cc/td/doc
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Cisco 6130 — DSL Access Concentrator

Cisco 6130 — DSL Access Concentrator

Product Overview

The Cisco 6130 digital subscriber line (DSL) access concentrator is a key member of the industry-leading Cisco carrier-class DSL family of products. Designed for large-scale deployment of high-performance, multi-service, and profit-centered DSL services, the Cisco 6130 is intended for North American incumbent local exchange carrier (ILEC) and competitive local exchange carrier (CLEC) networks. The Cisco 6130 has a growing suite of asymmetric and symmetric DSL line technologies. These line technologies-combined with the high-powered ATM switching fabric, edge switch-class traffic management features, and scalable network-management capabilities of this family-enable service providers to move beyond simple, unprofitable, nonextensible data-transmission connections to Internet service providers (ISPs) into profit-generating, New World service offerings.

Key Features and Benefits

Specifications

Hardware
Table 5-8: Technical Specifications for Cisco 6130

Description

Specification

NI-1 Common Cards

Interfaces

OC-3 SM, OC-3 MM, and DS3 NI-1 option

NI-1 supports ATM switch fabric and features as well as network interface facility

ATM Features

UBR

PVCs

ILM

IISP

System Controller

Provides all system operation control, software updates, and management system interaction

Management System

ViewRunner for HP OpenView

Cisco DSL Manager

Subtending (optional)

Dual-port DS3

NI-2 Common Cards

Interfaces

1 STM-1/OC-3 WAN interface, 1 STM-1/OC-3 subtend interface

  • Dual SC fiber

  • Single-mode intermediate reach and multimode

1 DS-3 WAN interface, 2 DS-3 subtend interfaces

ATM Features

UNI 3.1/4.

UBR, ABR, VBR-nrt, CBR

PVCs, SPVCs, and SVCs

512,000 VCs, 256 VPs (32 shaped)

ILMI

IISP/PNNI

Egress traffic shaping

Traffic policing (usage parameter control) per ITU-TI.371 and ATM Forum UNI specification

Management System

Cisco DSL Manager (CDM)

Other

MIPS processor running Cisco IOS 12.0(5) DA and SNMP V.2

Management interfaces:

  • In band: ATM VC

  • Out of band: 10BaseT Ethernet

RS-232 Console (RJ-48)

RS-232 Auxiliary (RJ-48)

External timing interface (BITS)

DSL Interface Options

Dual- and quad- port ADSL

  • ANSI T1.413 Issue 2 (ADSL over POTS)

  • ITU G.992.1 (G.dmt)

  • ITU G.992.2 (G.lite)

  • ITU G.994.1 (G.hs)

Quad-port SDSL (2B1Q)

Data Rate

SDSL (2B1Q)

Speed range: 144 kbps to 1168 kbps symmetric

Increments: 1168, 1040, 784, 528, 400, 272, and 144 kbps

ANSI T1.413 Issue 2 ADSL

Downstream speed range: 32 to 8032 kbps

Upstream speed range: 32 to 864 kbps

Increments: 32 kbps

ITU G.992.1 (G.dmt) ADSL

Downstream speed range: 32 to 8032 kbps

Upstream speed range: 32 to 864 kbps

Increments: 32 kbps

ITU G.992.2 (G.lite) ADSL

Downstream speed range: 32 kbps to 1536 kbps

Upstream speed range: 32 kbps to 512 kbps

Increments: 32 kbps

Management Access

DB-9 serial interface for craft alarm discovery

RJ-45 Ethernet

ATM in-band management

External Alarm Contacts

Critical, major, and minor wire wrap alarm contacts for visual, audible, and E2A fan tray alarm


Table 5-9: Power Requirements for Cisco 6130

Description

Specification

Power Input

Dual A+B feeds

-48VDC, 20A fused recommended for quad-port ADSL, 10A for dual-port ADSL, 10A for quad-port SDSL

Cooling

Convection and forced-air cooling options


Table 5-10: Physical and Environmental Specifications for Cisco 6130

Description

Specification

Multiplexer Chassis

Dimensions (H x W x D)

15.75 x 23 x 12 in. (40.0 x 58.4 x 30.5 cm)

Weight

30.65 lb (empty chassis), 60.85 lb (fully configured)

POTS Splitter Chassis

Dimensions (H x W x D)

7 x 23 x 12 in. (17.8 x 58.4 x 30.5 cm)

Weight

15.55 lb (empty chassis), 33.8 lb (fully configured)

Operating Temperature

41 to 104°F (5 to 40°C) operating

23 to 122°F (-5 to 50°C) short-term operating

Altitude

-60 to 3200 m

Relative Humidity

5% to 90% (noncondensing)


Table 5-11: Regulatory Approvals for Cisco 6130

Description

Specification

Certifications

UL 1950

UL 1459

FCC Part 15

Bellcore GR-1089-CORE

Bellcore GR-63-CORE (NEBs Level 3)


Software

For more information on software, see the Products and Part Number table in the following section.

