Cisco MGX 8850 — Wide-Area IP+ATM Switch

Product Overview

The Cisco MGX 8850 wide-area IP+ATM enables delivery of a complete portfolio of differentiated service offerings while scaling from DS0 to OC-48c/STM-16 speeds. Its deployment flexibility provides the agility for service providers to be first to market with the services that customers demand and to deploy MPLS enabled ATM networks up to OC-48c speeds.


Note The Cisco MGX 8850 can function in multiple modes of operation. The Cisco MGX 8850 PXM-1 configuration can operate as a stand-alone device or as a integrated feeder for the BPX 8600. The Cisco MGX 8850 PXM-45 configuration includes the 45 Gbps switch card and broadband ATM modules. Contact your Cisco account representative for General Availability information.

Key Features and Benefits

The Cisco MGX 8850 universal chassis provides a unified IP+ATM architecture that cost-effectively delivers a complete portfolio of differentiated services - from circuit emulation services tIP virtual private networks (VPNs) - on a single chassis, and enables service providers to add new services as markets dictate. Features and benefits include:

Specifications

Hardware

Mechanical Configuration

The Cisco MGX 8850 platform can be configured with a choice of switching fabrics. The same backplane is used with different switching fabric cards to achieve scalability. The Cisco MGX 8850 base system includes a chassis capable of supporting a maximum of 24 single height I/O slots. The chassis can be configured to support 24 single height I/O slots, 12 double height I/O slots, or an even numbered combination of single and double height slots ranging from 12 double height service modules with zero single height to 24 single height service modules with zero double height. Single height to double height slot conversions must occur in increments of two slots wide. The Cisco MGX 8850 chassis also has two additional double height slots reserved for PXMs, and four additional single height (or two double height) slots dedicated and reserved for SRMs. By default, a chassis with empty slots is shipped configured for single height cards. Dividers must be removed from slot pairs 1-2, 3-4, 5-6, 9-10, 11-12, or 13-14 for the addition of double height cards.

Table 20-148: Technical Specifications for Cisco MGX 8850

Description

Specification

Switching Card Options

1.2 Gbps shared memory fabric (PXM-1)

45 Gbps crosspoint fabric (PXM-45)

Broadband ATM Interfaces

Sixteen port T3 and E3

Sixteen port OC-3c/STM-1

Four port OC-12c/STM-4

One port OC-48c-STM-16

Frame Interfaces

Eight port T1 and channelized T1

Eight port E1 and channelized E1

Two Port T3 and E3 unchannelized

Two Port channelized T3

Two Port HSSI

ATM Interfaces

Eight port T1 and channelized T1

Eight port E1 and channelized E1

Circuit Emulation Interfaces

Eight port T1 and channelized T1

Eight port E1 and channelized E1

One port T3 unchannelized

One port E3 unchannelized

LAN Interfaces

Ethernet

Fast Ethernet

Fiber Digital Distributed Interface (FDDI)

Voice

Voice interworking service module

Optional Redundancy

All components are optionally redundant to 100-percent system redundancy, including the control processor, switching fabric, network interfaces, service interfaces, critical backplane signals, power supplies, power modules, and cooling fans.

Node Synchronization

Internal Stratum-3 clock source

Internal Stratum-4E

External T1/E1 BITS source

External source received inband over the network

Synchronization to software-programmable primary and secondary sources, with automatic switchover


Table 20-149: Power Requirements for Cisco MGX 8850

Description

Specification

Input power required

-48 VDC

Optional AC powering


Table 20-150: Physical and Environmental Specifications for Cisco MGX 8850

Description

Specification

Dimensions (H x W x D)

28 x 17.72 x 21.5 in. (75.6 x 45.0 x 54.6 cm)

Rack mountable in 19-in. and 23-in. EIA/RETMA and ETSI racks


Table 20-151: Regulatory Approvals for Cisco MGX 8850

Description

Specification

EMI/ESD compliance

FCC Part 15

Bellcore GR1089-CORE

IEC 801-2

EN55022

Safety compliance

EN 60950

UL 1950

Bellcore NEBS: Level 3-compliant

Optical safety: IEC 825-1 (Class 1)


Network Management

Software

For more information on software for the Cisco MGX 8850, see Ordering Information below.

