cc/td/doc
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Cisco LightStream 1010 — 5 Gbps Modular Switch

Cisco LightStream 1010 — 5 Gbps Modular Switch

Product Overview

The Cisco LightStream 1010 is a 5 Gbps modular switch designed for use in either the workgroup or the campus, depending on the nature of the interfaces employed. The Cisco LightStream 1010 uses a five-slot, modular chassis featuring the option of dual, fault-tolerant, load-sharing power supplies.

The central slot in the Cisco LightStream 1010 is dedicated to a single, field-replaceable ATM switch processor module (ASP) that supports both the 5 Gbps shared memory, fully nonblocking switch fabric, together with its feature card, and the high-performance RISC processor that provides the central intelligence for the device. Uniquely, the ASP module feature card can also be upgraded in the field, allowing the switch to track changing ATM specifications. The remaining slots support up to four hot-swappable carrier modules (CAMs), each of which, in turn, can support up to two hot-swappable port adapter modules (PAMs), for a maximum of eight PAMs per switch, supporting a wide variety of desktop, backbone, and wide-area ATM interfaces.

The Cisco LightStream 1010 offers the sophistication and depth of functionality required for true ATM production deployment. Advanced traffic management mechanisms allow for the support of current, bursty, best-effort traffic, while also delivering the quality of service (QOS) guarantees required for the applications of the future. Available bit rate (ABR) congestion control support allows the Cisco LightStream 1010 to slow traffic sources before congestion becomes excessive, while support for the ATM Forum PNNI protocols allows networks of Cisco LightStream 1010s to scale to hundreds of nodes while still delivering interoperable, QOS-based routing. Value-added capabilities allow for ATM access lists and load sharing across redundant links. All of this sophistication is hidden, however, by the true standards-based, plug-and-play capabilities of the Cisco LightStream 1010, and advanced management functions allow for unprecedented levels of network visibility and control.

Key Features and Benefits

The Cisco LightStream 1010 switch includes the following standard features:

The Cisco LightStream 1010 uses two management tools: AtmDirector and CiscoView.

AtmDirector

Using underlying ATM network management protocols such as the Interim Local Management Interface (ILMI), as well as standard and Cisco-private ATM MIBs, Cisco Systems` AtmDirector management application simplifies the installation and administration of ATM in switched internetworks.

AtmDirector is a graphical, system-level ATM management application for configuring, monitoring, and troubleshooting a network of Cisco LightStream ATM switches and ATM-attached Cisco routers and Catalyst LAN switches. The AtmDirector application automatically discovers and illustrates the topology of the ATM network, displays real-time link information, facilitates ATM network interrogation and troubleshooting by allowing selection of any virtual connection on an ATM link and tracing its entire path, and provides an intuitive interface for creating PVCs across the ATM network. AtmDirector can be integrated with popular SNMP management platforms or used as a fully functional, independent ATM network management application.

These advanced ATM management functions provide real-time status, statistics, and configuration information, allowing the administrator to more easily understand and use the complex management data available for ATM networks.

Specifications

Hardware
Table 20-137: Technical Specifications for Cisco LightStream 1010 Switch

Description

Specification

Switch and processor capacity

5 Gbps shared memory, nonblocking switch fabric

65,536 cells of shared ATM cell buffers

16 MB processor DRAM standard, maximum of 64 MB

8 MB Flash memory standard, internally expandable up to 16 MB plus up to 20 MB through PCMCIA Flash cards

Software images

Optional PNNI image with plug-and-play capability

Port adapter modules

PAM with 4 SONET STS3c/SDH STM1 multimode fiber ports, SC connectors

PAM with 4 SONET STS3c/SDH STM1 single-mode fiber ports, SC connectors

PAM with 4 SONET STS3c/SDH STM1 UTP-5 ports, SC connectors

PAM with 4 SONET STS3c/SDH STM1 ports, 1 single-mode, 3 multimode

PAM with 4SONET STS3c/STM1 single-mode fiber port, SC connector, long reach, laser

PAM with 1 SONET STS12c/SDH STM4 multimode fiber port, SC connector

PAM with 1 SONET STS12c/STM4 single-mode fiber port, SC connector

PAM with 1 SONET STS12c/SDH STM4 single-mode fiber ports, SC connectors, long reach, laser