Ordering Information

Product and Part Numbers Table 5-12: Part Numbers for the Cisco 6130
Part DescriptionPart Number
Cisco 6100 Series Advanced DSL Access Multiplexer
ADSL Multiplexor Chassis CISCO6100
ADSL Multiplexor Chassis (Spare) CISCO6100=
ADSL Line Interface Module Chassis CISCO6110
ADSL Line Interface Module Chassis (Spare) CISCO6110=
ADSL CO POTS Splitter Chassis CISCO6120
ADSL CO POTS Splitter Chassis (Spare) CISCO6120=
Advanced ADSL Multiplexor Chassis CISCO6130
Mux 6130 Chassis Spare CISCO6130=
Cisco 6100 Series System Controller Cards
6100 Series System Controller Card SC-6100-2
6100 Series System Controller Card SC-6100-2=
Cisco 6100 ATM Switching Options
Cisco6100 DS3 NIM 6100NIM-1-DS3-2
Cisco6100 DS3 NIM 6100NIM-1-DS3-2=
Cisco6100 OC3 Multi Mode Fiber NIM 6100NIM-1-OC3-MM2
Cisco6100 OC3 Multi Mode Fiber NIM 6100NIM-1-OC3-MM2=
Cisco6100 OC3 Single Mode Fiber NIM 6100NIM-1-OC3-SM2
Cisco6100 OC3 Single Mode Fiber NIM 6100NIM-1-OC3-SM2=
2xDS3 Subtend NEBS upgrade 6100-ST-3-DS3
6100 Subtending I/O for NEBS upgrade 6100-ST-IO-3-DS3
6100/6130 NI2 I/O CARD 6100/30-NI2-I/O-1
6100/6130 NI2 I/O CARD 6100/30-NI2-I/O-1=
NI2, 1 OC3/STM1 Multimode; 1 WAN, 1 Subtend NI-2-155MM-155MM
NI2,1 OC3/STM1 Multimode;1 WAN,1 Subtend - Spare NI-2-155MM-155MM=
NI2, 1 OC3/STM1 Single Mode; 1 WAN, 1 Subtend NI-2-155SM-155SM
NI2,1 OC3/STM1 Single Mode;1 WAN,1 Subtend - Spare NI-2-155SM-155SM=
NI2,1 DS3 WAN, 2 DS3 Subtend NI-2-DS3-DS3
NI2, 1 DS3 WAN, 2 DS3 Subtend - Spare NI-2-DS3-DS3=
Cisco 6100 Series Modem Options
6100 Dual CAP ATU-C - Direct Connect ATUC-2-CAP-DIR-2
6100 Dual CAP ATU-C - Direct Connect ATUC-2-CAP-DIR-2=
6100 Dual CAP ATU-C - Digital Off Hook ATUC-2-CAP-DOH-2
6100 Dual CAP ATU-C - Digital Off Hook ATUC-2-CAP-DOH-2=
6100 Dual DMT Issue 2 - Direct Connect ATUC-2-DMT2-DIR-1
6100 Dual DMT Issue2 - Direct Connect ATUC-2-DMT2-DIR-1=
4 port DMT Issue 2 Line Card ATUC-1-4DMT
4 port DMT Issue 2 Line Card - Spare ATUC-1-4DMT=
Cisco 6100 Series Rear Door Options
Rear Door 6100-RD-01
Rear Door 6100-RD-01=
Cisco 6100 Series Spares and Accessories
Fan Module: (1) Fan Tray, (3) Fan Units, (1) Fan Filter 6100-FM-01
Fan Module: (1) Fan Tray, (3) Fan Units, (1) Fan Filter 6100-FM-01=
Fan Unit 6100-FU-01=
Fan Tray 6100-FT-01=
Fan Tray Air Filters, Qty (5) 6100-AF-01=
NEBS Update Kit 6100-NU-01=
6130 System I/O module 6100-SYS-IO-3
6130 System I/O module for NEBS subtending and upgrade 6100-SYS-IO-3=
6100/6130 NI2 I/O CARD 6100/30-NI2-I/O-1
6100/6130 NI2 I/O CARD 6100/30-NI2-I/O-1=
Thermal Upgrade Kit for Cisco6100 6100-THERMAL-UPGD=
6100/6130 FAN UPGRADE KIT 6100-FAN-UPGD-1=
6130 NI-2 Fan Cable CAB-6130-NI2-FAN=
Cisco 6100 Series Software Options
6100 Software Release 2.2.0 SF-6100-2.2.0
6100 Software Release 2.3.3 SF-6100-2.3.3
6100 Software Release 3.0 SF-6100-3.0
6100 Software Release 2.4.1 SF-6100-2.4.1
Cisco 6100 Series IOS CISCO 6130 DSL ACCESS CONCENTRATOR IOS S61Z-12.0.8DA
Cisco 6100 Series Software Spares
Cisco 6100 Series IOS CISCO 6130 DSL ACCESS CONCENTRATOR IOS S61Z-12.0.8DA=
Cisco 6100 Series Feature Spare
CISCO IOS 6100/6130 Series DSL Concentrator - ATM QOS FL61-02=
CISCO IOS 6100/6130 Series DSL Concentrator - Subtending FL61-03=
CISCO IOS 6100/6130 Series DSL Concentrator - Signaling FL61-04=
CISCO IOS 6100/6130 Series DSL Concentrator- O2 to O4 Bundle FL61-05=
Cisco 6100 Series Line Interface Options
6100 Series Quad Line Interface Module SLC-1-4LIM-CAP
Quad LIM Card SLC-1-4LIM-CAP=
6100 Quad 2B1Q STU-C - Direct Connect STUC-4-2B1Q-DIR-1
6100 Quad 2B1Q STU-C - Direct Connect STUC-4-2B1Q-DIR-1=
Cisco 6100 Cables
6110 to 6100 Cable Kit CAB-61-011
6110 to 6100 Cable Kit CAB-61-011=
6120 to 6100 Cable Kit CAB-61-014
6120 to 6100 Cable Kit CAB-61-014=
Cisco 6110 Controller Cards
6110 LIM Controller LC-6110-2
6110 LIM Controller LC-6110-2=
Cisco 6110 Cables
6110 to 6110 Cable Kit CAB-61-012
6110 to 6110 Cable Kit CAB-61-012=
Cisco 6120 Modules
6120 Quad POTS Splitter Card, 8 kHz PSC-6120-1=
Spare for Quad Port DMT Issue2 POTS Splitter Module PSM-4-DMT2-1=
Cisco 6120 Cables
6120 to 6110 Cable Kit CAB-61-013
6120 to 6110 Cable Kit CAB-61-013=
6120 to MDF Cable, 50 CAB-61-015
6120 to MDF Cable, 50 CAB-61-015=
6120 to MDF Cable, 150 CAB-61-016
6120 to MDF Cable, 150 CAB-61-016=
6120 to MDF Cable, 75 CAB-61-017
6120 to MDF Cable, 75 CAB-61-017=
6120 to MDF Cable, 175 CAB-61-018
6120 to MDF Cable, 175 CAB-61-018=
Cisco 6130 Cables
MC 128 Port to PSC 80 Port Cable Kit CAB-MC128-PS80
MC 128 Port to PSC 80 Port Cable Kit CAB-MC128-PS80=
128 Port Mux Chassis to 128 Port PSC Cable CAB-6121-1
MC to MDF Repin 2x 3:2 Champ Cable Kit CAB-MC-3:2-REPIN
MC to MDF Repin 2x 3:2 Champ Cable Kit CAB-MC-3:2-REPIN=
128 Port Mux Chassis to MDF Cable Kit CAB-MC128-MDF
128 Port Mux Chassis to MDF Cable Kit CAB-MC128-MDF=
MC 64 Port Service Mix Cable Kit CAB-64-MIX
MC 64 Port Service Mix Cable Kit CAB-64-MIX=
MC 128 Port Service Mix Cable Kit CAB-128-MIX
MC 128 Port Service Mix Cable Kit CAB-128-MIX=
79 Port PSC to MDF Re-Pin Cables, 2 Cable Set, 2:2 Champ CAB-PSC-80-REPIN
79 Port PSC to MDF Re-Pin Cables, 2 Cable Set, 2:2 Champ CAB-PSC-80-REPIN=
6120 to 6100 Cable Kit CAB-61-014
6130 NI-2 Fan Cable CAB-6130-NI2-FAN=

