This appendix provides the following pinout information:
The console port is configured as data communications equipment (DCE), and the auxiliary port is configured as data terminal equipment (DTE). The console and auxiliary ports both use RJ-45 connectors. RJ-45-to-DB-25 adapters are available for connection to modems and other external communications equipment. Both ports are configured as asynchronous serial ports.
Following are the pinouts for the console port (see Table C-1), the auxiliary port (see Table C-2), and the adapter (see Table C-16 and Table C-17).
| Console Port (DTE) | ||
|---|---|---|
| Pin1 | Signal | Input/Output |
| 1 | - | - |
| 2 | DTR | Output |
| 3 | TxD | Output |
| 4 | GND | - |
| 5 | GND | - |
| 6 | RxD | Input |
| 7 | DSR | Input |
| 8 | - | - |
| Auxiliary Port (DTE) | ||
|---|---|---|
| Pin1 | Signal | Input/Output |
| 1 | RTS | Output |
| 2 | DTR | Output |
| 3 | TXD | Output |
| 4 | GND | - |
| 5 | GND | - |
| 6 | RXD | Input |
| 7 | DSR | Input |
| 8 | CTS | Input |
The following illustrations and tables provide assembly drawings and pinouts for the EIA-530 DCE, and EIA/TIA-232, EIA/TIA-449, V.35, and X.21 DTE and DCE cables.
Figure C-1 shows the EIA-530 serial cable assembly, and Table C-3 lists the pinouts. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.

60 Pin1 | Signal | 25 Pin | Signal | Direction DTE DCE1 |
|---|---|---|---|---|
| J1-11 J1-12 | TxD/RxD+ TxD/RxD- | J2-2 J2-14 | BA(A), TxD+ BA(B), TxD- | --> --> |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | J2-3 J2-16 | BB(A), RxD+ BB(B), RxD- | <-- <-- |
| J1-9 J1-10 | RTS/CTS+ RTS/CTS- | J2-4 J2-19 | CA(A), RTS+ CA(B), RTS- | --> --> |
| J1-1 J1-2 | CTS/RTS+ CTS/RTS- | J2-5 J2-13 | CB(A), CTS+ CB(B), CTS- | <-- <-- |
| J1-3 J1-4 | DSR/DTR+ DSR/DTR- | J2-6 J2-22 | CC(A), DSR+ CC(B), DSR- | <-- <-- |
| J1-46 J1-47 | Shield_GND MODE_2 | J2-1 - | Shield - | Shorted |
| J1-48 J1-49 | GND MODE_1 | - - | - - | Shorted |
| J1-5 J1-6 | DCD/DCD+ DCD/DCD- | J2-8 J2-10 | CF(A), DCD+ CF(B), DCD- | <-- <-- |
| J1-24 J1-23 | TxC/RxC+ TxC/RxC- | J2-15 J2-12 | DB(A), TxC+ DB(B), TxC- | <-- <-- |
| J1-26 J1-25 | RxC/TxCE+ RxC/TxCE- | J2-17 J2-9 | DD(A), RxC+ DD(B), RxC- | <-- <-- |
| J1-44 J1-45 | LL/DCD Circuit_GND | J2-18 J2-7 | LL Circuit_ GND | --> - |
| J1-7 J1-8 | DTR/DSR+ DTR/DSR- | J2-20 J2-23 | CD(A), DTR+ CD(B), DTR- | --> --> |
| J1-13 J1-14 | TxCE/TxC+ TxCE/TxC- | J2-24 J2-11 | DA(A), TxCE+ DA(B), TxCE- | --> --> |
Figure C-2 shows the EIA/TIA-232 cable assembly; Table C-4 lists the DTE pinout; and Table C-5 lists the DCE pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.