PAM with 4 T3 (DS3) ports, BNC connectors

PAM with 4 E3 ports, BNC connectors

Port adapter modules

PAM with 4 T1 (trunk) ports, RJ-48 connectors

PAM with 4 E1 (trunk) ports, RJ-48 connectors, balanced

PAM with 4 E1 (trunk) ports, BNC connectors, unbalanced

PAM with 4 T1 (circuit emulation) ports, RJ-48 connectors

PAM with 4 E1 (circuit emulation) ports, RJ-48 connectors, balanced

PAM with 4 E1 (circuit emulation) ports, BNC connectors, unbalanced

PAM with 12 ATM25 ports with 96-pin Telco Cable

Interface timing

Loop timing, Stratum 4 accuracy clock for self-timing, master clock distribution port

Management access

Standard Ethernet and dual EIA/TIA 232 serial ports on ASP module

Connections

32,000 point-to-point, 2048 point-to-multipoint

VC and VP switching, VP tunneling

PVC and SVC

F4 and F5 OAM segment and end-to-end flows, RDI and AIS

OAM Ping on IP or ATM address

Signaling and routing

UNI 3.0, UNI 3.1

ILMI

PNNI Phase 1, IISP

Soft PVC/PVP support

ATM access lists and firewalls

Crankback

Plug-and-play mode with PNNI image

Redundant link support with load balancing or best-fit selection

Traffic management

Single, dual-mode leaky bucket traffic policing

Per-port traffic pacing

Multiple, configurable per connection, port, and switch thresholds

Multiple priority classes

All ATM connection types and AALs

Connection admission control

CLP tagging and discard

Intelligent packet discard

Available bit rate support: EFCI marking mode and relative rate marking mode

Network management

Port Rx and Tx LEDs, switch and common equipment status LEDs

Port snooping and connection steering

Multiple standard and enterprise MIBs

Text-based command-line interface based on familiar router interface

Standard Cisco IOS security capabilities: passwords and TACACS

Telnet, TFTP, BOOTP, LAN Emulation client, RFC 1577 Classical IP over ATM client, for management access

CiscoView GUI application for device configuration and management

AtmDirector GUI system management application

Mean Time between Failure (MTBF)

7.1 years for system configuration

These PAMs and cables are available only with the Cisco IOS software for ATM maintenance Release 1, or later releases.

This PAM is available only with the Cisco IOS software for ATM maintenance Release 2, or later releases.


Table 20-138: Power Requirements for Cisco LightStream 1010 Switch

Description

Specification

Max power budget

9.8A @ 115 VAC, 60 Hz 4.9A @ 230 VAC, 50 Hz

Autosensing limits

100-127/200-240 VAC, 8/4A, 47-63 Hz

Max wattage

376W


Table 20-139: Physical and Environmental Specifications for Cisco LightStream 1010 Switch

Description

Specification

Altitude

-500 to 10,000 ft (-52 to 3048 m)

Temperature

32 to 104°F (0 to 40°C)

Relative humidity

10 to 90% noncondensing

Dimensions

(H x W x D)

Chassis: 10.5 x 17.2 x 18.1 in. standard 19-in. rack mount (26.7 x 43.7 x 46.1 cm)

ASP and CAM: 1.2 x 14.4 x 16.0 in. (3.0 x 36.6 x 40.6 cm)

PAM: 1.2 x 6.5 x 10 in. (3.0 x 16.5 x 25.4 cm)

Weight

Empty: 43 lb (19.5 kg)

Fully loaded: approximately 85 lb (39 kg) (depends on loading)


Table 20-140: Regulatory Approvals for Cisco LightStream 1010 Switch

Description

Specification

Safety

UL 1950, EN 60950, CSA-C22.2 No. 950-93

EMI

FCC Class A (Part 15), EN 55022 Class B, CE Mark, VCCI Class II


Software

CiscoView Management Software for the Cisco LightStream 1010

The CiscoView application for Cisco LightStream 1010 ATM switch is a graphical user interface (GUI)-based device management application that provides dynamic status, statistics, and configuration information for the Cisco LightStream 1010. This application is a subset of the CiscoView application that offers similar features for other switched internetworking products such as Catalyst LAN switches and Cisco routers.

