This document provides international regulatory and safety compliance information for the
Cisco 800 series routers. Use this document with the Cisco 800 Series Routers Hardware Installation Guide, Cisco 811 and Cisco 813 Routers Hardware Installation Guide, Upgrading Flash Memory in Cisco 800 Series Routers, and Upgrading Dynamic RAM in Cisco 800 Series Routers.
This document includes the following sections:
Table 1 lists the agency approvals that apply to the routers.
| Safety Standards | EMI Standards | PTT Standards |
|---|---|---|
UL 1950 | CFR 47, part 15, class B | FCC part 68 |
CSA 22.2 No. 950 | ICES, Issue 2, class B | CS-03 |
TUV-GS to EN 60950:1992 with Amendments A1 through A4 | VCCI class 2 | CTR3 (CE168_X_) |
IEC 60950 with Amendments A1 through A4 and all country deviations | AZ/NRZ 3548 class B | JATE, NTT |
TS-001:1997 | EN 55022, IEC 1000-3-3 | TS013, TS031 |
AS/NZS 3260 with Amendments A1 through A4 | IEC 1000-4-3 level 3 | PTC 231 |
EN 300 047 | IEC 1000-4-5 level 3 |
|
EN 41003 |
|
|
IEEE 802.3 |
|
|
The Cisco 800 series routers comply with Part 68 of the FCC rules. On the bottom of this equipment is a label that contains, among other information, the FCC registration number. If requested, this information must be provided to the telephone company.
An FCC compliant telephone cord and modular plug is provided with this equipment, designed to be connected to the telephone network or premises wiring using a compatible modular jack that is Part 68 compliant.
This equipment cannot be used on telephone company provided coin service. Connection to party line service is subject to state tariffs.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact us for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved.
It is recommended that the customer install an AC surge arrestor in the AC outlet to which this device is connected. This is to avoid damage to the equipment caused by local lightening strikes and other electrical surges.
![]() |
Note The AC surge arrestor does not protect an ISDN line equipped with an external Network Termination 1 (NT1) device. |
Table 2 lists the Universal Service Order Code (USOC) jacks used by the Cisco 800 series routers and WAN interface cards.
| Cisco Product Number | Facility Interface Code | Service Order Code | Jack Type |
|---|---|---|---|
CISCO801 | 02IS | 6.0N | RJ-49C |
CISCO802 | 02IS5 | 6.0N | RJ-48C |
In addition to the warnings and safety guidelines listed in the "Translated Safety Warnings" section later in this document, the following operating condition applies to routers used in Canada:
The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements documents. The Department does not guarantee the equipment will operate to the user's satisfaction.
Before installing the equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for your own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
![]() |
Caution Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. |
The warnings and safety guidelines listed in the "Translated Safety Warnings" section later in this document apply to routers used in the European Community.
In addition to the warnings and safety guidelines listed in the "Translated Safety Warnings" section later in this document, the following warnings apply to routers used in the United Kingdom:
This section contains the declaration of conformity.
We: Cisco Systems, Inc.
Declare under our sole legal responsibility that the following products:
to which this declaration relates, are in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Name: Jim Lambert
Title: Director, Corporate Compliance Engineering
Date of Issue: November 16, 1998
On behalf of Cisco Systems, Inc.
This section lists the Conformité Européenne (CE) directive:
The CE 0168X signifies that this product meets the Telecommunications Directive 91/263/EEC.
The following statements are warnings or safety guidelines. A warning means danger. You are in a situation that could cause bodily injury. Before working on equipment, be aware of the hazards involved with electrical circuitry and standard safety practices to prevent accidents.