| 60 Pin2 | Signal | Description | Direction | 25 Pin | Signal |
|---|---|---|---|---|---|
| J1-50 J1-51 J1-52 | MODE_0 GND MODE_DCE | Shorting group | - | - | - |
| J1-46 | Shield GND | Single | - | J2-1 | Shield GND |
| J1-41 Shield | TxD/RxD - | Twisted pair no. 5 | --> - | J2-2 Shield | TxD - |
| J1-36 Shield | RxD/TxD - | Twisted pair no. 9 | <-- - | J2-3 Shield | RxD - |
| J1-42 Shield | RTS/CTS - | Twisted pair no. 4 | --> - | J2-4 Shield | RTS - |
| J1-35 Shield | CTS/RTS - | Twisted pair no. 10 | <-- - | J2-5 Shield | CTS - |
| J1-34 Shield | DSR/DTR - | Twisted pair no. 11 | <-- - | J2-6 Shield | DSR - |
| J1-45 Shield | Circuit GND - | Twisted pair no. 1 | - - | J2-7 Shield | Circuit GND - |
| J1-33 Shield | DCD/LL - | Twisted pair no. 12 | <-- - | J2-8 Shield | DCD - |
| J1-37 Shield | TxC/NIL - | Twisted pair no. 8 | <-- - | J2-15 Shield | TxC - |
| J1-38 Shield | RxC/TxCE - | Twisted pair no. 7 | <-- - | J2-17 Shield | RxC - |
| J1-44 Shield | LL/DCD - | Twisted pair no. 2 | --> - | J2-18 Shield | LTST - |
| J1-43 Shield | DTR/DSR - | Twisted pair no. 3 | --> - | J2-20 Shield | DTR - |
| J1-39 Shield | TxCE/TxC - | Twisted pair no. 6 | --> - | J2-24 Shield | TxCE - |
| 60 Pin3 | Signal | Description | Direction | 25 Pin | Signal |
|---|---|---|---|---|---|
| J1-50 J1-51 | MODE_0 GND | Shorting group | - | - | - |
| J1-46 | Shield GND | Single | - | J2-1 | Shield GND |
| J1-36 Shield | RxD/TxD - | Twisted pair no. 9 | <-- - | J2-2 Shield | TxD - |
| J1-41 Shield | TxD/RxD - | Twisted pair no. 5 | --> - | J2-3 Shield | RxD - |
| J1-35 Shield | CTS/RTS - | Twisted pair no. 10 | <-- - | J2-4 Shield | RTS - |
| J1-42 Shield | RTS/CTS - | Twisted pair no. 4 | --> - | J2-5 Shield | CTS - |
| J1-43 Shield | DTR/DSR - | Twisted pair no. 3 | --> - | J2-6 Shield | DSR - |
| J1-45 Shield | Circuit GND - | Twisted pair no. 1 | - - | J2-7 Shield | Circuit GND |
| J1-44 Shield | LL/DCD - | Twisted pair no. 2 | --> - | J2-8 Shield | DCD - |
| J1-39 Shield | TxCE/TxC - | Twisted pair no. 7 | --> - | J2-15 Shield | TxC - |
| J1-40 Shield | NIL/RxC - | Twisted pair no. 6 | --> - | J2-17 Shield | RxC - |
| J1-33 Shield | DCD/LL - | Twisted pair no. 12 | <-- - | J2-18 Shield | LTST - |
| J1-34 Shield | DSR/DTR - | Twisted pair no. 11 | <-- - | J2-20 Shield | DTR - |
| J1-38 Shield | RxC/TxCE - | Twisted pair no. 8 | <-- - | J2-24 Shield | TxCE - |
Figure C-3 shows the EIA/TIA-449 cable assembly; Table C-6 lists the DTE pinout; Table C-7 lists the DCE pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.

