Cisco`s AccessPath-LS3 access solution is designed to meet the demands of rapidly growing Internet Service Providers (ISPs), telecommunications carriers, and other network service providers who offer managed distributed Internet connections. AccessPath-LS3 also provides a ready solution for large enterprises as they expand their intranet requirements to include a significant component of dial access. As a member in a family of integrated solutions, the AccessPath-LS3 provides an immediate high performance solution for small to medium dial points of presence (POPs) in a single, complete solution. Built upon Cisco`s Dial Access Stacking Architecture (DASA), the AP-LS3 leverages the high-density AS5300 dial platform, the high speed FastHub 200 fast ethernet hub, and Cisco`s industry-leading 3640 router product, to ensure cost-effective scalability from 96- to 384-port capacity in North America and 120 to 480 port capacity in Europe and rest of the world. This architecture accommodates rapid growth in network demand as well as geographic reach. It offers breakthroughs in distributed and remote POP management, density, and scalability, while continuing to provide the rich set of access services that are part of Cisco IOS software. To complement its industry-leading networking equipment, Cisco has developed a full spectrum of support solutions. The Cisco lifecycle-focused portfolio features startup, maintenance, marketing, advanced and custom services to maximize and protect your investment. The following table lists the features and benefits available with the Cisco AccessPath-LS3. Cisco AccessPath-LS3 Large Enterprise Access System
Product Overview
Key Features and Benefits
|
Features |
Benefits |
|---|---|
|
Carrier Class Remote Access Solution |
Scalability: 96 to 384 (T1)/120 to 480 (E1) hybrid asynchronous/ISDN dial ports High availability, hot swap |
|
Complete solution |
Reduced time to deploy Simplifies set-up Reduced operational costs Eliminates ordering complexity |
|
Global, lifecycle-focused support solutions |
Improved network reliability Increased network efficiency Flexibility to scale network as demand grows Access to technical leadership |
|
Full Cisco IOS support |
Differentiated dial services Provides the widest array of networking and routing protocol support in the industry for large scale deployment |
|
Cisco AccessPath Monitoring Software |
Monitors the AccessPath-LS3 as one complete system Easy accessibility via web based interface Centralized system level dial monitoring, reducing operation costs Carrier class data collection |
|
Modular and scalable DASA architecture |
Protects initial investment while maintaining growth potential Improves network (and service) availability, reducing time and money lost due to network outages Facilitates effective management of large dial pools, thus supporting higher level of service with less equipment |
|
Modem management |
Reduced problem detection time |
|
WAN optimization, including compression, routing filters, snapshot routing, and dial-on-demand routing |
Helps customers to reduce WAN costs, the single largest cost of internetwork operation |
|
Security management, including TACACS+, RADIUS, access lists, and violation logging |
Provides comprehensive security throughout customer`s core network infrastructure |
|
Flexible, dual-bank Flash architecture |
Enabling rapid switch-in of known good images. Reduces software upgrade time and allows the storage of multiple software images in the same chassis |
|
Integrated CSUs, router, and modems accommodate ISDN Primary Rate Interface (PRI) T1/E1 lines or channelized T1 lines |
Terminates asynchronous modem and digital ISDN calls with one phone number and allows a simple, cost-efficient migration path from today`s analog dialup environment to the fast-growing ISDN digital services |
|
Description |
Specification | |
|---|---|---|
|
Processor Type |
Dial access server shelf |
150 MHz R4700 (per four T1/E1/PRI) |
|
Router shelf |
100 MHz IDT R4700 RISC | |
|
Main Memory |
Dial access server shelf |
16 MB main DRAM, and 16 MB packet DRAM |
|
Router shelf |
1 MB processor SRAM, with 16 MB DRAM | |
|
Flash Memory |
Dial access server shelf |
8 MB |
|
Router shelf |
