This document provides cable specifications for Cisco 3600 series and Cisco 2600 series routers.
Use this document in conjunction with the following publications:
This document includes:
If you prefer to order cables, see your router installation guide.
| Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.
|
| Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten. |
| Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). |
| Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil. |
| Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde. |
| Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo. |
| Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten. |
| Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo. |
| ¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo. |
| Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning. |
Your router comes with a console and auxiliary cable kit, which contains the cable and adapters you need to connect a console terminal (an ASCII terminal or PC running terminal emulation software) or modem to your router. The console and auxiliary cable kit includes the following items:
For console connections, proceed to the "Console Port Signals and Pinouts" section; for modem connections, proceed to the "Auxiliary Port Signals and Pinouts" section.
Use the thin, flat, RJ-45-to-RJ-45 roll-over cable and RJ-45-to-DB-9 female DTE adapter (labeled "TERMINAL") to connect the console port to a PC running terminal emulation software. Figure 1 shows how to connect the console port to a PC. Table 1 lists the pinouts for the asynchronous serial console port, the RJ-45-to-RJ-45 rollover cable, and the RJ-45-to-DB-9 female DTE adapter (labeled TERMINAL).

| Console Port (DTE) | RJ-45-to-RJ-45 Rollover Cable | RJ-45-to-DB-9 Terminal Adapter (connected to Rollover Cable) | Console Device | |
|---|---|---|---|---|
| Signal | RJ-45 Pin | RJ-45 Pin | DB-9 Pin | Signal |
RTS | 11 | 8 | 8 | CTS |
DTR | 2 | 7 | 6 | DSR |
TxD | 3 | 6 | 2 | RxD |
GND | 4 | 5 | 5 | GND |
GND | 5 | 4 | 5 | GND |
RxD | 6 | 3 | 3 | TxD |
DSR | 7 | 2 | 4 | DTR |
CTS | 81 | 1 | 7 | RTS |
| 1Pin 1 is connected internally to pin 8 |
Table 2 lists the pinouts for the asynchronous serial console port, the RJ-45-to-RJ-45 rollover cable, and the RJ-45-to-DB-25 female DTE adapter (labeled TERMINAL).
| Console Port (DTE)1 | RJ-45-to-RJ-45 Rollover Cable | RJ-45-to-DB-25 Terminal Adapter | Console Device | |
|---|---|---|---|---|
| Signal | RJ-45 Pin | RJ-45 Pin | DB-25 Pin | Signal |
RTS | 12 | 8 | 5 | CTS |
DTR | 2 | 7 | 6 | DSR |
TxD | 3 | 6 | 3 | RxD |
GND | 4 | 5 | 7 | GND |
GND | 5 | 4 | 7 | GND |
RxD | 6 | 3 | 2 | TxD |
DSR | 7 | 2 | 20 | DTR |
CTS | 81 | 1 | 4 | RTS |
| 1You can use the same cabling to connect a console to the auxiliary port 2Pin 1 is connected internally to pin 8 |
Table 3 lists the pinouts for the asynchronous serial auxiliary port, the RJ-45-to-RJ-45 rollover cable, and the RJ-45-to-DB-25 male DCE adapter (labeled MODEM).
| Auxiliary Port (DTE) | RJ-45-to-RJ-45 Roll-Over Cable | RJ-45-to-DB-25 Modem Adapter | Modem | |
|---|---|---|---|---|
| Signal | RJ-45 Pin | RJ-45 Pin | DB-25 Pin | Signal |
RTS | 11 | 8 | 4 | RTS |
DTR | 2 | 7 | 20 | DTR |
TxD | 3 | 6 | 3 | TxD |
GND | 4 | 5 | 7 | GND |
GND | 5 | 4 | 7 | GND |
RxD | 6 | 3 | 2 | RxD |
DSR | 7 | 2 | 8 | DCD |
CTS | 81 | 1 | 5 | CTS |
| 1Pin 1 is connected internally to pin 8. |
You can identify a rollover cable by comparing the modular plugs at the two ends of the cable. When you hold the plugs side by side, with the tab at the back, the wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug. (See Figure 2.) If you purchased your cable from Cisco Systems, pin 1 is white on one connector, and pin 8 is white on the other (a rollover cable connects pins 1 and 8, 2 and 7, 3 and 6, and 4 and 5).

This section describes the following:
Figure 3 shows the Ethernet (AUI) cable assembly and Table 4 lists the pinouts.

| Pin | Ethernet Circuit | Signal Name |
|---|---|---|
3 | DO-A | Data Out Circuit A |
10 | DO-B | Data Out Circuit B |
11 | DO-S | Data Out Circuit Shield |
5 | DI-A | Data In Circuit A |
12 | DI-B | Data In Circuit B |
4 | DI-S | Data In Circuit Shield |
7 | CO-A | Control Out Circuit A (not connected) |
15 | CO-B | Control Out Circuit B (not connected) |
8 | CO-S | Control Out Circuit Shield (not connected) |
2 | CI-A | Control In Circuit A |
9 | CI-B | Control In Circuit B |
1 | CI-S | Control In Circuit Shield |
6 | VC | Voltage Common |
13 | VP | Voltage Plus |
14 | VS | Voltage Shield (L25 and M25) |
Shell | PG | Protective Ground |
Figure 4 shows the 10BaseT connector (RJ-45) and Table 5 lists its pinouts.

