cc/td/doc
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

VCO/4K Open Programmable Switch

VCO/4K Open Programmable Switch

Product Overview

The VCO/4K is a high density, open programmable switch designed for the deployment of enhanced voice services. The open telephony architecture of this versatile, carrier-class platform allows more than 40 Cisco Voice Application Partners to develop a wide variety of solutions for mixed environment and packet telephony networks, including: enhanced voice services, mixed environment gateways, and Internet offload solutions. This open architecture approach makes rapid deployment of enhanced voice services possible for carriers because they are not required to wait for proprietary solutions developed through a single vendor. Today, Cisco can provide voice solutions that span over 30 application categories. Examples include: unified voice/fax/E-mail communications, pre- and post-paid calling card, single number services, tandem switching, internet offload, operator services, voice dialing, information services, conference calling, web-initiated services and directory assistance.

Key Features and Benefits

Specifications

Hardware
Table 22-46: Technical Specifications for VCO/4K System

Description

Specification

Digital Network Interfaces

T1, E1, ISDN (PRI, NFAS, Euro-ISDNNational ISDN, Custom ISDN, Japanese ISDN, Australia TS014, Q.SIG)

Integrated Service Resources

Integrated prompt and record, DTMF, MF, MFCR2, tone generation, digital conferencing, and call progress analysis

Optional Integrated SS7

ISUP, TUP and TCAP (ITU and ANSI compliant)


Table 22-47: Power Requirements for VCO/4K System

Description

Specification

Optional AC or DC input

Autoranging for worldwide power variations

DC Input

36-72 VDC

AC Input

90-264 VAC, 47-63 Hz


Table 22-48: Physical and Environmental Specifications for VCO/4K System

Description

Specification

Dimensions (H x W x D)

25.25 x 17.5 x 22.625 in. (64.14 x 44.45 x 57.47 cm)

Weight

100-157 lbs fully equipped

Operating Temperature

4.5 to 40°C (40 to 104°F)

Operating Relative Humidity

20 to 80% (non-condensing)


Table 22-49: Regulatory Approvals for VCO/4K System

Description

Specification

Compliance & Certification

Designed and tested for major worldwide requirements including EN55022, EN5082-1, FCC Part 15, FCC Part 68, UL1459, EN60950, CSA C22.2, TS001, INTL CD IEC 950, GR-63-CORE with Zone 4 Earthquake, GR-1089-CORE Safety and Physical Protection (Bellcore NEBS) and 1089, BABT, JATE, and other country-type approvals.


Software

For software information, please see part number table below.