| |||
Waarschuwing | Als er een geschiktheidsymbool met een overgetrokken kruis boven een poort aanwezig is, dan mag u deze poort niet op een openbaar netwerk aansluiten dat aan de normen van de Europese Unie voldoet. Als u de poort op een dergelijk openbaar netwerk aansluit, kan dit ernstig letsel of schade aan uw router-eenheid veroorzaken. | ||
Varoitus | Jos portin päälle ilmestyy soveltuvuussymboli, jonka päällä on rasti, porttia ei saa liittää Euroopan unionin standardien mukaiseen julkiseen verkkoon. Jos portti liitetään tällaiseen julkiseen verkkoon, seurauksena voi olla henkilö- tai reititinvaurio. | ||
Attention | Pour éviter tout risque d'accident corporel et/ou de dommage matériel, si le symbole de capacité barré d'une croix apparaît au-dessus d'un port, il est vivement recommandé de ne pas connecter ce port à un réseau public aux normes de l'Union Européenne. | ||
Warnung | Wenn oberhalb des Ports das Verträglichkeitssymbol mit einem Kreuz darüber erscheint, dürfen Sie den Port nicht an ein öffentliches Netzwerk anschließen, daß den Standards der Europäischen Gemeinschaft folgt. Das Anschließen des Port an ein solches Netzwerk kann zu schweren Verletzungen führen oder Ihren Router beschädigen. | ||
Avvertenza | Se su una porta compare il simbolo di idoneità sbarrato, significa che la porta non può essere collegata a una rete pubblica a norma UE. Collegando la porta a un simile tipo di rete pubblica si possono correre seri rischi e provocare danni al proprio router. | ||
Advarsel | Hvis symbolet for anvendelse med et kryss over vises over en utgang, skal utgangen ikke kobles til et offentlig nettverk som følger EU-standardene. Hvis utgangen kobles til denne typen offentlig nettverk, kan det medføre alvorlig personskade eller skade på ruteren. | ||
Aviso | Se o símbolo de adequação com uma cruz sobreposta aparecer acima de uma porta, não conectar a porta a uma rede pública que obedece aos padrões da União Europeia. A conexão da porta a este tipo de rede pública pode causar avarias ou danos severos ao seu distribuidor. | ||
¡Advertencia! | Si aparece el símbolo de idoneidad con una cruz sobrepuesta encima de un puerto, no debe conectar el puerto a una red pública que siga los estándares de la Unión Europea. Si conecta el puerto a este tipo de red pública puede lesionarse o dañar su router. | ||
Varning! | Om lämplighetssymbolen med ett överlagt kors visas ovanför en port, får porten inte anslutas till ett offentligt nätverk av EU-standard. Om porten ansluts till denna typ av offentligt nätverk kan det förorsaka allvarlig personskada eller skada på routern. | ||
| |||
| |||
Waarschuwing | Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden. | ||
Varoitus | Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen. | ||
Avertissement | Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent. | ||
Achtung | Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen. | ||
Avvertenza | Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio. | ||
Advarsel | Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret. | ||
Aviso | Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado. | ||
¡Atención! | Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado. | ||
Varning | Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal. | ||
| |||
| |||
Waarschuwing | Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt. | ||
Varoitus | Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen. | ||
Attention | Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. | ||
Warnung | Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen. | ||
Avvertenza | Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore. | ||
Advarsel | Les installasjonsinstruksjonene før systemet kobles til strømkilden. | ||
Aviso | Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia. | ||
¡Advertencia! | Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación. | ||
Varning! | Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet. | ||
| |||
| |||
Waarschuwing | Alvorens aan een systeem met een standby/uit-schakelaar te werken dient u de voeding uit te schakelen door de voedingsschakelaar op standby te zetten en het voedingssnoer te verwijderen. | ||
Varoitus | Katkaise virta valmiustila/virtakytkimellä varustetusta laitteesta ennen sen käyttämistä painamalla virtakytkin valmiusasentoon ja irrottamalla sähköjohto. | ||
Attention | Avant d'utiliser un système équipé d'un commutateur « Standby/Off» (pause/arrêt), coupez l'alimentation en plaçant le commutateur sur la position Stanby et débranchez le cordon d'alimentation. | ||
