The FastHub 200 series hubs deliver the lowest-cost, managed 100BaseT hub solution for smaller workgroups and server farms. These Class II standalone hubs combine 100-Mbps performance and integrated management with Cisco IOS technologies. The FastHub 200 series hubs are ideal high-performance alternatives to 10BaseT hubs. The first model in the FastHub 200 series, the FastHub 216T, has 16 100BaseTX ports for high-speed connectivity over UTP wiring. The hub`s unique Class II design lets you connect two hubs together, creating a 30-port collision domain. The FastHub 216T can connect to other Class II hubs including the FastHub 300 and FastHub 100 series. The Class II design also lets you distribute and connect hubs in separate wiring closets, without requiring an intermediate switch, bridge or router.
Figure 27-12: FastHub 216T 100BaseTX Hub Rear View
Figure 27-13: FastHub 200 Series Unit in a Rack
EOL: Cisco FastHub 200 Series Hubs
Product Overview
Key Features and Benefits
Specifications
Hardware
|
Description |
Specification |
|---|---|
|
Compatibility |
Compatible with the IEEE 802.3u standard for interoperability with other 100BaseT products IEEE 802.3u Class II repeater-compliant |
|
Performance |
100-Mbps peak and aggregate throughput |
|
Placement |
19-in. rack-mount hardware included |
|
Configuration guidelines |
Maximum cable distance between any two end stations with one FastHub 200 series hub in the path: 656 ft (200 m) Maximum cable distance between any two end stations with two hubs in the path: 731 ft (223 m) with two FastHub 200 series hubs 702 ft (214 m) with one FastHub 200 series hub and one third-party 100BaseT Class II repeater Maximum cable distance between 100BaseTX port and an end node: 328 ft (100 m) |
|
Cabling requirements |
100BaseTX ports: Integrated 100BaseTX media interface for use with two-pair Category 5 UTP cabling and standard RJ-45 connectors Uplink port on a FastHub 216T: Straight-through cable to connect to a non-uplink port on a second hub Non-uplink port on a FastHub 216T: Crossover cables to connect to a non-uplink port on a second hub Direct 100BaseT connection between two hubs: Maximum of one |
|
Management |
Built-in for monitoring on a per-port and per-hub basis Supports SNMP, Telnet, terminal-based out-of-band management, and RMON for comprehensive management and simplified troubleshooting Can be managed by CiscoWorks Windows and other SNMP-compatible management systems on a per-port and per-unit basis |
|
Indicators |
Per-port LEDs for link integrity, receive activity, and enabled/disabled status Hub utilization meter and group collision LED for gauging network load System LED for AC operation status Redundant power system status LED |
|
Redundancy |
Supports connection to the optional Cisco redundant power system (RPS) |
|
Dimensions (H x W x D) |
1.73 x 17.50 x 8.25 in. (4.4 x 44.5 x 20.1 cm) |
|
Weight |
11 lb (5 kg) |
|
Agency approvals |
AS/NZS 3260, TS001, UL 1950/CSA 22.2 No. 950, IEC 950/EN 60950, NOM 019, CE |
|
Electromagnetic emissions certifications |
FCC Part 15 Class B, EN 55022B Class B (CISPR22 Class B), VCCI Class II, AS/NRZ 3548 Class B, CE |
|
Description |
Specification |
|---|---|
|
Power consumption |
40W |
|
Input voltage |
90 to 127/200 to 240 VAC autoranging 50 to 60 Hz |
|
Operating temperature |
23 to 113° F (-5 to 45° C) |
|
Operating relative humidity |
10 to 85% noncondensing |
|
Operating altitude |
Up to 9842 ft (3,000 m) |
For additional information, access Cisco Connection Online at http://www.Cisco.com
The FastHub 200 series support the following applications:
100-Mbps workgroups
FastHub 200 series hubs can be used to create a 100-Mbps managed workgroup of up to 30 users. The hubs can connect to any Catalyst switch or Cisco router that has a Fast Ethernet connection using UTP cabling.
Server farms
With FastHub 200 series hubs, network managers can affordably build high-performance server farms attached to 100BaseT-enabled Cisco routers or Catalyst switches.
| Part Description | Part Number |
|---|---|
| FastHub 216T (100BaseTX hub) | WS-C216T |
| 600W redundant power system, AC-input with DC power cables | PWR600-AC-RPS-CAB |
| 600W redundant power system, AC-input without DC power cables | PWR600-AC-RPS-NCAB |
| FastHub 200 series SMARTnet maintenance | See the "Service and Support" chapter. |