| Pin1 | Description |
|---|---|
1 | TX+ |
2 | TX- |
3 | RX+ |
4 | - |
5 | - |
6 | RX- |
7 | - |
8 | - |
| 1Any pin not described is not connected |
This section illustrates the Fast Ethernet 100BaseTX (RJ-45) connector and lists its pinout and signal descriptions.
Figure 5 shows the 100BaseTX RJ-45 connector, and Table 6 lists its pinout. The 1-port Fast Ethernet network module RJ-45 port actively terminates wire pair 4 and 5 and wire pair 7 and 8. Common-mode termination reduces electromagnetic interference (EMI) and susceptibility to common-mode sources.

| Pin | Signal |
|---|---|
1 | TX+ |
2 | TX- |
3 | RX+ |
6 | RX- |
The 1E1R 2-slot module provides both UTP and STP Token Ring connections described in:
The IEEE has established Token Ring as standard IEEE 802.5. The distance limitations for the IEEE 802.5 specification indicate a maximum segment distance of 328 feet (100 meters) for UTP cabling. The distance limitation is 1,640 feet (500 meters) for STP cabling.
Token Ring can operate at two different ring speeds: 4 and 16 Mbps. All devices on the ring must use the same operating speed.
Only one Token Ring port can be used at a time. The module will automatically detect which port, STP or UTP, is in use. Use the provided Token Ring cable to connect the router to a switch.
Table 7 shows the Token Ring STP port pinouts used by the 1E1R 2-slot module.
| 9-Pin | Signal Name |
|---|---|
1 | RX- |
2 | Ground |
3 | +5 Volt, fused |
4 | Ground |
5 | TX- |
6 | +RX |
7 | Ground |
8 | Ground |
9 | +TX |
Table 8 shows the Token Ring UTP port pinouts used by the 1E1R 2-slot module.
| RJ-45 Pins | Signal |
|---|---|
1 | GND |
2 | GND |
3 | TX |
4 | RX |
5 | TX |
6 | RX |
7 | GND |
8 | - |
This section contains the following topics:
Use a BRI cable (not included) to connect the BRI WAN interface card directly to an ISDN. Table 9 lists the specifications for ISDN BRI cables.
| Specification | High-Capacitance Cable | Low-Capacitance Cable |
|---|---|---|
Resistance (at 96 kHz) | 160 ohms/km | 160 ohms/km |
Capacitance (at 1 kHz) | 120 nF1/km | 30 nF/km |
Impedance (at 96 kHz) | 75 ohms | 150 ohms |
Wire diameter | 0.024" (0.6 mm) | 0.024" (0.6 mm) |
Distance limitation | 32.8' (10 m) | 32.8' (10 m) |
| 1nF=nanoFarad |
Table 10 lists the connector signals and pinouts for the ISDN BRI S/T card. Table 11 lists the connector signals and pinouts for the ISDN BRI U card.
![]() | Caution To prevent damage to the system, make certain you connect the BRI cable to the BRI connector only and not to any other RJ-45 connector. |
| 8 Pin1 | TE2 | NT3 | Polarity |
|---|---|---|---|
3 | TX | RX | + |
4 | RX | TX | + |
5 | RX | TX | - |
6 | TX | RX | - |
| 8 Pin1 | Function |
|---|---|
3 | No connection |
4 | Signal--Tip or Ring |
5 | Signal--Tip or Ring |
6 | No connection |
| 1Pins 1, 2, 7, and 8 are not used. |
Two standard T1 serial cables are available for the CT1/PRI module: null-modem and straight-through. A straight-through cable connects the router to an external CSU. Null-modem cables are used for back-to-back operation and testing.
The T1 interface cable has two 15-pin DB connectors at each end to connect the CT1/PRI with the external T1 CSU. Figure 6 shows the T1 interface cable, connectors, and pinouts. Table 12 lists the pinouts for the null-modem T1 cable and Table 13 lists the pinouts for the straight-through T1 cable.

| 15-Pin DB Connector | 15-Pin DB Connector | ||
|---|---|---|---|
| Signal | Pin | Pin | Signal |
Transmit Tip | 1 | 3 | Receive Tip |
Receive Tip | 3 | 1 | Transmit Tip |
Transmit Ring | 9 | 11 | Receive Ring |
Receive Ring | 11 | 9 | Transmit Ring |
| 15-Pin DB Connector | 15-Pin DB Connector | ||
|---|---|---|---|
| Signal | Pin | Pin | Signal |
Transmit Tip | 1 | 1 | Transmit Tip |
Transmit Ring | 9 | 9 | Transmit Ring |
Receive Tip | 3 | 3 | Receive Tip |
Receive Ring | 11 | 11 | Receive Ring |
Table 14 lists the CT1/PRI-CSU module port pinouts. Use a straight-through RJ-48C-to-RJ-48C cable to connect the T1 port to an RJ-48C jack.
| RJ-48C Pin | Description |
|---|---|
1 | Receive Ring |
2 | Receive Tip |
4 | Ring |
5 | Tip |
This section contains the following topics:
Cisco Systems makes four cables for the CE1/PRI modules. All four have DB-15 connectors on the CE1/PRI end and either BNC, DB-15, Twinax, or RJ-45 connectors on the network end. Figure 7 through Figure 10 show the CE1/PRI interface cables.