Warnung | Bevor Sie an einem System mit einem Bereit-/Aus-Schalter arbeiten, stellen Sie den Strom ab, indem Sie den Stromschalter auf "Bereit" stellen und das Stromkabel herausziehen. | ||
Avvertenza | Prima di lavorare su un sistema con interruttore attesa/off, spegnetelo premendo il pulsante sulla posizione di attesa e staccate la spina elettrica. | ||
Advarsel | Før det utføres arbeid på et system som har en standby/av-bryter, skal strømmen slås av ved å skyve av/på-bryteren til standby og trekke ut strømledningen. | ||
Aviso | Antes de começar a trabalhar num sistema com um interruptor standby (posição de espera)/off (desligado), desligue a corrente eléctrica colocando o interruptor na posição standby e retire o cabo de alimentação da tomada. | ||
¡Advertencia! | Antes de empezar a trabajar con un sistema cuyo interruptor incluya la posición standby, cierre la corriente posicionando el interruptor a standby y a continuación desconecte el cable eléctrico. | ||
Varning! | Innan du arbetar på ett system med en standby-/strömbrytaromkopplare, slå av strömmen genom att ställa omkopplaren på standby och koppla ur nätsladden. | ||
| |||
| |||
Waarschuwing | Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen. | ||
Varoitus | Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien). Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin. | ||
Attention | Avant d'accéder à cet équipement connecté aux lignes électriques, ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes. | ||
Warnung | Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen. Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden. | ||
Avvertenza | Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali. | ||
Advarsel | Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene. | ||
Aviso | Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais. | ||
¡Advertencia! | Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes. | ||
Varning! | Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna. | ||
| |||
| |||
Waarschuwing | De verbinding met ISDN (Integrated Services Digital Network = Digitaal netwerk met geïntegreerde faciliteiten) wordt beschouwd als een spanningsbron die ontoegankelijk dient te zijn voor gebruikers. Gebruikers dienen geen poging te doen om door de openbare telefoondienst (PTT) verstrekte apparatuur of aansluitingshardware te openen of ermee te knoeien. Alle vastbedrade verbindingen (behalve die verbindingen die gemaakt zijn door een niet-verwijderbare, slechts eenmaal te verbinden stekker) dienen slechts door PTT-personeel of door daartoe opgeleide ingenieurs gemaakt te worden. | ||
Varoitus | ISDN-liitäntää pidetään jännitelähteenä, jonka kanssa käyttäjän ei tulisi päästä kosketuksiin. Käyttäjien ei tulisi yrittää peukaloida tai avata laitteita tai liittimiä, jotka kuuluvat yleiselle puhelinlaitokselle (PTO). Ainoastaan yleisen puhelinlaitoksen henkilökunnan tai ammattitaitoisten teknikoiden tulee tehdä kaapeliliitännät (lukuun ottamatta kiinteitä pistokkeita, jotka yhdistetään ainoastaan yhden kerran). | ||
Attention | La connexion du réseau numérique intégré (Integrated Services Digital Network ou ISDN) constitue une source de tension qui ne doit pas être accessible à l'utilisateur. Les utilisateurs ne doivent jamais tenter de modifier ni même d'ouvrir un matériel fourni par une compagnie de téléphone public, ou le matériel de connexion. Toute connexion câblée (autre que celles établies par une prise non démontable à connexion unique) ne doit être effectuée que par le personnel de la compagnie de téléphone ou par des techniciens proprement formés. | ||
Warnung | Die ISDN-Verbindung gilt als eine Spannungsquelle, die dem Anwender unzugänglich sein sollte. Anwender sollten nicht versuchen, sich an der von den Anbietern öffentlicher TK-Dienste gelieferten Ausstattung oder Verbindungs-Hardware zu schaffen zu machen oder sie zu öffnen. Alle festverdrahteten Verbindungen (mit Ausnahme der Verbindungen mit einem nicht abnehmbaren, nur einmal anzuschließenden Stecker) sind von Mitarbeitern des TK-Anbieters oder von entsprechend geschulten Technikern herzustellen. | ||
