Table C-1 lists the system specifications for Cisco  1600 series routers.


Table C-1: System Specifications
Description Specification

Processor

Motorola MC68360 QUICC (33 MHz)

Dimensions

  • Height

  • Width

  • Depth

2.19 in. (5.56 cm)

11.15 in. (28.32 cm)

8.67 in. (22.02 cm)

Weight

  • Minimum (no WAN interface card installed)

  • Maximum

1.65 LB (0.75 kg)

1.80 LB (0.82 kg)

Power (external)

14 VDC (+  /  - 8%), minimum  1A

Console port

RJ-45 connector

10BaseT port

RJ-45 connector

AUI port

DB-15 connector

Flash memory slot

Flash PC card

Serial port (Cisco  1601)

DB-60 connector

DSU/CSU port (Cisco  1602)

RJ-48S connector

ISDN ports1 (Cisco  1603 and Cisco  1604)

RJ-45 connector

Temperature

32 to 104ºF (0 to 40ºC)

-4 to 149ºF (-20 to 65ºC)

Operating humidity

5 to 95%, noncondensing

1ISDN ports refer to the ISDN S/T and the ISDN U ports.

Cable Pinouts

This section includes the following pinouts:


Table C-2: 10BaseT Port Pinouts
8 Pin1 Description

1

TX+

2

TX-

3

RX+

6

RX-

1Pins 4, 5, 7, and 8 are not used.

Table C-3:
Straight-Through 10BaseT Cable (RJ-45 to RJ-45)
RJ-45
Pin
Signal Direction RJ-45
Pin

1

TX+

--->

1

2

TX-

--->

2

3

RX+

<---

3

4

-

-

4

5

-

-

5

6

RX-

<---

6

7

-

-

7

8

-

-

8

Pinouts

The EIA/TIA-232 console port is configured as data terminal equipment (DTE) and uses an RJ-45 connector. A console cable kit is provided with your router to connect a console (an ASCII terminal or PC running terminal emulation software) to the console port. The console cable kit contains an RJ-45-to-RJ-45 rollover cable and a RJ-45-to-DB-25 female DTE adapter (labeled Terminal). Table C-4 lists the pinouts for the asynchronous serial console port, the RJ-45-to-RJ-45 rollover cable, and the RJ-45-to-DB-25 female DTE adapter.


Table C-4:
Console Port (DTE) RJ-45-to-RJ-45 Roll-Over Cable
Signal RJ-45 Pin RJ-45 Pin DB-9 Pin DB-25 Pin Signal

-

1

8

7

4

-

DTR

2

7

4

20

DSR

TxD

3

6

3

2

RxD

GND

4

5

5

7

GND

GND

5

4

5

7

GND

RxD

6

3

2

3

TxD

DSR

7

2

6

6

DTR

-

8

1

8

5

-

Console Cable and Adapter Pinouts

You can identify a rollover cable by comparing the two modular ends of the cable. (See Figure C-1.) Holding the cables in your hand, side-by-side, with the tab at the back, the wire connected to the pin on the outside of the left connector (pin 1) should be the same color as the pin on the outside of the right connector (pin 8). On Cisco cables, pin 1 is white on one connector, and pin 8 is white on the other connector.


Figure C-1: Identifying a Rollover Cable



Table C-5:
56-kbps DSU/CSU (RJ-48S) Pinouts
8 Pin1 Description

1

Transmit

2

Transmit

7

Receive

8

Receive

1Pins 3, 4, 5, and 6 are not used.

Table C-6:
ISDN BRI S/T Port Pinouts (RJ-45)
8 Pin1 TE2 NT3 Polarity

3

Transmit

Receive

+

4

Receive

Transmit

+

5

Receive

Transmit

-

6

Transmit

Receive

-

1Pins 1, 2, 7, and 8 are not used.
2TE refers to terminal terminating layer  1 aspects of TE1, TA, and NT functional groups. This applies to the Cisco  1603 and the ISDN  BRI S/T WAN interface card.
3NT refers to network terminating layer  1 aspects of NT1 and NT2 functional groups. This applies to the Cisco  1604 ISDN  S/T port.