| 60 Pin4 | Signal | Description | Direction | 37 Pin | Signal |
|---|---|---|---|---|---|
| J1-49 J1-48 | MODE_1 GND | Shorting group | - | - | - |
| J1-51 J1-52 | GND MODE_DCE | Shorting group | - | - | - |
| J1-46 | Shield_GND | Single | _ | J2-1 | Shield GND |
| J1-11 J1-12 | TxD/RxD+ TxD/RxD- | Twisted pair no. 6 | --> --> | J2-4 J2-22 | SD+ SD- |
| J1-24 J1-23 | TxC/RxC+ TxC/RxC- | Twisted pair no. 9 | <-- <-- | J2-5 J2-23 | ST+ ST- |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | Twisted pair no. 11 | <-- <-- | J2-6 J2-24 | RD+ RD- |
| J1-9 J1-10 | RTS/CTS+ RTS/CTS- | Twisted pair no. 5 | --> --> | J2-7 J2-25 | RS+ RS- |
| J1-26 J1-25 | RxC/TxCE+ RxC/TxCE- | Twisted pair no. 10 | <-- <-- | J2-8 J2-26 | RT+ RT- |
| J1-1 J1-2 | CTS/RTS+ CTS/RTS- | Twisted pair no. 1 | <-- <-- | J2-9 J2-27 | CS+ CS- |
| J1-44 J1-45 | LL/DCD Circuit_GND | Twisted pair no. 12 | --> _ | J2-10 J2-37 | LL SC |
| J1-3 J1-4 | DSR/DTR+ DSR/DTR- | Twisted pair no. 2 | <-- <-- | J2-11 J2-29 | DM+ DM- |
| J1-7 J1-8 | DTR/DSR+ DTR/DSR- | Twisted pair no. 4 | --> --> | J2-12 J2-30 | TR+ TR- |
| J1-5 J1-6 | DCD/DCD+ DCD/DCD- | Twisted pair no. 3 | <-- <-- | J2-13 J2-31 | RR+ RR- |
| J1-13 J1-14 | TxCE/TxC+ TxCE/TxC- | Twisted pair no. 7 | --> --> | J2-17 J2-35 | TT+ TT- |
| J1-15 J1-16 | Circuit_GND Circuit_GND | Twisted pair no. 9 | - - | J2-19 J2-20 | SG RC |
| 60 Pin5 | Signal | Description | Direction | 37 Pin | Signal |
|---|---|---|---|---|---|
| J1-49 J1-48 | MODE_1 GND | Shorting group | - | - | - |
| J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | Twisted pair no. 11 | <-- <-- | J2-4 J2-22 | SD+ SD- |
| J1-13 J1-14 | TxCE/TxC+ TxCE/TxC- | Twisted pair no. 7 | --> --> | J2-5 J2-23 | ST+ ST- |
| J1-11 J1-12 | TxD/RxD+ TxD/RxD- | Twisted pair no. 6 | --> --> | J2-6 J2-24 | RD+ RD- |
| J1-1 J1-2 | CTS/RTS+ CTS/RTS- | Twisted pair no. 1 | <-- <-- | J2-7 J2-25 | RS+ RS- |
| J1-24 J1-23 | TxC/RxC+ TxC/RxC- | Twisted pair no. 9 | --> --> | J2-8 J2-26 | RT+ RT- |
| J1-9 J1-10 | RTS/CTS+ RTS/CTS- | Twisted pair no. 5 | --> --> | J2-9 J2-27 | CS+ CS- |
| J1-29 J1-30 | NIL/LL Circuit_GND | Twisted pair no. 12 | --> - | J2-10 J2-37 | LL SC |
| J1-7 J1-8 | DTR/DSR+ DTR/DSR- | Twisted pair no. 4 | --> --> | J2-11 J2-29 | DM+ DM- |
| J1-3 J1-4 | DSR/DTR+ DSR/DTR- | Twisted pair no. 2 | <-- <-- | J2-12 J2-30 | TR+ TR- |
| J1-5 J1-6 | DCD/DCD+ DCD/DCD- | Twisted pair no. 3 | --> --> | J2-13 J2-31 | RR+ RR- |
| J1-26 J1-25 | RxC/TxCE+ RxC/TxCE- | Twisted pair no. 10 | <-- <-- | J2-17 J2-35 | TT+ TT- |
| J1-15 J1-16 | Circuit_GND Circuit_GND | Twisted pair no. 8 | _ _ | J2-19 J2-20 | SG RC |
Figure C-4 shows the V.35 cable assembly; Table C-8 lists the DTE pinout; Table C-9 lists the DCE pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.

