Table  A-1: Chassis and Power Supply Specifications
Specification Description
Access Server 5100 chassis capacity Up to 17 front-loaded NACs, and their associated rear-loaded NICs. Two power supplies (both are required)
Certification Complies with FCC Part 15 Class A EMI/RFI requirements; complies with FCC Part 68 for nationwide telephone systems; listed by Underwriters' Laboratories (UL), approved by the Canadian Standards Association (CSA), and is Department of Communications (DOC) certified
Power requirements DC power supply nominal -48 VDC (-42 VDC to -60 VDC) with respect to ground

AC power supply nominal 120 V (90-132 VAC) @ 47-63 Hz, or strap-selectable nominal 240 V (180-264 VAC)
@ 47-63 Hz

Power supply output (maximum) 330 W
45A @ +5.2V
2A @ -5 V
3.5A @ +12.2V
3.5A @ -12.2V
Power supply input (maximum)

470W
1604 Btus
4A (DC)
10A (DC)
Operating environment Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing

Table  A-2: AS51 NAC and NIC
Specification Description
Power requirements
(maximum)
4A @ +5 VDC, 6.75W
55 mA @ -5 VDC, 275 mW
50 mA @ +12 VDC, 600 mW
50 mA @ 12 VDC, 600 mW
Operating environment Temperature: 32-104oF (0-40o)
Relative humidity: 0-95% noncondensing
Dimensions (L x H) NAC: 12.45 x 6.4" (31.62 x 16.26 cm)
NIC: 4.85 x 6.4" (12.32 x 16.26 cm)
Certification Complies with FCC Part 15, UL-listed, CSA-approved

Table  A-3: Quad Modem NAC and NIC
Specification Description
Power requirements
(maximum)
1.35A @ +5 VDC, 6.75W
55 mA @ -5 VDC, 275 mW
50 mA @ +12 VDC, 600 mW
50 mA @ 12 VDC, 600 mW
Operating environment Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing
Dimensions (L x H) NAC: 12.45 x 6.4" (31.62 x 16.26 cm)
NIC: 4.85 x 6.4" (12.32 x 16.26 cm)
Certification Complies with FCC Part 15, UL-listed, CSA-approved
Receive sensitivity -44 dBm +2 dBm
Transmit level -9 dBm maximum
Transmitter frequency tolerance .01%

Table  A-4: T1 NAC and NIC
Specification Description
Power requirements 1.5A @ 5 VDC
0.1 A @ 12 VDC
5W
Dimensions (L x H) NAC: 12.45 x 6.4" (31.62 x 16.26cm)
NIC: 4.85 x 6.4" (12.32 x 16.26 cm)
Heat 17 Btus
Operating environment Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing

Table  A-5: Network Management NAC
Specification Description
Power requirements (maximum) 3.5A @ +5 VDC
20 mA @ -5 VDC
50 mA @ +12 VDC
50 mA @ -12 VDC
Operating environment Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing
Dimensions (L x H) 12.45 x 6.4" (31.62 x 16.26 cm)
Certification Complies with FCC Part 15 Class A, FCC Part 68, UL-listed, CSA-approved, and DOC-certified

Table  A-6: Network Management Ethernet NIC
Specification Description
Power requirements 1.5A @ +5 VDC
50 mA @ +12 VDC
50 mA @ -12 VDC
Operating environment Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing
Dimensions (L x H) 4.85 x 6.4" (12.32 x 16.26 cm)
Certification Complies with FCC Part 15 Class A, FCC Part 68, UL-listed, CSA-approved, and DOC-certified