Ordering Information

Product and Part Numbers Table 22-50: Part Numbers for the VCO/4K
Part DescriptionPart Number
Cisco VCO/4K Series of Programmable Switches
VCO/4K System Control and Common Equipment
Basic VCO4K Chassis VCO4K
VCO/4K AC VCO4K-AC
VCO/4K DC VCO4K-DC
Control/Storage/Power Redundancy AC VCO4K-REDUND-AC
Control/Storage/Power Redundancy AC= VCO4K-REDUND-AC=
Control/Storage/Power Redundancy DC VCO4K-REDUND-DC
Control/Storage/Power Redundancy DC VCO4K-REDUND-DC=
VCO Documentation Set VCO4K-DOC
VCO Documentation Set VCO4K-DOC=
19" Rack Mounting Kit VCO4K-RM-19
19" Rack Mounting Kit VCO4K-RM-19=
24" Rack Mounting Kit VCO4K-RM-24
24" Rack Mounting Kit VCO4K-RM-24=
Dual DC Power Feed Option (field installed) VCO4K-DCFEED/2
Dual DC Power Feed Option (factory installed) VCO4K-DCFEED/2=
Ring Generator VCO4K-RING
Ring Generator VCO4K-RING=
VCO Country Adaptation Packages
US/Canada Country Package and Support SFVCO-USA
US/Canada Country Package and Support SFVCO-USA=
Country Adaptation Package and Support for the UK SFVCO-UK
Country Adaptation Package and Support for the UK SFVCO-UK=
Country Adaptation Package and Support for New Zealand SFVCO-NZL
Country Adaptation Package and Support for New Zealand SFVCO-NZL=
Country Adaptation Package and Support for China (PRC) SFVCO-CHN
Country Adaptation Package and Support for China (PRC) SFVCO-CHN=
Country Adaptation Package and Support for Chile SFVCO-CHL
Country Adaptation Package and Support for Chile SFVCO-CHL=
Country Adaptation Package and Support for Finland SFVCO-FIN
Country Adaptation Package and Support for Finland SFVCO-FIN=
Country Adaptation Package and Support for the Netherlands SFVCO-HOL
Country Adaptation Package and Support for the Netherlands SFVCO-HOL=
Country Adaptation Package and Support for Hong Kong SFVCO-HKG
Country Adaptation Package and Support for Hong Kong SFVCO-HKG=
Country Adaptation Package and Support for Brazil SFVCO-B
Country Adaptation Package and Support for Brazil SFVCO-B=
Country Adaptation Package and Support for Belgium SFVCO-BEL
Country Adaptation Package and Support for Belgium SFVCO-BEL=
Country Adaptation Package and Support for Spain SFVCO-E
Country Adaptation Package and Support for Spain SFVCO-E=
Country Adaptation Package and Support for Argentina SFVCO-ARG
Country Adaptation Package and Support for Argentina SFVCO-ARG=
Country Adaptation Package and Support for Germany SFVCO-D
Country Adaptation Package and Support for Germany SFVCO-D=
Country Adaptation Package and Support for France SFVCO-F
Country Adaptation Package and Support for France SFVCO-F=
Country Adaptation Package, and Support for Colombia SFVCO-CLM
Country Adaptation Package, and Support for Colombia SFVCO-CLM=
Country Adaptation Package and Support for Italy SFVCO-I
Country Adaptation Package and Support for Italy SFVCO-I=
Country Adaptation Package and Support for Japan SFVCO-J
Country Adaptation Package and Support for Japan SFVCO-J=
Country Adaptation Package and Support for Singapore SFVCO-SNG
Country Adaptation Package and Support for Singapore SFVCO-SNG=
Country Adaptation Package and Support for Philippines SFVCO-PHL