| 60 Pin6 | Signal | Description | Direction | 34 Pin | Signal |
|---|---|---|---|---|---|
| J1-49 J1-48 | MODE_1 GND | Shorting group | - | - | - |
| J1-50 J1-51 J1-52 | MODE_0 GND MODE_DCE | Shorting group | - | - | - |
| J1-53 J1-54 J1-55 J1-56 | TxC/NIL RxC_TxCE RxD/TxD GND | Shorting group | - | - | - |
| J1-46 | Shield_GND | Single | - | J2-A | Frame GND |
| J1-45 Shield | Circuit_GND - | Twisted pair no. 12 | - - | J2-B Shield | Circuit GND - |
| J1-42 Shield | RTS/CTS - | Twisted pair no. 9 | --> - | J2-C Shield | RTS - |
| J1-35 Shield | CTS/RTS - | Twisted pair no. 8 | <-- - | J2-D Shield | CTS - |
| J1-34 Shield | DSR/DTR - | Twisted pair no. 7 | <-- - | J2-E Shield | DSR - |
| J1-33 Shield | DCD/LL - | Twisted pair no. 6 | <-- - | J2-F Shield | RLSD - |
| J1-43 Shield | DTR/DSR - | Twisted pair no. 10 | --> - | J2-H Shield | DTR - |
| J1-44 Shield | LL/DCD - | Twisted pair no. 11 | --> - | J2-K Shield | LT - |
| J1-18 J1-17 | TxD/RxD+ TxD/RxD- | Twisted pair no. 1 | --> --> | J2-P J2-S | SD+ SD- |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | Twisted pair no. 5 | <-- <-- | J2-R J2-T | RD+ RD- |
| J1-20 J1-19 | TxCE/TxC+ TxCE/TxC- | Twisted pair no. 2 | --> --> | J2-U J2-W | SCTE+ SCTE- |
| J1-26 J1-25 | RxC/TxCE+ RxC/TxCE- | Twisted pair no. 4 | <-- <-- | J2-V J2-X | SCR+ SCR- |
| J1-24 J1-23 | TxC/RxC+ TxC/RxC- | Twisted pair no. 3 | <-- <-- | J2-Y J2-AA | SCT+ SCT- |
| 60 Pin7 | Signal | Description | Direction | 34 Pin | Signal |
|---|---|---|---|---|---|
| J1-49 J1-48 | MODE_1 GND | Shorting group | - | - | - |
| J1-50 J1-51 | MODE_0 GND | Shorting group | - | - | - |
| J1-53 J1-54 J1-55 J1-56 | TxC/NIL RxC_TxCE RxD/TxD GND | Shorting group | - | - | - |
| J1-46 | Shield_GND | Single | - | J2-A | Frame GND |
| J1-45 Shield | Circuit_GND - | Twisted pair no. 12 | - - | J2-B Shield | Circuit GND - |
| J1-35 Shield | CTS/RTS - | Twisted pair no. 8 | <-- - | J2-C Shield | RTS - |
| J1-42 Shield | RTS/CTS - | Twisted pair no. 9 | --> - | J2-D Shield | CTS - |
| J1-43 Shield | DTR/DSR - | Twisted pair no. 10 | --> - | J2-E Shield | DSR - |
| J1-44 Shield | LL/DCD - | Twisted pair no. 11 | --> - | J2-F Shield | RLSD - |
| J1-34 Shield | DSR/DTR - | Twisted pair no. 7 | <-- - | J2-H Shield | DTR - |
| J1-33 Shield | DCD/LL - | Twisted pair no. 6 | <-- - | J2-K Shield | LT - |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | Twisted pair no. 5 | <-- <-- | J2-P J2-S | SD+ SD- |
| J1-18 J1-17 | TxD/RxD+ TxD/RxD- | Twisted pair no. 1 | --> --> | J2-R J2-T | RD+ RD- |
| J1-26 J1-25 | RxC/TxCE+ RxC/TxCE- | Twisted pair no. 4 | <-- <-- | J2-U J2-W | SCTE+ SCTE- |
| J1-22 J1-21 | NIL/RxC+ NIL/RxC- | Twisted pair no. 3 | --> --> | J2-V J2-X | SCR+ SCR- |
| J1-20 J1-19 | TxCE/TxC+ TxCE/TxC- | Twisted pair no. 2 | --> --> | J2-Y J2-AA | SCT+ SCT- |
Figure C-5 shows the X.21 cable assembly; Table C-10 lists the DTE pinout; Table C-11 lists the DCE pinout. Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE.