Table 15 lists pinouts for the CE1/PRI interface cables.
| CE1/PRI End | Network End | |||||||
|---|---|---|---|---|---|---|---|---|
| DB-15 | BNC | DB-15 | Twinax | RJ-45 | ||||
| Pin | Signal | Signal | Pin | Signal | Pin | Signal | Pin | Signal |
9 | TX Tip | TX Tip | 1 | TX Tip | TX-1 | TX Tip | 1 | TX Tip |
2 | TX Ring | TX Shield | 9 | TX Ring | TX-2 | TX Ring | 2 | TX Ring |
10 | TX Shield | - | 2 | TX Shield | Shield | TX Shield | 3 | TX Shield |
8 | RX Tip | RX Tip | 3 | RX Tip | RX-1 | RX Tip | 4 | RX Tip |
15 | RX Ring | RX Shield | 11 | RX Ring | RX-2 | RX Ring | 5 | RX Ring |
7 | RX Shield | - | 4 | RX Shield | Shield | RX Shield | 6 | RX Shield |
Switched 56-kbps connections are provided by the 56-kbps DSU/CSU WAN interface card. For more information, see the publication Network Modules Hardware Installation Guide.
Table 16 lists the 56/64-kbps DSU/CSU connector signals and pinouts.
| 8 Pin1 | Description |
|---|---|
1 | Transmit Ring |
2 | Transmit Tip |
7 | Receive Tip |
8 | Receive Ring |
| 1Pins 3, 4, 5, and 6 are not used. |
Figure 11 shows the RJ-48 connector wiring for the T1/E1 trunk cable and the digital voice port cable; Table 17 lists the pinouts.

| Pin1 | Signal |
|---|---|
1 | RX (input) |
2 | RX (input) |
3 | - |
4 | TX (output) |
5 | TX (output) |
6 | - |
7 | - |
8 | - |
| 1Any pin not referenced on a connector is not connected. |
This section provides information about the 1-port serial WAN interface card. With the appropriate serial transition cable, this card can provide an EIA/TIA-232, EIA/TIA-449, V.35, X.21, DTE/DCE, EIA-530 DTE, or NRZ/NRZI serial interface.
Six types of serial cables (also called serial adapter cables or serial transition cables) are available from Cisco Systems:
All serial cables provide a universal plug at the interface card end. The network end of each cable provides the physical connectors most commonly used for the interface. For example, the network end of the EIA/TIA-232 serial cable is a DB-25 connector, the most widely used EIA/TIA-232 connector.
After you install the serial WAN interface card, use the appropriate serial cable to connect the interface card's DB-60 serial port to one of the following types of equipment:
This section contains the following topics:
EIA/TIA-232 supports unbalanced circuits at signal speeds up to 64 kbps. The network end of the adapter cable is a standard 25-pin D-shell connector known as a DB-25. (See Figure 12.) The router console and auxiliary ports also use EIA/TIA-232 connections; however, the serial module ports support synchronous connections, and the console and auxiliary ports support asynchronous connections.

Figure 13 shows the EIA/TIA-232 serial cable assembly. Table 18 lists the DTE pinout and Table 19 lists the DCE pinout. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.