Table C-7:
ISDN BRI U Port Pinouts (RJ-45)
8 Pin1 Function

3

No connection

4

Signal---Tip or Ring

5

Signal---Tip or Ring

6

No connection

1Pins 1, 2, 7, and 8 are not used.

The serial port on the router uses a universal port, a 60-pin receptacle that supports the following serial interfaces: EIA/TIA-232, EIA/TIA-449, X.21, V.35, and EIA-530. The shielded serial transition cable determines the electrical interface type. The router end of all of the cables is a 60-pin connector.

DTE connectors have a plug connector at the network end. (DCE connectors have a receptacle at the network end.) However, V.35 is available in DTE mode either a receptacle or a plug connector at the network end. The serial port operates in DTE and DCE modes.

The tables that follow list the signal pinouts for the DTE mode serial transition cables for each router interface type.

Figure C-2 shows the EIA/TIA-232 serial cable assembly, and Table C-8 lists the EIA/TIA-232 cable pinouts.


Figure C-2: EIA/TIA-232 Serial Cable Assembly



Table C-8:
EIA/TIA-232 DTE Cable Pinouts (DB-60 to DB-25)
60 Pin1 Signal Description Direction 25 Pin Signal

J1-50
J1-51
J1-52

MODE_0
GND
MODE_DCE

Shorting group

-

-

-

J1-46

Shield GND

Single

-

J2-1

Shield GND

J1-41
Shield

TxD/RxD
-

Twisted pair no. 5

--->
-

J2-2
Shield

TxD
-

J1-36
Shield

RxD/TxD
-

Twisted pair no. 9

<---
-

J2-3
Shield

RxD
-

J1-42
Shield

RTS/CTS
-

Twisted pair no. 4

--->
-

J2-4
Shield

RTS
-

J1-35
Shield

CTS/RTS
-

Twisted pair no. 10

<---
-

J2-5
Shield

CTS
-

J1-34
Shield

DSR/DTR
-

Twisted pair no. 11

<---
-

J2-6
Shield

DSR
-

J1-45
Shield

Circuit GND
-

Twisted pair no. 1

-
-

J2-7
Shield

Circuit GND
-

J1-33
Shield

DCD/LL
-

Twisted pair no. 12

<---
-

J2-8
Shield

DCD
-

J1-37
Shield

TxC/NIL
-

Twisted pair no. 8

<---
-

J2-15
Shield

TxC
-

J1-38
Shield

RxC/TxCE
-

Twisted pair no. 7

<---
-

J2-17
Shield

RxC
-

J1-44
Shield

LL/DCD
-

Twisted pair no. 2

--->
-

J2-18
Shield

LTST
-

J1-43
Shield

DTR/DSR
-

Twisted pair no. 3

--->
-

J2-20
Shield

DTR
-

J1-39
Shield

TxCE/TxC
-

Twisted pair no. 6

--->
-

J2-24
Shield

TxCE
-

1Any pin not referenced is not connected.

Figure C-3:
EIA/TIA-449 Serial Cable Assembly



Table C-9:
EIA/TIA-449 DTE Cable Pinouts (DB-60 to DB-37)
60 Pin1 Signal Description Direction 37 Pin Signal