Ordering Information

Product and Part Numbers Table 20-152: Part Numbers for the Cisco MGX 8850
Part DescriptionPart Number
MGX 8800 WAN Edge Switch
MGX 8850, 24 I/O+4 SRM slots, PXM1, PXM-UI, Cooling, 19 MGX8850
MGX 8800 Cabinets
STRATM - Cabinet STRATM-CAB
STRATM - Unconfigured Cabinet STRATM-CAB=
STRATM - Cable Management Option STRATM-CMGMT=
STRATM - Kit of Four Side Panels STRATM-SP
STRATM - Kit of Four Side Panels STRATM-SP=
STRATM - Rear Door STRATM-RDOOR
STRATM - Rear Door STRATM-RDOOR=
STRATM - Stability Plate Option STRATM-STAB=
MGX 8800 Processor Switching Modules
1 PXM45, 1 PXM-UI-S3, 1 PXM-HD in system PXM45
45Gbps processor/fabric, PXM45 (no PXM-UI-S3 or PXM-HD) PXM45=
2 PXM45, 2 PXM-UI-S3, 2 PXM-HD in system PXM45-R
Redundant PXM1, PXM1-UI, no broadband ports PXM1-R
PXM1 (no PXM1-UI or broadband ports) PXM1=
PXM1, 2 T3 or E3 broadband ports (upgrade of PXM1) PXM1-2-T3E3
PXM1 2 T3 or E3 broadband ports PXM1-2-T3E3=
Redundant PXM1-2-T3E3, PXM1-UI (inc upgrade of the first PXM1 PXM1-2-T3E3-R
PXM1, 4 155 Mbps broadband ports (upgrade of PXM1) PXM1-4-155
PXM1,4 155 Mbps broadband ports PXM1-4-155=
Redundant PXM1-4-155, PXM1-UI (inc upgrade of the first PXM1 PXM1-4-155-R
PXM1, 1 622 Mbps broadband port (upgrade of PXM1) PXM1-1-622
PXM1, 1 622 Mbps broadband port PXM1-1-622=
Redundant PXM1-1-622, PXM1-UI (inc upgrade of the first PXM1 PXM1-1-622-R
PXM User Interface Back Card PXM-UI=
MGX 8800 Processor Switching Module Back Cards
PXM User Interface Back Card with Stratum3 Clock PXM-UI-S3=
PXM Hard Disk BackCard PXM-HD=
Two Port T3 back card, BNC connectors MGX-BNC-2T3
MGX 2 port T3 back card, BNC connectors MGX-BNC-2T3=
Two Port E3 back card (grounded), BNC connectors MGX-BNC-2E3
MGX 2 port E3 back card, BNC connectors MGX-BNC-2E3=
Two Port E3 back card (ungrounded), BNC connectors MGX-BNC-2E3A
MGX 2 Port E3 Back Card, BNC Connectors - AU Compliant MGX-BNC-2E3A=
PXM1 4 port 155 Mbps Back Card, MMF, SC connectors MGX-MMF-4-155/B
PXM1 4 port 155 Mbps Back Card, MMF, SC connectors MGX-MMF-4-155/B=
PXM1 4 port 155 Mbps Back Card, SMF-IR, SC connectors MGX-SMFIR-4-155/B
PXM1 4 port 155 Mbps Back Card, SMF-IR, SC connectors MGX-SMFIR-4-155/B=
PXM1 4 port 155 Mbps Back Card, SMF-LR, SC connectors MGX-SMFLR-4-155/B
PXM1 4 port 155 Mbps Back Card, SMF-LR, SC connectors MGX-SMFLR-4-155/B=
PXM1 1 port 622 Mbps Back Card, SMF-IR, SC connectors MGX-SMFIR-1-622/B
PXM1 1 port 622 Mbps Back Card, SMF-IR, SC connectors MGX-SMFIR-1-622/B=
PXM1 1 port 622 Mbps Back Card, SMF-LR, SC connectors MGX-SMFLR-1-622/B
PXM1 1 port 622 Mbps Back Card, SMF-LR, SC connectors MGX-SMFLR-1-622/B=
MGX 8800 Broadband ATM Service Modules
Double-height ATM Service module, 16 T3s/E3s AXSM-16-T3E3
Double-height ATM Service module, 16 T3s/E3s AXSM-16-T3E3=
Double-height ATM Service module, 16 OC-3c/STM-1c AXSM-16-155
Double-height ATM Service module, 16 OC-3c/STM-1c AXSM-16-155=
Double-height ATM Service module, 4 OC-12c/STM-4c AXSM-4-622