The CiscoView application is also included within CiscoWorks, Cisco`s enterprise network management application suite. The application displays a physical view of any Cisco device and shows real-time LED and interface status. The CiscoView application provides comprehensive monitoring functions and simplifies basic troubleshooting tasks.

Using the CiscoView application for the Cisco LightStream 1010, users can more easily understand the complex management data and configuration parameters available for ATM switches. It organizes this information into graphical representations presented in a clear, consistent format.

The CiscoView application for the Cisco LightStream 1010 can be integrated with several of the leading network management platforms, providing management application integration. It can also be run on UNIX workstations as a fully functional, independent Cisco LightStream 1010 management application. In addition, it can be launched from the AtmDirector topology map by simply double-clicking on a Cisco LightStream 1010 icon.

Ordering Information

Product and Part Numbers Table 20-141: Part Numbers for the Cisco LightStream 1010
Part DescriptionPart Number
Chassis
5-slot chassis L1010-CHAS5
Power Supplies and Power Cords
AC-input power supply L1010-PWR-AC
AC-input redundant power supply L1010-PWR-AC/2
DC-input power supply L1010-PWR-DC
DC-input redundant power supply L1010-PWR-DC/2
ATM Switch Processor Options
ATM switch processor with FC-Per-Class Queuing (FC 1) LS1010-ASP-B-FC1
ATM switch processor with FC-Per-Class Queuing (FC 1) LS1010-ASP-C-FC1
ATM switch processor with FC-Per-Class Queuing (FC-PFQ) LS1010-ASP-B-FCPFQ
Multiservice ATM Switch Route Processor LS1010-ASP-C-FCPFC
DRAM options
ASP DRAM 32 MB SIMM MEM-ASP-32M
ASP DRAM 64 MB SIMM MEM-ASP-64M
Flash memory cards
PCMCIA Flash memory card, 8 MB (spare) MEM-ASP-FLC8M=
PCMCIA Flash memory card, 16 MB (spare) MEM-ASP-FLC16M=
PCMCIA Flash memory card, 20 MB (spare) MEM-ASP-FLC20M=
Port adapter modules
PAM — 4 ports STS3c/STM1 multimode fiber WAI-OC3-4MM
PAM — 4 ports STS3c/STM1 single-mode fiber WAI-OC3-4SS
PAM — 4 ports STS3c/STM1 UTP-5 WAI-OC3-4U5
PAM — 4 ports 1 single-mode fiber, 3 multimode fiber WAI-OC3-1S3M
PAM — 4 ports STS3c/STM1 single-mode fiber, long-reach, laser WAI-OC3-4SSLR
PAM — 1 port STS12c/STM4 multimode fiber WAI-OC12-1MM
PAM — 1 port STS12c/STM4 single-mode fiber WAI-OC12-1SS
PAM — 1 port STS12c/STM4 single-mode fiber, long-reach, laser1 WAI-OC12-1SSLR
PAM — 4 ports T3 (DS3), coaxial cable, BNC connectors (supports clocking) WAI-T3-4BNC
PAM — 4 ports E3, coaxial cable, BNC connectors WAI-E3-4BNC
PAM — 4 ports T1 (trunk), RJ-48 connectors WAI-T1-4RJ48
PAM — 4 ports E1 (trunk), RJ-48 connectors, balanced WAI-E1-4RJ48
PAM — 4 ports E1 (trunk), BNC connectors, unbalanced WAI-E1-4BNC
PAM — 4 ports T1 (circuit emulation), RJ-48 connectors WAI-T1C-4RJ48
PAM — 4 ports E1 (circuit emulation), RJ-48 connectors, balanced WAI-E1C-4RJ48
PAM — 4 ports E1 (circuit emulation), BNC connectors, unbalanced WAI-E1C-4BNC
PAM — 12 ports ATM25 with 96-pin Telco Cable1 WAI-ATM25-12P
Cables
96-pin Telco Cable for 12-port ATM25 PAM (spare)1 CAB-ATM25-12=
ATM cables, DS3 and E3, 10 ft CAB-ATM-DS3/E3
Software images
IISP and PNNI feature set installed SF-WAS3-5
IISP and PNNI feature set installed SF-WAS3-6
IISP and PNNI feature set installed SF-WAS4-4
IISP and PNNI feature set installed SF-WAS4-6
Service
Cisco LightStream 1010 SMARTnet maintenance See the "Services and Support" chapter
Carrier modules
Carrier module for 2-port adapter modules with PAM slot covers for empty slots WATM-CAM-2P
CAM slot cover (spare) WATM-CAM-CVR=
PAM slot cover (spare) WAI-CVR=