| 60 Pin8 | Signal | Description | Direction | 15 Pin | Signal |
|---|---|---|---|---|---|
| J1-48 J1-47 | GND MODE_2 | Shorting group | - | - | - |
| J1-51 J1-52 | GND MODE_DCE | Shorting group | - | - | - |
| J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
| J1-11 J1-12 | TxD/RxD+ TxD/RxD- | Twisted pair no. 3 | --> --> | J2-2 J2-9 | Transmit+ Transmit- |
| J1-9 J1-10 | RTS/CTS+ RTS/CTS- | Twisted pair no. 2 | --> --> | J2-3 J2-10 | Control+ Control- |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | Twisted pair no. 6 | <-- <-- | J2-4 J2-11 | Receive+ Receive- |
| J1-1 J1-2 | CTS/RTS+ CTS/RTS- | Twisted pair no. 1 | <-- <-- | J2-5 J2-12 | Indication+ Indication- |
| J1-26 J1-25 | RxC/TxCE+ RxC/TxCE- | Twisted pair no. 5 | <-- <-- | J2-6 J2-13 | Timing+ Timing- |
| J1-15 Shield | Control_GND - | Twisted pair no. 4 | - - | J2-8 Shield | Control GND - |
| 60 Pin9 | Signal | Description | Direction | 15 Pin | Signal |
|---|---|---|---|---|---|
| J1-48 J1-47 | GND MODE_2 | Shorting group | - | - | - |
| J1-46 | Shield_GND | Single | - | J2-1 | Shield GND |
| J1-28 J1-27 | RxD/TxD+ RxD/TxD- | Twisted pair no. 6 | <-- <-- | J2-2 J2-9 | Transmit+ Transmit- |
| J1-1 J1-2 | CTS/RTS+ CTS/RTS- | Twisted pair no. 1 | <-- <-- | J2-3 J2-10 | Control+ Control- |
| J1-11 J1-12 | TxD/RxD+ TxD/RxD- | Twisted pair no. 3 | --> --> | J2-4 J2-11 | Receive+ Receive- |
| J1-9 J1-10 | RTS/CTS+ RTS/CTS- | Twisted pair no. 2 | --> --> | J2-5 J2-12 | Indication+ Indication- |
| J1-24 J1-23 | TxC/RxC+ TxC/RxC- | Twisted pair no. 4 | --> --> | J2-6 J2-13 | Timing+ Timing- |
| J1-15 Shield | Control_GND - | Twisted pair no. 5 | - - | J2-8 Shield | Control GND - |
Figure C-6 shows an Ethernet (AUI) cable assembly, and Table C-12 lists an AUI cable pinout.

| Pin10 | Ethernet Circuit | Signal |
|---|---|---|
| 3 | DO-A | Data Out Circuit A |
| 10 | DO-B | Data Out Circuit B |
| 11 | DO-S | Data Out Circuit Shield |
| 5 | DI-A | Data In Circuit A |
| 12 | DI-B | Data In Circuit B |
| 4 | DI-S | Data In Circuit Shield |
| 2 | CI-A | Control In Circuit A |
| 9 | CI-B | Control In Circuit B |
| 1 | CI-S | Control In Circuit Shield |
| 6 | VC | Voltage Common |
| 13 | VP | Voltage Plus |
| 14 | VS | Voltage Shield (L25 and M25) |
| Shell | PG | Protective Ground |
Table C-13 lists the pinout for the Token Ring interface port.
| 9 Pin11 | Signal |
|---|---|
| 1 | Receive |
| 3 | +5V1 |
| 5 | Transmit |
| 6 | Receive |
| 9 | Transmit |
Figure C-7 shows the RJ-45 breakout cable with pinouts for the 68-pin SCSI port and the RJ-45 serial port. Table C-14 contains the pinout for the RJ-45 end, and Table C-15 contains the pinout for the 68-pin SCSI type connector.