Double-height ATM Service module, 4 OC-12c/STM-4c AXSM-4-622=
Double-height ATM Service module, 1 OC-48c/STM-16c AXSM-1-2488
Double-height ATM Service module, 1 OC-48c/STM-16c AXSM-1-2488=
MGX 8800 Service Resource Modules
Service Resource Module with 3 Channelized T3 ports MGX-SRM-3T3/B
Service Resource Module with 3 Channelized T3 ports MGX-SRM-3T3/B=
Back Card for the MGX-SRM-3T3 MGX-BNC-3T3-M
Back Card for the AX-SRM-3T3 in the MGX 8850 MGX-BNC-3T3-M=
MGX 8800 SRM Software/Feature Licenses
MGX 1 for N T1/E1 SM Red License for SRM on MGX 8800 & 8220 AX-SR-8
MGX 8850&8220 1:N Red Licence for SRM spare cards AX-SR-8=
MGX 8800 Route Processor Modules
Route Processor Module - 128 Meg of DRAM MGX-RPM-128M/B
Route Processor Module - 128 Meg of DRAM MGX-RPM-128M/B=
MGX 8800 RPM Software/Feature Licenses
MGX IP only Software Set for RPM - Required for RPM MGX-RPM-IP
MGX Netflow License for RPM MGX-RPM-NF
MGX InterDomain Routing and MPLS License for RPM MGX-FR-IR72
MGX 8800 Route Processor Module Back Cards
Fast Ethernet Back Card for the RPM, RJ45 connector MGX-RJ45-FE
Fast Ethernet Back Card for the RPM, RJ45 connector MGX-RJ45-FE=
Fast Ethernet Back Card for the RPM, MMF connector MGX-MMF-FE
Fast Ethernet Back Card for the RPM, MMF connector MGX-MMF-FE=
4 port Ethernet Back Card for the RPM MGX-RJ45-4E
4 port Ethernet Back Card for the RPM MGX-RJ45-4E=
FDDI Back Card for the RPM, MMF MGX-MMF-FDDI=
FDDI Back Card for the RPM, SMF MGX-SMF-FDDI=
FDDI Full Duplex Back Card for the RPM, MMF MGX-MMF-FDDI/FD=
FDDI Full Duplex Back Card for the RPM, SMF MGX-SMF-FDDI/FD=
MGX 8800 Frame Service Modules
Frame Service Module, Eight Fractional E1 Ports AX-FRSM-8E1
Frame Service Module, Eight Fractional E1 Ports AX-FRSM-8E1=
Frame Service Module, Eight Channelized E1 Ports AX-FRSM-8E1-C
Frame Service Module, Eight Channelized E1 Ports AX-FRSM-8E1-C=
Frame Service Module, Eight Fractional T1 Ports AX-FRSM-8T1
Frame Service Module, Eight Fractional T1 Ports AX-FRSM-8T1=
Frame Service Module, Eight Channelized T1 Ports AX-FRSM-8T1-C
Frame Service Module, Eight Channelized T1 Ports AX-FRSM-8T1-C=
Frame Service Module, Serial Interface MGX-FRSM-HS1/B
Frame Service Module, Serial Interface MGX-FRSM-HS1/B=
Frame Service Module, High-speed Serial version 2 MGX-FRSM-HS2
Frame Service Module, High-speed Serial version 2 MGX-FRSM-HS2=
Frame Service Module, Two T3 Channelized Ports MGX-FRSM-2CT3
Frame Service Module, Two Channelized T3 Ports MGX-FRSM-2CT3=
Frame Service Module, Two T3 or E3 Non-Channelized Ports MGX-FRSM-2T3E3
Frame Service Module, Two T3 or E3 Ports MGX-FRSM-2T3E3=
MGX 8800 FRSM Software/Feature Licenses
MGX ForeSight License for each FRSM-8 AX-FS-8
MGX ForeSight License for each FRSM-8 AX-FS-8=
MGX ForeSight License for each FRSM-HS1, HS2, 2T3E3, 2CT3 AX-FS-HS
MGX ForeSight License for each FRSM-HS1, HS2, 2T3E3, 2CT3 AX-FS-HS=
MGX 8800 Circuit Emulation Service Modules