Avvertenza | Il collegamento ISDN (Integrated Services Digital Network -Rete digitale a servizi integrati) viene considerato come una fonte di tensione che dovrebbe essere inaccessibile al contatto dell'utente. Gli utenti non devono né manomettere né provare ad aprire le apparecchiature o i dispositivi di collegamento forniti dalla società telefonica. Qualsiasi collegamento cablato (ad eccezione di una spina non rimovibile, da installare una sola volta) deve essere eseguito esclusivamente da un dipendente della società telefonica o da tecnici specializzati. | ||
Advarsel | ISDN-koblingen betraktes som en spenningskilde som bør være utilgjengelig for brukeren. Brukere bør ikke klusse med eller åpne utstyr eller tilkoblingsmateriale som er utstyrt av Telenor. Eventuelle faste installasjoner (bortsett fra koblinger som er foretatt med et støpsel for engangsbruk og som ikke kan fjernes) må kun utføres av Telenor-montører. | ||
Aviso | A conexão RDIS (Rede Digital com Integração de Serviços) é interpretada como uma fonte de tensão que deverá ser inacessível ao utilizador. Os utilizadores não deverão tentar violar qualquer equipamento ou conexão de serviço telefónico público. Qualquer conexão de rede de fios (para além daquela estabelecida por uma ficha não-removível de ligação única), deverá apenas ser efectuada por pessoal dos serviços telefónicos ou engenheiros devidamente treinados. | ||
¡Advertencia! | La conexión al circuito RDSI (Red Digital de Servicios Integrados) se considera como una fuente de voltaje con la cual el usuario no debe entrar en contacto. Los usuarios deberán evitar manipular indebidamente, o abrir, los equipos o hardware de conexión proporcionados por cualquier compañía operadora de la red pública de telefonía. Las conexiones de cable rígido que sean necesarias (excepto las de clavija no desmontable de un solo uso) deberán ser realizadas exclusivamente por personal de la entidad operadora de la red pública de telefonía, o por personal técnico adecuadamente capacitado. | ||
Varning! | ISDN-anslutningen betraktas som en spänningskälla och bör inte vara åtkomlig för användaren (ISDN: Integrated Services Digital Network = digitalt flertjänstnät). Användare får inte manipulera eller söka öppna utrustning eller anslutningsdon som tillhandahållits av telefonbolag (PTO-produkter). Anslutning av ledningar (med undantag av en icke löstagbar propp för engångsanslutning) får endast utföras av PTO-anställda eller lämpligt utbildade tekniker. | ||
| |||
| |||
Waarschuwing | Om elektrische schokken te vermijden, mogen veiligheidscircuits met extra lage spanning (genaamd SELV = Safety Extra-Low Voltage) niet met telefoonnetwerkspanning (TNV) circuits verbonden worden. LAN (Lokaal netwerk) poorten bevatten SELV circuits en WAN (Regionaal netwerk) poorten bevatten TNV circuits. Sommige LAN en WAN poorten gebruiken allebei RJ-45 connectors. Ga voorzichtig te werk wanneer u kabels verbindt. | ||
Varoitus | Jotta vältyt sähköiskulta, älä kytke pienjännitteisiä SELV-suojapiirejä puhelinverkkojännitettä (TNV) käyttäviin virtapiireihin. LAN-portit sisältävät SELV-piirejä ja WAN-portit puhelinverkkojännitettä käyttäviä piirejä. Osa sekä LAN- että WAN-porteista käyttää RJ-45-liittimiä. Ole varovainen kytkiessäsi kaapeleita. | ||
Attention | Pour éviter une électrocution, ne raccordez pas les circuits de sécurité basse tension (Safety Extra-Low Voltage ou SELV) à des circuits de tension de réseau téléphonique (Telephone Network Voltage ou TNV). Les ports du réseau local (LAN) contiennent des circuits SELV et les ports du réseau longue distance (WAN) sont munis de circuits TNV. Certains ports LAN et WAN utilisent des connecteurs RJ-45. Raccordez les câbles en prenant toutes les précautions nécessaires. | ||
Warnung | Zur Vermeidung von Elektroschock die Sicherheits-Kleinspannungs-Stromkreise (SELV-Kreise) nicht an Fernsprechnetzspannungs-Stromkreise (TNV-Kreise) anschließen. LAN-Ports enthalten SELV-Kreise, und WAN-Ports enthalten TNV-Kreise. Einige LAN- und WAN-Ports verwenden auch RJ-45-Steckverbinder. Vorsicht beim Anschließen von Kabeln. | ||
Avvertenza | Per evitare scosse elettriche, non collegare circuiti di sicurezza a tensione molto bassa (SELV) ai circuiti a tensione di rete telefonica (TNV). Le porte LAN contengono circuiti SELV e le porte WAN contengono circuiti TNV. Alcune porte LAN e WAN fanno uso di connettori RJ-45. Fare attenzione quando si collegano cavi. | ||
Advarsel | Unngå å koble lavspenningskretser (SELV) til kretser for telenettspenning (TNV), slik at du unngår elektrisk støt. LAN-utganger inneholder SELV-kretser og WAN-utganger inneholder TNV-kretser. Det finnes både LAN-utganger og WAN-utganger som bruker RJ-45-kontakter. Vær forsiktig når du kobler kabler. | ||