Configuration Worksheets

Configuration Guidelines

The default configuration for the Cisco LightStream 1010 is a chassis. ASP modules, carrier modules, PAMs, power cords, power supplies, and cables must be ordered separately. The PNNI Cisco IOS software image supports both the IISP and PNNI Phase 1 protocols.

The Cisco LightStream 1010 uses the same power cords as the Cisco 7000 router and the Catalyst 5000.

When ordering a Cisco LightStream 1010 system that has been configured by the factory, the following items must be included on the purchase order:

All other components — redundant power supply, carrier modules, port adapter modules, and Flash memory cards — are options; these can be ordered at the same time as the base chassis if you want to have them installed in the factory. They can also be ordered as spares, as can the chassis, ASP, ASP DRAM SIMMs, and ASP Flash memory cards. Configuration rules should also be followed when ordering a spare ASP module; the cost of the default software image is included in the spare ASP price.

Carrier Modules and Port Adapters

Use the following guidelines to configure the Cisco LightStream 1010 carrier modules and port adapters:

Table 20-142: Cisco LightStream 1010 Carrier Module Ordering

Number of Port Adapter Modules

1

2

3

4

5

6

7

8

Number of Required Carrier Modules

1

1

2

2

3

3

4

4



Note There is no switch slot dependency for CAMs — they can be plugged into any available switch slot. CAMs ordered as spares will be shipped with two PAM slot covers. CAMs installed in the factory will ship with PAM slot covers for any slots not occupied by PAMs.

Example Orders

To Order a base Cisco LightStream 1010 chassis with a redundant AC-input power supply, U.S. power cords, an ASP feature card 1, the PNNI image, two multimode fiber 155 Mbps PAMs (8 ports), and one 4-port T3 (DS3) PAM, all to be installed in the factory, use the product numbers in the following table.

Table 20-143: Cisco LightStream 1010 Ordering Examples — Example 1

Description

Product Number

Base chassis

1 x L1010-CHAS5

Power supply

1 x L1010-PWR-AC

ASP feature card 1

1 x L1010-ASP-B-FC1

32 MB DRAM

1 x MEM-ASP-32M

PNNI image (default)

1 x SF-WAS4-4

Redundant AC-input power supply

1 x L1010-PWR-AC/2

U.S. power cords

2 x CAB-7KAC

Carrier modules

2 x WATM-CAM-2P

155 Mbps MMF PAM

2 x WAI-OC3-4MM

4-port T3(DS3) PAM

1 x WAI-T3-4BNC


To Order a Cisco LightStream 1010 with a DC-input power supply, 32 MB of DRAM, an ASP feature card 1, an 8 MB Flash memory PCMCIA card, European power cord, the PNNI/IISP image, three multimode fiber 155 Mbps PAMs (12 ports), and one E3 PAM, use the product numbers listed in the table below.

Table 20-144: Cisco LightStream 1010 Ordering Examples — Example 2

Description

Product Number

Base chassis

1 x L1010-CHAS5

Power supply

1 x L1010-PWR-DC

ASP feature card 1

1 x LS1010-ASP-B-FC1

32 MB DRAM

1 x MEM-ASP-32M

European power cord

1 x CAB-7KACE

PNNI/IISP image

1 x SF-WAS4-4

8 MB Flash card (spare)

1 x MEM-ASP-FLC8M=

Carrier modules

2 x WATM-CAM-4P

155 Mbps MMF PAM

3 x WAI-OC3-4MM

E3 PAM

1 x WAI-E3-2BNC


Configuration Worksheet

Table 20-145: Cisco LightStream 1010 Configuration — System

Chassis (AC-input power supply)

L1010-CHAS55

Power supply

L1010-PWR-DC

Dual power supply option (AC-input)

L1010-PWR-AC/2

(DC-input)

L1010-PWR-DC/2

Rack-mounting hardware

Included

Cable-management kit

Included

AC-input power cord

U.S. (CAB-7KAC)

U.K. (CAB-7KACU)

Italy (CAB-7KACI)

Australia (CAB-7KACA)

Europe (CAB-7KACE)

Software

-

SF-WAS4-4 (PNNI/IISP)

-

Substitute the software release number for x in the product number (for example, SF-WAS1-11.1.8).


