The Cisco FastHub 300 series of 100BaseT hubs combines all the benefits of stackable hubs with unmatched configuration flexibility, affordability and integrated Cisco IOS technologies. These modular, Class II repeaters deliver 10 times the performance of 10BaseT hubs and provide a choice of modules for a combination of cost-effective 10BaseT and 100BaseT bridging, integrated management and port expansion for a highly scalable, manageable and resilient solution. The FastHub 300 series hubs are ideal high-performance alternatives to 10BaseT hubs, delivering affordable 100-Mbps performance to workgroups and server farms. The FastHub 316T comes equipped with 16 100BaseTX ports for connecting your workstations and servers with inexpensive UTP wiring. The FastHub 316C has 15 100BaseTX ports and one100BaseFX port for linking UTP devices to a fiber Fast Ethernet backbone. Both hubs expand easily to 32 ports within a single unit by simply installing a 100BaseTX/16 port module in an expansion slot. The module is hot-swappable, so you can add users without powering down the network and disrupting existing users. Up to four fully configured FastHub 300 series hubs can be interconnected using a hub expansion cable to create a single, 128-port logical repeater. For the ultimate in expandability, the hub`s unique Class II design lets you connect two of these 128-port stacks directly together in a single collision domain. The design also lets you distribute and connect hubs and hub stacks in separate wiring closets without requiring an intermediate switch, bridge or router. EOL: Cisco FastHub 300 Series Hubs
Product Overview
Key Features and Benefits
Specifications
Hardware
|
Description |
Specification |
|---|---|
|
Configuration guidelines |
1043 ft (318 m) maximum cable distance between any two end stations with one FastHub 300 series hub in the path using a combination of UTP and fiber cabling 731 ft (223 m) maximum cable distance between any two end stations with two FastHub 300 series hubs in the path using UTP wiring only 774 ft (236 m) maximum cable distance between any two end stations with two FastHub 300 series hubs in the path using a combination of UTP and fiber cabling 702 ft (214 m) maximum cable distance between any two end stations with one FastHub 300 series hub and one third-party 100BaseT Class II hub in the path using UTP wiring only 741 ft (226 m) maximum cable distance between any two end stations with one FastHub 300 series hub and one third-party 100BaseT Class II hub in the path using a combination of UTP and fiber cabling 328 ft (100 m) maximum cable distance between a 100BaseTX port and an end node using UTP wiring only |
|
Indicators |
Per-port LEDs indicate Link Integrity, Receive Activity, and Enabled/Disabled status Per-hub activity meter and Collision LEDs gauge network load Hub ID and hub status LEDs Redundant power system status |
|
Cabling requirements |
100BaseTX ports: Integrated 100BaseTX media interface for use with two-pair Category 5 UTP cabling Standard RJ-45 connectors 100BaseFX port: Integrated 100BaseFX media interface for use with 62.5/125- or 50/125-micron multimode optical fiber Standard SC connector |
|
Network management support |
SNMP MIB II, SNMP MIB extensions, Ethernet Interface MIB, Repeater MIB, and RS-232 MIB Manageable under CiscoWorks and other SNMP management systems IP address assignment via Dynamic Host Control Protocol (DHCP) or Bootstrap Protocol (BOOTP) Cisco device discovery support using the Cisco Discovery Protocol (CDP) and the CDP MIB RMON MIB (EtherHistory, EtherStats, Alerts, and Events) VT100-based Telnet console and out-of-band management console |
|
Dimensions (H x W x D) |
3.43 x 17.75 x 12.00 in. (8.7 x 45.1 x 30.5 cm) |
|
Weight |
15 lb (6.8 kg) |
|
Agency approvals |
UL 1950 CE CSA 950 EN 60950 IEC 950 |
|
Electromagnetic emissions certifications |
VCCI II EN 55022B CE Marking FCC Class B |
|
Description |
Specification |
|---|---|
|
Power consumption |
80Watts |
|
Input voltage |
90 to 250Volts, 50 to 60 Hz |
|
Operating temperature |
23° to 113°F (-5 to 45°C) |
|
Storage temperature |
-13° to 158°F (-25° to 70°C) |
|
Operating humidity |
10 to 85% noncondensing |
|
Operating altitude |
up to 9843 ft (3000 m) |
|
Configuration Guidelines |
|
|---|---|
|
Maximum cable distance between the BMM and an attached device: |
|
|
10BaseT port |
Half-duplex capability enabled: 328 ft (100 m) using UTP wiring Full-duplex capability enabled: 328 ft (100 m) using UTP wiring |
|
100BaseTX port |
Half-duplex capability enabled: 328 ft (100 m) using UTP wiring Full-duplex capability enabled: 328 ft (100 m) using UTP wiring |
|
100BaseFX port |
Half-duplex capability enabled: 1,352 ft (412 m) using fiber optic cabling Full-duplex capability enabled: 6,562 ft (2 km) using fiber optic cabling |
|
Indicators |
|
|
Per-port LEDs indicate Link Integrity, Receive Activity, and Enabled/Disabled status |
|
|
Module status LEDs indicates module operating status |
|
|
Cabling Requirements |
|
|
10BaseT port |
Integrated 10BaseT media interface for use with two-pair Category 3, 4, or 5 UTP cabling Standard RJ-45 connector |
|
100BaseTX port |
Integrated 100BaseTX media interface for use with two-pair Category 5 UTP cabling Standard RJ-45 connector |
|
100BaseFX port: |
Integrated 100BaseFX media interface for use with 62.5 125- or 50/125-micron multimode optical fiber Standard SC connector |
The FastHub 300 series supports the following applications:
Connecting Legacy 10BaseT Hubs to 100BaseT Environments: A FastHub 300 series repeater can be used to create a high-performance network while preserving investment in 10BaseT equipment. A FastHub 300 base unit configured with an expansion module will support a total of 32 100BaseT users or servers. The BMM`s 10BaseT and 100BaseT bridging functionality provides connectivity to a legacy 10BaseT hub and a direct connection from the hub to a 100BaseT-enabled switch or router.
Interconnecting FastHub 300 Series Hubs Over Extended Distances: A network can be designed using FastHub 300 series repeaters to deliver 100-Mbps throughput for high-performance data transfers for workgroups and server farms over an extended distance. Two BMM-enabled FastHub repeaters (or FastHub stacks) can be used to interconnect 100BaseT workgroups and server farms when wiring closets are further apart than the allowable distance defined by the Class II repeater design guideline.
Connecting FastHub 300 Series Hubs to the Backbone Over Extended Distances: FastHub 300 series hubs or stacks can connect workgroups and server farms to a campus backbone at a distance of up to 2 kilometers. FastHub 300 series hubs or stacks each with a BMM-100BaseFX can be located up to 2 kilometers from the corporate backbone cabling.
| Part Description | Part Number |
|---|---|
| FastHub 316T (16-port 100BaseTX base unit) | WS-C316T |
| FastHub 316C (16-port 100BaseFX base unit) | WS-C316C |
| 100BaseTX/16 (16-port 100BaseTX repeater module) | WS-X3116 |
| BMM-100BaseTX (Bridge Management Module 100BaseTX) | WS-C316-BMM-T |
| BMM-100BaseFX (Bridge Management Module 100BaseFX) | WS-C316-BMM-C |
| NMM (Network Management Module) | WS-C316-NMM |
| Expansion cable (Hub stacking cable) | WS-C316-CAB-EXP |