Country Adaptation Package and Support for Philippines SFVCO-PHL=
Country Adaptation Package and Support for Switzerland SFVCO-SUI
Country Adaptation Package and Support for Switzerland SFVCO-SUI=
Country Adaptation Package and Support for Mexico SFVCO-MES
Country Adaptation Package and Support for Mexico SFVCO-MES=
Country Adaptation Package and Support for South Africa SFVCO-AFS
Country Adaptation Package and Support for South Africa SFVCO-AFS=
Country Adaptation Package and Support for Vietnam SFVCO-VTN
Country Adaptation Package and Support for Vietnam SFVCO-VTN=
Country Adaptation Package and Support for Thailand SFVCO-THA
Country Adaptation Package and Support for Thailand SFVCO-THA=
Country Adaptation Package and Support for Korea SFVCO-KOR
Country Adaptation Package and Support for Korea SFVCO-KOR=
Country Adaptation Package and Support for Australia SFVCO-AUS
Country Adaptation Package and Support for Australia SFVCO-AUS=
Country Adaptation Package and Support for Sweden SFVCO-S
Country Adaptation Package and Support for Sweden SFVCO-S=
Country Adaptation Package and Support for Taiwan SFVCO-TWN
Country Adaptation Package and Support for Taiwan SFVCO-TWN=
Country Adaptation Package and Support for Portugal SFVCO-POR
Country Adaptation Package and Support for Portugal SFVCO-POR=
Country Adaptation Package and Support for Malaysia SFVCO-MLA
Country Adaptation Package and Support for Malaysia SFVCO-MLA=
Country Adaptation Package and Support for Indonesia SFVCO-INDO
Country Adaptation Package and Support for Indonesia SFVCO-INDO=
VCO/2K Line Test Cards
Eight Line Test Card (8LTC) VCO-2K-8LTC
VCO SS7 Interface Equipment
Integrated SS7 Basic System (4 Link, 4K) VCO-SS7
Integrated SS7 Basic System (4 Link, 4K) VCO-SS7=
Integrated SS7 Redundancy (4 Link, 4K) with Fallback Switch VCO-SS7-REDUND
Integrated SS7 Redundancy (4 Link, 4K) with Fallback Switch VCO-SS7-REDUND=
Integrated SS7 8-link Basic Upgrade Kit VCO-SS7-4U8
Integrated SS7 8-link Basic Upgrade Kit VCO-SS7-4U8=
Integrated SS7 8-link Redundancy Upgrade Kit VCO-SS7-REDUND-4U8
Integrated SS7 Hardware Upgrade Kit 2K to 4K VCO-SS7-2KU4K
Integrated SS7 Hardware Upgrade Kit 2K to 4K VCO-SS7-2KU4K=
Integrated SS7 VME Shelf (for use with VCO/20/4K) VCO4K-SS7-SHELF
Integrated SS7 VME Shelf (for use with VCO/20/4K) VCO4K-SS7-SHELF=
VCO Network Interfaces
Interface Controller Card (ICC) VCO-ICC
Interface Controller Card (ICC) VCO-ICC=
Sixteen Span T1 I/O Module (16 Span T1) VCO-IO-T1-16
Sixteen Span T1 I/O Module (16 Span T1) VCO-IO-T1-16=
Eight Span T1 I/O Module (8 Span T1) VCO-IO-T1-8
Eight Span T1 I/O Module (8 Span T1) VCO-IO-T1-8=
Four Span T1 I/O Module (4 Span T1) VCO-IO-T1-4
Four Span T1 I/O Module (4 Span T1) VCO-IO-T1-4=
Sixteen Span E1 I/O Module (16 Span E1) VCO-IO-E1-16
Sixteen Span E1 I/O Module (16 Span E1) VCO-IO-E1-16=
Eight Span E1 I/O Module (8 Span E1) VCO-IO-E1-8
Eight Span E1 I/O Module (8 Span E1) VCO-IO-E1-8=
Four Span E1 I/O Module (4 Span E1) VCO-IO-E1-4
Four Span E1 I/O Module (4 Span E1) VCO-IO-E1-4=
48 KB Drop and Insert Card VCO-48DANDI=
Eight Line Test Card (8LTC) VCO-2K-8LTC
Eight Line Test Card (8LTC) VCO-2K-8LTC=