| 8-Pin RJ-45 | Signal | Direction |
|---|---|---|
| 1 | CTS | <-- |
| 2 | DSR/DCD | <-- |
| 3 | RXD | <-- |
| 4 | RXD/GND | -- |
| 5 | TXD/GND | -- |
| 6 | TXD | --> |
| 7 | DTR | --> |
| 8 | RTS | --> |
| RJ-45 Plug | Pin | Signal | 68-Pin SCSI (J1) |
|---|---|---|---|
1 | 1 | CTS | 39 |
| 2 | DSR | 5 | |
| 3 | RXD | 38 | |
| 4 | RXD GND | 4 | |
| 5 | TXD GND | 37 | |
| 6 | TXD | 3 | |
| 7 | DTR | 36 | |
| 8 | RTS | 2 | |
2 | 1 | CTS | 43 |
| 2 | DSR | 9 | |
| 3 | RXD | 42 | |
| 4 | RXD GND | 8 | |
| 5 | TXD GND | 41 | |
| 6 | TXD | 7 | |
| 7 | DTR | 40 | |
| 8 | RTS | 6 | |
3 | 1 | CTS | 47 |
| 2 | DSR | 13 | |
| 3 | RXD | 46 | |
| 4 | RXD GND | 12 | |
| 5 | TXD GND | 45 | |
| 6 | TXD | 11 | |
| 7 | DTR | 44 | |
| 8 | RTS | 10 | |
4 | 1 | CTS | 51 |
| 2 | DSR | 17 | |
| 3 | RXD | 50 | |
| 4 | RXD GND | 16 | |
| 5 | TXD GND | 49 | |
| 6 | TXD | 15 | |
| 7 | DTR | 48 | |
| 8 | RTS | 14 | |
5 | 1 | CTS | 55 |
| 2 | DSR | 21 | |
| 3 | RXD | 54 | |
| 4 | RXD GND | 20 | |
| 5 | TXD GND | 53 | |
| 6 | TXD | 19 | |
| 7 | DTR | 52 | |
| 8 | RTS | 18 | |
6 | 1 | CTS | 59 |
| 2 | DSR | 25 | |
| 3 | RXD | 58 | |
| 4 | RXD GND | 24 | |
| 5 | TXD GND | 57 | |
| 6 | TXD | 23 | |
| 7 | DTR | 56 | |
| 8 | RTS | 22 | |
7 | 1 | CTS | 53 |
| 2 | DSR | 29 | |
| 3 | RXD | 62 | |
| 4 | RXD GND | 28 | |
| 5 | TXD GND | 61 | |
| 6 | TXD | 27 | |
| 7 | DTR | 60 | |
| 8 | RTS | 26 | |
8 | 1 | CTS | 67 |
| 2 | DSR | 33 | |
| 3 | RXD | 66 | |
| 4 | RXD GND | 32 | |
| 5 | TXD GND | 65 | |
| 6 | TXD | 31 | |
| 7 | DTR | 64 | |
| 8 | RTS | 30 |
Refer to Table C-16 for a list of the pins used on the RJ-45-to-DB-25 adapters, used with an RJ-45 cable, to connect terminals and modems to the Cisco 2500 series access server. The cable you use may be a roll-over cable or a straight cable.
A roll-over cable can be detected by comparing the two modular ends of the cable. Holding the cables in your hand, side-by-side, with the tab at the back, the wire connected to the pin on the outside of the left plug should be the same color as the pin on the outside of the right plug. If your cable was purchased from Cisco, pin 1 will be white on one connector, and pin 8 will be white on the other (a roll-over cable reverses pins 1 and 8, 2 and 7, 3 and 6, and 4 and 5). (See Figure C-8.)

The Cisco 2500 series access server ships with a rolled cable. Connection to a terminal or a modem will require an RJ-45-to-DB-25 adapter, and possibly a DB-25-to-DB9 adapter. Refer to Table C-17 for the cable and adapter configurations that can be used to connect terminals and modems to the Cisco 2500 series access server.
| Adapter | DTE M/F Pins1 | DCE M/F Pins | MMOD Pins2 |
|---|---|---|---|
| RJ-45 Pins | DB-25 Pins | ||
| 1 | 4 | 5 | 5 |
| 2 | 20 | 6 | 8 |
| 3 | 2 | 3 | 3 |
| 4 | 7 | 7 | 7 |
| 5 | 7 | 7 | 7 |
| 6 | 3 | 2 | 2 |
| 7 | 6 | 20 | 20 |
| 8 | 5 | 4 | 4 |
| Access Server Port | RJ-45 Cable Type | DB-25 Adapter | End Device |
|---|---|---|---|
| Console or auxiliary | Rolled | FDTE1 | Terminal |
| Console or auxiliary | Straight | FDCE | Terminal |
| Auxiliary or console | Rolled | MMOD2 | Modem3 |
|
|