This appendix contains the following sections:
Table C-1 lists the system specifications for Cisco 1600 series routers.
| Description | Specification |
|---|---|
Processor | Motorola MC68360 QUICC (33 MHz) |
Dimensions
|
2.19 in. (5.56 cm) 11.15 in. (28.32 cm) 8.67 in. (22.02 cm) |
Weight
|
1.65 LB (0.75 kg) 1.80 LB (0.82 kg) |
14 VDC (+ / - 8%), minimum 1A | |
RJ-45 connector | |
DB-15 connector | |
Flash PC card | |
Serial port (Cisco 1601) | DB-60 connector |
DSU/CSU port (Cisco 1602) | RJ-48S connector |
ISDN ports1 (Cisco 1603 and Cisco 1604) | |
| Temperature |
32 to 104ºF (0 to 40ºC) -4 to 149ºF (-20 to 65ºC) |
5 to 95%, noncondensing |
| 1ISDN ports refer to the ISDN S/T and the ISDN U ports. |
This section includes the following pinouts:
| 8 Pin1 | Description |
|---|---|
1 | TX+ |
2 | TX- |
3 | RX+ |
6 | RX- |
| 1Pins 4, 5, 7, and 8 are not used. |
| RJ-45 Pin | Signal | Direction | RJ-45 Pin |
|---|---|---|---|
1 | TX+ | ---> | 1 |
2 | TX- | ---> | 2 |
3 | RX+ | <--- | 3 |
4 | - | - | 4 |
5 | - | - | 5 |
6 | RX- | <--- | 6 |
7 | - | - | 7 |
8 | - | - | 8 |
The EIA/TIA-232 console port is configured as data terminal equipment (DTE) and uses an RJ-45 connector. A console cable kit is provided with your router to connect a console (an ASCII terminal or PC running terminal emulation software) to the console port. The console cable kit contains an RJ-45-to-RJ-45 rollover cable and a RJ-45-to-DB-25 female DTE adapter (labeled Terminal). Table C-4 lists the pinouts for the asynchronous serial console port, the RJ-45-to-RJ-45 rollover cable, and the RJ-45-to-DB-25 female DTE adapter.
| Console Port (DTE) | RJ-45-to-RJ-45 Roll-Over Cable | ||||
|---|---|---|---|---|---|
| Signal | RJ-45 Pin | RJ-45 Pin | DB-9 Pin | DB-25 Pin | Signal |
- | 1 | 8 | 7 | 4 | - |
DTR | 2 | 7 | 4 | 20 | DSR |
TxD | 3 | 6 | 3 | 2 | RxD |
GND | 4 | 5 | 5 | 7 | GND |
GND | 5 | 4 | 5 | 7 | GND |
RxD | 6 | 3 | 2 | 3 | TxD |
DSR | 7 | 2 | 6 | 6 | DTR |
- | 8 | 1 | 8 | 5 | - |
You can identify a rollover cable by comparing the two modular ends of the cable. (See Figure C-1.) Holding the cables in your hand, side-by-side, with the tab at the back, the wire connected to the pin on the outside of the left connector (pin 1) should be the same color as the pin on the outside of the right connector (pin 8). On Cisco cables, pin 1 is white on one connector, and pin 8 is white on the other connector.

| 8 Pin1 | Description |
|---|---|
1 | Transmit |
2 | Transmit |
7 | Receive |
8 | Receive |
| 1Pins 3, 4, 5, and 6 are not used. |
| 8 Pin1 | TE2 | NT3 | Polarity |
|---|---|---|---|
3 | Transmit | Receive | + |
4 | Receive | Transmit | + |
5 | Receive | Transmit | - |
6 | Transmit | Receive | - |
| 8 Pin1 | Function |
|---|---|
3 | No connection |
4 | Signal---Tip or Ring |
5 | Signal---Tip or Ring |
6 | No connection |
| 1Pins 1, 2, 7, and 8 are not used. |
DTE connectors have a plug connector at the network end. (DCE connectors have a receptacle at the network end.) However, V.35 is available in DTE mode either a receptacle or a plug connector at the network end. The serial port operates in DTE and DCE modes.
The tables that follow list the signal pinouts for the DTE mode serial transition cables for each router interface type.
Figure C-2 shows the EIA/TIA-232 serial cable assembly, and Table C-8 lists the EIA/TIA-232 cable pinouts.

| 60 Pin1 | Signal | Description | Direction | 25 Pin | Signal |
|---|---|---|---|---|---|
J1-50 | MODE_0 | Shorting group | - | - | - |
J1-46 | Shield GND | Single | - | J2-1 | Shield GND |
J1-41 | TxD/RxD | Twisted pair no. 5 | ---> | J2-2 | TxD |
J1-36 | RxD/TxD | Twisted pair no. 9 | <--- | J2-3 | RxD |
J1-42 | RTS/CTS | Twisted pair no. 4 | ---> | J2-4 | RTS |
J1-35 | CTS/RTS | Twisted pair no. 10 | <--- | J2-5 | CTS |
J1-34 | DSR/DTR | Twisted pair no. 11 | <--- | J2-6 | DSR |
J1-45 | Circuit GND | Twisted pair no. 1 | - | J2-7 | Circuit GND |
J1-33 | DCD/LL | Twisted pair no. 12 | <--- | J2-8 | DCD |
J1-37 | TxC/NIL | Twisted pair no. 8 | <--- | J2-15 | TxC |
J1-38 | RxC/TxCE | Twisted pair no. 7 | <--- | J2-17 | RxC |
J1-44 | LL/DCD | Twisted pair no. 2 | ---> | J2-18 | LTST |
J1-43 | DTR/DSR | Twisted pair no. 3 | ---> | J2-20 | DTR |
J1-39 | TxCE/TxC | Twisted pair no. 6 | ---> | J2-24 | TxCE |
| 1Any pin not referenced is not connected. |