Drop and Insert Card (V4.2) VCO-DANDI
Drop and Insert Card (V4.2) VCO-DANDI=
8 Port DB-9 I/O Module VCO-IO-DB9-8
8 Port DB-9 I/O Module VCO-IO-DB9-8=
Three Card Line/Trunk I/O Module (RJ21X) VCO-2K-IO-RJ21X
Three Card Line/Trunk I/O Module (RJ21X) VCO-2K-IO-RJ21X=
Single Card Line/Trunk I/O Module (RJ11) VCO-2K-IO-RJ11
Single Card Line/Trunk I/O Module (RJ11) VCO-2K-IO-RJ11=
VCO Service Resources
Service Platform Card (SPC) VCO-SPC
Service Platform Card (SPC) VCO-SPC=
Service Resource Module VCO-SRM
Service Resource Module VCO-SRM=
Integrated Prompt/Record Card 8-Port (IPRC-8) VCO-IPRC-8
Integrated Prompt/Record Card 8-Port (IPRC-8) VCO-IPRC-8=
Integrated Prompt/Record Card 64-Port (IPRC-64) VCO-IPRC-64
Integrated Prompt/Record Card 64-Port (IPRC-64) VCO-IPRC-64=
Integrated Prompt/Record Card 128-Port (IPRC-128) VCO-IPRC-128
Integrated Prompt/Record Card 128-Port (IPRC-128) VCO-IPRC-128=
Subrate Switching Card (SSC) VCO-SSC
Subrate Switching Card (SSC) VCO-SSC=
VCO IPRC Upgrade 64-128 VCO-IPRC-UG64-128=
VCO SS7 Software
Integrated SS7 Basic Software ANSI ISUP - 2K SFVCO-SS7-AISUP
Integrated SS7 Basic Software ANSI ISUP - 2K SFVCO-SS7-AISUP=
Integrated SS7 Redundancy Software ANSI ISUP - 2K SFVCO-SS7R-AISUP
Integrated SS7 Redundancy Software ANSI ISUP - 2K SFVCO-SS7R-AISUP=
Integrated SS7 Basic Software ITU ISUP - 2K SFVCO-SS7-IISUP
Integrated SS7 Basic Software ITU ISUP - 2K SFVCO-SS7-IISUP=
Integrated SS7 Redundancy Software ITU ISUP - 2K SFVCO-SS7R-IISUP
Integrated SS7 Basic Software ITU ISUP - 2K SFVCO-SS7R-IISUP=
Integrated SS7 Basic Software Upgrade ANSI ISUP - 2K to 4K SFVCO-SS7-AISUP-U
Integrated SS7 Basic Software - ANSI TCAP Upgrade SFVCO-SS7-ATCAP-U
Integrated SS7 RedundAncy Software Upgrade ANSI ISUP - 2K-4K SFVCO-SS7R-AISUP-U
Integrated SS7 Redundancy Software - ANSI TCAP Upgrade SFVCO-SS7R-ATCAP-U
Integrated SS7 Basic Software Upgrade ITU ISUP - 2K to 4K SFVCO-SS7-IISUP-U
Integrated SS7 Basic Software - ITU TCAP Upgrade SFVCO-SS7-ITCAP-U
Integrated SS7 Redundancy Software Upgrade ITU ISUP - 2K-4K SFVCO-SS7R-IISUP-U
Integrated SS7 Redundancy Software - ITU TCAP Upgrade SFVCO-SS7R-ITCAP-U
Integrated SS7 Basic Software Japan ISUP - 2K SFVCO-SS7-JISUP
Integrated SS7 Basic Software Japan ISUP - 2K SFVCO-SS7-JISUP=
Integrated SS7 Redundancy Software Japan ISUP - 2K SFVCO-SS7R-JISUP
Integrated SS7 Redundancy Software Japan ISUP - 2K SFVCO-SS7R-JISUP=
Integrated SS7 Basic Software Upgrade Japan ISUP - 2K to 4K SFVCO-SS7-JISUP-U
Integrated SS7 Redundancy Software Upgrade Japan ISUP-2K-4K SFVCO-SS7R-JISUP-U
Integrated SS7 Basic Software China TUP - 2K SFVCO-SS7-CTUP
Integrated SS7 Basic Software China TUP - 2K SFVCO-SS7-CTUP=
Integrated SS7 Redundancy Software China TUP - 2K SFVCO-SS7R-CTUP
Integrated SS7 Redundancy Software China TUP - 2K SFVCO-SS7R-CTUP=
Integrated SS7 Basic Software Upgrade China TUP - 2K to 4K SFVCO-SS7-CTUP-U
Integrated SS7 Redundancy Software Upgrade China TUP - 2K-4K SFVCO-SS7R-CTUP-U
Integrated SS7 Redundancy Software Upgrade China TUP - 2K-4K SFVCO-SS7R-CTUP-U=
VCO4K SS7 Multi SP 1-4 SFVCO-SS7-MSP-1-4
VCO4K SS7 Multi SP 1-4 SFVCO-SS7-MSP-1-4=