| 60-Pin | Signal | Note | Direction | 25-Pin | Signal |
|---|---|---|---|---|---|
J1-50 | MODE_0 | Shorting group | - | - | - |
J1-46 | Shield GND | Single | - | J2-1 | Shield GND |
J1-46 | Shield GND | Single | - | J2-1 | Shield GND |
J1-41 | TXD/RXD | Twisted pair no. 5 | --> | J2-2 | TXD |
J1-36 | RXD/TXD | Twisted pair no. 9 | <-- | J2-3 | RXD |
J1-42 | RTS/CTS | Twisted pair no. 4 | --> | J2-4 | RTS |
J1-35 | CTS/RTS | Twisted pair no. 10 | <-- | J2-5 | CTS |
J1-34 | DSR/DTR | Twisted pair no. 11 | <-- | J2-6 | DSR |
J1-45 | Circuit GND | Twisted pair no. 1 | - | J2-7 | Circuit GND |
J1-33 | DCD/LL | Twisted pair no. 12 | <-- | J2-8 | DCD |
J1-37 | TXC/NIL | Twisted pair no. 8 | <-- | J2-15 | TXC |
J1-38 | RXC/TXCE | Twisted pair no. 7 | <-- | J2-17 | RXC |
J1-44 | LL/DCD | Twisted pair no. 2 | --> | J2-18 | LTST |
J1-43 | DTR/DSR | Twisted pair no. 3 | --> | J2-20 | DTR |
J1-39 | TXCE/TXC | Twisted pair no. 6 | --> | J2-24 | TXCE |
| 60-Pin | Signal | Note | Direction | 25-Pin | Signal |
|---|---|---|---|---|---|
J1-50 | MODE_0 | Shorting group | - | - | - |
J1-36 | RXD/TXD | Twisted pair no. 9 | <-- | J2-2 | TXD |
J1-41 | TXD/RXD | Twisted pair no. 5 | --> | J2-3 | RXD |
J1-35 | CTS/RTS | Twisted pair no. 10 | <-- | J2-4 | RTS |
J1-42 | RTS/CTS | Twisted pair no. 4 | --> | J2-5 | CTS |
J1-43 | DTR/DSR | Twisted pair no. 3 | --> | J2-6 | DSR |
J1-45 | Circuit GND | Twisted pair no. 1 | - | J2-7 | Circuit GND |
J1-44 | LL/DCD | Twisted pair no. 2 | --> | J2-8 | DCD |
J1-39 | TXCE/TXC | Twisted pair no. 7 | --> | J2-15 | TXC |
J1-40 | NIL/RXC | Twisted pair no. 6 | --> | J2-17 | RXC |
J1-33 | DCD/LL | Twisted pair no. 12 | <-- | J2-18 | LTST |
J1-34 | DSR/DTR | Twisted pair no. 11 | <-- | J2-20 | DTR |
J1-38 | RXC/TXCE | Twisted pair no. 8 | <-- | J2-24 | TXCE |
This section contains the following topics:
EIA/TIA-449, which supports balanced (EIA/TIA-422) and unbalanced (EIA/TIA-423) transmissions, is a faster (up to 2 Mbps) version of EIA/TIA-232 that provides more functions and supports transmissions over greater distances.
The EIA/TIA-449 standard was intended to replace the EIA/TIA-232 standard, but it was not widely adopted primarily because of the large installed base of DB-25 hardware and because of the larger size of the 37-pin EIA/TIA-449 connectors, which limited the number of connections possible (fewer than possible with the smaller, 25-pin EIA/TIA-232 connector).
The network end of the EIA/TIA-449 adapter cable provides a standard 37-pin D-shell connector. (See Figure 14.) EIA/TIA-449 cables are available as either DTE (DB-37 plug) or DCE (DB-37 receptacle).

Figure 15 shows the EIA/TIA-449 serial cable assembly. Table 20 lists the DTE pinout and Table 21 lists the DCE pinout. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.

| 60-Pin | Signal Name | Note | Direction | 37-Pin | Signal Name |
|---|---|---|---|---|---|
J1-49 | MODE_1 | Shorting group | - | - | - |
J1-51 | GND | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | _ | J2-1 | Shield GND |
J1-11 | TXD/RXD+ | Twisted pair no. 6 | --> | J2-4 | SD+ |
J1-24 | TXC/RXC+ | Twisted pair no. 9 | <-- | J2-5 | ST+ |
J1-28 | RXD/TXD+ | Twisted pair no. 11 | <-- | J2-6 | RD+ |
J1-9 | RTS/CTS+ | Twisted pair no. 5 | --> | J2-7 | RS+ |
J1-26 | RXC/TXCE+ | Twisted pair no. 10 | <-- | J2-8 | RT+ |
J1-1 | CTS/RTS+ | Twisted pair no. 1 | <-- | J2-9 | CS+ |
J1-44 | LL/DCD | Twisted pair no. 12 | --> | J2-10 | LL |
J1-3 | DSR/DTR+ | Twisted pair no. 2 | <-- | J2-11 | DM+ |
J1-7 | DTR/DSR+ | Twisted pair no. 4 | --> | J2-12 | TR+ |
J1-5 | DCD/DCD+ | Twisted pair no. 3 | <-- | J2-13 | RR+ |
J1-13 | TXCE/TXC+ | Twisted pair no. 7 | --> | J2-17 | TT+ |
J1-15 | Circuit_GND | Twisted pair no. 9 | - | J2-19 | SG |
| 60-Pin | Signal Name | Note | Direction | 37-Pin | Signal Name |
|---|---|---|---|---|---|
J1-49 | MODE_1 | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
J1-28 | RXD/TXD+ | Twisted pair no. 11 | <-- | J2-4 | SD+ |
J1-13 | TXCE/TXC+ | Twisted pair no. 7 | --> | J2-5 | ST+ |
J1-11 | TXD/RXD+ | Twisted pair no. 6 | --> | J2-6 | RD+ |
J1-1 | CTS/RTS+ | Twisted pair no. 1 | <-- | J2-7 | RS+ |
J1-24 | TXC/RXC+ | Twisted pair no. 9 | --> | J2-8 | RT+ |
J1-9 | RTS/CTS+ | Twisted pair no. 5 | --> | J2-9 | CS+ |
J1-29 | NIL/LL | Twisted pair no. 12 | --> | J2-10 | LL |
J1-7 | DTR/DSR+ | Twisted pair no. 4 | --> | J2-11 | DM+ |
J1-3 | DSR/DTR+ | Twisted pair no. 2 | <-- | J2-12 | TR+ |
J1-5 | DCD/DCD+ | Twisted pair no. 3 | --> | J2-13 | RR+ |
J1-26 | RXC/TXCE+ | Twisted pair no. 10 | <-- | J2-17 | TT+ |
J1-15 | Circuit_GND | Twisted pair no. 8 | _ | J2-19 | SG |
This section contains the following topics:
The V.35 interface is recommended for speeds up to 48 kbps, although in practice it is used successfully at 4 Mbps.
The network end of the V.35 adapter cable provides a standard 34-pin Winchester-type connector. (See Figure 16.) V.35 cables are available with a standard V.35 plug or receptacle in either DTE or DCE mode.

