The Cisco 6130 digital subscriber line (DSL) access concentrator is a key member of the industry-leading Cisco carrier-class DSL family of products. Designed for large-scale deployment of high-performance, multi-service, and profit-centered DSL services, the Cisco 6130 is intended for North American incumbent local exchange carrier (ILEC) and competitive local exchange carrier (CLEC) networks. The Cisco 6130 has a growing suite of asymmetric and symmetric DSL line technologies. These line technologies-combined with the high-powered ATM switching fabric, edge switch-class traffic management features, and scalable network-management capabilities of this family-enable service providers to move beyond simple, unprofitable, nonextensible data-transmission connections to Internet service providers (ISPs) into profit-generating, New World service offerings. Multiservice DSL DSL line cards currently include standards-compliant ANSI T1.413 Issue 2 asymmetric DSL (ADSL), as well as symmetric DSL (SDSL) cards. Full ADSL data rates are supported (8.024 Mbps downstream/864 Mbps upstream for discrete multitone (DMT) and 1536-Mbps downstream/512-Mbps upstream for G.lite). ADSL subscriber train rates can automatically rate adapt to the highest attainable line speed based on individual loop characteristics, or they can be selectively provisioned based on a desired service definition. For SDSL, data rates up to 1.168 Mbps are supported. Scalable architecture The Cisco 6130 is standard equipped with a proven ATM switching fabric and traffic-management feature set required for high-volume Internet access provisioning. The Cisco 6130 architecture supports a variety of ATM service qualities with scalability to support up to 1664 ports per fully subtended system. Each subscriber access port and network trunk port can have dedicated traffic buffers for ensuring reliable and fair traffic throughput and performance. Scalable, robust, carrier-class network management support The Cisco 6130 is managed by Cisco DSL Manager, a full element-management system that supports up to 350,000 subscribers today, with a path to over one million in the first half of 2000. Advanced features include in-band and out-of-band node access, CORBA application interfaces to higher-layer network management systems (NMS) for flow-through service provisioning, and map-level views of network domains. All of these advanced characteristics combine to create a large-scale network management solution capable of supporting hundreds of thousands, and eventually over one million, subscriber lines. Standards-compliant The Cisco 6130 fully conforms to UL1950, UL 1459, FCC Part 15, Bellcore GR-1089-CORE, and Bellcore GR-63-CORE, as required for central-office or collocation deployment. Compliance to ATM, ANSI, and ITU standards is also provided. Interoperability The Cisco 6130 delivers standards-based, interoperable network and service capabilities including fully interoperable, standards-based ITU G.992.1 (G.dmt) and G.992.2 (G.lite), ANSI T1.413 Issue 2, Point-to-Point Protocol (PPP) over ATM, and integration with the end-to-end Cisco ADSL services architecture. Cisco 6130 DSL Access Concentrator
Product Overview
Key Features and Benefits
Specifications
Hardware
|
Description |
Specification | |
|---|---|---|
|
NI-1 Common Cards |
Interfaces |
OC-3 SM, OC-3 MM, and DS3 NI-1 option NI-1 supports ATM switch fabric and features as well as network interface facility |