VCO4K SS7 Multi SP 5-8 SFVCO-SS7-MSP-5-8
VCO4K SS7 Multi SP 5-8 SFVCO-SS7-MSP-5-8=
VCO System Software
Time License Slot Increments (536 time slots) SFVCO-U536TDM-V51
Time License Slot Increments (536 time slots) SFVCO-U536TDM-V51=
Service Algorithm Package SFVCO-SVCALG-V51
Service Algorithm Package SFVCO-SVCALG-V51=
Ethernet Host Link SFVCO-HOST-V51
Ethernet Host Link SFVCO-HOST-V51=
TeleRouter Application Software SFVCO-TELER-V51
TeleRouter Application Software SFVCO-TELER-V51=
ISDN NFAS Software SFVCO-NFAS-V51
ISDN NFAS Software SFVCO-NFAS-V51=
ISDN D Channels - Group of 4 (4 to 16 per system) SFVCO-4DCH-4
ISDN D Channels - Group of 4 (4 to 16 per system) SFVCO-4DCH-4=
ISDN D Channels - Group of 4 (20 to 32 per system) SFVCO-4DCH-20
ISDN D Channels - Group of 4 (20 to 32 per system) SFVCO-4DCH-20=
ISDN D Channels - Group of 4 (36 to 48 per system) SFVCO-4DCH-36
ISDN D Channels - Group of 4 (36 to 48 per system) SFVCO-4DCH-36=
ISDN D Channels - Group of 4 (52 to 80 per system) SFVCO-4DCH-52
ISDN D Channels - Group of 4 (52 to 80 per system) SFVCO-4DCH-52=
ISDN D Channels - Group of 4 (84 to 112 per system) SFVCO-4DCH-84
ISDN D Channels - Group of 4 (84 to 112 per system) SFVCO-4DCH-84=
ISDN D Channels - Group of 4 (116 and above per system) SFVCO-4DCH-116
ISDN D Channels - Group of 4 (116 and above per system) SFVCO-4DCH-116=
VFEdit Prompt Editing Software SFVCO-EDPROMPT
VFEdit Prompt Editing Software SFVCO-EDPROMPT=
VCO/4K Generic Software v5.1(3) SFVCO4K-5.1.3
VCO/4K Generic Software v5.1(3) SFVCO4K-5.1.3=
VCO/4K Generic Software 5.1.2 SFVCO4K-5.1.2
VCO/4K Generic Software 5.1.2 SFVCO4K-5.1.2=
VCO Peripherals and Cables
VDT - (110VAC, US Approved) VCO-VDT
VDT - (110VAC, US Approved) VCO-VDT=
Modem (110VAC, US Approved) VCO-MDM
Modem (110VAC, US Approved) VCO-MDM=
Parallel Printer (110VAC, US Approved) VCO-PRINT
Parallel Printer (110VAC, US Approved) VCO-PRINT=
SCSI cable for IPRC CAB-IPRC-SCSI
SCSI cable for IPRC CAB-IPRC-SCSI=
Switch A/B RS232C (modem) VCO-A/B-MOD-110
Switch A/B RS232C (Modem) VCO-A/B-MOD-110=
Switch A/B RS232C (Terminal/Printer) VCO-A/B-PRTM-110
Switch A/B RS232C (Terminal/Printer) VCO-A/B-PRTM-110=
Switch A/B RS232C 220V (modem) VCO-A/B-MOD-220
Switch A/B RS232C (Modem) 220V VCO-A/B-MOD-220=
Switch A/B RS232C 220V (Terminal/Printer) VCO-A/B-PRTM-220
Switch A/B RS232C (Terminal/Printer) 220V VCO-A/B-PRTM-220=
Cable AAC/Dataprobe A/B S/W (VCO/20) CAB-VCO4K-A/B
Cable AAC/Dataprobe A/B S/W (VCO/20) CAB-VCO4K-A/B=
Cable Drop and Insert - DB9 CAB-VCO-DANDI-DB9
Cable Drop and Insert - DB9 CAB-VCO-DANDI-DB9=
Cable 25 Line Shielded M-M 25 FT CAB-RS232-25MM
Cable 25 Line Shielded M-M 25 FT CAB-RS232-25MM=
Cable 25 Line Shielded M-F 25 FT CAB-RS232-25MF
Cable 25 Line Shielded M-F 25 FT CAB-RS232-25MF=
Cable 9 Line Shielded M-M 25 FT CAB-RS232-9MM
Cable 9 Line Shielded M-M 25 FT CAB-RS232-9MM=
Centronics Printer Cable CAB-CENT/CENT
Centronics Printer Cable CAB-CENT/CENT=
Cable Centronics - DB25 M/M 15 FT CAB-CENT/DB25
Cable Centronics - DB25 M/M 15 FT CAB-CENT/DB25=
Integrated SS7 Terminal Adapter Kit (WY-520) VCO-SS7-TERM
Integrated SS7 Terminal Adapter Kit (WY-520) VCO-SS7-TERM=
VCO Spares and Accessories