Figure 17 shows the V.35 serial cable assembly. Table 22 lists the DTE pinout and Table 23 lists the DCE pinout. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.

| 60-Pin | Signal Name | Type | Direction | 34-Pin | Signal Name |
|---|---|---|---|---|---|
J1-49 | MODE_1 | Shorting group | - | - | - |
J1-50 | MODE_0 | Shorting group | - | - | - |
J1-53 | TxC/NIL | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-A | Frame GND |
J1-45 | Circuit_GND | Twisted pair no. 12 | - | J2-B | Circuit GND |
J1-42 | RTS/CTS | Twisted pair no. 9 | --> | J2-C | RTS |
J1-35 | CTS/RTS | Twisted pair no. 8 | <-- | J2-D | CTS |
J1-34 | DSR/DTR | Twisted pair no. 7 | <-- | J2-E | DSR |
J1-33 | DCD/LL | Twisted pair no. 6 | <-- | J2-F | RLSD |
J1-43 | DTR/DSR | Twisted pair no. 10 | --> | J2-H | DTR |
J1-44 | LL/DCD | Twisted pair no. 11 | --> | J2-K | LT |
J1-18 | TxD/RxD+ | Twisted pair no. 1 | --> | J2-P | SD+ |
J1-28 | RxD/TxD+ | Twisted pair no. 5 | <-- | J2-R | RD+ |
J1-20 | TxCE/TxC+ | Twisted pair no. 2 | --> | J2-U | SCTE+ |
J1-26 | RxC/TxCE+ | Twisted pair no. 4 | <-- | J2-V | SCR+ |
J1-24 | TxC/RxC+ | Twisted pair no. 3 | <-- | J2-Y | SCT+ |
| 60-Pin | Signal Name | Type | Direction | 34-Pin | Signal Name |
|---|---|---|---|---|---|
J1-49 | MODE_1 | Shorting group | - | - | - |
J1-50 | MODE_0 | Shorting group | - | - | - |
J1-53 | TxC/NIL | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-A | Frame GND |
J1-45 | Circuit_GND | Twisted pair no. 12 | - | J2-B | Circuit GND |
J1-35 | CTS/RTS | Twisted pair no. 8 | <-- | J2-C | RTS |
J1-42 | RTS/CTS | Twisted pair no. 9 | --> | J2-D | CTS |
J1-43 | DTR/DSR | Twisted pair no. 10 | --> | J2-E | DSR |
J1-44 | LL/DCD | Twisted pair no. 11 | --> | J2-F | RLSD |
J1-34 | DSR/DTR | Twisted pair no. 7 | <-- | J2-H | DTR |
J1-33 | DCD/LL | Twisted pair no. 6 | <-- | J2-K | LT |
J1-28 | RxD/TxD+ | Twisted pair no. 5 | <-- | J2-P | SD+ |
J1-18 | TxD/RxD+ | Twisted pair no. 1 | --> | J2-R | RD+ |
J1-26 | RxC/TxCE+ | Twisted pair no. 4 | <-- | J2-U | SCTE+ |
J1-22 | NIL/RxC+ | Twisted pair no. 3 | --> | J2-V | SCR+ |
J1-20 | TxCE/TxC+ | Twisted pair no. 2 | --> | J2-Y | SCT+ |
This section contains the following topics:
The network end of the X.21 adapter cable is a standard DB-15 connector. (See Figure 18.) X.21 cables are available as either DTE (DB-15 plug) or DCE (DB-15 receptacle).