J1-49
J1-48

MODE_1
GND

Shorting group

-

-

-

J1-51
J1-52

GND
MODE_DCE

Shorting group

-

-

-

J1-46

Shield_GND

Single

_

J2-1

Shield GND

J1-11
J1-12

TxD/RxD+
TxD/RxD-

Twisted pair no. 6

--->
--->

J2-4
J2-22

SD+
SD-

J1-24
J1-23

TxC/RxC+
TxC/RxC-

Twisted pair no. 9

<---
<---

J2-5
J2-23

ST+
ST-

J1-28
J1-27

RxD/TxD+
RxD/TxD-

Twisted pair no. 11

<---
<---

J2-6
J2-24

RD+
RD-

J1-9
J1-10

RTS/CTS+
RTS/CTS-

Twisted pair no. 5

--->
--->

J2-7
J2-25

RS+
RS-

J1-26
J1-25

RxC/TxCE+
RxC/TxCE-

Twisted pair no. 10

<---
<---

J2-8
J2-26

RT+
RT-

J1-1
J1-2

CTS/RTS+
CTS/RTS-

Twisted pair no. 1

<---
<---

J2-9
J2-27

CS+
CS-

J1-44
J1-45

LL/DCD
Circuit_GND

Twisted pair no. 12

--->
_

J2-10
J2-37

LL
SC

J1-3
J1-4

DSR/DTR+
DSR/DTR-

Twisted pair no. 2

<---
<---

J2-11
J2-29

DM+
DM-

J1-7
J1-8

DTR/DSR+
DTR/DSR-

Twisted pair no. 4

--->
--->

J2-12
J2-30

TR+
TR-

J1-5
J1-6

DCD/DCD+
DCD/DCD-

Twisted pair no. 3

<---
<---

J2-13
J2-31

RR+
RR-

J1-13
J1-14

TxCE/TxC+
TxCE/TxC-

Twisted pair no. 7

--->
--->

J2-17
J2-35

TT+
TT-

J1-15
J1-16

Circuit_GND
Circuit_GND

Twisted pair no. 9

-
-

J2-19
J2-20

SG
RC

1Any pin not referenced is not connected.

Figure C-4:
X.21 Cable Assembly



Table C-10:
X.21 DTE Cable Pinouts (DB-60 to DB-15)
60 Pin1 Signal Description Direction 15 Pin Signal

J1-48
J1-47

GND
MODE_2

Shorting group

-

-

-

J1-51
J1-52

GND
MODE_DCE

Shorting group

-

-

-

J1-46

Shield_GND

Single

-

J2-1

Shield GND

J1-11
J1-12

TxD/RxD+
TxD/RxD-

Twisted pair no. 3

--->
--->

J2-2
J2-9

Transmit+
Transmit-

J1-9
J1-10

RTS/CTS+
RTS/CTS-

Twisted pair no. 2

--->
--->

J2-3
J2-10

Control+
Control-

J1-28
J1-27

RxD/TxD+
RxD/TxD-

Twisted pair no. 6

<---
<---

J2-4
J2-11

Receive+
Receive-

J1-1
J1-2

CTS/RTS+
CTS/RTS-

Twisted pair no. 1

<---
<---

J2-5
J2-12

Indication+
Indication-

J1-26
J1-25

RxC/TxCE+
RxC/TxCE-

Twisted pair no. 5

<---
<---

J2-6
J2-13

Timing+
Timing-

J1-15
Shield

Control_GND
-

Twisted pair no. 4

-
-

J2-8
Shield

Control GND
-

1Any pin not referenced is not connected.

Figure C-5:
V.35 Cable Assembly



Table C-11: V.35 Cable Pinouts (DB-60 to 34-Pin)
60 Pin1 Signal Description Direction 34 Pin Signal