| 60 Pin1 | Signal | Description | Direction | 37 Pin | Signal |
|---|---|---|---|---|---|
J1-49 | MODE_1 | Shorting group | - | - | - |
J1-51 | GND | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | _ | J2-1 | Shield GND |
J1-11 | TxD/RxD+ | Twisted pair no. 6 | ---> | J2-4 | SD+ |
J1-24 | TxC/RxC+ | Twisted pair no. 9 | <--- | J2-5 | ST+ |
J1-28 | RxD/TxD+ | Twisted pair no. 11 | <--- | J2-6 | RD+ |
J1-9 | RTS/CTS+ | Twisted pair no. 5 | ---> | J2-7 | RS+ |
J1-26 | RxC/TxCE+ | Twisted pair no. 10 | <--- | J2-8 | RT+ |
J1-1 | CTS/RTS+ | Twisted pair no. 1 | <--- | J2-9 | CS+ |
J1-44 | LL/DCD | Twisted pair no. 12 | ---> | J2-10 | LL |
J1-3 | DSR/DTR+ | Twisted pair no. 2 | <--- | J2-11 | DM+ |
J1-7 | DTR/DSR+ | Twisted pair no. 4 | ---> | J2-12 | TR+ |
J1-5 | DCD/DCD+ | Twisted pair no. 3 | <--- | J2-13 | RR+ |
J1-13 | TxCE/TxC+ | Twisted pair no. 7 | ---> | J2-17 | TT+ |
J1-15 | Circuit_GND | Twisted pair no. 9 | - | J2-19 | SG |
| 1Any pin not referenced is not connected. |

| 60 Pin1 | Signal | Description | Direction | 15 Pin | Signal |
|---|---|---|---|---|---|
J1-48 | GND | Shorting group | - | - | - |
J1-51 | GND | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
J1-11 | TxD/RxD+ | Twisted pair no. 3 | ---> | J2-2 | Transmit+ |
J1-9 | RTS/CTS+ | Twisted pair no. 2 | ---> | J2-3 | Control+ |
J1-28 | RxD/TxD+ | Twisted pair no. 6 | <--- | J2-4 | Receive+ |
J1-1 | CTS/RTS+ | Twisted pair no. 1 | <--- | J2-5 | Indication+ |
J1-26 | RxC/TxCE+ | Twisted pair no. 5 | <--- | J2-6 | Timing+ |
J1-15 | Control_GND | Twisted pair no. 4 | - | J2-8 | Control GND |
| 1Any pin not referenced is not connected. |

| 60 Pin1 | Signal | Description | Direction | 34 Pin | Signal |
|---|---|---|---|---|---|
J1-49 | MODE_1 | Shorting group | - | - | - |
J1-50 | MODE_0 | Shorting group | - | - | - |
J1-53 | TxC/NIL | Shorting group | - | - | - |
J1-46 | Shield_GND | Single | - | J2-A | Frame GND |
J1-45 | Circuit_GND | Twisted pair no. 12 | - | J2-B | Circuit GND |
J1-42 | RTS/CTS | Twisted pair no. 9 | ---> | J2-C | RTS |
J1-35 | CTS/RTS | Twisted pair no. 8 | <--- | J2-D | CTS |
J1-34 | DSR/DTR | Twisted pair no. 7 | <--- | J2-E | DSR |
J1-33 | DCD/LL | Twisted pair no. 6 | <--- | J2-F | RLSD |
J1-43 | DTR/DSR | Twisted pair no. 10 | ---> | J2-H | DTR |
J1-44 | LL/DCD | Twisted pair no. 11 | ---> | J2-K | LT |
J1-18 | TxD/RxD+ | Twisted pair no. 1 | ---> | J2-P | SD+ |
J1-28 | RxD/TxD+ | Twisted pair no. 5 | <--- | J2-R | RD+ |
J1-20 | TxCE/TxC+ | Twisted pair no. 2 | ---> | J2-U | SCTE+ |
J1-26 | RxC/TxCE+ | Twisted pair no. 4 | <--- | J2-V | SCR+ |
J1-24 | TxC/RxC+ | Twisted pair no. 3 | <--- | J2-Y | SCT+ |
| 1Any pin not referenced is not connected. |

60 Pin1 | Signal | 25 Pin | Signal | Direction DTE DCE2 |
|---|---|---|---|---|
J1-11 | TxD/RxD+ | J2-2 | BA(A), TxD+ | ---> |
J1-28 | RxD/TxD+ | J2-3 | BB(A), RxD+ | <--- |
J1-9 | RTS/CTS+ | J2-4 | CA(A), RTS+ | ---> |
J1-1 | CTS/RTS+ | J2-5 | CB(A), CTS+ | <--- |
J1-3 | DSR/DTR+ | J2-6 | CC(A), DSR+ | <--- |
J1-46 | Shield_GND | J2-1 | Shield | Shorted |
J1-48 | GND | - | - | Shorted |
J1-5 | DCD/DCD+ | J2-8 | CF(A), DCD+ | <--- |
J1-24 | TxC/RxC+ | J2-15 | DB(A), TxC+ | <--- |
J1-26 | RxC/TxCE+ | J2-17 | DD(A), RxC+ | <--- |
J1-44 | LL/DCD | J2-18 | LL | ---> |
J1-7 | DTR/DSR+ | J2-20 | CD(A), DTR+ | ---> |
J1-13 | TxCE/TxC+ | J2-24 | DA(A), TxCE+ | ---> |
| 1Any pin not referenced is not connected. 2The EIA-530 interface cannot be operated in DCE mode. A DCE cable is not available for the EIA-530 interface. |
|
|