Figure 19 shows the X.21 serial cable assembly. Table 24 lists the DTE pinout and Table 25 lists the DCE pinout. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.

| 60-Pin | Signal Name | Type | Direction | 15-Pin | Signal Name |
|---|---|---|---|---|---|
J1-48 | GND | Shorting group | - | - | - |
J1-51 | GND | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
J1-11 | TXD/RXD+ | Twisted pair no. 3 | --> | J2-2 | Transmit+ |
J1-9 | RTS/CTS+ | Twisted pair no. 2 | --> | J2-3 | Control+ |
J1-28 | RXD/TXD+ | Twisted pair no. 6 | <-- | J2-4 | Receive+ |
J1-1 | CTS/RTS+ | Twisted pair no. 1 | <-- | J2-5 | Indication+ |
J1-26 | RXC/TXCE+ | Twisted pair no. 5 | <-- | J2-6 | Timing+ |
J1-15 | Control_GND | Twisted pair no. 4 | - | J2-8 | Control GND |
| 60 Pin | Signal Name | Type | Direction | 15 Pin | Signal Name |
|---|---|---|---|---|---|
J1-48 | GND | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
J1-28 | RXD/TXD+ | Twisted pair no. 6 | <-- | J2-2 | Transmit+ |
J1-1 | CTS/RTS+ | Twisted pair no. 1 | <-- | J2-3 | Control+ |
J1-11 | TXD/RXD+ | Twisted pair no. 3 | --> | J2-4 | Receive+ |
J1-9 | RTS/CTS+ | Twisted pair no. 2 | --> | J2-5 | Indication+ |
J1-24 | TXC/RXC+ | Twisted pair no. 4 | --> | J2-6 | Timing+ |
J1-15 | Control_GND | Twisted pair no. 5 | - | J2-8 | Control GND |
This section contains the following topics:
The EIA-530 adapter cable is available in DTE mode only. The network end of the EIA-530 adapter cable is a standard DB-25 plug commonly used for EIA/TIA-232 connections. Figure 20 shows the DB-25 connector at the network end of the adapter cable.

Figure 21 shows the EIA-530 serial cable assembly, and Table 26 lists the pinout. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.
The EIA-530 interface cannot be operated in DCE mode, and no DCE cable is available for it.

| 60-Pin | Signal Name | 25-Pin | Signal Name | Direction |
|---|---|---|---|---|
J1-11 | TXD/RXD+ | J2-2 | BA(A), TXD+ | --> |
J1-28 | RXD/TXD+ | J2-3 | BB(A), RXD+ | <-- |
J1-9 | RTS/CTS+ | J2-4 | CA(A), RTS+ | --> |
J1-1 | CTS/RTS+ | J2-5 | CB(A), CTS+ | <-- |
J1-3 | DSR/DTR+ | J2-6 | CC(A), DSR+ | <-- |
J1-46 | Shield_GND | J2-1 | Shield | Shorted |
J1-48 | GND | - | - | Shorted |
J1-5 | DCD/DCD+ | J2-8 | CF(A), DCD+ | <-- |
J1-24 | TXC/RXC+ | J2-15 | DB(A), TXC+ | <-- |
J1-26 | RXC/TXCE+ | J2-17 | DD(A), RXC+ | <-- |
J1-44 | LL/DCD | J2-18 | LL | --> |
J1-7 | DTR/DSR+ | J2-20 | CD(A), DTR+ | --> |
J1-13 | TXCE/TXC+ | J2-24 | DA(A), TXCE+ | --> |
J1-51 | GND | - | - | Shorted |
The Smart Serial cable interface supports two independent serial interface ports. Each port supports six types of serial interfaces: EIA/TIA-232, EIA/TIA-449, X.21, V.35 in both DTE and DCE modes, and EIA530/EIA530A in DTE mode. The serial end of the Smart Serial cable is a 26-pin connector. These cables are used with the 2-port serial and 2-port asynchronous/synchronous WAN interface cards.
Figure 22 shows the serial transition cables you can connect to the DB-60 port on the asynchronous/synchronous serial modules and serial WAN interface card.