J1-49
J1-48

MODE_1
GND

Shorting group

-

-

-

J1-50
J1-51
J1-52

MODE_0
GND
MODE_DCE

Shorting group

-

-

-

J1-53
J1-54
J1-55
J1-56

TxC/NIL
RxC_TxCE
RxD/TxD
GND

Shorting group

-

-

-

J1-46

Shield_GND

Single

-

J2-A

Frame GND

J1-45
Shield

Circuit_GND
-

Twisted pair no. 12

-
-

J2-B
Shield

Circuit GND
-

J1-42
Shield

RTS/CTS
-

Twisted pair no. 9

--->
-

J2-C
Shield

RTS
-

J1-35
Shield

CTS/RTS
-

Twisted pair no. 8

<---
-

J2-D
Shield

CTS
-

J1-34
Shield

DSR/DTR
-

Twisted pair no. 7

<---
-

J2-E
Shield

DSR
-

J1-33
Shield

DCD/LL
-

Twisted pair no. 6

<---
-

J2-F
Shield

RLSD
-

J1-43
Shield

DTR/DSR
-

Twisted pair no. 10

--->
-

J2-H
Shield

DTR
-

J1-44
Shield

LL/DCD
-

Twisted pair no. 11

--->
-

J2-K
Shield

LT
-

J1-18
J1-17

TxD/RxD+
TxD/RxD-

Twisted pair no. 1

--->
--->

J2-P
J2-S

SD+
SD-

J1-28
J1-27

RxD/TxD+
RxD/TxD-

Twisted pair no. 5

<---
<---

J2-R
J2-T

RD+
RD-

J1-20
J1-19

TxCE/TxC+
TxCE/TxC-

Twisted pair no. 2

--->
--->

J2-U
J2-W

SCTE+
SCTE-

J1-26
J1-25

RxC/TxCE+
RxC/TxCE-

Twisted pair no. 4

<---
<---

J2-V
J2-X

SCR+
SCR-

J1-24
J1-23

TxC/RxC+
TxC/RxC-

Twisted pair no. 3

<---
<---

J2-Y
J2-AA

SCT+
SCT-

1Any pin not referenced is not connected.


Figure C-6:
EIA-530 Cable Assembly



Table C-12:
EIA-530 DTE Cable Pinouts (DB-60 to DB-25)

60 Pin1

Signal

25 Pin

Signal
Direction
DTE  DCE2

J1-11
J1-12

TxD/RxD+
TxD/RxD-

J2-2
J2-14

BA(A), TxD+
BA(B), TxD-

--->
--->

J1-28
J1-27

RxD/TxD+
RxD/TxD-

J2-3
J2-16

BB(A), RxD+
BB(B), RxD-

<---
<---

J1-9
J1-10

RTS/CTS+
RTS/CTS-

J2-4
J2-19

CA(A), RTS+
CA(B), RTS-

--->
--->

J1-1
J1-2

CTS/RTS+
CTS/RTS-

J2-5
J2-13

CB(A), CTS+
CB(B), CTS-

<---
<---

J1-3
J1-4

DSR/DTR+
DSR/DTR-

J2-6
J2-22

CC(A), DSR+
CC(B), DSR-

<---
<---

J1-46
J1-47

Shield_GND
MODE_2

J2-1
-

Shield
-

Shorted

J1-48
J1-49

GND
MODE_1

-
-

-
-

Shorted

J1-5
J1-6

DCD/DCD+
DCD/DCD-

J2-8
J2-10

CF(A), DCD+
CF(B), DCD-

<---
<---

J1-24
J1-23

TxC/RxC+
TxC/RxC-

J2-15
J2-12

DB(A), TxC+
DB(B), TxC-

<---
<---

J1-26
J1-25

RxC/TxCE+
RxC/TxCE-

J2-17
J2-9

DD(A), RxC+
DD(B), RxC-

<---
<---

J1-44
J1-45

LL/DCD
Circuit_GND

J2-18
J2-7

LL
Circuit_ GND

--->
-

J1-7
J1-8

DTR/DSR+
DTR/DSR-

J2-20
J2-23

CD(A), DTR+
CD(B), DTR-

--->
--->

J1-13
J1-14

TxCE/TxC+
TxCE/TxC-

J2-24
J2-11

DA(A), TxCE+
DA(B), TxCE-

--->
--->

1Any pin not referenced is not connected.
2The EIA-530 interface cannot be operated in DCE mode. A DCE cable is not available for the EIA-530 interface.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.