Aviso | Para evitar choques eléctricos, não conecte os circuitos de segurança de baixa tensão (SELV) aos circuitos de tensão de rede telefónica (TNV). As portas LAN contêm circuitos SELV e as portas WAN contêm circuitos TNV. Algumas portas LAN e WAN usam conectores RJ-45. Tenha o devido cuidado ao conectar os cabos. | ||
¡Advertencia! | Para evitar la sacudida eléctrica, no conectar circuitos de seguridad de voltaje muy bajo (safety extra-low voltage = SELV) con circuitos de voltaje de red telefónica (telephone network voltage = TNV). Los puertos de redes de área local (local area network = LAN) contienen circuitos SELV, y los puertos de redes de área extendida (wide area network = WAN) contienen circuitos TNV. En algunos casos, tanto los puertos LAN como los WAN usan conectores RJ-45. Proceda con precaución al conectar los cables. | ||
Varning! | För att undvika elektriska stötar, koppla inte säkerhetskretsar med extra låg spänning (SELV-kretsar) till kretsar med telefonnätspänning (TNV-kretsar). LAN-portar innehåller SELV-kretsar och WAN-portar innehåller TNV-kretsar. Vissa LAN- och WAN-portar är försedda med RJ-45-kontakter. Iaktta försiktighet vid anslutning av kablar. | ||
| |||
| |||
Waarschuwing | Het uiteindelijke wegruimen van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. | ||
Varoitus | Tämä tuote on hävitettävä kansallisten lakien ja määräysten mukaisesti. | ||
Attention | La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. | ||
Warnung | Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. | ||
Avvertenza | Lo smaltimento di questo prodotto deve essere eseguito secondo le leggi e regolazioni locali. | ||
Advarsel | Endelig kassering av dette produktet skal være i henhold til alle relevante nasjonale lover og bestemmelser. | ||
Aviso | Deitar fora este produto em conformidade com todas as leis e regulamentos nacionais. | ||
¡Advertencia! | Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. | ||
Varning! | Vid deponering hanteras produkten enligt gällande lagar och bestämmelser. | ||
| |||
| |||
Waarschuwing | De ISDN-kabel bevat voltages die gevaar voor het netwerk opleveren. Als de ISDN-kabel verwijderd moet worden, verwijdert u om mogelijke elektrische schokken te vermijden eerst het uiteinde dat niet op de router is aangesloten. Verder bevat tevens de systeemkaart in de buurt van de ISDN-poort (RJ-45-aansluiting) voltages die gevaar voor het netwerk opleveren, onafhankelijk van wanneer de voeding wordt uitgeschakeld (door de voedingsschakelaar op standby te zetten). | ||
Varoitus | ISDN-johdossa on verkolle vaarallisia jännitteitä. Jos ISDN-kaapeli irrotetaan, irrota ensin reitittimen puoleinen pää sähköiskun välttämiseksi. Verkolle vaarallisia jännitteitä on myös järjestelmäkortissa ISDN-portin alueella (RJ-45-liitin), vaikka virta olisikin katkaistu painamalla virtakytkin valmiusasentoon. | ||
Attention | Des tensions électriques réseau dangereuses circulent sur le câble RNIS. Pour éviter tout risque de choc électrique lorsque vous débranchez ce câble, déconnectez d'abord l'extrémité non raccordée au routeur. Par ailleurs, des tensions dangereuses sont également présentes autour du port RNIS (connecteur RJ-45) de la carte système, que le système soit sous tension ou hors tension (commutateur d'alimentation sur « Standby »). | ||
Warnung | Auf dem ISDN-Kabel herrschen gefährliche Spannungen. Bei Entfernung des ISDN-Kabels muß zuerst das Kabel von der Routerseite her abgetrennt werden, um einen möglichen elektrischen Schlag zu vermeiden. Gefährliche Spannungen herrschen darüber hinaus auf der Systemkarte im Bereich des ISDN-Ports (RJ-45 Steckverbinder) und zwar unabhängig davon, ob der Strom (durch Umlegung des Stromschalters auf "Bereit") abgeschaltet ist. | ||
Avvertenza | Sono presenti dei voltaggi elettrici rete pericolosi nei cavi ISDN. Se staccate il cavo ISDN, dovete prima staccare l'estremità collegata al router per evitare scosse elettriche. Pericolose tensioni elettriche rete sono presente anche sulla scheda del sistema vicino alla porta ISDN (connettore RJ-45) a prescindere da quando sia stata spenta l'alimentazione elettrica (premendo il pulsante sulla posizione di attesa). | ||
Advarsel | Livsfarlig spenning er til stede i nettverkets ISDN-kabel. Hvis du kobler fra ISDN-kabelen, skal enden som vender bort fra ruteren, kobles fra først for å unngå mulig elektrisk støt. Livsfarlig spenning er også til stede på nettverkets systemkort i området ved ISDN-utgangen (RJ-45-kobingen), uten hensyn til når strømmen er slått av (ved å skyve strømbryteren til standby). | ||