VCO Documentation Set VCO4K-DOC=
Ring Generator VCO4K-RING=
US/Canada Country Package and Support SFVCO-USA=
Country Adaptation Package and Support for the UK SFVCO-UK=
Country Adaptation Package and Support for New Zealand SFVCO-NZL=
Country Adaptation Package and Support for China (PRC) SFVCO-CHN=
Country Adaptation Package and Support for Chile SFVCO-CHL=
Country Adaptation Package and Support for Finland SFVCO-FIN=
Country Adaptation Package and Support for the Netherlands SFVCO-HOL=
Country Adaptation Package and Support for Hong Kong SFVCO-HKG=
Country Adaptation Package and Support for Brazil SFVCO-B=
Country Adaptation Package and Support for Belgium SFVCO-BEL=
Country Adaptation Package and Support for Spain SFVCO-E=
Country Adaptation Package and Support for Argentina SFVCO-ARG=
Country Adaptation Package and Support for Germany SFVCO-D=
Country Adaptation Package and Support for France SFVCO-F=
Country Adaptation Package, and Support for Colombia SFVCO-CLM=
Country Adaptation Package and Support for Italy SFVCO-I=
Country Adaptation Package and Support for Japan SFVCO-J=
Country Adaptation Package and Support for Singapore SFVCO-SNG=
Country Adaptation Package and Support for Philippines SFVCO-PHL=
Country Adaptation Package and Support for Switzerland SFVCO-SUI=
Country Adaptation Package and Support for Mexico SFVCO-MES=
Country Adaptation Package and Support for South Africa SFVCO-AFS=
Country Adaptation Package and Support for Vietnam SFVCO-VTN=
Country Adaptation Package and Support for Thailand SFVCO-THA=
Country Adaptation Package and Support for Korea SFVCO-KOR=
Country Adaptation Package and Support for Australia SFVCO-AUS=
Country Adaptation Package and Support for Sweden SFVCO-S=
Country Adaptation Package and Support for Taiwan SFVCO-TWN=
Country Adaptation Package and Support for Portugal SFVCO-POR=
Country Adaptation Package and Support for Malaysia SFVCO-MLA=
Integrated SS7 Basic System (4 Link, 4K) VCO-SS7=
Integrated SS7 Redundancy (4 Link, 4K) with Fallback Switch VCO-SS7-REDUND=
Integrated SS7 8-link Basic Upgrade Kit VCO-SS7-4U8=
Integrated SS7 Hardware Upgrade Kit 2K to 4K VCO-SS7-2KU4K=
Integrated SS7 Terminal Adapter Kit (WY-520) VCO-SS7-TERM=
Interface Controller Card (ICC) VCO-ICC=
Sixteen Span T1 I/O Module (16 Span T1) VCO-IO-T1-16=
Eight Span T1 I/O Module (8 Span T1) VCO-IO-T1-8=
Four Span T1 I/O Module (4 Span T1) VCO-IO-T1-4=
Sixteen Span E1 I/O Module (16 Span E1) VCO-IO-E1-16=
Eight Span E1 I/O Module (8 Span E1) VCO-IO-E1-8=
Four Span E1 I/O Module (4 Span E1) VCO-IO-E1-4=
Drop and Insert Card (V4.2) VCO-DANDI=
8 Port DB-9 I/O Module VCO-IO-DB9-8=
48 KB Drop and Insert Card VCO-48DANDI=
Eight Line Test Card (8LTC) VCO-2K-8LTC=
C-Bus Termination Kit VCO-CBUS=
Service Platform Card (SPC) VCO-SPC=
Service Resource Module VCO-SRM=
Integrated Prompt/Record Card 8-Port (IPRC-8) VCO-IPRC-8=
Integrated Prompt/Record Card 64-Port (IPRC-64) VCO-IPRC-64=
Integrated Prompt/Record Card 128-Port (IPRC-128) VCO-IPRC-128=
VCO IPRC Upgrade 64-128 VCO-IPRC-UG64-128=
Digital Tone Generator Card (DTG2) VCO-DTG=
Subrate Switching Card (SSC) VCO-SSC=
