This appendix contains technical specifications for the following Cisco Access Server 5100 components:
| Specification | Description |
|---|---|
| Access Server 5100 chassis capacity | Up to 17 front-loaded NACs, and their associated rear-loaded NICs. Two power supplies (both are required) |
| Certification | Complies with FCC Part 15 Class A EMI/RFI requirements; complies with FCC Part 68 for nationwide telephone systems; listed by Underwriters' Laboratories (UL), approved by the Canadian Standards Association (CSA), and is Department of Communications (DOC) certified |
| Power requirements | DC power supply nominal -48 VDC (-42 VDC to -60 VDC) with respect to ground
AC power supply nominal 120 V (90-132 VAC) @ 47-63 Hz, or strap-selectable nominal 240 V (180-264 VAC) |
| Power supply output (maximum) | 330 W 45A @ +5.2V 2A @ -5 V 3.5A @ +12.2V 3.5A @ -12.2V |
| Power supply input (maximum)
| 470W 1604 Btus 4A (DC) 10A (DC) |
| Operating environment | Temperature: 32-104oF (0-40oC) Relative humidity: 0-95% noncondensing |
| Specification | Description |
|---|---|
| Power requirements (maximum) | 4A @ +5 VDC, 6.75W 55 mA @ -5 VDC, 275 mW 50 mA @ +12 VDC, 600 mW 50 mA @ 12 VDC, 600 mW |
| Operating environment | Temperature: 32-104oF (0-40o) Relative humidity: 0-95% noncondensing |
| Dimensions (L x H) | NAC: 12.45 x 6.4" (31.62 x 16.26 cm) NIC: 4.85 x 6.4" (12.32 x 16.26 cm) |
| Certification | Complies with FCC Part 15, UL-listed, CSA-approved |
| Specification | Description |
|---|---|
| Power requirements (maximum) | 1.35A @ +5 VDC, 6.75W 55 mA @ -5 VDC, 275 mW 50 mA @ +12 VDC, 600 mW 50 mA @ 12 VDC, 600 mW |
| Operating environment | Temperature: 32-104oF (0-40oC) Relative humidity: 0-95% noncondensing |
| Dimensions (L x H) | NAC: 12.45 x 6.4" (31.62 x 16.26 cm) NIC: 4.85 x 6.4" (12.32 x 16.26 cm) |
| Certification | Complies with FCC Part 15, UL-listed, CSA-approved |
| Receive sensitivity | -44 dBm +2 dBm |
| Transmit level | -9 dBm maximum |
| Transmitter frequency tolerance | .01% |
| Specification | Description |
|---|---|
| Power requirements | 1.5A @ 5 VDC 0.1 A @ 12 VDC 5W |
| Dimensions (L x H) | NAC: 12.45 x 6.4" (31.62 x 16.26cm) NIC: 4.85 x 6.4" (12.32 x 16.26 cm) |
| Heat | 17 Btus |
| Operating environment | Temperature: 32-104oF (0-40oC) Relative humidity: 0-95% noncondensing |
| Specification | Description |
|---|---|
| Power requirements (maximum) | 3.5A @ +5 VDC 20 mA @ -5 VDC 50 mA @ +12 VDC 50 mA @ -12 VDC |
| Operating environment | Temperature: 32-104oF (0-40oC) Relative humidity: 0-95% noncondensing |
| Dimensions (L x H) | 12.45 x 6.4" (31.62 x 16.26 cm) |
| Certification | Complies with FCC Part 15 Class A, FCC Part 68, UL-listed, CSA-approved, and DOC-certified |
| Specification | Description |
|---|---|
| Power requirements | 1.5A @ +5 VDC 50 mA @ +12 VDC 50 mA @ -12 VDC |
| Operating environment | Temperature: 32-104oF (0-40oC) Relative humidity: 0-95% noncondensing |
| Dimensions (L x H) | 4.85 x 6.4" (12.32 x 16.26 cm) |
| Certification | Complies with FCC Part 15 Class A, FCC Part 68, UL-listed, CSA-approved, and DOC-certified |
|
|