4 MB Flash Memory | |
|
Trunk Interfaces: |
Up to 16 T1/E1/PRI for dial clients Also supports CT1 | |
|
Modems/ISDN session (any call can be either async or ISDN) |
E1 system: 120-480 | |
|
T1 system: 96-384 | ||
|
Backhaul Interfaces |
Fast Ethernet, HSSI, V.35 serial, 10BaseT | |
|
AS5300 Processing Power/Bandwidth |
5804.5 MIPS aggregation per shelf 16 Mbps bandwidth TDM bus 300 Mbps bandwidth D-Bus | |
|
AP-LS3 Max Processing Power/Bandwidth |
23218 MIPS aggregate per system 32 MB aggregate ingress 100 MB interconnect |
|
Description |
Specification | |
|---|---|---|
|
Input Watts (MAX) |
Dial access server shelf |
420W (per shelf) |
|
Router shelf |
140W (per shelf) | |
|
Ethernet hub shelf |
25W | |
|
AC Input Voltage |
100- 240 VAC | |
|
Frequency |
50- 60 Hz | |
|
AC Input Current |
Dial access server shelf |
6.0A @ 110 VAC |
|
Router shelf |
2.0A @ 110 VAC | |
|
Ethernet hub shelf |
0.5A @ 110 VAC | |
|
DC Input Voltage |
-14 VDC nominal | |
|
DC Input Current |
Dial access server shelf |
6.0A max @-14 VDC |
|
Router shelf |
5.0A max @-14VDC | |
|
Ethernet hub shelf |
1.0A max @-14VDC | |
|
Operating temperature |
32 to 104°F (0 to 40°C) | |
|
Storage temperature |
-4 to 149°F (-20 to 65°C) | |
|
Operating relative humidity |
10 to 85%, noncondensing | |
|
Nonoperating relative humidity |
5 to 95%, noncondensing |
|
Description |
Specification |
|---|---|
|
Dimensions for full stack (H x W x D) |
49.75 x 23.09 x 30.00 in. (104 x 58.6 x 91.4 cm) |
|
Weight (average shipping weight) |
Minimum per stack (approx) 15 lbs. (6.75 kg) |
|
Maximum per stack (approx) 30 lbs. (13.5 kg) | |
|
Operating temperature |
32 to 104°F (0 to 40°C) |
|
Storage temperature |
-4 to 149°F (-20 to 65°C) |
|
Operating relative humidity |
10 to 85%, noncondensing |
|
Nonoperating relative humidity |
5 to 95%, noncondensing |
For software specification information, access Cisco Connection Online at http://www.cisco.com
| Part Description | Part Number |
|---|---|
| Dial Shelf | (choose one to four of the same type of dial shelf) |
| AccessPath 5301 chassis, memory | AP5301S |
| Power Configuration | (required) |
| AC Power Option, AP5301 | AP53-AC-PWR |
| Ingress | (required, choose one) |
| Quad T1/PRI Card | AP53-4CT1 |
| Quad E1/PRI Card | AP53-4CE1 |
| Modem Options | (optional) |
| 96 Modem Card | AP53-96M |
| 108 Modem Card | AP53-108M |
| 120 Modem Card | AP53-120M |
| IOS Software Options | (required, choose one) |
| IP Plus IOS | SF53CP-11.2.9X |
| Enterprise Plus IOS | SF53AP-11.2.9X |
| Switching Interconnect | (required) |
| 100 MB Ethernet Hub, 16 ports, SNMP manageable | AP200S |
| Router Shelf | (required) |
| Cisco 3640 router, AC power, memory, 2E2W, WIC-1T, FE | AP3640LS |
| IOS Software Options | (required, choose one) |
| IP Plus IOS | SF364CP-11.2.9P |
| Enterprise Plus IOS | SF364AP-11.2.9P |
| Backhaul/WIC Interfaces | (choose maximum of 1 backhaul, 1 WIC card) |
| 1 Fast Ethernet 100BaseTx port adapter | NM-1FE-TX |
| 4 port serial network module | NM-4T |
| 1 port serial WAN interface card | WIC-1T |
| 1 port, 4 wire, 56kbps DSU/CSU WAN interface card | WIC-1DSU-56K4 |
| System Controller Upgrade | (highly recommended) |
| 16 port async module plus octopus cables for AP3640LS | NM-16A |
| Power Cables (AC Only) | (choose one cable per 5301, 3640, 216T ordered) |
| Shielded Power Cables, United States | CAB-LS3-AC |
| Shielded Power Cables, Australia | CAB-LS3-ACA |
| Shielded Power Cables, Europe Italy | CAB-LS3-AI |
| Shielded Power Cables, Europe United Kingdom | CAB-LS3-ACU |
| Shielded Power Cables, Europe | CAB-LS3-ACE |
| Technology License | (optional, one license per AP53xx) |
| 96 Modem Management Technology License | FRAP-MMTL-96 |
| 108 Modem Management Technology License | FRAP-MMTL-108 |
| 120 Modem Management Technology License | FRAP-MMTL-120 |
| Network Management | (highly recommended) |
| AccessPath Network Management Software | AP-NM-001 |
| Configuration Kit | (required) |
| Five 7ft Ethernet cables, CD-ROM, Wiring Diagram | LS3-CABLE-DOC |
There no special support or service requirements for the AccessPath-LS3 series. You can obtain technical support from the Technical Assistance Center (TAC), and SmartNet contracts are available.