|
ATM Features |
UBR PVCs ILM IISP | |
|
System Controller |
Provides all system operation control, software updates, and management system interaction | |
|
Management System |
ViewRunner for HP OpenView Cisco DSL Manager | |
|
Subtending (optional) |
Dual-port DS3 | |
|
NI-2 Common Cards |
Interfaces |
1 STM-1/OC-3 WAN interface, 1 STM-1/OC-3 subtend interface
1 DS-3 WAN interface, 2 DS-3 subtend interfaces |
|
ATM Features |
UNI 3.1/4. UBR, ABR, VBR-nrt, CBR PVCs, SPVCs, and SVCs 512,000 VCs, 256 VPs (32 shaped) ILMI IISP/PNNI Egress traffic shaping Traffic policing (usage parameter control) per ITU-TI.371 and ATM Forum UNI specification | |
|
Management System |
Cisco DSL Manager (CDM) | |
|
Other |
MIPS processor running Cisco IOS 12.0(5) DA and SNMP V.2 Management interfaces:
RS-232 Console (RJ-48) RS-232 Auxiliary (RJ-48) External timing interface (BITS) | |
|
DSL Interface Options |
Dual- and quad- port ADSL
Quad-port SDSL (2B1Q) | |
|
Data Rate |
SDSL (2B1Q) |
Speed range: 144 kbps to 1168 kbps symmetric Increments: 1168, 1040, 784, 528, 400, 272, and 144 kbps |
|
ANSI T1.413 Issue 2 ADSL |
Downstream speed range: 32 to 8032 kbps Upstream speed range: 32 to 864 kbps Increments: 32 kbps | |
|
ITU G.992.1 (G.dmt) ADSL |
Downstream speed range: 32 to 8032 kbps Upstream speed range: 32 to 864 kbps Increments: 32 kbps | |
|
ITU G.992.2 (G.lite) ADSL |
Downstream speed range: 32 kbps to 1536 kbps Upstream speed range: 32 kbps to 512 kbps Increments: 32 kbps | |
|
Management Access |
DB-9 serial interface for craft alarm discovery RJ-45 Ethernet ATM in-band management | |
|
External Alarm Contacts |
Critical, major, and minor wire wrap alarm contacts for visual, audible, and E2A fan tray alarm |
|
Description |
Specification |
|---|---|
|
Power Input |
Dual A+B feeds -48VDC, 20A fused recommended for quad-port ADSL, 10A for dual-port ADSL, 10A for quad-port SDSL |
|
Cooling |
Convection and forced-air cooling options |
|
Description |
Specification |
|---|---|
|
Multiplexer Chassis |
|
|
Dimensions (H x W x D) |
15.75 x 23 x 12 in. (40.0 x 58.4 x 30.5 cm) |
|
Weight |
30.65 lb (empty chassis), 60.85 lb (fully configured) |
|
POTS Splitter Chassis |
|
|
Dimensions (H x W x D) |
7 x 23 x 12 in. (17.8 x 58.4 x 30.5 cm) |
|
Weight |
15.55 lb (empty chassis), 33.8 lb (fully configured) |
|
Operating Temperature |
41 to 104°F (5 to 40°C) operating 23 to 122°F (-5 to 50°C) short-term operating |
|
Altitude |
-60 to 3200 m |
|
Relative Humidity |
5% to 90% (noncondensing) |
|
Description |
Specification |
|---|---|
|
Certifications |
UL 1950 UL 1459 FCC Part 15 Bellcore GR-1089-CORE Bellcore GR-63-CORE (NEBs Level 3) |
For more information on software, see the Products and Part Number table in the following section.
| Part Description | Part Number |
|---|---|
| Cisco 6100 Series Advanced DSL Access Multiplexer | |
| ADSL Multiplexor Chassis | CISCO6100 |
| ADSL Multiplexor Chassis (Spare) | CISCO6100= |
| ADSL Line Interface Module Chassis | CISCO6110 |
| ADSL Line Interface Module Chassis (Spare) | CISCO6110= |
| ADSL CO POTS Splitter Chassis | CISCO6120 |
| ADSL CO POTS Splitter Chassis (Spare) | CISCO6120= |
| Advanced ADSL Multiplexor Chassis | CISCO6130 |
| Mux 6130 Chassis Spare | CISCO6130= |
| Cisco 6100 Series System Controller Cards | |
| 6100 Series System Controller Card | SC-6100-2 |
| 6100 Series System Controller Card | SC-6100-2= |
