RD- Receive Data -
7 Not used
8 Not used

Table  B-17: 10Base5 (DB-15)
Pin Number IEEE Name Function
1 CI-S GND
2 CI-A Collision Detect +
3 DO-A Transmit Data +
4 DI-S GND
5 DI-A Receive Data +
6 VC GND
7 CO-A Not used
8 CO-S GND
9 CI-B Collision Detect -
10 DO-B Transmit Data -
11 DO-S GND
12 DI-B Receive Data -
13 VP +12V
14 VS GND
15 CO-B Not used
Shell PG Protective GND

Table  B-18: 10Base2 (BNC)
Pin Function
Center Signal
Shield Isolated GND

Table  B-19: UTP Connector
8- Position Modular Jack Pin Designation Function
3 B Transmit Data
4 R Receive Common
5 G Receive Data
6 O Transmit Common

T1 NIC Connectors

Table B-20 lists the supported functions and pin assignments for the RJ-48C interface of the T1 span lines.


Table  B-20: RJ-48C Pin Assignments
Pin Function T1 NIC <-> Telco
1 Receive ring <--
2 Receive tip <--
3 None -
4 Tip ring -->
5 Tip tip -->
6-8 None -

Table B-21 lists the supported functions and pin assignments of the T1 NIC EIA/TIA-232 interface.


Table  B-21: Network Management Card Serial Port (DTE)
8-Position Modular Jack Circuit Function Direction
1 CC Data Set Ready Inbound
2 CF Carrier Detect Inbound
3 CD Data Terminal Ready Outbound
4 AB Signal Ground -
5 BB Receive Data Inbound
6 BA Transmit Data Outbound
7 CB Clear To Send Inbound
8 CA Request To Send Outbound

1 Any pin not referenced on a connector is not connected.
2 &&Center&&Any pin not referenced is not connected.
3 &&Center&&Any pin not referenced is not connected.
4 &&Center&&Any pin not referenced is not connected.
5 &&Center&&Any pin not referenced is not connected.
6 &&Center&&Any pin not referenced is not connected.
7 &&Center&&Any pin not referenced is not connected.
8 Any pin not referenced is not connected.
9 Any pin not referenced is not connected.
10 Any pin not referenced is not connected.
11 &&Center&&Any pin not referenced is not connected.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.