Table 27 lists the DCE pinout and Table 28 lists the DTE pinout for the EIA/TIA-232 Smart Serial cable. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.
| 26-Pin | Signal Name | Note | Direction | DB-25 Pin | Signal Name |
|---|---|---|---|---|---|
J1-23 | MODE_0 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-05 | I_RXD/TXD+ | Twisted pair no. 9 | <-- | J2-02 | RXD |
J1-01 | O_TXD/RXD+ | Twisted pair no. 5 | --> | J2-03 | TXD |
J1-11 | I_CTS/RTS+ | Twisted pair no. 2 | <-- | J2-04 | CTS |
J1-08 | O_RTS/CTS | Twisted pair no. 4 | --> | J2-05 | RTS |
J1-06 | B_DCD/DCD+ | Twisted pair no. 1 | <-- | J2-08 | DCD |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-15 | TXC |
J1-02 | O_TXCE/RXC+ | Twisted pair no. 6 | --> | J2-24 | TXCE |
J1-13 | B_LL/LL+ | Twisted pair no. 3 | --> | J2-18 | LTST |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 8 | <-- | J2-17 | RXC |
| 26-Pin | Signal Name | Note | Direction | DB-25 Pin | Signal Name |
|---|---|---|---|---|---|
J1-23 | MODE_0 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-05 | I_RXD/TXD+ | Twisted pair no. 5 | <-- | J2-02 | TXD |
J1-01 | O_TXD/RXD+ | Twisted pair no. 9 | --> | J2-03 | RXD |
J1-11 | I_CTS/RTS+ | Twisted pair no. 2 | <-- | J2-04 | RTS |
J1-08 | O_RTS/CTS | Twisted pair no. 4 | --> | J2-05 | CTS |
J1-06 | B_DCD/DCD+ | Twisted pair no. 1 | --> | J2-08 | DCD |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | --> | J2-15 | TXC |
J1-02 | O_TXCE/RXC+ | Twisted pair no. 8 | --> | J2-17 | RXC |
J1-13 | B_LL/LL+ | Twisted pair no. 3 | <-- | J2-18 | LTST |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 6 | <-- | J2-24 | TXCE |
Table 29 lists the DTE pinout and Table 30 lists the DCE pinout for the EIA/TIA-449 Smart Serial cable. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.
| 26-Pin | Signal Name | Note | Direction | DB-37 Pin | Signal Name |
|---|---|---|---|---|---|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-22 | MODE_I | Twisted pair no. 2 | -- | J2-19 | SG |
J1-05 | I_RXD/TXD+ | Twisted pair no. 5 | --> | J2-04 | RD+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-05 | ST+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 5 | --> | J2-06 | SD+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 4 | <-- | J2-09 | CS+ |
J1-02 | O_TXCE/RXC+ | Twisted pair no. 6 | --> | J2-17 | TT+ |
J1-08 | O_RTS/CTS | Twisted pair no. 1 | --> | J2-07 | RS+ |
J1-06 | B_DCD/DCD+ | Twisted pair no. 11 | --> | J2-13 | RR+ |
J1-07 | O_DTR/DSR+ | Twisted pair no. 3 | --> | J2-12 | TR+ |
J1-12 | I_DTR/DSR+ | Twisted pair no. 10 | <-- | J2-11 | DM+ |
J1-13 | B_LL/LL+ | Twisted pair no. 12 | --> | J2-10 | LL |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 8 | <-- | J2-08 | RT+ |
| 26-Pin | Signal Name | Note | Direction | DB-37 Pin | Signal Name |
|---|---|---|---|---|---|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-22 | MODE_I | Twisted pair no. 2 | -- | J2-19 | SG |
J1-05 | I_RXD/TXD+ | Twisted pair no. 5 | <-- | J2-04 | SD+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | --> | J2-05 | ST+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 9 | --> | J2-06 | RD+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 1 | <-- | J2-07 | RS+ |
J1-02 | O_TXCE/RXC+ | Twisted pair no. 8 | --> | J2-08 | RT+ |
J1-08 | O_RTS/CTS | Twisted pair no. 4 | --> | J2-09 | CS+ |
J1-06 | B_DCD/DCD+ | Twisted pair no. 11 | --> | J2-13 | RR+ |
J1-07 | O_DTR/DSR+ | Twisted pair no. 10 | --> | J2-11 | DM+ |
J1-12 | I_DTR/DSR+ | Twisted pair no. 3 | <-- | J2-12 | TR+ |
J1-13 | B_LL/LL+ | Twisted pair no. 12 | --> | J2-10 | LL |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 6 | <-- | J2-17 | TT+ |
Table 31 lists the DTE pinout and Table 32 lists the DCE pinout for the X.21 Smart Serial cable. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.
| 26-Pin | Signal Name | Note | Direction | DB-15 Pin | Signal Name |
|---|---|---|---|---|---|
J1-21 | MODE_2 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-05 | I_RXD/TXD+ | Twisted pair no. 8 | <-- | J2-04 | RECEIVE+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 5 | --> | J2-03 | TRANSMIT+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 2 | <-- | J2-05 | INDICATION+ |
J1-08 | O_RTS/CTS | Twisted pair no. 3 | --> | J2-03 | CONTROL+ |
J1-26 | GND+ | Twisted pair no. 1 | -- | J2-08 | CCT GND |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 7 | <-- | J2-06 | TIMING+ |
| Not used | Twisted pair no. 4 |
|
| Not used |
| Not used | Twisted pair no. 6 |
|
| Not used |
| Not used | Twisted pair no. 9 |
|
| Not used |
| 26-Pin | Signal Name | Note | Direction | DB-15 Pin | Signal Name |
|---|---|---|---|---|---|