Table 20-146: Cisco LightStream 1010 Base Chassis

Base Chassis and Options

Product Number

5-slot chassis

L1010-CHAS5

Feature Licenses

IISP to OOSP + PNNI license

Hierarchical PNNI license

Tag Switching license

Hierarchical PNNI + Tag switching license

FR-WA-SX-PNNI

FR-WA-SX-HPPNI

FR-WA-SX-TAGSW

FR-WA-SX-TSHPNNI

ASP feature card 1

L1010-ASP-B-FC1

ASP DRAM memory, 16 MB SIMMs

MEM-ASP-16M

ASP DRAM memory, 32 MB SIMMs

MEM-ASP-32M

ASP DRAM memory, 64 MB SIMMs

MEM-ASP-64M

ASP Flash memory card, 8 MB

MEM-ASP-FLC8M=

ASP Flash memory card, 16 MB

MEM-ASP-FLC16M=

ASP Flash memory card, 20 MB

MEM-ASP-FLC20M=

Carrier modules

ATM-CAM-2P


Table 20-147: Cisco LightStream 1010 Interface Modules

Interface Modules

Product Number

PAM — 4 ports STS3c/STM1 multimode fiber

WAI-OC3-4MM

PAM — 4 ports STS3c/STM1 single-mode fiber

WAI-OC3-4SS

PAM — 4 ports STS3c/STM1 UTP-5

WAI-OC3-4U5

PAM — 4 ports 1 single-mode fiber, 3 multimode fiber

WAI-OC3-1S3M

PAM — 4 ports STS3c/STM1 single-mode fiber, long-reach, laser

WAI-OC3-4SSLR

PAM — 1 port STS12c/STM4 multimode fiber

WAI-OC12-1MM

PAM — 1 port STS12c/STM4 single-mode fiber

WAI-OC12-1SS

PAM — 1 port STS12c/STM4 single-mode fiber, long-reach, laser

WAI-OC12-1SSLR

PAM — 4 ports T3 (DS3), coaxial cable, BNC connectors

WAI-T3-4BNC

PAM — 4 ports E3, coaxial cable, BNC connectors

WAI-E3-4BNC

PAM — 4 ports T1 (trunk), RJ-48 connectors

WAI-T1-4RJ48

PAM — 4 ports E1 (trunk), RJ-48 connectors, balanced

WAI-E1-4RJ48

PAM — 4 ports E1 (trunk), BNC connectors, unbalanced

WAI-E1-4BNC

PAM — 4 ports T1 (circuit emulation), RJ-48 connectors

WAI-T1C-4RJ48

PAM — 4 ports E1 (circuit emulation), RJ-48 connectors, balanced

WAI-E1C-4RJ48

PAM — 4 ports E1 (circuit emulation), BNC connectors, unbalanced

WAI-E1C-4BNC

PAM — 12 ports ATM25 with 96-pin Telco Cable

WAI-ATM25-12P

Cables

96-pin Telco Cable for 12-port ATM25 PAM (spare)

CAB-ATM25-12=

ATM cable, DS3 and E3, 10 ft

CAB-ATM-DS3/E3

These PAMs and cables are available only with the Cisco IOS software for ATM maintenance Release 1, or later releases.

This PAM is available only with the Cisco IOS software for ATM maintenance Release 2, or later releases.


Ordering Information

This section describes hardware and software product numbers for the Cisco LightStream 1010.

If a product number ends with an equal sign (=), the item can be ordered only as a spare. If a product number does not end with an equal sign, the item can be ordered as a spare or as a configurable part of a system order.

hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Sep 27 05:15:22 PDT 2000