Circuit Emulation Service Module, Eight E1 Ports AX-CESM-8E1
Circuit Emulation Service Module, Eight E1 Ports AX-CESM-8E1=
Circuit Emulation Service Module, Eight T1 Ports AX-CESM-8T1
Circuit Emulation Service Module, Eight T1 Ports AX-CESM-8T1=
MGX 8800 CESM Software/Feature Licenses
MGX Structured Data Transfer License for each CESM-8 AX-SDT-8
Structured Data Transfer license for 8-port CESMs AX-SDT-8=
MGX 8800 ATM UNI Service Modules
ATM UNI Service Module, Eight E1 Ports MGX-AUSM-8E1/B
ATM UNI Service Module, Eight E1 Ports MGX-AUSM-8E1/B=
ATM UNI Service Module, Eight T1 Ports MGX-AUSM-8T1/B
ATM UNI Service Module, Eight T1 Ports MGX-AUSM-8T1/B=
MGX 8800 Voice Interworking Service Modules
8 Port E1 Voice Card MGX-VISM-8E1
8 Port E1 Voice Card MGX-VISM-8E1=
Voice Interworking Service Module, Eight T1 Ports MGX-VISM-8T1
Voice Interworking Service Module, Eight T1 Ports MGX-VISM-8T1=
MGX 8800 VISM Software Licenses
MGX VoIP Base (G.711) Licensing fee for VISM-8 MGX-VOIP-BASE
VISM VoAAL2 Base Software License (G.711, VAD, ECAN) MGX-VOAAL2-BASE
VISM VoAAL2 Base Software License (G.711, VAD, ECAN) MGX-VOAAL2-BASE=
VISM VoAAL2 Base Software License (G.711and G.726-32K ADPCM) MGX-VOAAL2-ENH1
VISM VoAAL2 Base Software License (G.711and G.726-32K ADPCM) MGX-VOAAL2-ENH1=
VISM VoAAL2 Software License (G.711, G.729-8K CS-ACELP) MGX-VOAAL2-ENH2
VISM VoAAL2 Software License (G.711, G.729-8K CS-ACELP) MGX-VOAAL2-ENH2=
VISM VoAAL2 Software License (G.711, G.726-32K, G.729a-8K) MGX-VOAAL2-ENH3
VISM VoAAL2 Software License (G.711, G.726-32K, G.729a-8K) MGX-VOAAL2-ENH3=
VISM Software Release 1.5(01) MGX-VISM-SW1501
VISM Software Release 1.5(02) MGX-VISM-SW1502
VISM Software Release 1.5(03) MGX-VISM-SW1503
MGX 8800 Service Modules Back Cards
8 T3 single height back card, SMB SMB-8-T3
8 T3 single height back card, SMB SMB-8-T3=
8 E3 single height back card, SMB SMB-8-E3
8 E3 single height back card, SMB SMB-8-E3=
8 OC-3c/STM-1c single height back card, MMF, MT-RJ MMF-8-155-MT
8 OC-3c/STM-1c single height back card, MMF, MT-RJ MMF-8-155-MT=
8 OC-3c/STM-1c single height back card, SMF-IR, LC SMFIR-8-155-LC
8 OC-3c/STM-1c single height back card, SMF-IR, LC SMFIR-8-155-LC=
8 OC-3c/STM-1c single height back card, SMF-LR, LC SMFLR-8-155-LC
8 OC-3c/STM-1c single height back card, SMF-LR, LC SMFLR-8-155-LC=
2 OC-12c/STM-4c single height back card, SMF-IR, SC SMFIR-2-622
2 OC-12c/STM-4c single height back card, SMF-IR, SC SMFIR-2-622=
2 OC-12c/STM-4c single height back card, SMF-LR, SC SMFLR-2-622
2 OC-12c/STM-4c single height back card, SMF-LR, SC SMFLR-2-622=
1 OC-48c/STM-16c single height back card, SMF-SR, SC SMFSR-1-2488
1 OC-48c/STM-16c single height back card, SMF-SR, SC SMFSR-1-2488=
1 OC-48c/STM-16c single height BC, SMFLR, SC connectors SMFLR-1-2488
1 OC-48c/STM-16c single height BC, SMFLR, SC connectors SMFLR-1-2488=
1 OC-48c/STM-16c single height back card, SMF-XLR, SC SMFXLR-1-2488