| Cisco 6100 ATM Switching Options | |
| Cisco6100 DS3 NIM | 6100NIM-1-DS3-2 |
| Cisco6100 DS3 NIM | 6100NIM-1-DS3-2= |
| Cisco6100 OC3 Multi Mode Fiber NIM | 6100NIM-1-OC3-MM2 |
| Cisco6100 OC3 Multi Mode Fiber NIM | 6100NIM-1-OC3-MM2= |
| Cisco6100 OC3 Single Mode Fiber NIM | 6100NIM-1-OC3-SM2 |
| Cisco6100 OC3 Single Mode Fiber NIM | 6100NIM-1-OC3-SM2= |
| 2xDS3 Subtend NEBS upgrade | 6100-ST-3-DS3 |
| 6100 Subtending I/O for NEBS upgrade | 6100-ST-IO-3-DS3 |
| 6100/6130 NI2 I/O CARD | 6100/30-NI2-I/O-1 |
| 6100/6130 NI2 I/O CARD | 6100/30-NI2-I/O-1= |
| NI2, 1 OC3/STM1 Multimode; 1 WAN, 1 Subtend | NI-2-155MM-155MM |
| NI2,1 OC3/STM1 Multimode;1 WAN,1 Subtend - Spare | NI-2-155MM-155MM= |
| NI2, 1 OC3/STM1 Single Mode; 1 WAN, 1 Subtend | NI-2-155SM-155SM |
| NI2,1 OC3/STM1 Single Mode;1 WAN,1 Subtend - Spare | NI-2-155SM-155SM= |
| NI2,1 DS3 WAN, 2 DS3 Subtend | NI-2-DS3-DS3 |
| NI2, 1 DS3 WAN, 2 DS3 Subtend - Spare | NI-2-DS3-DS3= |
| Cisco 6100 Series Modem Options | |
| 6100 Dual CAP ATU-C - Direct Connect | ATUC-2-CAP-DIR-2 |
| 6100 Dual CAP ATU-C - Direct Connect | ATUC-2-CAP-DIR-2= |
| 6100 Dual CAP ATU-C - Digital Off Hook | ATUC-2-CAP-DOH-2 |
| 6100 Dual CAP ATU-C - Digital Off Hook | ATUC-2-CAP-DOH-2= |
| 6100 Dual DMT Issue 2 - Direct Connect | ATUC-2-DMT2-DIR-1 |
| 6100 Dual DMT Issue2 - Direct Connect | ATUC-2-DMT2-DIR-1= |
| 4 port DMT Issue 2 Line Card | ATUC-1-4DMT |
| 4 port DMT Issue 2 Line Card - Spare | ATUC-1-4DMT= |
| Cisco 6100 Series Rear Door Options | |
| Rear Door | 6100-RD-01 |
| Rear Door | 6100-RD-01= |
| Cisco 6100 Series Spares and Accessories | |
| Fan Module: (1) Fan Tray, (3) Fan Units, (1) Fan Filter | 6100-FM-01 |
| Fan Module: (1) Fan Tray, (3) Fan Units, (1) Fan Filter | 6100-FM-01= |
| Fan Unit | 6100-FU-01= |
| Fan Tray | 6100-FT-01= |
| Fan Tray Air Filters, Qty (5) | 6100-AF-01= |
| NEBS Update Kit | 6100-NU-01= |
| 6130 System I/O module | 6100-SYS-IO-3 |
| 6130 System I/O module for NEBS subtending and upgrade | 6100-SYS-IO-3= |
| 6100/6130 NI2 I/O CARD | 6100/30-NI2-I/O-1 |
| 6100/6130 NI2 I/O CARD | 6100/30-NI2-I/O-1= |
| Thermal Upgrade Kit for Cisco6100 | 6100-THERMAL-UPGD= |
| 6100/6130 FAN UPGRADE KIT | 6100-FAN-UPGD-1= |
| 6130 NI-2 Fan Cable | CAB-6130-NI2-FAN= |
| Cisco 6100 Series Software Options | |
| 6100 Software Release 2.2.0 | SF-6100-2.2.0 |
| 6100 Software Release 2.3.3 | SF-6100-2.3.3 |
| 6100 Software Release 3.0 | SF-6100-3.0 |
| 6100 Software Release 2.4.1 | SF-6100-2.4.1 |
| Cisco 6100 Series IOS CISCO 6130 DSL ACCESS CONCENTRATOR IOS | S61Z-12.0.8DA |
| Cisco 6100 Series Software Spares | |
| Cisco 6100 Series IOS CISCO 6130 DSL ACCESS CONCENTRATOR IOS | S61Z-12.0.8DA= |
| Cisco 6100 Series Feature Spare | |
| CISCO IOS 6100/6130 Series DSL Concentrator - ATM QOS | FL61-02= |
| CISCO IOS 6100/6130 Series DSL Concentrator - Subtending | FL61-03= |
| CISCO IOS 6100/6130 Series DSL Concentrator - Signaling | FL61-04= |
| CISCO IOS 6100/6130 Series DSL Concentrator- O2 to O4 Bundle | FL61-05= |
| Cisco 6100 Series Line Interface Options | |
| 6100 Series Quad Line Interface Module | SLC-1-4LIM-CAP |
| Quad LIM Card | SLC-1-4LIM-CAP= |
| 6100 Quad 2B1Q STU-C - Direct Connect | STUC-4-2B1Q-DIR-1 |
| 6100 Quad 2B1Q STU-C - Direct Connect | STUC-4-2B1Q-DIR-1= |
| Cisco 6100 Cables | |
| 6110 to 6100 Cable Kit | CAB-61-011 |
| 6110 to 6100 Cable Kit | CAB-61-011= |