Aviso | Existem tensões de rede perigosas no cabo de Rede Digital com Integração de Serviços-RDIS (ISDN-Integrated Services Digital Network). Se for desligar o cabo RDIS, desligue primeiro a extremidade oposta à do comutador para evitar possíveis choques eléctricos. Existem tensões de rede perigosas também na placa do sistema, nomeadamente, na área da porta RDIS (conector RJ-45), independentemente do facto da corrente estar desligada (ao colocar o interruptor em standby) ou não. | ||
¡Advertencia! | Las líneas RSDI contienen voltajes peligrosos de la red. Si desconecta el cable RSDI, separe primero el final del router para evitar posibles choques eléctricos. La tarjeta del sistema en el área del puerto RSDI (conector RJ-45) también contiene altos voltajes de la red, independientemente de si está apagada (posicionando el interruptor de la corriente a standby). | ||
Varning! | I ISDN-kabeln förekommer spänningar som är farliga för nätverk. Om du kopplar ur ISDN-kabeln, undvik eventuell elstöt genom att först koppla ur den ände som är längst bort ifrån routern. Spänningar som är farliga för nätverk förekommer också på systemkortet i området intill ISDN-porten (RJ-45-koppling), oberoende av när strömmen slås av (genom att ställa omkopplaren på standby). | ||
| |||
| |||
Waarschuwing | Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen. | ||
Varoitus | Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla. | ||
Attention | Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage. | ||
Warnung | Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert. | ||
Avvertenza | Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini. | ||
Advarsel | Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner. | ||
Aviso | Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada). | ||
¡Advertencia! | No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera. | ||
Varning! | Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar. | ||
| |||
| |||
Waarschuwing | Om brandgevaar te reduceren, dient slechts telecommunicatielijnsnoer nr. 26 AWG of groter gebruikt te worden. | ||
Varoitus | Tulipalovaaran vähentämiseksi käytä ainoastaan nro 26 AWG- tai paksumpaa tietoliikennejohdinta. | ||
Attention | Pour réduire le risque d'incendie, n'utiliser que des cordons de lignes de télécommunications de type AWG nº 26 ou plus larges. | ||
Warnung | Zur Reduzierung der Feuergefahr eine Fernmeldeleitungsschnur der Größe 26 AWG oder größer verwenden. | ||
Avvertenza | Per ridurre il rischio di incendio, usare solo un cavo per linea di telecomunicazioni di sezione 0,12 mm2 (26 AWG) o maggiore. | ||
Advarsel | Bruk kun AWG nr. 26 eller telekommunikasjonsledninger med større dimensjon for å redusere faren for brann. | ||
Aviso | Para reduzir o risco de incêndio, utilize apenas terminais de fio de telecomunicações Nº. 26 AWG ou superiores. | ||
Advertencia | Para reducir el riesgo de incendios, usar sólo líneas de telecomunicaciones de calibre No. 26 AWG o más gruesas. | ||
Varning! | För att minska brandrisken skall endast Nr. 26 AWG eller större telekommunikationsledning användas. | ||
| |||
| |||
Waarschuwing | Deze apparatuur brengt een belsignaal voort wat op spanningsgevaar duidt. Wanneer de bel rinkelt, mogen de RJ-11-draden (telefoon), d.w.z. de geleiders van een aan de RJ-11-poort verbonden kabel, en de bijbehorende circuitplaat, niet aangeraakt worden. De bel wordt geactiveerd door een binnenkomend analoog gesprek. | ||
Varoitus | Tämä laite on varustettu soittovirran generaattorilla (puhelinkello), jossa on vaarallinen jännite. Älä koske RJ-11 (puhelimen liittymän) liitäntäjohtoihin (johtimet), RJ-11-liittymään yhdistetyn kaapelin johtimiin tai piirilevyyn puhelinkellon ollessa päälle kytkettynä. Saapuva analogisoitto aktivoi puhelinkellon. | ||
Attention | Cet appareil contient un générateur de sonneries, source de tensions dangereuses. Lorsque la sonnerie est active, ne touchez en aucun cas les fils de port (conducteurs) du connecteur RJ11 (téléphone), les âmes du câble connecté au port RJ11 ou les cartes imprimées correspondantes. La sonnerie est activée par un appel entrant. | ||
Warnung | Dieses Gerät enthält einen Rufsignalgeber (Rufumsetzer), der unter gefährlicher Spannung steht. Die RJ-11 (Telefon-) Anschlußdrähte (Leiter), die Leiter eines im RJ-11-Anschluß eingesteckten Kabels bzw. die dazugehörige Leiterplatte auf keinen Fall berühren, wenn der Rufumsetzer aktiviert ist. Der Rufumsetzer wird aktiviert, wenn ein Analoganruf eingeht. | ||