1 OC-48c/STM-16c single height back card, SMF-XLR, SC SMFXLR-1-2488=
Eight Port E1 Back Card with SMB Connectors AX-SMB-8E1
Eight Port E1 Back Card with SMB Connectors AX-SMB-8E1=
Eight Port E1 Back Card with RJ48 Connectors AX-RJ48-8E1
Eight Port E1 Back Card with RJ48 Connectors AX-RJ48-8E1=
Eight Port T1 Back Card with RJ48 Connectors AX-RJ48-8T1
Eight Port T1 Back Card with RJ48 Connectors AX-RJ48-8T1=
Redundancy Back Card for AX-SMB-8E1 AX-R-SMB-8E1
Redundancy Back Card for AX-SMB-8E1 AX-R-SMB-8E1=
Redundancy Back Card for AX-RJ48-8E1 AX-R-RJ48-8E1
Redundancy Back Card for AX-RJ48-8E1 AX-R-RJ48-8E1=
Redundancy Back Card for AX-RJ48-8T1 AX-R-RJ48-8T1
Redundancy Back Card for AX-RJ48-8T1 AX-R-RJ48-8T1=
Four port V.35 back card for MGX-FRSM-HS1/B MGX-12IN1-4S
4-port V.35 back card, spare version MGX-12IN1-4S=
Two Port HSSI back card, SCSI-2 connectors MGX-SCSI2-2HSSI/B
Two Port HSSI back card, SCSI-2 connectors MGX-SCSI2-2HSSI/B=
Two Port T3 back card, BNC connectors MGX-BNC-2T3
MGX 2 port T3 back card, BNC connectors MGX-BNC-2T3=
Two Port E3 back card (grounded), BNC connectors MGX-BNC-2E3
MGX 2 port E3 back card, BNC connectors MGX-BNC-2E3=
Two Port E3 back card (ungrounded), BNC connectors MGX-BNC-2E3A
MGX 2 Port E3 Back Card, BNC Connectors - AU Compliant MGX-BNC-2E3A=
MGX 8800 Power Cords
Power Cord with AS 3112 plug (Australia and New Zealand) PWRCD-ANZ=
Power Cord with CEE 7/7 plug (Continental Europe) PWRCD-EU=
Power Cord with BS 1363 plug (Great Britain and Ireland) PWRCD-GBI=
Power Cord with CEI 23-16/VII plug (Italy) PWRCD-IT=
Power Cord with NEMA L6-20 Twistlock plug (North America and PWRCD-NA=
MGX 8800 Power Supplies and Accessories
NR AC system for MGX 8850:AC Shelf,1 feed,1 PS,1 MGX-CAB-AC/ MGX-AC1-1
NR AC system for MGX 8850:AC Shelf,1 feed,1 PS,1 MGX-CAB-A MGX-AC1-1=
Red AC pwr,red AC feed,AC Shelf,2 PS,2 MGX-CAB-AC/DC MGX-AC2-2
Red AC pwr,red AC feed,AC Shelf,2 PS,2 MGX-CAB-AC MGX-AC2-2=
1200 Watt Power Supply for AC Systems PS-1200-AC=
MGX 8850 DC PEM and MGX-CAB-AC/DC MGX-DC
MGX 8850 DC PEM MGX-DC=
Cisco 8850 AC Shelf, Single feed MGX-AC-RACK1=
Cisco 8850 AC Shelf, Dual feed MGX-AC-RACK2=
MGX 8850 Cable Management MGX-CAB-MGMT
MGX 8850 Cable Management MGX-CAB-MGMT=
Cable to Connect MGX 8850 AC or DC shelf to MGX 8850 Chassis MGX-CAB-AC/DC=
110v AC Tray and intake MGX-AC-110
110v AC Tray and intake MGX-AC-110=
Intake + DC PEM which is 2U in size MGX-DC-2U
MGX 8800 Cooling Group
Intake and Outtake Plenums for MGX 8850 MGX-PLENUM=
MGX 8850 Spacer for PXM1 System MGX-FAN-SPACER=
MGX 8850 Fan Tray MGX-FAN
MGX 8850 spare fan tray;Required for PXM2 upgrade MGX-FAN=
MGX Fan Cable MGX-FAN-CAB
MGX FAN spare cable MGX-FAN-CAB=
MGX 8800 Spares and Accessories
MGX 8850 Chassis MGX8850-CH=
MGX 8850 Door MGX8850-DOOR
MGX 8850 Door MGX8850-DOOR=
Single height front card slot cover for the MGX SMs SINGLE SM-CVR
Single height front card slot cover for the MGX SMs SINGLE SM-CVR=