Configuration Worksheets

Example Configurations

To order and configure a Cisco DSL Access Concentrator, follow these steps (see table below):

1. Select a Cisco 6130 chassis for new installations or existing customers deploying Cisco 6130

2. Select configuration style (Direct with POTS, Direct no POTS), and determine if a POTS splitter is required for that configuration style. Direct with POTS implies basic telephone service. Direct no POTS implies basic telephone service is not required.

3. Select network interface (NI) type, (i.e. single-mode optical, multimode optical, or DS3 coax).

4. Determine whether or not you will use subtending.

5. Select xDSL line card type(s).

6. Add one fan tray per Cisco 6130 chassis if SDSL or ADSL DMT cards are to be used.

7. If deploying a Cisco 6130 with an NI-1 card, add a system controller.

8. Select cables. For future releases Cisco is providing cabling to accommodate higher-density SDSL and ADSL line cards. These cables are recommended for customers planning to wire the Cisco DSL Access Concentrators for expansion from dual- to quad-port configurations.

9. Add miscellaneous parts such as blank cards and a rear door for the shelf.

Table 5-13: Cisco 6130 Configuration Steps

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Chassis Selection

Configuration Style

Network Interface

Subtending (Optional)

xDSL Cards

Fan Tray Selection

Cisco 6130

Direct with POTS

Select optical (OC3) or electrical (DS3)

If required, select subtending card and cables

2xDMT

Needed with 2xDMT

Cisco 6130

Direct no POTS splitter

Select optical (OC3) or electrical (DS3)

If required, select subtending card and cables

2xDMT

4xSDSL

Needed with 2xDMT, or 4xSDSL


hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Sep 27 05:13:04 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.