Avvertenza | Questa apparecchiatura contiene un generatore di segnali di chiamata (suoneria) che origina un voltaggio pericoloso. Quando la suoneria è attivata, non toccare l'RJ-11 (telefono), i fili della porta (conduttori), i conduttori di un cavo collegato alla porta RJ-11 o l'associata scheda a circuiti stampati. La suoneria è attivata da un segnale di chiamata analogica in arrivo. | ||
Advarsel | Dette utstyret inneholder en ringesignalgenerator (ringeklokke) med farlig spenning. Berør ikke RJ-11-utgangens (telefonutgangens) ledninger (lederne), lederne til den kabelen som er koplet til RJ-11-utgangen, eller tilhørende kretskort når ringeklokken er aktivert. Ringeklokken aktiveres av innkommende analoge anrop. | ||
Aviso | Este equipamento contém um gerador de sinal de campainha que constitui uma fonte de tensão perigosa. Não toque nos fios de porta (condutores) RJ-11 (telefone), nos condutores do cabo conectado à porta RJ-11 ou na placa de circuito associada quando a campainha estiver activa. A campainha é activada pela entrada de uma chamada analógica. | ||
¡Advertencia! | Este equipo contiene un generador de señal de llamada (timbre), el cual es una fuente de tensión peligrosa. No toque los alambres de la puerta (conductores) RJ-11 (teléfono), ni los conductores de un cable conectado a la puerta RJ-11, ni la placa del circuito relacionado cuando el timbre está activo. El timbre es activado por medio de una llamada de entrada analógica. | ||
Varning! | Denna utrustning innehåller en tongenerator (ringklocka) med farlig spänning. Vidrör inte RJ-11-portens (telefonportens) ledningar (ledarna), ledarna hos kabel som är ansluten till porten RJ-11 eller tillhörande kretskort när ringklockan är aktiverad. Ringklockan aktiveras av inkommande analoga anrop. | ||
| |||
| |||
Waarschuwing | Het apparaat is ontworpen om te functioneren met TN energiesystemen. | ||
Varoitus | Koje on suunniteltu toimimaan TN-sähkövoimajärjestelmien yhteydessä. | ||
Attention | Ce dispositif a été conçu pour fonctionner avec des systèmes d'alimentation TN. | ||
Warnung | Das Gerät ist für die Verwendung mit TN-Stromsystemen ausgelegt. | ||
Avvertenza | Il dispositivo è stato progettato per l'uso con sistemi di alimentazione TN. | ||
Advarsel | Utstyret er utfomet til bruk med TN-strømsystemer. | ||
Aviso | O dispositivo foi criado para operar com sistemas de corrente TN. | ||
¡Advertencia! | El equipo está diseñado para trabajar con sistemas de alimentación tipo TN. | ||
Varning! | Enheten är konstruerad för användning tillsammans med elkraftssystem av TN-typ. | ||
| |||
| |||
Waarschuwing | Dit produkt is afhankelijk van de installatie van het gebouw voor kortsluit- (overstroom)beveiliging. Controleer of er een zekering of stroomverbreker van niet meer dan 120 Volt wisselstroom, 15 A voor de V.S. (240 Volt wisselstroom, 16 A internationaal) gebruikt wordt op de fasegeleiders (alle geleiders die stroom voeren). | ||
Varoitus | Tämä tuote on riippuvainen rakennukseen asennetusta oikosulkusuojauksesta (ylivirtasuojauksesta). Varmista, että vaihevirtajohtimissa (kaikissa virroitetuissa johtimissa) käytetään Yhdysvalloissa alle 120 voltin, 15 ampeerin ja monissa muissa maissa 240 voltin, 16 ampeerin sulaketta tai suojakytkintä. | ||
Attention | Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de l'installation électrique du local. Vérifier qu'un fusible ou qu'un disjoncteur de 120 V alt., 15 A U.S. maximum (240 V alt., 16 A international) est utilisé sur les conducteurs de phase (conducteurs de charge). | ||
Warnung | Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß- bzw. Überstromschutz installiert ist. Stellen Sie sicher, daß eine Sicherung oder ein Unterbrecher von nicht mehr als 240 V Wechselstrom, 16 A (bzw. in den USA 120 V Wechselstrom, 15 A) an den Phasenleitern (allen stromführenden Leitern) verwendet wird. | ||
Avvertenza | Questo prodotto dipende dall'installazione dell'edificio per quanto riguarda la protezione contro cortocircuiti (sovracorrente). Verificare che un fusibile o interruttore automatico, non superiore a 120 VCA, 15 A U.S. (240 VCA, 16 A internazionale) sia stato usato nei fili di fase (tutti i conduttori portatori di corrente). | ||