Single height front card slot cover for the MGX SRM SRM-CVR
Single height front card slot cover for the MGX SRM SRM-CVR=
Double height front card slot cover for the MGX Processor PROCESSOR CVR
Double height front card slot cover for the MGX Processor PROCESSOR CVR=
Double height front card slot cover for the MGX Processors DOUBLE SM-CVR
Double height front card slot cover for the MGX Processors DOUBLE SM-CVR=
Mounting kit to install Cisco 8850 chassis in a 23" rack MGX-MNT23
Mounting kit to install Cisco 8800 chassis in a 23" rack MGX-MNT23=
Backplane kit MGX-RTROFIT-KIT
Circuit Emulation Service Module, One T3 or E3 Port MGX-CESM-T3E3
Circuit Emulation Service Module, One T3 or E3 Port MGX-CESM-T3E3=
Redundant PXM45 and PXM45-UI PXM45-R-BUND
MGX 8800 Cables
DB15/Y Cable /M15-F15 10ft CAB-5607-10
DB15/Y Cable /M15-F15 10ft CAB-5607-10=
ASSY CBL SMB(M) TO BNC(F) "Y" CABLE, 5 "CAB-5681-06
ASSY CBL SMB(M) to BNC(F) "Y" CABLE, 5.5 "CAB-5681-06=
ASSY CBL SMB(M) TO BNC(F), 6 "CAB-5682-06=
^ASSY CBL RJ48(M) to DB9(F), 6 "CAB-5683-06
^ASSY CBL RJ48(M) to DB9(F), 18 "CAB-5683-18
ASSY CBL RJ48(M) to RJ48(F) "Y" CABLE, 4 "CAB-5686-04
ASSY CBL RJ48(M) to RJ48(F) "Y" CABLE, 4 "CAB-5686-04=
ASSY CBL RJ48(M) to RJ48(F) "Y" CABLE, 6 "CAB-5686-06
ASSY CBL RJ48(M) to RJ48(F) "Y" CABLE, 6 "CAB-5686-06=
ASSY CBL DB15(M) to RJ48(F) CAB-5687-06=
ASSY CBL DB15(M) to RJ48(F) CAB-5687-08=
ASSY CBL RJ48(M) TO DB9(F), 6 CAB-5688-06
ASSY CBL RJ48(M) TO DB9(F), 6 CAB-5688-06=
ASSY CBL RJ48(M) TO DB9(F), 18 CAB-5688-18
ASSY CBL RJ48(M) TO DB9(F), 18 CAB-5688-18=
ASSY CBL RJ48(M) TO DB9(F) CAB-5689-06
ASSY CBL RJ48(M) TO DB9(F) CAB-5689-06=
ASSY CBL RJ48(M) TO DB9(F) CAB-5689-18
ASSY CBL RJ48(M) TO DB9(F) CAB-5689-18=
Y-cable for supporting 1:1 redundancy of the SCSI2 module CAB-SCSI2-Y=
MGX 8800 Software Licenses/Kits
MGX 8850 Syst Software License - Release (Version 1.1.11) MGX8850-SW-1111
MGX 8850 Syst Software License - Spare CD (Version 1.1.11) MGX8850-SW-1111CD=
MGX 8850 Syst Software License-PXM Spare (Version 1.1.11) MGX8850SW-1111
MGX 8850 Syst Software License - Release (Version 1.1.12) MGX8850-SW-1112
MGX 8850 Syst Software License - Spare CD (Version 1.1.12) MGX8850-SW-1112CD=
MGX 8850 Syst Software License-PXM Spare (Version 1.1.12) MGX8850SW-1112
MGX 8850 Syst Software License - Release (Version 1.1.21) MGX8850-SW-1121
MGX 8850 Syst Software License - Spare CD (Version 1.1.21) MGX8850-SW-1121CD=
MGX 8850 Syst Software License-PXM Spare (Version 1.1.21) MGX8850SW-1121
MGX 8850 Syst Software License - Release (Version 1.1.23) MGX8850-SW-1123
MGX 8850 Syst Software License - Spare CD (Version 1.1.23) MGX8850-SW-1123CD=
MGX 8850 Syst Software License-PXM Spare (Version 1.1.23) MGX8850SW-1123
MGX 8850 Syst Software License- Release (Version 2.0.00) MGX8850-SW-2000
MGX 8850 Syst Software License- Spare CD (Version 2.0.00) MGX8850-SW-2000CD=
MGX 8850 Syst Software License- PXM Spare (Version 2.0.00) MGX8850SW-2000