J1-21 | MODE_2 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-05 | I_RXD/TXD+ | Twisted pair no. 5 | <-- | J2-02 | TRANSMIT+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 8 | --> | J2-04 | RECEIVE+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 3 | <-- | J2-03 | CONTROL+ |
J1-08 | O_RTS/CTS | Twisted pair no. 2 | --> | J2-05 | INDICATION+ |
J1-02 | O_TXCE/RXC+ | Twisted pair no. 7 | --> | J2-06 | TIMING+ |
J1-26 | GND | Twisted pair no. 1 | -- | J2-08 | CCT GND |
| Not used | Twisted pair no. 4 |
|
| Not used |
| Not used | Twisted pair no. 6 |
|
| Not used |
| Not used | Twisted pair no. 9 |
|
| Not used |
Table 33 lists the DTE pinout and Table 34 lists the DCE pinout for the V.35 Smart Serial cable. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.
| 26-Pin | Signal Name | Note | Direction | V.35 Pin | Signal Name |
|---|---|---|---|---|---|
J1-22 | MODE_1 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-A | Shield_GND |
J1-06 | B_DCD/DCD+ | Twisted pair no. 1 | <-- | J2-F | RLSD |
J1-13 | B_LL/LL+ | Twisted pair no. 3 | --> | J2-K | LT |
J1-05 | I_RXD/TXD+ | Twisted pair no. 9 | <-- | J2-R | RD+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 5 | --> | J2-P | SD+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 2 | <-- | J2-D | CTS |
J1-08 | O_RTS/CTS | Twisted pair no. 4 | --> | J2-C | RTS |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 8 | <-- | J2-V | SCR+ |
J1-02 | O_TCXE/RXC+ | Twisted pair no. 6 | --> | J2-U | SCTE+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-Y | SCT+ |
| 26-Pin | Signal Name | Note | Direction | V.35 Pin | Signal Name |
|---|---|---|---|---|---|
J1-22 | MODE_1 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-A | Shield_GND |
J1-06 | B_DCD/DCD+ | Twisted pair no. 1 | --> | J2-F | RLSD |
J1-13 | B_LL/LL+ | Twisted pair no. 3 | --> | J2-K | LT |
J1-05 | I_RXD/TXD+ | Twisted pair no. 5 | <-- | J2-P | SD+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 9 | --> | J2-R | RD+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 4 | <-- | J2-C | RTS |
J1-08 | O_RTS/CTS | Twisted pair no. 2 | --> | J2-D | CTS |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 6 | <-- | J2-U | SCTE+ |
J1-02 | O_TCXE/RXC+ | Twisted pair no. 8 | --> | J2-V | SCR+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | --> | J2-Y | SCT+ |
Table 35 lists the DTE pinout and Table 36 lists the DCE pinout for the EIA-530 Smart Serial cable. Arrows indicate signal direction: --> means DTE to DCE and <-- means DCE to DTE.
| 26-Pin | Signal Name | Note | Direction | DB-25 Pin | Signal Name |
|---|---|---|---|---|---|
J1-21 | MODE_2 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-06 | B_DCD/DCD+ | Twisted pair no. 11 | <-- | J2-08 | CF(A); DCD+ |
J1-13 | B_LL/LL+ | Twisted pair no. 12 | --> | J2-18 | LL |
J1-05 | I_RXD/TXD+ | Twisted pair no. 9 | <-- | J2-03 | BB(A); RXD+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 5 | --> | J2-02 | BA(A); TXD+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 4 | <-- | J2-05 | CB(A); CTS+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-15 | DB(A); TXC+ |
J1-12 | I_DSR/DTR+ | Twisted pair no. 10 | <-- | J2-06 | CC(A); DSR+ |
J1-08 | O_RTS/CTS | Twisted pair no. 1 | --> | J2-04 | CA(A); RTS+ |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 8 | <-- | J2-17 | DD(A); RXC+ |
J1-02 | O_TCXE/RXC+ | Twisted pair no. 6 | --> | J2-24 | DB(A); TXCE+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-15 | DB(A); TXC+ |
J1-07 | O_DTR/DSR+ | Twisted pair no. 3 | --> | J2-20 | CD(A); DTR+ |
| Not used | Twisted pair no. 2 |
|
| Not used |
| 26-Pin | Signal Name | Note | Direction | DB-25 Pin | Signal Name |
|---|---|---|---|---|---|
J1-21 | MODE_2 | Local connections |
|
|
|
Drain wire |
| Shield | -- | J2-01 | Shield_GND |
J1-06 | B_DCD/DCD+ | Twisted pair no. 11 | <-- | J2-08 | CF(A); DCD+ |
J1-13 | B_LL/LL+ | Twisted pair no. 12 | --> | J2-18 | LL |
J1-05 | I_RXD/TXD+ | Twisted pair no. 9 | <-- | J2-03 | BB(A); RXD+ |
J1-01 | O_TXD/RXD+ | Twisted pair no. 5 | --> | J2-02 | BA(A); TXD+ |
J1-11 | I_CTS/RTS+ | Twisted pair no. 4 | <-- | J2-05 | CB(A); CTS+ |
J1-12 | I_DSR/DTR+ | Twisted pair no. 10 | <-- | J2-06 | CC(A); DSR+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-15 | DB(A); TXC+ |
J1-08 | O_RTS/CTS | Twisted pair no. 1 | --> | J2-04 | CA(A); RTS+ |
J1-04 | I_RXC/TXCE+ | Twisted pair no. 8 | <-- | J2-17 | DD(A); RXC+ |
J1-02 | O_TCXE/RXC+ | Twisted pair no. 6 | --> | J2-24 | DB(A); TXCE+ |
J1-03 | B_TXC/TXC+ | Twisted pair no. 7 | <-- | J2-15 | DB(A); TXC+ |
J1-07 | O_DTR/DSR+ | Twisted pair no. 3 | --> | J2-20 | CD(A); DTR+ |
| Not used | Twisted pair no. 2 |
|
| Not used |
![]()
![]()
![]()
![]()
![]()
![]()
![]()