Three Card Line/Trunk I/O Module (RJ21X) VCO-2K-IO-RJ21X=
Single Card Line/Trunk I/O Module (RJ11) VCO-2K-IO-RJ11=
Integrated SS7 Basic Software ANSI ISUP - 2K SFVCO-SS7-AISUP=
Integrated SS7 Redundancy Software ANSI ISUP - 2K SFVCO-SS7R-AISUP=
Integrated SS7 Basic Software ITU ISUP - 2K SFVCO-SS7-IISUP=
Integrated SS7 Basic Software ITU ISUP - 2K SFVCO-SS7R-IISUP=
ASIST API SFVCO-ASIST-API=
ASIST Ethernet SFVCO-ASIST-ENET=
Network Bus Controller 3 VCO-NBC3=
CPU 16 Megabyte (VME 68030 Processor) VCO-CPU16MB=
System Spares Kit VCO/4K VCO4K-SYS=
SWI/Floppy/Carrier Assembly VCO4K-SWI=
Storage/Control I/O VCO4K-STOR/IO=
Alarm Arbiter Card VCO4K-AAC=
Alarm Arbiter Interface Card VCO4K-AAIC=
Power supply Module DC VCO4K-PWR-DC=
Power supply Module AC VCO4K-PWR-AC=
Fan Module VCO/20 VCO4K-FAN=
Spare Fuse Kit VCO4K-FUSE=
Integrated SS7 hardware Spares Kit -4K VCO-SS7-SYS=
Integrated SS7 Redundancy Spares Kit (SPARC5/4 Link) VCO-SS7/2-SYS=
Integrated SS7 Fallback Switch Power Supply VCO-SS7-FB-PWR=
Integrated SS7 VME Shelf Power Supply Spare VCO-SS7-VME-PWR=
SCSI cable for IPRC CAB-IPRC-SCSI=
Switch A/B RS232C (Modem) VCO-A/B-MOD-110=
Switch A/B RS232C (Terminal/Printer) VCO-A/B-PRTM-110=
Switch A/B RS232C (Modem) 220V VCO-A/B-MOD-220=
Switch A/B RS232C (Terminal/Printer) 220V VCO-A/B-PRTM-220=
Cable AAC/Dataprobe A/B S/W (VCO/20) CAB-VCO4K-A/B=
Cable Drop and Insert - DB9 CAB-VCO-DANDI-DB9=
Time License Slot Increments (536 time slots) SFVCO-U536TDM-V51=
Service Algorithm Package SFVCO-SVCALG-V51=
VCO/4K 8LTC Japan Upgrade SFVCO-8LTC-JPN-UG=
Ethernet Host Link SFVCO-HOST-V51=
TeleRouter Application Software SFVCO-TELER-V51=
ISDN Primary Rate Software (Custom) SFVCO-PRI-V51=
ISDN NFAS Software SFVCO-NFAS-V51=
ISDN D Channels - Group of 4 (4 to 16 per system) SFVCO-4DCH-4=
ISDN D Channels - Group of 4 (20 to 32 per system) SFVCO-4DCH-20=
ISDN D Channels - Group of 4 (36 to 48 per system) SFVCO-4DCH-36=
ISDN D Channels - Group of 4 (52 to 80 per system) SFVCO-4DCH-52=
ISDN D Channels - Group of 4 (84 to 112 per system) SFVCO-4DCH-84=
ISDN D Channels - Group of 4 (116 and above per system) SFVCO-4DCH-116=
VFEdit Prompt Editing Software SFVCO-EDPROMPT=
Integrated SS7 Basic Software Upgrade ANSI ISUP - 2K to 4K SFVCO-SS7-AISUPU=
Integrated SS7 Basic Software - ANSI TCAP Upgrade SFVCO-SS7-ATCAPU=
Integrated SS7 RedundAncy Software Upgrade ANSI ISUP - 2K-4K SFVCO-SS7R-AISUPU=
Integrated SS7 Redundancy Software - ANSI TCAP Upgrade SFVCO-SS7R-ATCAPU=
Integrated SS7 Basic Software Upgrade ITU ISUP - 2K to 4K SFVCO-SS7-IISUPU=
Integrated SS7 Basic Software - ITU TCAP Upgrade SFVCO-SS7-ITCAPU=
Integrated SS7 Redundancy Software Upgrade ITU ISUP - 2K-4K SFVCO-SS7R-IISUPU=
Integrated SS7 Redundancy Software - ITU TCAP Upgrade SFVCO-SS7R-ITCAPU=
VDT - (110VAC, US Approved) VCO-VDT=
Parallel Printer (110VAC, US Approved) VCO-PRINT=
Modem (110VAC, US Approved) VCO-MDM=
VCO4K Cisco Chassis FP Blank Plate VCO4K-BLANK=
VCO4K Cisco Chassis Doc set VCO4K-DOC-C=
Spare Fan Tray-Cisco VCO4K chassis VCO4K-FAN-C=

hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Sep 27 05:15:38 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.