Advarsel | Dette produktet er avhengig av bygningens installasjoner av kortslutningsbeskyttelse (overstrøm). Kontroller at det brukes en sikring eller strømbryter som ikke er større enn 120 VAC, 15 A (USA) (240 VAC, 16 A internasjonalt) på faselederne (alle strømførende ledere). | ||
Aviso | Este produto depende das instalações existentes para protecção contra curto-circuito (sobrecarga). Assegure-se de que um fusível ou disjuntor não superior a 240 VAC, 16A é utilizado nos condutores de fase (todos os condutores de transporte de corrente). | ||
¡Advertencia! | Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) deló propio edificio. Asegurarse de que se utiliza un fusible o interruptor automático de no más de 240 voltios en corriente alterna (VAC), 16 amperios del estándar internacional (120 VAC, 15 amperios del estándar USA) en los hilos de fase (todos aquéllos portadores de corriente). | ||
Varning! | Denna produkt är beroende av i byggnaden installerat kortslutningsskydd (överströmsskydd). Kontrollera att säkring eller överspänningsskydd används på fasledarna (samtliga strömförande ledare) för internationellt bruk max. 240 V växelström, 16 A (i USA max. 120 V växelström, 15 A). | ||
| |||
| |||
Waarschuwing | Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden. | ||
Varoitus | Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana. | ||
Attention | Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale. | ||
Warnung | Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das Host-Gerät während des normalen Betriebs an Erde gelegt ist. | ||
Avvertenza | Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo. | ||
Advarsel | Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk. | ||
Aviso | Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal. | ||
¡Advertencia! | Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal. | ||
Varning! | Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning. | ||
| |||
| |||
Waarschuwing | Draag tijdens deze procedure aardingspolsbanden om te vermijden dat de kaart beschadigd wordt door elektrostatische ontlading. Raak het achterbord niet rechtstreeks aan met uw hand of met een metalen werktuig, omdat u anders een elektrische schok zou kunnen oplopen. | ||
Varoitus | Käytä tämän toimenpiteen aikana maadoitettuja rannesuojia estääksesi kortin vaurioitumisen sähköstaattisen purkauksen vuoksi. Älä kosketa taustalevyä suoraan kädelläsi tai metallisella työkalulla sähköiskuvaaran takia. | ||
Attention | Lors de cette procédure, toujours porter des bracelets antistatiques pour éviter que des décharges électriques n'endommagent la carte. Pour éviter l'électrocution, ne pas toucher le fond de panier directement avec la main ni avec un outil métallique. | ||
Warnung | Zur Vermeidung einer Beschädigung der Karte durch elektrostatische Entladung während dieses Verfahrens ein Erdungsband am Handgelenk tragen. Bei Berührung der Rückwand mit der Hand oder einem metallenen Werkzeug besteht Elektroschockgefahr. | ||
Avvertenza | Durante questa procedura, indossare bracciali antistatici per evitare danni alla scheda causati da un'eventuale scarica elettrostatica. Non toccare direttamente il pannello delle connessioni, né con le mani né con un qualsiasi utensile metallico, perché esiste il pericolo di folgorazione. | ||
Advarsel | Bruk jordingsarmbånd under prosedyren for å unngå ESD-skader på kortet. Unngå direkte berøring av bakplanet med hånden eller metallverktøy, slik at di ikke får elektrisk støt. | ||
Aviso | Durante este procedimento e para evitar danos ESD causados à placa, use fitas de ligação à terra para os pulsos. Para evitar o risco de choque eléctrico, não toque directamente na parte posterior com a mão ou com qualquer ferramenta metálica. | ||
Advertencia | Usartiras conectadas a tierra en las muñecas durante este procedimiento para evitar daños en la tarjeta causados por descargas electrostáticas. No tocar el plano posterior con las manos ni con ninguna herramienta metálica, ya que podría producir un choque eléctrico. | ||
Varning! | Använd jordade armbandsremmar under denna procedur för att förhindra elektrostatisk skada på kortet. Rör inte vid baksidan med handen eller metallverktyg då detta kan orsaka elektrisk stöt. | ||
| |||
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
![]() |
Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact ![]() 800 553-6387, 408 526-7208, or cs-rep@cisco.com. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed May 24 16:49:31 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.