| 6120 to 6100 Cable Kit | CAB-61-014 |
| 6120 to 6100 Cable Kit | CAB-61-014= |
| Cisco 6110 Controller Cards | |
| 6110 LIM Controller | LC-6110-2 |
| 6110 LIM Controller | LC-6110-2= |
| Cisco 6110 Cables | |
| 6110 to 6110 Cable Kit | CAB-61-012 |
| 6110 to 6110 Cable Kit | CAB-61-012= |
| Cisco 6120 Modules | |
| 6120 Quad POTS Splitter Card, 8 kHz | PSC-6120-1= |
| Spare for Quad Port DMT Issue2 POTS Splitter Module | PSM-4-DMT2-1= |
| Cisco 6120 Cables | |
| 6120 to 6110 Cable Kit | CAB-61-013 |
| 6120 to 6110 Cable Kit | CAB-61-013= |
| 6120 to MDF Cable, 50 | CAB-61-015 |
| 6120 to MDF Cable, 50 | CAB-61-015= |
| 6120 to MDF Cable, 150 | CAB-61-016 |
| 6120 to MDF Cable, 150 | CAB-61-016= |
| 6120 to MDF Cable, 75 | CAB-61-017 |
| 6120 to MDF Cable, 75 | CAB-61-017= |
| 6120 to MDF Cable, 175 | CAB-61-018 |
| 6120 to MDF Cable, 175 | CAB-61-018= |
| Cisco 6130 Cables | |
| MC 128 Port to PSC 80 Port Cable Kit | CAB-MC128-PS80 |
| MC 128 Port to PSC 80 Port Cable Kit | CAB-MC128-PS80= |
| 128 Port Mux Chassis to 128 Port PSC Cable | CAB-6121-1 |
| MC to MDF Repin 2x 3:2 Champ Cable Kit | CAB-MC-3:2-REPIN |
| MC to MDF Repin 2x 3:2 Champ Cable Kit | CAB-MC-3:2-REPIN= |
| 128 Port Mux Chassis to MDF Cable Kit | CAB-MC128-MDF |
| 128 Port Mux Chassis to MDF Cable Kit | CAB-MC128-MDF= |
| MC 64 Port Service Mix Cable Kit | CAB-64-MIX |
| MC 64 Port Service Mix Cable Kit | CAB-64-MIX= |
| MC 128 Port Service Mix Cable Kit | CAB-128-MIX |
| MC 128 Port Service Mix Cable Kit | CAB-128-MIX= |
| 79 Port PSC to MDF Re-Pin Cables, 2 Cable Set, 2:2 Champ | CAB-PSC-80-REPIN |
| 79 Port PSC to MDF Re-Pin Cables, 2 Cable Set, 2:2 Champ | CAB-PSC-80-REPIN= |
| 6120 to 6100 Cable Kit | CAB-61-014 |
| 6130 NI-2 Fan Cable | CAB-6130-NI2-FAN= |
To order and configure a Cisco DSL Access Concentrator, follow these steps (see table below):
1. Select a Cisco 6130 chassis for new installations or existing customers deploying Cisco 6130
2. Select configuration style (Direct with POTS, Direct no POTS), and determine if a POTS splitter is required for that configuration style. Direct with POTS implies basic telephone service. Direct no POTS implies basic telephone service is not required.
3. Select network interface (NI) type, (i.e. single-mode optical, multimode optical, or DS3 coax).
4. Determine whether or not you will use subtending.
5. Select xDSL line card type(s).
6. Add one fan tray per Cisco 6130 chassis if SDSL or ADSL DMT cards are to be used.
7. If deploying a Cisco 6130 with an NI-1 card, add a system controller.
8. Select cables. For future releases Cisco is providing cabling to accommodate higher-density SDSL and ADSL line cards. These cables are recommended for customers planning to wire the Cisco DSL Access Concentrators for expansion from dual- to quad-port configurations.
9. Add miscellaneous parts such as blank cards and a rear door for the shelf.
|
Step 1 |
Step 2 |
Step 3 |
Step 4 |
Step 5 |
Step 6 |
|---|---|---|---|---|---|
|
Chassis Selection |
Configuration Style |
Network Interface |
Subtending (Optional) |
xDSL Cards |
Fan Tray Selection |
|
Cisco 6130 |
Direct with POTS |
Select optical (OC3) or electrical (DS3) |
If required, select subtending card and cables |
2xDMT |
Needed with 2xDMT |
|
Cisco 6130 |
Direct no POTS splitter |
Select optical (OC3) or electrical (DS3) |
If required, select subtending card and cables |
2xDMT 4xSDSL |
Needed with 2xDMT, or 4xSDSL |